8 GAGE HANGER WIRE
WITH 3 TIGHT TURNS
WITHIN 1 1/2"'
FRAME AROUND OPENING
PREMANUFACTURED CEILING ACCESS,
PANEL WITH RECESSED DOOR SECURE
TO CHANNELS PER MANUFACTURER
0 0 0
FINISH FLUSH WITH GROMMET/LATCH
ADJACENT CEILINr,
GYPSUM BOARD CASING BEAD
ALL THE WAY AROUND
5/8" GYPSUM WALL BOARD
7/8" X 26 GAGE MINIMUM
FURRING CHANNELS
ACCESS PANEL - CEILING MOUNTED
SCALE: 3" = 1'-0"
NOTE:
PROVIDE 2 - 12 GA. HANGERS FROM FIXTURE HOUSING TO
CEILING SYSTEM HANGER OR TO STRUCTURE ABOVE. THESE MAY
BE SLACK WIRES.
WIRE TO BE STRAIGHT, WITHOUT EXTRANEOUS KINKS OR BENDS
AND TOLERATE A 200 LB. PULL WITHOUT STRETCHING OR
SHIFTING THE SUSPENSION CLIP.
CLIP EACH FIXTURE TO GRID (CAPACITY OF EA. CLIP = 100%
FIXTURE WEIGHT ACTING IN ANY DIRECTION)
12 GA. HANGERS @
48" OC AND WITHIN 3"
OF ANY FIXTURE
2
BT120-AID901
WHERE LIGHT FIXTURES
ARE IN TANDEM, COMMON
HANGERS MAY BE USED.
LIGHT
FIXTURE
19 F-MMMOT-.1 ED
COMPRESSION POST
WHERE REQ'D
LOCATE @12' OC
EACH DIRECTION
SUSPENSION WIRE,
SPLAY 4 -WAYS AND
PLACE @ 45 DEGREES
TO HORIZONTAL
PARALLEL OF CEILING
'T'S
1/4" 0 BOLT MIN.
CROSS CEILING
RUNNER'T' @2'-0"
OC MIN.
IVI/'111V IxuIJNER'T' @4'-0" OC MIN.
TYP. SUSPENDED GRID
SCALE: 1 /8" = V-0"
0 12/10/2024 J.C. D.H. I C.C. I ISSUED FOR BID
No. DATE DSN CHK APP REVISION
HANGER WIRE
@ ALL
CORNERS TO
STRUCTURE
1 1/2" CARRYING
CHANNEL FRAMING ALL
SIDES CONNECT TO
ADJACENT MAIN RUNNER
SEE REFLECTED CEILING PLAN
FOR LOCATION & DIMENSION
ACCESS PANEL - INLAY
SCALE: 12" = 1'-0"
ACCESS
PANEL
MOUNTING
FLANGE
TOP OF STRUCTURE
SEE WALL TYPES FOR DETAIL
MTL STUD FRAMING BRACED
TO ROOF FRAMING
SUSPENDED MTL CEILING
FRAMING BRACED AT
PARTITION, TYP.
U
BLKG, TYP. AT CEILING
PERIMETER
5/8"THK GWB @
PARTITION & CEILING
NOTE: SUSPENDED CEILING TO
BE RATED AS REQUIRED TYP.
TYP. GWB SUPPORT
SCALE: 1 /8" = 1'-0"
#12 GA HANGER WIRE #12 AWG TIE WIRE (45
(VERT.) @ 4 CORNERS DEGREE DIAGONAL)
AT 4 CORNERS
% MINIMUM 4 TURNS
WITHIN FIRST 1-1/2"
\�15 (VERTICAL)
� D
4S BT120-AID901
CADDY #515 T-BAR CLIP FOR
SECURING FIXTURE TO T-BAR
GRID (4 PER FIXTURE)
NOTE:
ALL HANGER AND THE WIRES
SHALL BE ANCHORED TO BUILDING
STRUCTURAL MEMBERS.
TYP. RECESSED LUMINAIRE
SCALE: 1 /8" = V-0"
DESIGNED BY:
C. CHEANG
DRAWN BY:
J. CHAN
CHECKED BY:
D. HOGAN
APPROVED BY:
C. CHEANG
T-BAR GRID
(TYPICAL)
TIE WIRE
LIGHTING
i FIXTURE
TIE WIRE
PLAN \
VIEW rt5�
9849 REGISTERED
ARCHITC1 .
11
STATE OF WASH IN
SUBMITTED BY:
R. PARGAS
WALL AS
SCHEDULED
TEK SCREW 18" OC
CEILING ---
FRAME CONCEALED BY
FEATHERED JOINT
COMPOUNDIS EXTRUDED
FLEXIBLE GASKET
CONTINUOUS
EXTRUDED ALUMINUM
FRAME
SUSPENDED/ ISOLATED GWB
SCALE: 6" = 1'-0"
TOP OF STRUCTURE
SEE WALL TYPES FOR DETA
MTL STUD FRAMING BRACE[
TO ROOF FRAMING
3/4" MIN CLEARANCE -
(PANEL FREE TO SLIDE)
iuui iuui
ACOUSTICAL CEILING TILE -
5/8" GWB BOTH SIDES
NOTE: SUSPENDED CEILING
BE RATED AS REQUIRED TYI
ACOUSTICAL CEILING SUPPORT
SCALE: 3" = 1'-0"
SEE A/BT120-AID901 FOR SIMILAR INFORMATION
4-WAY - 450 DIAGONAL 12 GA WIRE BRACING @
8'-0" OC x 12'-0" & COMPRESSION STRUT (10 GA
WIRE IF CEILING IS SUPPORTING PARTITIONS)
WALL LINE
- �T
00
I
o
N
�
o
N
0
N
0
1
N
4'-8"
O
N
MAX
_
0
N
WALL LINE
SUSPENDED 2X4 GRID
SCALE: 1/4" = 1'-0"
F)l
A
97120-AID901
00
Q
U) (D
wzlY
w
zc~n
_ LL J
Ucod
�Co1--
_0It
00 �
__0
Q °0
(D L
N ()
4fTmRIDE
BRT General Engineering Consultant
DATE: REVIEWED BY:
12/10/2024 J. ALTCHECH
r
TYP. SUSPENSION WIRE
STRUCTURE
SCALE: 1/4" = 1'-0"
TYP. ACT TRIM
SCALE: 1 /8" = 1'-0"
DF STRUCTURE
NALL TYPES FOR DETAIL
:TUD FRAMING BRACED
JOF FRAMING
JSTICAL CEILING TILE, TYP.
HK GWB ON MTL
FRAMING
4-WAY - 450 DIAGONAL 12 GA WIRE BRACING @
8'-0" OC x 12'-0" & COMPRESSION STRUT (10 GA
WIRE IF CEILING IS SUPPORTING PARTITIONS)
FIRST BRACING POINT FROM WALL
WALL LINE 21-011 CROSS
'T'-BAR
TYP.
WU
o O�
- m
12 GA
VERTICAL
HANGER
WIRES @
4'-0" OC
EACH WAY
MAIN 'T' BAR
WALL LINE UNSUPPORTED LENGTH OF T-BAR. 8" MAX.
OR 1/4" WHICHEVER IS LESS.
SUSPENDED 2X2 GRID r
SCALE: 1/4" = 1'-0"
SCALE:
Q
w
AS NOTED
Q
FILENAME:
W
w
U)
S 1-BT120-A-v2020
Z
J
J
SOUNDTRANSIT
0
RCN T
RTA/02 05-24
DATE:
SUBMITTAL DATE:
12/10/2024
12/10/2024
STRIDE BUS RAPID TRANSIT
SOUTH RENTON TRANSIT CENTER
BT105
ARCHITECTURE
DETAILS
CORE FACILITY
R-4332408
DEVELOPMENT ENGINEERING
msippo 11 /25/2025
DRAWING NO.:
BT120-AID901
FACILITY ID:
BT120
SHEET No: REV:
486 0