Loading...
HomeMy WebLinkAboutR-4332417N co ('7 O i W O N 0 N > O N m U) W (D I H z ry ~I 0 n I m 0 I 0 co co 2� a o co .. Q NT co U) 0 N LO co m RESTROOMS 1 R" ti z WALL MOUNTED 16"-18" URINAL COAT HOOK (TA-8) SINK W/ UBP (TA-10) 1/4" MAX 13 1/2" MIN. MIRROR W/ SHELF SOAP DISPENSER (TA -IR" MIN 36" STAINLESS STEEL GRAB BAR (TA-6) 1 \ m R SIDE REAR GRAB BAR 16" - 18" ALLOWED AT 36" A.F.F. AT TANK -TYPE TOILET SANITARY NAPKIN VENDOR DISPENSER (TA-12) X a 0 SURFACE MOUNTED WASTE RECEPTACLE UNIT (TA-11) TYPICAL MOUNTING HEIGHT SCALE: 3/4" = V-0" COMPRESSED CARPET 1/4" MAX BELOW THRESHOLD FINISH FLOOR EVEN 1/4" 1/2 ADA-CHANGE IN LEVEL SCALE: 3/4" = 1'-0" DESIGNED BY: C. CHEANG DRAWN BY: A. DOMINGO CHECKED BY: D. HOGAN 0 12/10/2024 J.C. D.H. C.C. ISSUED FORBID APPROVED BY: No. DATE DSN CHK APP REVISION C. CHEANG 2 1 C'5 LL z Q M � � 0 co 12" MAX- - 0 ti TOILET l DISPENSER (TA-1) F.E.C. FIRE EXTINGUISHER (CABINET) U CO O H LL N Q 1/2" MAX AT 1: 2 1/4" SLOPE 9849 REGISTERED TARCHIT HANTAN STATE OF WASHINGT 39" - 41 " NK OTAINLESS L GRAB BAR HAND DRYER (TA-7) TOILET SEAT COVER DISPENSER (TA-5) o H LL Q 0 C� o ADA -SINGLE ACCOMMODATION TOILETS z O co NOTE: IF A MINIMUM 9 INCHES HEIGHT TO TOE CLEARANCE IS PROVIDED, A MAXIMUM OF 6 INCHES OF THE 48 INCHES OF CLEAR FLOOR SPACE REQUIRED AT THE FIXTURE MAY EXTEND INTO THE TOE SPACE. PLAN VIEW 17" KA I N LAVATORY CLEARANCE SCALE: 1/2" = 1'-0" BT120-APD223 SCALE: 3/4" = V-0" TmRIDE BRT General Engineering Consultant SUBMITTED BY: DATE: REVIEWED BY: R. PARGAS 12/10/2024 J. ALTCHECH LEI z_ J W z W U O H AX. 6" X 16 GA. STL. PLATE LOCATIONS: 2. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY FASTEN TO (2) GRAB BARS LOCATED ON EACH SIDE, OR ONE SIDE AND BACK THE APPLICATION OF A 250-POUND POINT LOAD SHALL STUDS, MIN. OF THE ACCESSIBLE TOILETS STALL OR COMPARTMENTS, SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR BE SECURELY ATTACHED 33 INCHES ABOVE AND PARALLEL TO MATERIAL OF A GRAB BAR OR SEAT, AND IT'S THE FLOOR EXCEPT THAT WHERE A TANK -TYPE TOILET IS USED MOUNTING BRACKET OR OTHER SUPPORT IS (3) STAINLESS WHICH OBSTRUCTS PLACEMENT AT 33 INCHES, THE GRAB BAR CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT STEEL MAY BE AS HIGH AS 36 INCHES. GRAB BAR SHALL BE AT LEAST AND TORSIONAL SHEAR STRESSES SHALL NOT EXCEED R.H.M.S. W/PIPE 42 INCHES FRONT OF WATER CLOSET STOOL GRAB BAR AT THE THE ALLOWABLE SHEAR STRESS. SPACER BACK SHALL NOT BE LESS THAN 36" LONG, +34„ 3. SHEAR FORCE INDUCED IN FASTENER OR _ DIAMETER OR WIDTH: MOUNTING DEVICE FROM THE APPLICATION OF A A.F.F. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES' OF 250-POUND POINT, LOAD SHALL BE LESS THAN THE GRAB BAR SHALL BE 1 1/4" to 1 1/2" OR SHALL PROVIDE AN ALLOWABLE LATERAL LOAD OR EITHER THE FASTENER 1 1/2" EQUIVALENT GRIPPING SURFACE. IF GRAB BARS ARE MOUNTED OR MOUNTING DEVICE OR THE SUPPORTING ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND STRUCTURE, WHICHEVER IS THE SMALLER ALLOWABLE TILE (WHERE GRAB BARS SHALL BE 1 1/2" LOAD. OCCURS) STRUCTURAL STRENGTH: 4. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT (1) LAYER OF THE STRUCTURAL STRENGTH OF GRAB BARS, TUB AND TENSION FORCE OF A 250-POUND POINT LOAD, PLUS W.R. 5/8" GYP. SHOWERS SEATS, FASTENERS AND MOUNTING DEVICES SHALL THE MAXIMUM MOMENT FROM THE APPLICATION OF A BD. AS OCCURS MEET THE FOLLOWING SPECIFICATIONS: 250-POUND POINT LOAD SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN THE 1. BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE FASTENER AND THE SUPPORTING STRUCTURE. MAXIMUM BENDING MOMENT FROM THE APPLICATION OF 250-POUNDS POINT LOAD SHALL BE LESS THAN ALLOWABLE 5. GRAB BARS SHALL NOT ROTATE WITHIN THEIR STRESS FOR MATERIAL OF GRAB BAR SEAT. FITTINGS. GRAB BAR MOUNTING DETAIL SCALE: 1" = 1'-0" SCALE: Q w AS NOTED Q FILENAME: cn w U) J S 1-BT120-A-v2020 z J U_ SOUNDTRANSIT CONTRACT No.: RTA/CN 0205-24 DATE: SUBMITTAL DATE: 12/10/2024 12/10/2024 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 ARCHITECTURE DETAILS CORE FACILITY R-4332417 DEVELOPMENT ENGINEERING + msippo 11 /25/2025 DRAWING NO.: BT120-AID911 FACILITY ID: BT120 SHEET No: REV: 495 0