Loading...
HomeMy WebLinkAboutR-4332423N co co O W 0 N 0 N ii 0 N H m w CAI z ry I 0 a I D 00 of 0 co 00 LO a o o I N Q N_ LO U) ,�t D 0 0 rn cy) m 2.5 2.6 2.7 2.8 2.9 2" DOMESTIC WATER SERVICE - REFER TO CIVIL FOR CONTINUATION I I I I I 4" SANITARY SEWER - REFER TO CIVIL FOR CONTINUATION 4" SANITARY SEWER - REFER TO CIVIL FOR CONTINUATION CORE FACILITY ENLARGED PLUMBING - BELOW FINISHED FLOOR SCALE: 1/4" = V-0" BT120-MPP121 2.5 2.6 2.7 2.8 2.9 I I I I I r/BT1210-13FP-02� 0-BFP-01 OPERAT R OPERATOR RESTRO M RESTRO M BT120L1?07 BT120L1206 18 BT120-PRV-01 BT120-EWH-06 HB-3 �I I ' V` HB-1 BCO 20 OPERATOR RESTRO M BT120L1205 HB-1 BCO 20 2" DCW" WC-1 22 0 FD-1 UR-1 BT120-EWH-02 L-1 21 1 HB-1 OPERATOR RESTROOM BT120L1204 1" NPW MS-1 1 g 3/4" DCW SEC BT120-EWH-03 STORAGE LACTATION ROOM BT120L1202 BT120L1201 FCO - I . . . . . . . . . . . . . . . . . . . . . . . i I a KEY NOTES: C1/2" TP FROM ABOVE - DETAIL 4/BT120-MPD001. 02 1" DCW FROM ABOVE. 3 1" NPW FROM ABOVE. C4, 2" DCW UP THROUGH FLOOR. 5 3" WASTE FROM LAVATORIES. O3" WASTE FROM SINK. 70 3" WASTE FROM MOP SINK. 8 4" WASTE FROM URINALS. (�)� 4" SANITARY SEWER FROM WATER CLOSETS. (10\1 4" WASTE FROM FLOOR DRAIN. (11212" WASTE FROM HUB DRAIN. SEE DETAIL 3/BT120-MPS001. (E2 4" WASTE FROM HUB DRAIN. (13 4" UP TO CLEANOUT - DETAIL 2/BT120-MPD001. T41, DROP 4" SANITARY SEWER DOWN TO LOWER ELEVATION. 15 2" VENT UP THROUGH FLOOR. 40 MAINTAIN 24" VERTICAL LIMIT AT FLOOR DRAINS. 17 3" HUB DRAIN (3" X 2" REDUCER). (E8,4" HUB DRAIN (8" X 4" REDUCER). ROUTE DRAIN FROM BACKFLOW PREVENTER TO HUB DRAIN. REFER TO DETAIL 1/BT120-MPD002 19 3" VENT THROUGH ROOF. 20 4" DOUBLE TWO-WAY CLEANOUT - DETAIL 2/BT120-MPD001. 21 PROVIDE TAILPIECE TYPE TRAP PRIMER - DETAIL 4/BT120-MPD001. ROUTE 3/4" CONDENSATE LINE FROM ACU UNIT IN THIS ROOM TO SINK TAILPIECE. 22 SEE DOMESTIC WATER DIAGRAM 1/BT120-MPS001. 23 SEE SANITARY SEWER RISER DIAGRAM 1/BT120-MPS002. 24 3" UP TO CLEANOUT - DETAIL 1/BT120-MPD001. 25 2" WASTE FROM SINK. 26 1" DCW FROM BELOW FLOOR. 27 1" DCW UP THROUGH FLOOR. 37 2" VENT THROUGH ROOF. C38\> CONNECT 3/4" CONDENSATE LINE FROM ACU IN THIS ROOM TO TAILPIECE AT SINK. CORE FACILITY ENLARGED PLUMBING - AT OR ABOVE 4 2 0 4 8 FINISHED FLOOR 2 DEVELOPMENT ENGINEERING � SCALE IN FEET SCALE: 1/4" - V-0" BT12��221 msippo 11/25/2025 S LVADESIGNED BY DRAWING NO.: Y q w 1/4= 1-0" " ' STRIDE BUS RAPID TRANSIT D �WASfC'1r 7 Q J BT120-MPP222 DRAWN BY: ��w �G,r� U FILENAME: SOUTH RENTON TRANSIT CENTER OST)?IDE D. SILVA�� `vaCS� w J S1-BT120-MP-v2020 BT105 FACILITY ID: CHECKED BY: .ipob 30676 �� BRT General Engineering Consultant :3'� SpUNDTRANSIT CONTRACT No.: MECHANICAL -PLUMBING BT120 M. PHILLIPS t% QST RTA/CN 0205-24 SHEET No: REV: 0 12/10/2024 DOS MP JHS ISSUED FOR BID APPROVED BY: 'rsItONALG� SUBMITTED BY: DATE: REVIEWED BY: DATE: SUBMITTAL DATE: ENLARGED FLOOR PLANS No. DATE I DSN CHK APP I REVISION 1J. SACKINGER I Signed: 12-10-2024 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 CORE FACILITY 501 0