HomeMy WebLinkAboutR-4332295N co C'7 W 0 N O N ch 6 N m co U w 0 I H z Q H I D_ I U) m 0 I 0 co 2 � Q� o m o� rn QI O N 004 0 m Y ry (D H N Q w 00 U co z 0.1 SLAB REINF )ER V f\/'11 V lJ L/'1f\ r I LL NOTES: 1. SEE PLANS FOR SLAB ON GRADE THICKNESS. SLAB ON GRADE IS 6-INCH THICK UNLESS NOTED OTHERWISE. 2. REINFORCE UP TO 4-INCH THICK SLAB ON GRADE WITH #4 @ 18" EACH WAY, UP TO 6-INCH THICK SLAB ON GRADE WITH #4 @ 16" EACH WAY, UP TO 9-INCH THICK SLAB ON GRADE WITH #4 @ 16" EACH WAY TOP AND BOTTOM. 3. LOCATE CONSTRUCTION JOINTS UNDER PARTITIONS OR ON COLUMN LINES. 4. PROVIDE CONTROL JOINTS AT A MAXIMUM SPACING OF 20-FEET EACH WAY IN BETWEEN. PROVIDE CONTROL JOINTS AT ALL RE- ENTRANT CORNERS. 5. SUBMIT A JOINTING PLAN TO ARCHITECT FOR REVIEW. 6. AT STRUCTURAL SLAB, EXTEND ADDED BAR 24-INCHES INTO SLAB. AT CONTRACTOR'S OPTION, FORMSAVER IS ACCEPTABLE. 7. OVEREXCAVATE TO A DEPTH OF 12 INCHES BELOW BOTTOM OF FOUNDATION, MOISTURE -CONDITION, PROCESS, AND RECOMPACT TO 90 PERCENT PER GEOTECHNICAL RECOMMENDATIONS FOR SHALLOW FOUNDATIONS. THIS NOTE APPLIES TO NON PILE SUPPORTED SLABS ON GRADE ONLY. 8. VAPOR RETARDER IS REQUIRED ONLY AT INTERIOR SLABS ON GRADE. TYPICAL SLAB ON GRADE EDGE SCALE: NTS 0 12/10/20241 LPD I DJP I AE I ISSUED FOR BID No. DATE DSN CHK APP REVISION SOG TOOLED ISOLATION JOINT SOG TERMINATE REINF AT JOINT ISOLATION JOINT (IJ) BOND BREAKER SAWCUT QUARTER OF SOG THK SOG CONTROL JOINT (CJ) SLAB ON GRADE JOIN-r(z DISCONTINUOUS AT INTERSECTION WITH PERPENDICULAR JOI ry U U (2) #4 X 4'-0" AT N MID -DEPTH M (2) #4 CONT, LAP 2'-6", HOOK AT ENDS CJ INTERSECTION DESIGNED BY: L. DOWELL DRAWN BY: R. MUNRO CHECKED BY: D. PRINDLE APPROVED BY: A. ESPARZA TERMINATE REINF AT JOINT SAWCUT QUARTER OF SOG THK ' -III III I III 3/4" O X 2'-0" SMOOTH DOWEL, CENTER IN SLAB, MATCH SOG REINF SPCG CONSTRUCTION JOINT (CJ) (2) #4 X 4'-0" AT MID - DEPTH SOG RE-ENTRANT CORNER RE-ENTRANT CORNER TYPICAL - SLAB ON GRADE DETAILS SCALE: NTS L S MIN 1" 3" 2" 6" 4if 911 6" 18" STRUC WALL \ STRUC SLAB I r' I 3/4"x3 — — 1 /2"x0'-6" KEYED JT S S N i i w F_ O z w w cl) NOTES: 1. DO NOT MOVE OR CUT REINFORCING BARS. C, #4 X 2'-0" � WHERE NO U CJ OCCURS r--71 I I I I 2'-0" MATCH SIZE AND SPCG OF SOG, SEE NOTE 6 SOG, REINF NOT SHOWN WATERSTOP PER ARCH SLAB/WALL INTERSECTION 2. REQUIRED SPACING BETWEEN PENETRATIONS SHALL BE CHOSEN USING THE LARGER PENETRATION. 3. FOR LARGER SLAB ON GRADE PENETRATIONS OR FOR PENETRATIONS SPACED TOO CLOSE TO EACH OTHER, REINFORCE PER'TYPICAL CONCRETE WALL OR SLAB OPENING DETAIL'. TYPICAL SLAB ON GRADE OPENING DETAIL SCALE: NTS ESPARZ �F WA SDI CIO S�iO 2 16264 ALE�� G1�� NAL E� 15/Nov/202 SOG EDGE .5r.RIDE BRT General Engineering Consultant SUBMITTED BY: DATE: REVIEWED BY: R. PARGAS 12/10/2024 J. ALTCHECH FILL IN W/ CONC AFTER FORMS ARE REMOVED U AT COLUMN CJ a _ a.a AT PILASTER #4 EDGE BAR, TYP CJ 9' MAX. (2) #5 CONT, FILL IN W/ LAP 2'-6" CONC AFTER 3/4" CHAMFER FORMS ARE #4 @ 12" REMOVED X a CONC 75 SLAB, N SEE NOTE 2 a a #5 CONT, NOTES: LAP 2'-6" 1. SEE ARCHITECTURAL DRAWINGS FOR CURB DIMENSIONS AND LOCATIONS. 2. MINIMUM THICKNESS OF CONCRETE ELEMENT WHERE THIS DETAIL APPLIES IS 4 INCHES. 3. FOR CURBS ON SLAB ON METAL DECK, PLACE HOOK AND CONTINUOUS BOTTOM BAR AT BOTTOM OF FLUTE. 4. INFORM THE STRUCTURAL ENGINEER WHERE CURB IS SHOWN THAT FALLS OUTSIDE OF THE LIMITS OF THIS DETAIL. SCALE: Q J NTS Q FILENAME: co w co J S 1-BT120-S-v2020 SouNDT ANSI1 CONTRACT No.: 1Y i71i RTA/CN 0205-24 DATE: SUBMITTAL DATE: 12/10/2024 12/10/2024 TYPICAL CONCRETE CURB DETAILS SCALE: NITS STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT 105 STRUCTURAL TYPICAL FOUNDATION DETAILS 1 R-4332295 DEVELOPMENT ENGINEERING msippo 11 /25/2025 DRAWING NO.: BT120-SGY401 FACILITY ID: BT120 SHEET No: REV: 373 0