Loading...
HomeMy WebLinkAboutT-4332039N Xrefs: M xBRT-CUD05-TB (� GB-SEAL-RJH43 T O rr U 0 0 z 0 N m W 0 N CO C7 0 co J J W Z_ Z J U) J X W W Z U) (D Q W U 3 U � W co W U) CO —O U Qa co U N z Y Ln N a o U 1 06/13/2025 BN RT JRH ADDENDUM #1 12/10/2024 BN RT RH ISSUED FOR BID L0 No. DATE DSN CHK I APP REVISION GENERAL NOTES: 1. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE CITY OF RENTON STANDARDS, WSDOT/APWA STANDARD PLANS, CURRENT WSDOT STANDARD SPECIFICATIONS, LATEST AMENDMENTS TO THE STANDARD SPECIFICATIONS, SPECIAL PROVISIONS, AND THESE PLANS. 2. THE LOCATION OF ALL NEW POLES AND EQUIPMENT TO BE INSTALLED SHALL BE VERIFIED IN THE FIELD BY THE ENGINEER PRIOR TO INSTALLATION. 3. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS (I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). 4. THE CONSTRUCTION PLANS DO NOT SHOW ALL UNDERGROUND UTILITIES. ALL EXISTING UTILITIES SHALL BE LOCATED AND MARKED IN THE FIELD PRIOR TO PERFORMING ANY UNDERGROUND WORK INCLUDING FOUNDATION EXCAVATION, CONDUIT TRENCHING AND/OR CONDUIT BORING TO AVOID DAMAGE TO ANY UNDERGROUND UTILITIES. HAND DIGGING MAY BE REQUIRED IN AREAS WHERE EXISTING UNDERGROUND UTILITIES CONFLICT WITH POLE FOUNDATION INSTALLATION. UTILITY COMPANIES SHALL BE CONTACTED THROUGH THE ENGINEER IF PROPOSED CONSTRUCTION CONFLICTS WITH ANY EXISTING UTILITIES. ALL EXISTING UTILITY INFRASTRUCTURE TO BE PROTECTED AT ALL TIMES THROUGHOUT CONSTRUCTION. 5. ALL NEW SIGNS SHALL COMPLY WITH THE MUTCD, CITY OF RENTON, AND WASHINGTON STATE SUPPLEMENT TO THE MUTCD. 6. ALL NEW METAL CONDUITS SHALL BE GROUNDED AND BONDED IN ACCORDANCE WITH NEC REQUIREMENTS AND WSDOT STANDARD PLAN J-60.05-01 (TYPICAL GROUNDING DETAILS). 7. CONDUIT AND JUNCTION BOX LOCATIONS ARE SCHEMATIC. VERIFY FINAL LOCATIONS WITH THE ENGINEER PRIOR TO INSTALLATION. 8. NEW JUNCTION BOXES LOCATED WITHIN PEDESTRIAN WALKWAYS SHALL HAVE SKID -RESISTANT LID SURFACE. 9. PROPOSED CONDUITS PLACED BENEATH ROADWAYS AND SHOULDER AREAS SHALL BE SCHEDULE 80 PVC. PROPOSED CONDUITS PLACED IN ALL OTHER AREAS SHALL BE SCHEDULE 40 PVC. DIRECTIONAL BORED CONDUITS SHALL BE HDPE. 10. ALL PEDESTRIAN PUSH BUTTONS SHALL BE ACCESSIBLE APS TYPE AND CONFORM TO THE CONTRACT SPECIFICATIONS. PUSH BUTTONS SHALL BE MOUNTED PER MANUFACTURER'S SPECIFICATIONS. 11. ALL NEW CONDUCTOR(S) SHALL BE PERMANENTLY LABELED IN EACH JUNCTION BOX, CABINET, AND TERMINAL CABINET. 12. ALL NEW TRAFFIC SIGNAL HEADS, PEDESTRIAN HEADS, AND PUSH BUTTONS SHALL BE SECURELY COVERED WHILE NOT IN OPERATION. 13. NEW CONDUITS SHALL SHARE THE SAME TRENCH WITH OTHER NEW UTILITIES WHEREVER PRACTICABLE. 14. CONTRACTOR SHALL MAINTAIN THE EXISTING OR HIGHER LIGHTING LEVELS UNTIL NEW FIXTURES ARE INSTALLED AND OPERATIONAL. 15. CONDUIT BENDS AND SWEEPS FOR FIBER CONDUIT RUNS SHALL NOT EXCEED 3-FEET MINIMUM RADIUS. 16. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL BE MORE THAN THE EQUIVALENT OF FOUR 90 DEGREE BENDS OR 360 DEGREES TOTAL. THE CONTRACTOR SHALL FURNISH AND INSTALL ADDITIONAL JUNCTION BOXES AS REQUIRED. 17. SIGNAL POLE AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 18. ALL PROPOSED SIGNAL POLE FOUNDATIONS SHALL INCLUDE A CONCRETE PAD AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK SHALL BE CONSIDERED PART OF THE FOUNDATION PAD. FOUNDATION PAD SHALL BE AT LEAST 2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS. 19. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON TRANSPORTATION OPERATIONS MAINTENANCE DEPARTMENT PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION OPERATIONS MAINTENANCE MANAGER OR OTHER TRANSPORTATION OPERATIONS MAINTENANCE REPRESENTATIVE. 20. CONTRACTOR SHALL COORDINATE TESTING AND PROGRAMMING OF DETECTION CAMERAS WITH THE CITY OF RENTON. DESIGNED BY: R. TLEHHEMA DRAWN BY: R. SNELLINGS CHECKED BY: E. SHIMIZU APPROVED BY: R. HUTCHINSON H wZ� 43665 �GISTER� ZONAL �� SUBMITTED BY: 6/12/2025 R. PARGAS LEGEND*: EVP SENSOR �EGPS ANTENNA +__ VEHICLE SIGNAL HEAD VEHICLE SIGNAL HEAD WITH TURN ARROW LUMINAIRE Ct immm— TRAFFIC SIGNAL POLE m 0 0 JUNCTION BOX (TYPE 1, TYPE 2, TYPE 8) — — — — — CONDUIT 1—H+► PEDESTRIAN SIGNAL HEAD • PEDESTRIAN PUSH BUTTON POLE PEDESTRIAN PUSH BUTTON EEN DETECTION CAMERA EEN PTZ CAMERA I� MAST ARM MOUNTED SIGN m CONTROLLER CABINET IN UNINTERRUPTIBLE POWER SUPPLY ® SERVICE CABINET SCV SMALL CABLE VAULT o— GPS OPTICOM O# POLE NOTE O# CONSTRUCTION NOTE O SIGNAL HEAD NUMBER �# SIGN NUMBER * SEE SHEETS BT120-GZN006-GZN007 FOR GENERAL SYMBOLS AND LEGEND Q Q U co 4,VrJ?IDE co J w _j BRT General Engineering Consultant z SOUNDTRANSIT DATE: REVIEWED BY: DATE: 12/10/2024 J. ALTCHECH 12/10/2024 SCALE: NTS FILENAME: S1-BT120-TSN101 CONTRACT No.: RTA/CN 0205-24 DATE: 12/10/2024 E STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 TRAFFIC SIGNAL LEGEND T-433239 DEVELOPMENT ENGINEERING msippo 11 /25/2025 %J I by;f-lv,Ti 101 lei \• BT120-TSN101 FACILITY ID: BT120 SHEET No.: REV: 238 1 C'7 N T N O N CU H H H N d C'7 N O O O 4 Q J