CODE REVIEW
OWNERS CONTACT INFORMATION
SOUND TRANSIT
401 S. JACKSON STREET, SEATTLE WASHINGTON 98104
PROPERTY INFORMATION
ADDRESS: 780 RAINIER AVENUE SOUTH, RENTON, WA 98055
ZONE CODE: PUBLIC TRANSIT CENTER
LAND USE CODE: 8862 - MISCELLANEOUS - GOVERNMENT
OWNED PROPERTY - TRANSPORTATION - GENERAL
PARCEL NUMBERS
1923059035,1923059063,1923059068,1923059074
LEGAL DESCRIPTION
FOR PARCEL No. 1923059035:
LOT 2 LESS HWY PER DEED #20110812001717 OF RENTON LLA
#LUA-02-025-LLA REC 20020515900009 LOCATED IN NW 1/4 OF
NE 1/4
FOR PARCEL No. 1923059063:
POR OF NW QTR OF NE QTR STR 19-23-05 DAF: BEG AT NE
COR SD
SEC 19 TH N 89-50-24 W ALG N LN SD NE QTR 2179.38 FT TH S
00-09-36 W AT R/A TO SD N LN 510.35 FT TO TPOB TH CONTG S
00-09-36 W 260.0 FT TO NLY MGN OF BN RR R/W (FORMERLY
NP RR R/W) TH N 77-20-05 E ALG SD MGN 414.00 FT TO
ORIGINAL C/L OF BONNEVILLE POWER TRANSMISSION LINE
R/W TH N 00-29-24 W ALG SD C/L 168.13 FT TO PT FROM WCH
TPOB BEARS N 89-50-24 W TH N 89-50-24 W TO TPOB LESS W
0.98 FT THOF
FOR PARCEL No. 1923059068:
POR OF ABANDONED BN RR R/W (FORMERLY NP RR) LY WILY
OF FOLG DESC LN: BEG AT NXN OF ORIGINAL C/L OF
BONNEVILLE POWER TRANSMISSION LINE R/W WITH N LN OF
NE QTR STR 19-23-05 SD PT BEING 1783.40 FT W OF NE COR
SD SEC 19 LESS HWY PER DEED #20110812001717
FOR PARCEL No. 1923059074:
POR OF PUGET SOUND POWER & LIGHT CO R/W IN NE QTR
STR 19-23-05 LY NORTH OF NLY MGN OF S GRADY WAY & WILY
OF FOLG DESC LN - BEG AT NXN OF ORIGINAL C/L OF
BONNEVILLE POWER TRANSMISSION LINE R/W SD PT BEING
1783.40 FT W OF NE COR SD SEC 19 TH S 00-29-24 W ALG SD
C/L TO NLY LN SD S GRADY WAY LESS POR LY WLY OF ELY LN
OF RAINIER AVE S (STATE RD NO 167) & LESS POR
CONDEMNED BY STATE OF WASHINGTON IN SCC NO
861445 LESS HWY PER DEED #20110812001717
AUTHORITY HAVING JURISDICTION:
CITY OF RENTON
ZONING AND LAND USE:
ZONING DISTRICT COMMERCIAL ARTERIAL (CA)
LAND USE DESIGNATION: MIXED USE (CMU)
OVERLAY DISTRICT: URBAN DESIGN DISTRICT D
DEVELOPMENT STANDARDS: RENTON MUNICIPAL CODE (RMC)
TITLE
IV - DEVELOPMENT REGULATIONS
ALLOWABLE BLDG HT: 50 FT
1
PROPOSED STRUCTURES: 28 FT (TRANSIT CENTER), 15 FT
(CORE FACILITY), AND 8 FT (GENERATOR)
THE 15 FT INCREASE IS ALLOWED FOR BUILDINGS WITH PITCH
ROOF FOR 60% OR MORE OF THE STRUCTURE. GIVEN THE
FUNCTION OF THE TRANSIT CENTER AND ITS SUPPORT
FACILITIES, THE INTENT IS TO MEET THE CODE
REQUIREMENTS THROUGH FACADE DESIGN AND
ARTICULATION.
1
06/13/2025
JC
DH
CC
ADDENDUM #1
0
12/10/2024
JC
DH
CC
ISSUED FORBID
No.
DATE
DSN
CHK
APP
REVISION
BUILDING DESCRIPTIONS
1. THE TRANSIT CENTER CONSISTS OF A CENTER
BOARDING PLATFORM THAT HAS 8 BUS BAYS.
BENCHES, WINDSCREENS ARE PROVIDED.
THREE CANOPIES ARE PROVIDED FOR WEATHER
PROTECTION. THE EAST CANOPY IS DESIGNED
TO BE CLEAR FROM OVERHEAD POWER LINE
EASEMENT. WINDSCREEN WALLS ARE 8 FT HIGH
IN BETWEEN OPEN CANOPY COLUMNS.
2. CORE FACILITY IS COMPOSED OF SECURITY,
STORAGE, COMFORT STATIONS, JANITOR
ROOMS, LACTATION ROOM, TELECOM ROOM AND
ELECTRICAL ROOM. IT IS A STEEL FRAMED
STRUCTURE WITH CMU VENEER. INSULATED
PER SEATTLE ENERGY CODE.
0
APPLICABLE CODES AND STANDARDS
2021 IBC (WAC 51-50)
2021 IMC (WAC 51-50)
2021 UPC (WAC 51-56 & 51-57)
2020 NEC (NFPA 70)
2021 WASHINGTON STATE ENERGY CODE (WAC 51-51C)
,,— "— v-w v-- w w w "— v-w v-- v-- w w w v- v-w v-- w
BUILDING/ STRUCTURE AREA:
OPEN STRUCTURES
BUS PLATFORM (SECTOR A, B, C): 9,396 SF
GENERATOR: 470 SF
CORE FACILITY BUILDING: 2,651 SF
0
L
OPEN STRUCTURES
OCCUPANCY IBC SI
BUS PLATFORM:
GENERATOR:
A-3 (303.4 ASSEMBLY GROUP)
WAITING AREAS IN TRANSPORATION TERMINAL
U (312.1 UTILITY AND MISCELLANEOUS GROUP)'
ALLOWABLE HEIGHT ABOVE GRADE PLANE (TABLE 504.3)
L B E- F, C U A -V AB U
PROVIDED: 23 FT (BUS PLATFORM)
11 FT APPROX. (GENERATOR)
1
TOTAL ALLOWABLE BUILDING AREA (506.2)
ALLOWABLE:
6,000 SF, OCC A-3, TYPE VB CONSTRUCTION (NON SPRINKLERED)
9,000 SF, OCC B TYPE VB CONSTRUCTION (NON SPRINKLERED)
5,000 SF, OCC U TYPE VB CONSTRUCTION (NON SPRINKLERED)
w w w w w w w w w w w w w w w w w w w w w w w w
PROVIDED:
BUS PLATFORM - 2,436 SF (SECTOR A), 1,740 SF (B), 5,220 SF (C) < 6,000 1
GENERATOR - 470 SF < 5,000 1
CORE FACILITY BUILDING
1 ALLOWABLE HEIGHT AND AREA (TABLE 504 & 506)
ALLOWABLE HEIGHT (TABLE 504.3): 40 FEET
ALLOWABLE STORIES (TABLE 504.4): 2 STORIES
TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE,
TYPE V-B CONSTRUCTION (NON SPRINKLERED)
OCCUPANCY B: 2 STORIES ALLOWABLE
BUILDING STORY: 1 STORY PROPOSED
BUILDING AREA: 2,651 SF < 9,000 SF (IBC TABLE 506.2)
ALLOWABLE BUILDING AREA, NS, Aa=At + (NS x If). FRONTAGE INCREASE IS
NOT NEEDED FOR THIS ALLOWABLE AREA CALCULATION.
TABLE 1017.2. EXIT ACCESS TRAVEL DISTANCE
ALLOWABLE DISTANCE: 200 FT, A-3 OCCUPANCY, NS.
300 FT, U OCCPANCY, NS.
1
PROVIDED: N/A AT BUS PLATFORM, OPEN STRUCTURE.
37 FT < 300 (GENERATOR ENCLOSURE), U OCC
PER SECTION 1006.2.1 EXCEPTION 3, UNOCCUPIED MECHANICAL ROOMS
AND PENTHOUSES ARE NOT REQUIRED TO COMPLY WITH COMMON
PATH OF EGRESS TRAVEL DISTANCE MEASUREMENT
LIFE SAFETY SITE PLAN
SCALE: 1" = 80'-0"
DESIGNED BY:
C. CHEANG
DRAWN BY: 9849 REGISTERED
J. CHAN AR(C'HII— T
CHECKED BY: CAN LAMCflEANG
D. HOGAN STATE OF WASHINGT
APPROVED BY: SUBMITTED BY:
C. CHEANG R. PARGAS
F)l
80 40 0 80 160
SCALE IN FEET
TABLE 1006.2.1 SPACE WITH ONE EXIT
ALLOWABLE DISTANCE: 100 FEET, OCCUPANT LOAD <30, NS.
PROVIDED: 27 FEET
CONSTRUCTION TYPE: VB
VB SINGLE OCCUPANCY
MINIMUM CONSTRUCTION TYPE PER IBC 2021 & WAC 51-50, SECTION 602,
PER TABLE 601 FIRE -RESISTANCE RATING REQUIREMENTS FOR BUILDING
ELEMENTS:
BUILDING ELEMENTS FOR TYPE VB:
PRIMARY STRUCTURAL FRAME 0 HR
NON -BEARING WALLS AND PARTITION INTERIOR 0 HR
FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS 0 HR
ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS 0 HR
TABLE 602, FIRE SEPARATION BY DISTANCE
EXTERIOR WALLS TYPE VB, 0 HR, DISTANCE EQUAL OR LARGER THAN 10 FT.
FIRE ALARM SYSTEM: 907.2.2 GROUP B 1
NOT PROVIDED
AUTOMATIC SPRINKLER SYSTEM IS NOT PROVIDED PER RMC TITLE IV
SECTION 903.2.4 FOR BUILDING NOT OVER 5,000 SQUARE FEET.
4STm)?IDE
BRT General Engineering Consultant
DATE: REVIEWED BY:
12/10/2024 J. ALTCHECH
0
SCALE: 1 /16" = 1'-0"
SCALE:
Q
w
mrr
AS NOTED
Q
FILENAME:
Cl)
w
C/)
S 1-BT120-A-v2020
z
J
U_
SOUNDTRANSIT
CONTRACT No.:
RTA/OA 0206-19
DATE:
SUBMITTAL DATE:
12/10/2024
12/10/2024
REMARKS:
1. FIRE EXTINGUISHERS ARE LOCATED PER NFPA10
2. PORTABLE FIRE EXTINGUISHERS LOCATED AT ANCILLARY
SPACES - PROVIDE CARBON DIOXIDE FIRE EXTINGUISHERS AT
ALL ELECTRICAL ROOMS.
3. INTERIOR FINISH MATERIALS ARE IN COMPLIANCE WITH FLAME
SPREAD RATING PER CHAPTER 8 2017
MATERIAL FLAME SPREAD RATING
FIRE RETARDANT TREATED WOOD CLASS A
GYP BOARD CLASS A
METAL PANEL CLASS A
CONCRETE CLASS A
CONCRETE MASONRY UNITS CLASS A
CORE FACILITY OCCUPANT LOAD TABLE
NO.
BT120L1200
NAME
SECURITY BLDG
AREA
TYPE
OCC. #
257 SF
69 SF
B
B
3
1
BT120L1201
SEC STORAGE
BT120L1202
LACTATION ROOM
112 SF
B
2
BT120L1203
JANITOR
113 SF
B
2
BT120L1204
OPERATOR RESTROOM
74 SF
B
1
BT120L1205
OPERATOR RESTROOM
74 SF
B
1
BT120L1206
OPERATOR RESTROOM
75 SF
B
1
BT120L1207
OPERATOR RESTROOM
74 SF
B
1
BT120L1208
TELECOM
409 SF
B
5
BT120L1209
ELECTRICAL
351 SF
B
4
BT120L1210
STORAGE 1
450 SF
B
5
BT120L1500
GENERATOR
Not
Enclose
d
TOTAL: 26
# OF OCCUPANTS EXIT
0
DEVELOPMENT ENGINEERING � -�
msippo 11 /25/2025
pi
GENERATOR PAD
SCALE: 1 /16" = 1'-0"
16 8 0 16 32
SCALE IN FEET
�R-4332322
STRIDE BUS RAPID TRANSIT DRAWING NO.:
SOUTH RENTON TRANSIT CENTER BT120-ASZ201
BT105 FACILITY ID:
ARCHITECTURE BT120
SHEET No: REV:
LIFE SAFETY PLAN AND CODE INFORMATION
TRANSIT CENTER 400 1