Loading...
HomeMy WebLinkAboutT-4332032Xrefs: co xS1-BT120-CPP M xS1-BT120-VRX xS1-BT120-CDP I xS1-BT120-TSPO T xS1-BT120-CLPO lzt xS1-BT120-LHPO xS1-BT120-LPPO O xS1-BT120-CMP xBRT-CUD05-TB 0 xS1-BT120-GZK xS 1-BT120-CAP xS1-BT120-VSF1 10 GB-SEAL-RJH43665 xS1-BT120-APP211 xS1-BT120-JCP001 xS1-BT120-EPP101 xS1-BT120-GZKO10 xS1-BT120-TIP001 xS1-BT120-CZN002 C� 0 0 N 0 N d J U 0 N m 0 N co co 0 0 'O z X W U Z O Q W 06 Z m Lu O CO O — U �a °O CD Z_ N � N N a o U GENERAL NOTES: 1. SEE SHEET BT120-CLP100 FOR ILLUMINATION GENERAL NOTES. 2. SEE SHEET BT120-CLN101 FOR ILLUMINATION LEGEND. 3. SEE SHEET BT120-CLS101 FOR ILLUMINATION WIRING SCHEDULE 4. SEE SHEETS BT120-CLS102 THROUGH BT120-CLS103 FOR ILLUMINATION POLE SCHEDULE. 5. ALL EXISTING ILLUMINATION NOT CALLED OUT TO BE REMOVED SHALL BE MAINTAINED AND PROTECTED. 6. SEE ELECTRICAL SHEETS BT120-ESP101, BT120-EPS104, AND BT120-EPS113 FOR CONDUIT I I GAN CR UI I F R A 10 7. REFER TO CITY OF RENTON STANDARD PLAN 135 FOR ADDITIONAL TRANSPORTATION NOTES. 1 EXISTING R/W MATCHLINE: SEE DWG BT120-CLP204 CONSTRUCTION NOTES: OCONSTRUCT FOUNDATION AND INSTALL LIGHT POLE WITH "ALT2" LED LUMINAIRE AND ARM. SEE ILLUMINATION POLE SCHEDULE. OCONSTRUCT FOUNDATION AND INSTALL LIGHT POLE WITH DUAL ARM "ALT2" LED LUMINAIRES IN 180 DEGREE CONFIGURATION. SEE ILLUMINATION POLE SCHEDULE. 3O REMOVE EXISTING LIGHT POLE FOUNDATION. OCONSTRUCT FOUNDATION AND INSTALL PEDESTRIAN SCALE POLE WITH "ALT1" LED LUMINAIRE AND ARM. SEE ILLUMINATION POLE SCHEDULE. OFURNISH AND INSTALL ABOVE GRADE LIGHT POLE FOUNDATION. SEE SHEET BT120-SGY403 FOR ADDITIONAL DETAILS. 28 REMOVABLE POLE IN SCL EASEMENT. POLE TO BE INSTALLED WITH QUICK -DISCONNECT WIRING KIT. Lti 0. ,J W C� Z_ o J CNI 2 � Vm Q � 0 W W U) UPDATES TO ROW SEE SHEETS BT120-RPP101-BT120-RPP102 BT120-RPP105-BT120-RPP106 BT1 20-RPP201 -BT1 20-RPP205 20 10 0 20 40 KEY MAP SCALE IN FEET DEVELOPMENT ENGINEERING Is msippo 11 /25/2025 T-433232 DESIGNED BY: SCALE: DRAWING No.: R. TLEHHEMA HUT F- w rw I119=20' STRIDE BUS RAPID TRANSIT �� F wash ��f�' Q U FILENAME: SOUTH RENTON TRANSIT CENTER BT120-CLP202 =) I DRAWN BY: Q' 4bV (n co I I rJ?IDE I R. SNELLINGS w J S1-BT120-CLP201-205 BT105 FACILITY ID: k I ICHECKED BY: BRT General Engineering Consultant z " SOUNDTRANSIT CONTRACT No.: CIVIL BT120 LNo. 06/13/2025 OW RT RH ADDENDUM #1 E. SHIMIZU ,� 43665 <`� RTA/CN 0205-24 SHEET No.: REV: 12/10/2024 OW RT RH ISSUED FOR BID APPROVED BY: GISTF�ONAL ����� SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE: ILLUMINATION PLAN IFT S RENTON TRANSIT CENTER 193 1 DATEDSN CHK APP REVISION JR. HUTCHINSON 6/12/2025 R. PARGAS 112/10/2024 J. ALTCHECH 112/10/2024 12/10/2024 Nv 5 -;t U I 103 I L I I 1 102 201 I 107 r 202 106 y _ 203 I 204 Q L � J Q 205 105 101 � 104 III GR DY l� WAY c! co T N 0 0 N U LO (3) 0 0 0 0 T C'7 C'7 N O O O N Q J