Loading...
HomeMy WebLinkAboutR-4332408N co C'7 O W 0 N 0 N > 0 N m W U W 0 W z ry ~I 0 n I W D m 0 I 0 co co 2� a o L I co 4 co 'zj- D 0 N LO m m 8 GAGE HANGER WIRE WITH 3 TIGHT TURNS WITHIN 1 1/2"' FRAME AROUND OPENING PREMANUFACTURED CEILING ACCESS, PANEL WITH RECESSED DOOR SECURE TO CHANNELS PER MANUFACTURER 0 0 0 FINISH FLUSH WITH GROMMET/LATCH ADJACENT CEILINr, GYPSUM BOARD CASING BEAD ALL THE WAY AROUND 5/8" GYPSUM WALL BOARD 7/8" X 26 GAGE MINIMUM FURRING CHANNELS ACCESS PANEL - CEILING MOUNTED SCALE: 3" = 1'-0" NOTE: PROVIDE 2 - 12 GA. HANGERS FROM FIXTURE HOUSING TO CEILING SYSTEM HANGER OR TO STRUCTURE ABOVE. THESE MAY BE SLACK WIRES. WIRE TO BE STRAIGHT, WITHOUT EXTRANEOUS KINKS OR BENDS AND TOLERATE A 200 LB. PULL WITHOUT STRETCHING OR SHIFTING THE SUSPENSION CLIP. CLIP EACH FIXTURE TO GRID (CAPACITY OF EA. CLIP = 100% FIXTURE WEIGHT ACTING IN ANY DIRECTION) 12 GA. HANGERS @ 48" OC AND WITHIN 3" OF ANY FIXTURE 2 BT120-AID901 WHERE LIGHT FIXTURES ARE IN TANDEM, COMMON HANGERS MAY BE USED. LIGHT FIXTURE 19 F-MMMOT-.1 ED COMPRESSION POST WHERE REQ'D LOCATE @12' OC EACH DIRECTION SUSPENSION WIRE, SPLAY 4 -WAYS AND PLACE @ 45 DEGREES TO HORIZONTAL PARALLEL OF CEILING 'T'S 1/4" 0 BOLT MIN. CROSS CEILING RUNNER'T' @2'-0" OC MIN. IVI/'111V IxuIJNER'T' @4'-0" OC MIN. TYP. SUSPENDED GRID SCALE: 1 /8" = V-0" 0 12/10/2024 J.C. D.H. I C.C. I ISSUED FOR BID No. DATE DSN CHK APP REVISION HANGER WIRE @ ALL CORNERS TO STRUCTURE 1 1/2" CARRYING CHANNEL FRAMING ALL SIDES CONNECT TO ADJACENT MAIN RUNNER SEE REFLECTED CEILING PLAN FOR LOCATION & DIMENSION ACCESS PANEL - INLAY SCALE: 12" = 1'-0" ACCESS PANEL MOUNTING FLANGE TOP OF STRUCTURE SEE WALL TYPES FOR DETAIL MTL STUD FRAMING BRACED TO ROOF FRAMING SUSPENDED MTL CEILING FRAMING BRACED AT PARTITION, TYP. U BLKG, TYP. AT CEILING PERIMETER 5/8"THK GWB @ PARTITION & CEILING NOTE: SUSPENDED CEILING TO BE RATED AS REQUIRED TYP. TYP. GWB SUPPORT SCALE: 1 /8" = 1'-0" #12 GA HANGER WIRE #12 AWG TIE WIRE (45 (VERT.) @ 4 CORNERS DEGREE DIAGONAL) AT 4 CORNERS % MINIMUM 4 TURNS WITHIN FIRST 1-1/2" \�15 (VERTICAL) � D 4S BT120-AID901 CADDY #515 T-BAR CLIP FOR SECURING FIXTURE TO T-BAR GRID (4 PER FIXTURE) NOTE: ALL HANGER AND THE WIRES SHALL BE ANCHORED TO BUILDING STRUCTURAL MEMBERS. TYP. RECESSED LUMINAIRE SCALE: 1 /8" = V-0" DESIGNED BY: C. CHEANG DRAWN BY: J. CHAN CHECKED BY: D. HOGAN APPROVED BY: C. CHEANG T-BAR GRID (TYPICAL) TIE WIRE LIGHTING i FIXTURE TIE WIRE PLAN \ VIEW rt5� 9849 REGISTERED ARCHITC1 . 11 STATE OF WASH IN SUBMITTED BY: R. PARGAS WALL AS SCHEDULED TEK SCREW 18" OC CEILING --- FRAME CONCEALED BY FEATHERED JOINT COMPOUNDIS EXTRUDED FLEXIBLE GASKET CONTINUOUS EXTRUDED ALUMINUM FRAME SUSPENDED/ ISOLATED GWB SCALE: 6" = 1'-0" TOP OF STRUCTURE SEE WALL TYPES FOR DETA MTL STUD FRAMING BRACE[ TO ROOF FRAMING 3/4" MIN CLEARANCE - (PANEL FREE TO SLIDE) iuui iuui ACOUSTICAL CEILING TILE - 5/8" GWB BOTH SIDES NOTE: SUSPENDED CEILING BE RATED AS REQUIRED TYI ACOUSTICAL CEILING SUPPORT SCALE: 3" = 1'-0" SEE A/BT120-AID901 FOR SIMILAR INFORMATION 4-WAY - 450 DIAGONAL 12 GA WIRE BRACING @ 8'-0" OC x 12'-0" & COMPRESSION STRUT (10 GA WIRE IF CEILING IS SUPPORTING PARTITIONS) WALL LINE - �T 00 I o N � o N 0 N 0 1 N 4'-8" O N MAX _ 0 N WALL LINE SUSPENDED 2X4 GRID SCALE: 1/4" = 1'-0" F)l A 97120-AID901 00 Q U) (D wzlY w zc~n _ LL J Ucod �Co1-- _0It 00 � __0 Q °0 (D L N () 4fTmRIDE BRT General Engineering Consultant DATE: REVIEWED BY: 12/10/2024 J. ALTCHECH r TYP. SUSPENSION WIRE STRUCTURE SCALE: 1/4" = 1'-0" TYP. ACT TRIM SCALE: 1 /8" = 1'-0" DF STRUCTURE NALL TYPES FOR DETAIL :TUD FRAMING BRACED JOF FRAMING JSTICAL CEILING TILE, TYP. HK GWB ON MTL FRAMING 4-WAY - 450 DIAGONAL 12 GA WIRE BRACING @ 8'-0" OC x 12'-0" & COMPRESSION STRUT (10 GA WIRE IF CEILING IS SUPPORTING PARTITIONS) FIRST BRACING POINT FROM WALL WALL LINE 21-011 CROSS 'T'-BAR TYP. WU o O� - m 12 GA VERTICAL HANGER WIRES @ 4'-0" OC EACH WAY MAIN 'T' BAR WALL LINE UNSUPPORTED LENGTH OF T-BAR. 8" MAX. OR 1/4" WHICHEVER IS LESS. SUSPENDED 2X2 GRID r SCALE: 1/4" = 1'-0" SCALE: Q w AS NOTED Q FILENAME: W w U) S 1-BT120-A-v2020 Z J J SOUNDTRANSIT 0 RCN T RTA/02 05-24 DATE: SUBMITTAL DATE: 12/10/2024 12/10/2024 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 ARCHITECTURE DETAILS CORE FACILITY R-4332408 DEVELOPMENT ENGINEERING msippo 11 /25/2025 DRAWING NO.: BT120-AID901 FACILITY ID: BT120 SHEET No: REV: 486 0