Loading...
HomeMy WebLinkAboutR-4332388co co O W 0 N 0 N Q 0 N_ H m co w cD �I z Q ry I 0 n Q ry I D m of 0 co 00 LO a o � I LO Q N M D N 0 0 LO cy) m W 16 X 45 TRANSLU( WINDOW C BT120-AE1 HSS6X4 METAL VE BLADE FE ('-E� BT120-AES "1`41111K F TRANSLUCENT PANEL -ENLARGED ELEVATION ( q SCALE: 3/8" = V-0" 2.9 .J I IL CMU VENEER F BT120-AES911 F BT120-AI D900 SECTION @ TRANSLUCENT PANEL SCALE: 3/8" = V-0" 2.9 BT120-APP221 2.8 I 2.0 TRANSLUCENT PANEL SYSTEM 2.8 W2 Cl: 8' H STEEL CMU VENEER PICKET RAILING 1/2" I M 31/2"� SEE NOTE —j 1 BT120-AED909 NOTE: ARRANGE VERTICAL RAILING MEMBER SO THAT THE ARRANGMENT WOULD HAVE EQUAL SPACING AT BOTH VERTICLE POSTS SECTION @ PICKET FENCE BT12C 2.5 17'-4" 17'-3" 2.7 I I I D -AES911 I I I 17r\ I I BT120-AID909 I 2.5 � BT120-AES911 TRANSLUCENT PANEL - ENLARGED ELEVATION SCALE: 3/8" = 1'-0" rD""*'� BT120-AI D909 2.6 ENLARGED PLAN @ TRANSLUCENT TYPE II SCALE: 3/8" = V-0" 2.E 2.11) 2.0 2.113 2.A STEEL FRAMING TO C CONNECT TO ROOF BEAM WITH VERTICAL STEEL BT120-AES911 STUDS, TYP. REFER TO STRUCTURAL ROOF CE1 F FRAMING PLAN gT120-AID909 BT120-AI D900 MIN 6"H STEEL FRAMINGS @ 24" OC MAX FOR SOFFIT ATTACHMENT 3/4" THICK BASE PLATE ON TOP OF CONCRETE SIDEWALK, E APPLY GROUT TO LEVEL BASE PLATE AS NEEDED. CONNECT BT120-AES911 VERTICAL BLADE PICKETS TO TOP AND BOTTOM STEEL PLATES WITH DOUBLE SIDED FILLET WELDS, TYP SECTION @ TRANSLUCENT WINDOW & FENCE( ---I CORE FACILITY -ROOF 41'-2" CORE FACILITY 28'-2" BT120-APD223 R13 INSULAT GYP BOARD RIGID INSULT PLYWOOD SF BRICK VENEE AIR BARRIER 2.5 2.7 JAMB DETAIL @ TRANSLUCENT WINDOW TYPE II FORMED METAL WALL PANEL CORE FACILITY -ROOF 41'-2" TRANSLUCENT 'ANEL SYSTEM, TYP. METAL CANOPY CORE FACILITY 28'-2" ACCENT CMU, TYP. TRANSLUCENT PANEL SYSTEM, TYP. EXTERIOR WALL ASSEMBLY, TYP. METAL CANOPY BELOW METAL CANOPY SUPPORTS, TYP. SCALE: 1" = 1'-0" BT1 20-APD222 SCALE: 3/8" = 1'-0" SCALE: 1 1/2" = 1'-0" BT120-AES 911 DESIGNED BY: SCALE: DRAWING NO.: C. CHEANG Q w AS NOTED STRIDE BUS RAPID TRANSIT DRAWN BY: 9849 REGISTERED T)?IDEU FILENAME: SOUTH RENTON TRANSIT CENTER BT120-AES911 A. DOMINGO ARCS w J S1-BT120-A-v2020 BT105 FACILITY ID: Z) r=" CHECKED BY: N N BRT General Engineering Consultant J '� SpUNDTRAN5IT CONTRACT No.: ARCHITECTURE BT120 D. HOGAN STATE OFWASHINGT RTA/CN 0205-24 SHEET No: REV: 0 12/10/2024 J.C. D.H. C.C. ISSUED FOR BID APPROVED BY: SUBMITTED BY: DATE: REVIEWED BY: DATE: SUBMITTAL DATE: TRANSLUCENT WINDOW TYPES No. DATE DSN CHK APP REVISION C. CHEANG R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 CORE FACILITY 466 0