HomeMy WebLinkAboutR-4332428N
C'7
C'7
O
It
W
0
N
0
N
>
a
75
6
N
m
U
w
�I
z
I
ry
I
D
m
0
I
0
co
100
LO
d M
LO
L6 QI
r
LO Cn
O
0
N �
T-
m
INSTALL CAULKING FERRULE AND
RAISED HEAD SCREW PLUG IN AREAS
WHERE SURFACE IS UNFINISHED.
PROVIDE ACCESS HOUSING & COVER
IN FINISHED SURFACES SUCH AS
FLOORS, SIDEWALKS AND DRIVEWAYS
18" x 18" x 6" CONCRETE
PAD OR AS SPECIFIED
FINISHED GRADE
1/4 YARD OF CONCRETE
AROUND FITTING FOR
ANCHOR
SEE PLANS FOR
SIZE MAIN AND
ROUTING OF PIPING
FLOW
CLEANOUT DETAIL
SCALE: NTS
FINISHED FLOOR
o-
..a�o
°oo°.o: voo
:o
SAME SIZE AS MAIN
WITH 4" MAXIMUM
1/8 BEND FITTING AND WYE
FITTING OR COMBINATION 1/8
BEND & WYE FITTING.
PLUG DRAIN PIPE WHEN
CLEANOUT IS LOCATED AT THE
BEGINNING OF A RUN
PROVIDE TAIL
PROVIDE PROTECTIVE J PIECE TYPE TRAP
SLEEVE AT FLOOR PRIMER
PENETRATION
FINISHED FLOOR FLOOR SINK
AND P-TRAP
1/2" TRAP PRIMER LINE ROUTED
BELOW FLOOR TO FLOOR DRAIN
(NO JOINTS BELOW FLOOR)
TRAP PRIMER - TAILPIECE
SCALE: NTS
0 12/10/2024 DOS MP JHS ISSUED FOR BID
No. DATE DSN CHK APP REVISION
BT120-MPP222
BT120-MPP222
DESIGNED BY:
D. SILVA
DRAWN BY:
D. SILVA
CHECKED BY:
M. PHILLIPS
APPROVED BY:
J. SACKINGER
ACCESS HOUSING & COVER
SET FLUSH WITH FINISHED
SURFACE. INSTALL IN FLOOR,
SIDEWALKS AND DRIVES
FINISHED GRADE
1/4 YARD OF
CONCRETE AROUND
FITTING FOR ANCHOR
FLOW
° o
°oe8,
DOUBLE TWO-WAY CLEANOUT DETAIL
SCALE: NTS
IF BRANCH IS GREATER THAN 20' LONG, PROVIDE
ANOTHER WATER HAMMER ARRESTER IN MIDDLE,
EACH SIZED FOR HALF THE FIXTURE """T`'
HOT OR COLD
WATER SUPPLY
INSTALL PER PDI
PDI SIZE "A„
STANDARDS AN[
MANUFACTURER
INSTRUCTIONS
SINGLE FIXTURE
PDI PIPE
SIZE SIZE
FIXTURE
UNIT LOAD
A
1/2"
1-11
B
3/4"
12-32
33-60
61-113
114-154
C
1 "
D
1 1/4"
E
1-1/2"
F
2"
155-330
INSTALL CAULKING FERRULE
AND RAISED HEAD SCREW
PLUG IN AREAS WHERE
SURFACE IS UNFINISHED
24" x 18" x 6" CONCRETE
PAD OR AS SPECIFIED
FINISHED FLOOR
0 0
°age°°o oo°soo °°oo
CAST IRON TO GRADE,
SAME SIZE AS MAIN
WITH 4" MAXIMUM
PIPE MAY EXTEND AS WASTE
OR VENT
CLEANOUT TEE WITH SCREWED
COUNTERSUNK PLUG. TAPERED
THREAD WITH TFE JOINT
COMPOUND �I
WHERE CLEANOUT TEE IS
CONCEALED IN A CHASE OR
PARTITION, PROVIDE COVER
AS SPECIFIED
I �
I I
LOCATE CLEANOUT FACE WITHIN
4" OF WALL SURFACE, PROVIDE
EXTENSION AS REQUIRED
I I �
o ° ^
1/8 BEND FITTING AND WYE
FITTING OR COMBINATION
1/8 BEND & WYE FITTING
COLUMN OR
PARTITION
AS SHOWN ON
FLOOR PLAN
I I
I I
I I
�I I
I I
I I
HUB AT FLOOR
I I
FINISHED FLOOR
� I
RISER LENGTH AS REQUIRED
SEE PLANS FOR SIZE / LONG SWEEP ELBOW AT
MAIN AND ROUTING BEGINNING OF RUN
TWO OF PIPING /
CLEANOUT FITTING
FLOW
NOTES:
SEE PLANS FOR SIZE MAIN
AND ROUTING OF PIPING 1. PROVIDE WCO ON SANITARY WASTE BRANCHES NOT SERVED WITH
FLOOR CLEANOUT. MAXIMUM HEIGHT ABOVE FINISHED FLOOR 4'- 0".
BT120-MPP222
FIXTURE UNIT TABULATION
FIXTURE
COLD
HOT
FLUSH VALVE WATER CLOSET
10
--
URINAL
COUNTER SINK
LAVATORY
MOP BASIN
5
--
1.5
1.5
1.5
1.5
2.25
2.25
WATER COOLER
.25
--
SHOWER
3
3
PROVIDE WATER HAMMER ARRESTERS WITH PISTON AND 0-RING CONSTRUCTION, HAVING
PDI #WH-201, ASSE #1010 AND ANSI #A112.26.1M CERTIFICATION. INSTALL IN HORIZONTAL OR
VERTICAL POSITION, BUT NEVER UPSIDE DOWN. INSTALL INLINE WITH WATER FLOW
DIRECTION IF POSSIBLE. SIZE UNITS PER TABLES ABOVE.
WATER HAMMER ARRESTER DETAIL
SCALE: NTS
p�! I pacobs
A ®3067�
Signed: 12-10-2024
SUBMITTED BY:
R. PARGAS
BT120-MPP222
Tm)?IDE
BRT General Engineering Consultant
DATE: REVIEWED BY:
12/10/2024 J. ALTCHECH
WALL CLEANOUT DETAIL
SCALE: NTS
C.P. 3/8" HOT WATER
SUPPLY TO FIXTURE
IN -LINE FLOW
CONTROL VALVE
COMPRESSION
FITTING
WALL MOUNTED
TANKLESS
ELECTRIC WATER
HEATER
ELECTRIC
CONDUIT
ELECTRICAL
DISCONNECTING
MEANS - REFER TO
ELECTRICAL PLANS
FINISHED FLOOR
BT120-MPP222
WALL MOUNTED
LAVATORY OR
COUNTERTOP SINK
C.P. 3/8" COLD WATER
SUPPLY TO FIXTURE
1/2" COLD WATER
SUPPLY
LOOSE -KEY DUAL
OUTLET ANGLE VALVE
C.P. 3/8" COLD WATER
SUPPLY TO WATER
HEATER
COMPRESSION
FITTING
TANKLESS ELECTRIC WATER HEATER PIPING
SCALE: NTS
SCALE:
Q
w
NTS
Q
FILENAME:
w
S1-BT120-MP-v2020
Z
J
J
LL
SOUNDTRANSIT
0
RCN T
RTA/02 05-24
DATE:
SUBMITTAL DATE:
12/10/2024
12/10/2024
DEVELOPMENT ENGINEERING BT120-MPP222
%
msippo 11 /25/2025 R-4332428
STRIDE BUS RAPID TRANSIT DRAWING NO.:
SOUTH RENTON TRANSIT CENTER BT120-MPD001
BT105 FACILITY ID:
MECHANICAL -PLUMBING BT120
SHEET No: REV:
DETAILS
CORE FACILITY 506 0