HomeMy WebLinkAboutR-4332387►- 7 O N M N O N LO N co co W 0 N 0 N Q O N H m U) U w (D I H (n Z Q ry H I 0 n ry I D m 0 I 0 co 00 LO co 0I Q 0 CO c) -_ 9,-n„ (TYPE B) TYPICAL PARTITION1 MARK STUD WIDTH PRTN WIDTH Design STC B 6" 1 6 5/8" 50 (TYPE A) TYPICAL PARTITION MARK STUD WIDTH PRTN WIDTH Design STC A 6" 71 /4" 50 (TYPE Al) TYPICAL PARTITION @ CONIC CURB MARK STUD WIDTH PRTN WIDTH Design STC Al 6" 71/4" 50 GENERAL PARTITION NOTES: 1. PARTITIONS ARE DISTINGUISHED ON FLOOR PLANS BY SYMBOL DESIGNATION, GRAPHIC DESIGNATION OR A COMBINATION OF BOTH DESIGNATIONS. SOME PARTITION TYPES SHOWN ON THIS SHEET MAY NOT BE USED ON THIS PROJECT. 2. ALL WALLS NOT DESIGNATED WITH A GRAPHIC OR TAG TO BE TYPE Al. IF UNCLEAR CONTACT ARCHITECT. 3. SOUND TRANSMISSION CLASS (STC) IS A RATING SYSTEM THAT DESCRIBES THE ABILITY OF AN ASSEMBLY TO REDUCE THE TRANSMISSION OF SOUND. CONFIGURE SOUND -RATED WALL ASSEMBLIES ACCORDING TO THE MINIMUM REQUIREMENTS STIPULATED IN THE STC TESTS LISTED. STC RATINGS LISTED ARE BASED ON LABORATORY TESTING AND ARE NOT INDICATIVE OF RESULTS IN FIELD. 4. REFER TO SECTION 09 29 00 FOR ACOUSTIC SEALANTS. 5. SOUND ATTENUATION BATTS (SAB) ARE SPECIFIED IN SECTION 09 29 00. WHERE SAB ARE INDICATED, THEY SHALL EXTEND CONTINUOUSLY FROM FLOOR TO STRUCTURE ABOVE. 6. PARTITIONS ARE INDICATED WITH CONVENTIONAL GYPSUM WALLBOARD U.N.O.; UPGRADE TO PREMIUM TYPES OF WALLBOARD (I.E., MOISTURE -RESISTANT, TILE -BACKER BOARD, ACOUSTICALLY ENHANCED, ETC.) BASED ON THEIR LOCATION AND ACCORDING TO REQUIREMENTS OF SECTION 09 29 00. 7. "LINE OF STRUCTURE" INDICATED FOR EACH PARTITION IS DIAGRAMATIC ONLY AND DOES NOT INDICATE EXACT CONSTRUCTION CONDITIONS OR GEOMETRY. 8. ALL DIMENSIONS ARE FROM FACE TO FACE, OR CENTERLINE TO CENTERLINE, U.N.O. REFER TO PARTITION MATRICES FOR PARTITION WIDTH DIMENSIONS UNLESS INDICATED TO BE SHOWN ON PLAN. 9. REFER TO THE TOILET ACCESSORIES SHEET AND CASEWORK SHEET FOR MOUNTING DETAIL INFORMATION. PARTITION TYPE LEGEND XO — PARTITION TYPE R-4332387 DEVELOPMENT ENGINEERING msippo 11 /25/2025 DESIGNED BY: SCALE: DRAWING NO.: C. CHEANG Q w NTs STRIDE BUS RAPID TRANSIT BT120-AES910 DRAWN BY: 9849 FREGIS1ERED U FILENAME: SOUTH RENTON TRANSIT CENTER A. DOMINGO T w RIDE c/) J S1-BT120-A-v2020 BT105 FACILITY ID: CHECKED BY: IN N BRT General Engineering Consultant z " S UNDTRANSIT CONTRACT No.: BT120 D. HOGAN STATE OF WASH INGT RTA/CN 0205-24 ARCHITECTURE SHEET No: REV: 0 12/10/2024 J.C. D.H. C.C. ISSUED FOR BID APPROVED BY: SUBMITTED BY: DATE: REVIEWED BY: DATE: SUBMITTAL DATE: PARTITION TYPES CORE FACILITY 465 0 No. DATE DSN CHK APP REVISION C. CHEANG R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024