HomeMy WebLinkAboutT-4332028Xrefs: FcNo
xS1-BT120-CPP
coxS1-BT120-VRX
xS1-BT120-CDP
xS1-BT120-TSP
xS1-BT120-CLP
T
xS1-BT120-APP
xS1-BT120-LHP
xS1-BT120-LPP
0
xS1-BT120-CMP
xBRT-CUD05-TB
xS1-BT120-GZK
xS1-BT120-CAP
xS1-BT120-VSF100
GB-SEAL-RJH43665
xS1-BT120-JCP101
xS1-BT120-EPP101
xS1-BT120-JCP001
xS1-BT120-GZKO10
xS1-BT120-TIP001
xS1-BT120-CZN002
C�
0
co
O
4
O
a
J
O
N
m
0
N
co
co
Nt
O
0
O
z
x
w
(D
z
Q W
Z 06
�mi
O CO
_o
� Q
co U
O z
N v
N
N >>
a
o U
MATCHLINE: MATCHLINE:
SEE DWG BT120-CLP205 SEE DWG BT120-CLP204
GENERAL NOTES: CONSTRUCTION NOTES:
1. SEE SHEET BT120-CLP100 FOR ILLUMINATION
GENERAL NOTES.
2. SEE SHEET BT120-CLN101 FOR ILLUMINATION
LEGEND.
3. SEE SHEET BT120-CLS101 FOR ILLUMINATION
WIRING SCHEDULE
4. SEE SHEET BT120-CLS102 THROUGH
BT120-CLS103 FOR ILLUMINATION POLE
SCHEDULE.
5. ALL EXISTING ILLUMINATION NOT CALLED OUT
TO BE REMOVED SHALL BE MAINTAINED AND
6. REFER TO CITY OF RENTON STANDARD PLAN 135
FOR ADDITIONAL TRANSPORTATION NOTES.
1
06/13/2025
OW
RT
I RH
ADDENDUM #1
12/10/2024
OW
RT
RH
ISSUED FOR BID
L0
No.
DATE
DSN
CHK
I APP
REVISION
OCONSTRUCT FOUNDATION AND INSTALL PEDESTRIAN SCALE POLE WITH
"ALT1" LED LUMINAIRE AND ARM. SEE ILLUMINATION POLE SCHEDULE.
OREMOVE LIGHT POLE, FOUNDATION, LUMINAIRE, AND ALL ASSOCIATED
WIRING/CONDUIT TO SPLICE POINT.
71 CONTRACTOR TO PROVIDE 14 DAY NOTICE TO CITY OF RENTON POLICE
-J DEPARTMENT, PATROL SERVICES FOR REMOVAL OF RED LIGHT CAMERA
EQUIPMENT, INCLUDING ASSOCIATED SIGNING AT THE INTERSECTION -
CONTACT INFO: STEVE MORRIS, 425-430-7597, SMORRIS@RENTONWA.GOV.
RENTON PD WILL REINSTALL IN APPROXIMATELY THE SAME LOCATION.
OINSTALL PEDESTRIAN SCALE LUMINAIRE POLE WITH 2' LUMINAIRE ARM AND
FOUNDATION WITH NEW LED FIXTURE PER CITY OF RENTON STANDARD
PLAN 117.2. FOUNDATION DEPTH SHALL BE 5' MINIMUM. 1
10 INSTALL TYPE 2 JUNCTION BOX PER CITY OF RENTON STANDARD PLAN 119.
1 i (27
D-ESPIOT,
f
29 INSTALL CONCRETE PAD PER CITY OF RENTON STANDARD PLAN 120.
DESIGNED BY:
R. TLEHHEMA
DRAWN BY:
R. SNELLINGS
CHECKED BY:
E. SHIMIZU
APPROVED BY:
R. HUTCHINSON
H
r ijjjngjW
43665
�GISTfR V
IDNAI �SUBMITTED BY:
6/12/2025 R. PARGAS
1
QLu
4,VrJ?IDE J
co_ co
J
BRT General Engineering Consultant zLL SOUNDTRANSI
DATE: REVIEWED BY: DATE:
12/10/2024 J. ALTCHECH 12/10/2024
In
O
Ar
li
J
V
0
N
H
m
0
0
W
W
U)
T
20 10 0 20 4FMDEVESLiCPMENT
0
SCALE IN FEET
ENGINEERING }
po 11 /25/2025 T-433228
InRAWIN(, Nn
1"-20' STRIDE BUS RAPID TRANSIT
FILENAME: SOUTH RENTON TRANSIT CENTER
S 1-BT120-CLP 104-106 BT 105
CONTRACT No.:
RTA/C N 0205-24 CIVIL
DATE: ILLUMINATION PLAN
12/10/2024 GRADY STA 151 +00 TO GRADY STA 156+50
KEY MAP
TRANSPORTATION OPERATION
CBarnes 12/01 /2025
Yffim
BT120-CLP104
FACILITY ID:
BT120
SHEET No.: REV:
189 1
C'7
N
T
N
0
0
N
CU
LO
V J
0
0
0
0
T
rr
n
co
co
N
O
O
O
4
N
Q
J