Loading...
HomeMy WebLinkAboutR-43323020 N 0 N > 0 N m co U w C� I z a ry ~I 0 n ry I U) m 0 I 0 co co a � o �I &i a o � 0 N 0 0 co m 2/3 BEAM DEPTH FOR - W18 AND LARGER. BEAM DEPTH FOR W16 AND SMALLER (12" MINIMUM) TYP BM TO GIRDER CONNECTION BM MAY SLOPE --//' — —�� PER PLAN ----- 1/4 GIRDER SIZE VARIES, SEE PLAN CJP NOTE 1 WELD NOTE 2 N:1 SEE WELD N:1 NOTE 1 WELD NOTES: 1. WELD SIZE = 1/2 PLATE THICKNESS (MIN 5/16" FOR GRADE 50 STEEL) O O 2. PLATE THICKNESS = BEAM FLANGE THICKNESS + 1/4" PLATE WIDTH = BEAM FLANGE WIDTH -1" GRADE SHALL MATCH BEAM CJP TYP NOTES: 1. WHERE BEAM SLOPES, IN LIEU OF PROVIDING TOP PLATE, PROVIDE PLATES PER DETAIL "AT SLOPING BEAM". —�� BEAM DEPTH LESS THAN GIRDER DEPTH BEAM DEPTH EQUALS GIRDER DEPTH ADDL PLS TO MATCH BM FLG WIDTH AND THK + 1/4" SEE WELD NOTE 1 O .I O - GIRDER AT SLOPING BEAM CANTILEVER BEAM MOMENT CONNECTION SCALE: NTS SCHEDULE A BEAM SIZE PLATE THICKNESS WELD SIZE "A" NUMBER OF BOLTS W 8 5/16" 1/4" 2 W 10 5/16" 1/4" 2 W 12 3/8" 5/16" 3 W 14 3/8" 5/16" 3 W 16 3/8" 5/16" 4 W 18 3/8" 5/16" 5 W 21 3/8" 5/16" 6 W24 3/8" 5/16" 6 W27 3/8" 5/16" 7 W 30 7/ 16" 3/8" 8 W 33 7/ 16" 3/8" 9 W 36 1/2" 7/16" 10 1. ALL FIELD BOLTED CONNECTIONS SHALL BE MADE WITH 7/8" DIAMETER BOLTS, UNO. 2. BOLT SIZE AND NUMBER SHALL BE TYPICAL FOR ALL CONDITIONS, UNLESS DETAILED OTHERWISE. ALL BOLTS SHALL BE A325 BOLTS. 3. ALL BEAM TO COLUMN, CANTILEVER BEAM AND COLLECTOR BEAM CONNECTIONS SHALL BE SLIP -CRITICAL (SC) BOLTS. SEE STRUCTURAL NOTES. 4. PLATES SHALL HAVE Fy = 50 KSI MINIMUM. STANDARD BEAM CONNECTION SCHEDULES SCALE: NTS SEE SCHEDULE C FOR C PLATE THICKNESS C AND WELD SIZE FITTED COLUMN STIFFENERS, TOP & BOTTOM, ALIGN WITH FLANGES OF BEAMS. PLATE THICKNESS = BEAM FLANGE PLUS 1/4", TYP SHEAR PLATE SEE SCHEDULE C O OO O OO O � Film IIVISA SEE SCHEDULE C FOR NUMBER, SIZE AND TYPE OF BOLTS NOTE: 1. WHERE FRAMING MEMBERS ARE DIFFERENT NOMINAL SIZES, FITTED STIFFENER SHALL BE SLOPED TO ALIGN WITH FLANGES. CJP TOP & BOT FLANGE, TYP BEAM, SEE PLAN COLUMN BEAM TO COLUMN FLANGE MOMENT CONNECTION SCALE: NTS SCHEDULE C - SHEAR PLATES AT MOMENT CONNECTIONS BEAM SIZE PLATE THICKNESS WELD SIZE "C" NUMBER OF BOLTS W 10 5/16" 3/16" 2 W 12 3/8" 5/16" 3 W 14 3/8" 5/16" 3 W 16 3/8" 5/16" 4 W 18 3/8" 5/16" 5 W21 3/8" 5/16" 6 W24 3/8" 5/16" 7 W27 1/2" 3/8" 14 (2 VERT ROWS) W30 1/2" 3/8" 16 (2 VERT ROWS) STANDARD BEAM CONNECTION SCHEDULES SCALE: NTS PL 3/8 BRACE, L3X3X1/4 TYP BEAM, ' (FOR LENGTHS GREATER SEE PLAN THAN 10' USE L4X4X1/4 UNO) SEE PLAN FOR LOCATION PL 3/8 (3) SIDES _TYP EE 3/16 LENGTH TYP 3/16 INDICATES DIRECTION OF BRACE CONNECTION TO THE BOTTOM OF BEAM BM END WHERE OCCURS I11-7 1 2 BM WHERE 0° OCCURS 3/16 I 3116 I 3/16 I -- BM I I I I I I P L 1 /4 I (2) 5/8" DIA BOLT z O (2) PL 1/4, SEE DET'L a J J a 1„ 11/2" N 04 04 2 1/2" PL DETAIL NOTES: 1. PROVIDE A 3/16" CAP PLATE AT ALL BEAMS UNLESS NOTED OTHERWISE. TYPICAL HSS BEAM TO HSS BEAM SHEAR CONNECTION SCALE: NTS BEAM, SEE PLAN BEAM, SEE PLAN TYPICAL BOTTOM FLANGE BRACE CONNECTION SCALE: NTS DESIGNED BY: L. DOWELL o-SPARZA Oi of WA DRAWN BY:r.RIDE R. MUNRO w C� z CHECKED BY: N BRT General Engineering Consultant `O 2 16264 D. PRINDLE ��� U ALEN�`�1��� 0 12/10/2024 LPD DJP AE ISSUED FOR BID APPROVED BY:aL SUBMITTED BY: DATE: REVIEWED BY: No. DATE DSN CHK APP REVISION A. ESPARZA 15/Nov/2024 R. PARGAS 12/10/2024 J. ALTCHECH SCALE: Q J NTS Q FILENAME: W w co J S 1-BT120-S-v2020 SOUNDT ANSI1 CONTRACT No.: 1Y i71i RTA/CN 0205-24 DATE: SUBMITTAL DATE: 12/10/2024 12/10/2024 d w 0 m w Z w a J d OPNG BXH SEE NOTE WAI r L Ld -ISS BM S&FS TYP BEAM WEB PENETRATION SCHEDULE MARK OPNG PLATES 'A' PLATE 'B' REMARKS TxBxL-A WELD TxBxL-B WELD A 4.5" X 2" BARE OPENING B 3" X 2" BARE OPENING NOTES: 1. FOR RECTANGULAR OPENINGS, THE RADIUS OF THE CORNER SHALL BE THE LARGER OF AT LEAST TWICE THE WEB THICKNESS OR 1/2-INCH. 2. FOR FIELD CUT PENETRATIONS REQUIRING REINFORCING, INSTALL REINFORCING PLATES PRIOR TO CUTTING BEAM WEB PENETRATION. 3. CONTRACTOR TO DETAIL CONDUIT IN CONJUNCTION WITH BEAM WEB PENETRATIONS AND ARCHITECTURAL ITEMS. TYPICAL BEAM WEB PENETRATION SCALE: NTS STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT 105 STRUCTURAL TYPICAL STEEL BEAM DETAILS 2 �R-43323021 DEVELOPMENT ENGINEERING msippo 11 /25/2025 DRAWING NO.: BT120-SGY408 FACILITY ID: BT120 SHEET No: REV: 380 0