Loading...
HomeMy WebLinkAboutR-4332349N C'7 co i i w 0 N 0 N > Q 0 N_ m U) U Lu CD �I z ~I n f'yI D m 0 I 0 co 00 2 � a o ~ I Q o co U) 0 N LO m CO SCALE: 3" = 1'-0" FALL PROTECTION ANCHOR SEE ROOF PLAN FOR LOCA7 INSTALL IN ACCORDANCE W MANUFACTURERS INSTRUC' SEAMLESS SPUN ALUMINUM FLASHING RUBBER COLLAR FLASHING TIE -BACK ANCHORED TO CONCRETE STRUCTURE PEI MANUFACTURER INSTRUCTI WEATHER RESISTIVE BARRIER AND AIR BARRIER 1.5" METAL DECK LIFE LINE FALL RESTRAINT ANCHOR SCALE: 1 1/2" = 1'-0" q L c BT120-AEE812 3" DIA. OVERFLOW INSIDE CONDUITE RACEWAY 3" DIA. DOWNSPOUT INSIDE CONDUITE RACEWAY METAL COLUMN COVER, C-1, TYP. DAYLIGHTED OVERFLOW DRAIN WITH METAL INSECT SCREEN CUT HOLE IN COLUMN COVER FOR 4" DIA. CLEANOUT 5" DIA. CLEANOUT COVER CONCRETE PLATFORM NOTE: LOCATE DRAIN CLEANOUT AT COLUMN SIDE CLEAR FROM WINDSCREEN, TVM, OR ANY OBJECTS ON THE PLATFORM FOR ACCESS DOWNSPOUT CLEANOUT BT120-AEX711 NOTES: 1. ROOF PENETRATIONS SHALL HAVE A MIN. 12" CLEARANCE ON ALL SIDES FROM WALLS, CURBS AND OTHER ROOF PENETRATIONS. 2. PENETRATIONS SHALL BE RIGID, ROUND OR SQUARE TUBE AND EXTEND PERPENDICULAR FROM THE ROOF STRUCTURE. 3. TIE -BACK ANCHORS SHALL BE COMPLETELY WATER TIGHT ABOVE ROOF MEMBRANE FLASHING. 4. REFER TO STRUCTURAL DRAWINGS FOR ATTACHMENT AND LOCATION OF TIE -BACK ANCHORS. COLUMN METAL CLADDING FASTENER, BY METAL CLADDING MNF. BRAKE METAL TO SUPPORT LIGHT FIXTURE FASTENER LIGHT FIXTURE COLUMN METAL CLADDING LIGHTING FIXTURE MOUNTING DETAIL 20 GA. - 1.5" META' ROOF SHEATHINC STRUCTURAL COI STANDING SEAM METAL ROOFING GUTTER, C-1, TYF STRUCTURALBE/ 2X WOOD FRAME 3" DIA. DOWNSPOUT BEYOND UPPER GUTTER SCALE: 1 1/2" = 1'-0" LOWER GUTTER @ WINDOW SCALE: 1 1/2" = 1'-0" 0'- 6 1/2" pq GROUND HYDRANT BOX (NON -FREEZE) SCALE: 1 1/2" = 1'-0" BT120-AEE815 SCALE: 1 1/2" = 1'-0" BT120-AEE811 SCALE: 3" = 1'-0" 0 12/10/2024 J.C. D.H. I C.C. I ISSUED FOR BID No. DATE DSN CHK APP REVISION DESIGNED BY: C. CHEANG DRAWN BY: J. CHAN CHECKED BY: D. HOGAN APPROVED BY: C. CHEANG BT120-AEX711 'ANDING SEAM =TAL ROOFING )OF SHEATHING GA. - 1.5" METAL DECK JTTER, C-1, TYP. =TAL FLASHING -EEL CLADDING, C-2 DIA. DOWNSPOUT =YOND =E STRUCT. =TAL SOFFIT PANEL BT120-AEX711 LOCKABLE LID FLUSH WITH ADJACENT CONCRETE SURFACE METAL HYDRANT BOX CONCRETE OUTER CASING PIPE GRAVELS 9849 REGISTERED ARCHIT IDE TNTAN BRT General Engineering Consultant OF WASH INGT SUBMITTED BY: DATE: REVIEWED BY: R. PARGAS 112/10/2024 J. ALTCHECH UPPER GUTTER STRUCTURAL COLUMN BEYOND 3" DIA. UPPER DOWNSPOUT LOWER GUTTER 3" DIA. OVER FLOW DOWNSPOUT OUTRIGGER, SEE STRUCTURAL DWG 3" DIA. DOWNSPOUT DOWNSPOUT DAYLIGHT BELOW METAL SOFFIT UPPER/ LOWER GUTTER ELEVATION SCALE: 1 1/2" = 1'-0" BT120-AEE815 STRUCTURAL COLUMN CUSTOMIZED CRICKET SHEET METAL FLASHING CUSTOMIZED CRICKET OUTLINE UNDER ROOFING EDGES OF STANDING SEAM ROOFING CRICKET DETAIL AROUND COLUMN SCALE: 1 1/2" = 1'-0" SCALE: Q w AS NOTED Q FILENAME: W w U) J S 1-BT120-A-v2020 z J SOUNDTRANSIT CONTRACT No.: RTA/CN 0205-24 DATE: SUBMITTAL DATE: 12/10/2024 12/10/2024 STANDING SEAM P"" " ROOF SHEATHING METALSTRUCTUR METAL FLASHING METAL CLIP, TYP. STRUCTURALBEA & METAL BRACKET SOFFIT PANEL CANOPY DETAILS - RAKE CONDITION SCALE: 3" = 1'-0" LOWER GUTTER @ END CANOPY SCALE: 1 1/2" = 1'-0" STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 ARCHITECTURE CANOPY DETAILS PLATFORM BT120-AEX712 STANDING SEAM METAL ROOFING 20 GA. - 1.5" METAL DECK GUTTER, C-1, TYP. METAL FLASHING STEEL CLADDING, C-2 3" DIA. DOWNSPOUT BEYOND SEE STRUCT. METAL SOFFIT PANEL BT120-AEX712 R-4332349 DEVELOPMENT ENGINEERING msippo 11 /25/2025 DRAWING NO.: BT120-AED900 FACILITY ID: BT120 SHEET No: REV: 427 0