HomeMy WebLinkAboutR-4332430N co co O 0 LU 0 N 0 N 75 6 N H m U w c� �I z Q ry I- I 0 d ry I m 0 I 0 co co LO 2o I o� M U) '�t -) 0 0 m cy) m INLETS AND OUTLETS CALLOUT FREE FLOW AREA RECTANGULAR DUCT SIZE AIRFLOW TYPE T1 DIAMETER NECK SIZE DIFFUSER TYPE, SEE 10" OA- SCHEDULE FOR MODULE SIZE �10" SD-1 (500 OA) AIRFLOW IN UNITS OF CUBIC FEET PER MINUTE, CFM, TO BE BALANCED TO FREE FLOW AREA RECTANGULAR DUCT SIZE AIRFLOW TYPE DIAMETER NECK SIZE GRILLE TYPE, SEE SCHEDULE FOR MODULE SIZE 12"x12" EA 16"x8" EG-1 17� (500 EA) AIRFLOW IN UNITS OF CUBIC FEET PER MINUTE, CFM, TO BE BALANCED TO fir► (200) PULLED AIRFLOW, CFM (INCLUDING INFILTRATION) ► (200) PUSHED AIRFLOW, CFM AIRFLOW TYPES: SA - SUPPLY AIR RA - RETURN AIR OA - OUTSIDE AIR EA - EXHAUST AIR 0 12/10/2024 DW MP JHS ISSUED FOR BID No. DATE DSN CHK APP REVISION AHRI EER HSPF MOCP SCCR ABBREVIATIONS AIR-CONDITION, HEATING, AND REFRIGERATION INSTITUTION ENERGY EFFICIENCY RATIO HEATING SEASONAL PERFORMANCE FACTOR MAXIMUN OVER CURRENT PROTECTION SHORT CIRCUIT CURRENT RATING SYMBOLS AND LEGEND WALL REGISTER OR GRILLE (SUPPLY) CEILING DIFFUSER OR REGISTER (SUPPLY) CEILING REGISTER OR GRILLE (RETURN AND EXHAUST) WALL REGISTER OR GRILLE (RETURN AND EXHAUST) TURNING VANES 45 DEGREES ENTRY CONICAL TEE FD FIRE DAMPER MANUAL OPPOSED -BLADE DAMPER MANUAL BUTTERFLY DAMPER MOTORIZED DAMPER M FLEXIBLE CONNECTION FLEXIBLE DUCTWORK 2021 WASHINGTON STATE ENERGY CODE (WSEC) NOTES COMMERCIAL BUILDING, NEW CONSTRUCTION 2018 WSEC. FOR COMPLIANCE WITH THE WSEC FOR OTHER DISCIPLINES SUCH AS ARCHITECTURAL, ELECTRICAL AND PLUMBING SEE THOSE SHEETS. FOR WSEC COMPLIANCE FOR MECHANICAL - HVAC THE PROJECT MUST MEET THE FOLLOWING: C403 MECHANICAL SYSTEMS AS NOTED BELOW. C403.1.1 HVAC TOTAL SYSTEM PERFORMANCE RATIO (TSPR) THIS PROJECT HAS BUILDINGS IS LESS THAN 5000 SF THEREFORE CLAIMS EXCEPTION 1. THIS PROJECT COMPLIES WITH C403.2.2 VENTILATION AND EXHAUST AND CHAPTER 4 IMC. ASHRAE 62.1 SCHEDULE IS SHOWN IN THIS SET. THIS PROJECT SELECTED EQUIPMENT TO MEET THE MINIMUM EFFICIENCY REQUIREMENTS OF TABLES C403.3.2 (1 THROUGH 12). C403.3.2 (1) AIR COOLED SPLIT SYSTEM AIR CONDITIONER MINIMUM 13.0 SEER: ELECTRICAL ROOM. C403.3.2 (2) AIR COOLED SPLIT SYSTEM HEAT PUMP MIN. 14.0 SEER, 8.2 HSPF: SECURITY, CORE FAC. C403.3.2 (3) SINGLE PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS: STORAGE, TELECOM. THIS PROJECT HAS AN AIR-TO-AIR ENERGY RECOVERY VENTILATION UNIT, COMPLIANT WITH C403.3.5. THIS PROJECT DOES NOT HAVE A REQUIREMENT FOR DIRECT DIGITAL CONTROLS PER C403.4.11. ALL CONTROLS ARE LOCAL WIRED THERMOSTATS. THIS PROJECT TAKES THE ECONOMIZERS EXCEPTION TABLE C403.5 FOR UNITS OF CLIMATE ZONE 4C EFFICIENCY IMPROVEMENT OF 64%. ON SPLIT SYSTEM SERVING THE ELECTRICAL SUPPLY DUCT (SECTION) ROOM. C403.6 DOES NOT APPLY. VAV SYSTEMS SERVING MULTIPLE ZONES ARE NOT ON THIS PROJECT. INTAKE, RETURN, OR EXHAUST DUCT SECTION BELLMOUTH OT ROOM TEMPERTURE SENSOR OP ROOM PRESSURE SENSOR ** REFER TO GEN-GZN006 & GEN-GZN007 FOR ADDITIONAL SYMBOLS AND LEGEND. CODES APPLICABLE TO HVAC WASHINGTON STATE MECHANICAL CODE 2021 (IMC 2021 AMMENDED) AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS (ASHRAE): • ASHRAE 62.1, VENTILATION AND ACCEPTABLE INDOOR AIR QUALITY • ASHRAE 55, THERMAL ENVIRONMENTAL CONDITIONS FOR HUMAN OCCUPANCY WASHINGTON STATE COMMERICAL ENERGY CODE 2021 (IECC 2021 AMMENDED) SMACNA HVAC DUCT CONSTRUCTION STANDARDS DESIGNED BY: D. WONG DRAWN BY: L. GOUDEAU CHECKED BY: M. PHILLIPS APPROVED BY: J. SACKINGER �2 t 30676 ' ISTEgFO- Fv ESS'ON Signed: 12-10-2024 C403.7 THIS PROJECT COMPLIES WITH VENTILATION AND EXHAUST SYSTEMS. IN PARTICULAR THIS PROJECT USES AN OCCUPANCY SENSOR AT THE SECURITY BUILDING AND An ENERGY RECOVERY UNIT FOR VENTILATION NEEDS AT THE CORE FACILITIES BUILDING. SEE ASHRAE 62.1 VENTILATION COMPLIANCE SCHEDULE. C403.7.4.2 THE PROJECT OCCUPANCY SENSOR AT SECURITY BUILDING WILL AUTOMATICALLY TURN OFF THE SUPPLY AIR FAN WITHIN 30 MINUTES OF THE OCCUPANTS LEAVING THE BUILDING. C403.7.8 THE OCCUPANCY SENSOR FAN AT SECURITY BUILDING WILL COMPLY WITH THE REQUIREMENT OF SHUTOFF DAMPERS AND BE CLASS 1 LEAKAGE OF LESS THAN 4 CFM/SF AT 1.0 INCH WATER GAUGE WHEN TESTED IN ACCORDANCE WITH AMCA 500D. C403.8 THIS PROJECT DOES NOT HAVE ANY FAN SYSTEM MOTOR NAMEPLATES EXCEEDING 5 HP. C403.10 CONSTRUCTION OF HVAC SYSTEM ELEMENTS COMPLY WITH THIS SECTION. DUCTS CONVEYING OUTSIDE AIR WILL BE INSULATED TO R-7, PER TABLE C403.10.1.1 OUTDOOR AIR DUCTS INSIDE A CONDITIONED SPACE CRITERIA <2800 CFM WILL BE USED FOR THIS PROJECT. PER C403.10.1.2 ALL OTHER DUCTS SUPPLY, RETURN, EXHAUST DUCTS WILL BE INSULATED USING A DUCT LOCATION AS INSIDE UNCONDITIONED SPACES, R-6. C403.10.2 THIS PROJECT USES LOW PRESSURE DUCT SYSTEMS OPERATING AT < 2 INCHES WATER GAUGE, CONSTRUCTED PER IMC AND THAT WILL BE LONGITUDINAL AND TRANSVERSE JOINTS SEAMS ANS CONNECTIONS SEALED WITH WELDS, GASKETS, MASTICS OR TAPES IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND THE SPECIFICATIONS. C403.10.3 PIPING INSULATION WILL BE APPLIED PER TABLE C403.10.3 PER FLUID OPERATING TEMPERATURES, INSULATION CONDUCTIVITY AND NOMINAL PIPE OR TUBE SIZE. C404 NOTES SEE PLUMBING, C405 NOTES SEE ELECTRICAL. C406.1 ADDITIONAL ENERGY EFFICIENCY CREDIT REQUIREMENTS, THIS PROJECT COMPLIES WITH EXCEPTION 1 BY BEING LOW ENERGY SPACES WITH SUFFICIENT PACKAGES FROM TABLE TO ACHIEVE A MINIMUM OF THREE CREDITS. C407 TOTAL BUILDING PERFORMANCE METHOD IS NOT USED ON THIS PROJECT. C408.1 SYSTEM COMMISSIONING, IS NOT REQUIRED PER EXCEPTIONS 1 HVAC AND 2 PLUMBING. C408.2 EXCEPTION 1. TOTAL MECHANICAL SYSTEMS IS LESS THAN 240 MBH COOLING AND LESS THAN 300 MBH HEATING. C408.3 EXCEPTION 2. LARGEST SERVICE WATER HEATING SYSTEM CAPACITY IS LESS THAN 200 MBH. C409 ENERGY METERING AND ENERGY MANAGEMENT. SEE ELECTRICAL, THE HVAC CONTRACTOR WILL NOT BE RESPONSIBLE FOR ANY ENERGY METERING OR ENERGY MANAGEMENT. pacobs SUBMITTED BY: R. PARGAS Tm)?IDE BRT General Engineering Consultant DATE: REVIEWED BY: 12/10/2024 J. ALTCHECH WASHINGTON STATE ENERGY CODE DESIGN CONDITIONS SCALE: Q w NTS Q FILENAME: cnC/) w J S1-BT120-MH-v2020 z J SOUNDTRANSIT CONTRACT No.: RTA/CN 0205-24 DATE: SUBMITTAL DATE: 12/10/2024 12/10/2024 THIS DESIGN WAS ENGINEERED WITH WSEC CHAPTER 3 CLIMATE ZONE 4 C (MARINE), KING COUNTY, WASHINGTON INTERIOR DESIGN CONDITIONS PER WSEC SECTION C302.1 MAXIMUM OF 72 F FOR HEATING, MINIMUM OF 75 F FOR COOLING EXTERIOR DESIGN CONDITIONS, OUTDOOR DESIGN TEMPERATURES THIS DESIGN WAS ENGINEERED WITH WSEC SECTION 302.2, APPENDIX C TABLE C-1 CONDITIONS. OUTDOOR TEMPERATURES: (SEA TAC AIRPORT) COOLING SUMMER: 83 OF DRY BULB 65 OF WET BULD HEATING WINTER 24 OF DRY BULB NA R-4332430 FDEVELOPIMENT ENGINEERING o 11 /25/2025 STRIDE BUS RAPID TRANSIT DRAWING NO.: SOUTH RENTON TRANSIT CENTER BT120-MHN001 BT105 MECHANICAL-HVAC LEGEND, ABBREVIATIONS AND ENERGY CODES CORE FACILITY FACILITY ID: BT105 SHEET No: REV: 508 0