Loading...
HomeMy WebLinkAboutR-4332431N cy) cy) O 0 LU 0 N 0 N 75 0 N H m U w c� I z Q ry 0I a ry I D m 0 I 0 co 00 LO d 0 rn I �Q o� M U) 0 0 m CONSTRUCTION NOTES: O IN ADDITION TO THE OBD AT THE GRILLE. INSTALL A MANUAL BALANCING DAMPER ON EACH SUPPLY BRANCH TO LACATION, TO SECURITY STORAGE AND SECURITY OFFICE (2 INSTALL A MANUAL BALANCING DAMPER ON EXHAUST BRANCH FROM LACATION. THIS IS IN ADDITION TO THE OBD AT THE GRILLE. 0 1 12/10/2024 I DW I MP I JHS I ISSUED FOR BID No. I DATE I DSN I CHK I APP I REVISION GENERAL NOTES: 1. DRAWINGS ARE A GENERAL GRAPHIC SCHEMATIC REPRESENTATION OF THE WORK. FABRICATE AND INSTALL BASED ON ACTUAL FIELD MEASUREMENTS. COORDINATE WITH OTHER TRADES. PROVIDE A COMPLETE SET OF SHOP DRAWINGS REFLECTING ACTUAL DIMENSIONS, ACCESS REQUIREMENTS, AND DETAILS BASED ON THE ACTUAL EQUIPMENT PROCURED. MAINTAIN AN UP TO DATE SET OF AS-BUILTS ON THE JOB SITE. 2. REFER TO SPECIFICATIONS FOR MATERIALS, PRODUCTS AND DIRECTIONS FOR CONSTRUCTION. 3. COORDINATE LOCATION OF ALL PENETRATIONS WITH THE BUILDING STRUCTURE. 4. REFER TO ARCHITECTURE FOR PENETRATION DETAILS THROUGH BUILDING ENVELOPE. 5. PERFORM WORK IN ACCORDANCE WITH THE LATEST EDITIONS, REVISIONS, AMENDMENTS, OR SUPPLEMENTS OF APPLICABLE STATUTES, ORDINANCES, CODES, OR REGULATIONS OF FEDERAL, STATE, AND LOCAL AUTHORITIES HAVING JURISDICTION. 6. WHERE APPROVAL CODES HAVE BEEN ESTABLISHED BY OSHA, UNDERWRITERS LABORATORY, AMERICAN COEDS, ANSI, ASME, ASHRAE, ASTM, ARI, NEC, NFPA, SMACNA, OR THE STATE FIRE INSURANCE REGULATORY BODY, FOLLOW THESE STANDARDS WHETHER OR NOT INDICATED ON THE DRAWINGS. 7. COORDINATE WORK WITH ARCHITECTURAL FEATURES AND COORDINATE WORK SUCH THAT THE INTERFERENCES BETWEEN PIPING, DUCTWORK, EQUIPMENT, PLUMBING WORK, ELECTRICAL WORK, AND BUILDING STRUCTURE WILL BE AVOIDED. 8. PROVIDE ALL WIRING AND ELECTRICAL CONTROLS IN ACCORDANCE WITH NFPA 70 (NEC). 9. DO NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES. 10. PAINT ANY ABOVE CEILING ITEMS, WHICH CAN BE SEEN THROUGH AIR SLOTS OR GRILLES, FLAT BLACK. 11. PROVIDE CEILING ACCESS FOR ALL DAMPERS. 12. HANDLE, STORE, AND INSTALL EQUIPMENT ACCORDING TO MANUFACTURER'S INSTRUCTIONS. 13. DUCT AND DUCT HANGERS SHALL ADHERE TO SMACNA HVAC DUCT STANDARDS. DUCT AND PIPE HANGERS AND SUPPORTS IN UNCONDITIONED SPACE OR EXTERIOR TO BUILDING MUST BE GALVANIZED STEEL. 14. PROVIDE DUCT ACCESS PANELS FOR ALL DAMPER ACTUATORS AND MOTORS LOCATED INSIDE DUCT OR FAN HOUSINGS. 15. REFER TO STRUCTURAL DRAWINGS FOR FRAMING REQUIRED AROUND PIPES AND DUCTS PENETRATING ROOFS, WALLS, AND FLOOR. 16. PROVIDE ACCESS AND CLEARANCE FOR MAINTENANCE FOR MECHANICAL EQUIPMENT AND COMPONENTS AS RECOMMENDED BY EQUIPMENT MANUFACTURER AND APPLICABLE CODES 17. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATIONS OF DIFFUSERS, REGISTERS, GRILLES, AND ACCESS PANELS. 18. ALL DUCT DIMENSIONS AS SHOWN ON MECHANICAL DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 19. COORDINATE EQUIPMENT PAD LOCATIONS AND SIZES WITH ACTUAL EQUIPMENT PROCURED. 20. COORDINATE WITH ELECTRICAL AND CONTROLS CONTRACTOR FOR POWER REQUIREMENTS TO ALL MECHANICAL EQUIPMENT PRIOR TO ORDERING ANY EQUIPMENT. 21. SQUARE ELBOWS IN DUCTWORK MUST HAVE TURNING VANES. 22. ALL DUCT AND PIPE TRANSITIONS, TURNS, AND OFFSETS ARE NOT SHOWN. PROVIDE THESE ITEMS AS REQUIRED FOR A COMPLETE SYSTEM. 23. OVERHEAD UTILITIES AND EQUIPMENT WEIGHING 31 LBS OR MORE MUST BE MOUNTED SO THAT THEY RESIST 0.5 TIMES THE COMPONENT WEIGHT IN ANY HORIZONTAL DIRECTION AND 1.5 TIMES COMPONENT WEIGHT IN THE DOWNWARD DIRECTION. THIS MUST BE ACCOMPLISHED BY EITHER RIGID OR FLEXIBLE SYSTEMS. REFER TO SPEC SECTION ON SEISMIC BRACING FOR REQUIREMENTS. 24. DUCTS SHALL BE INSULATED WITH DUCT WRAP PER SPECIFICATIONS AND THE ENERGY CODE. DESIGNED BY: D. WONG DRAWN BY: L. GOUDEAU CHECKED BY: M. PHILLIPS APPROVED BY: J. SACKINGER /mow o� wA ��',�t _{ 30676 �0�' ��GISTEgFO- Fv ESS1oN �ti Signed: 12-10-2024 GENERAL NOTES CONT'D: 25. HVAC TEMPERATURE SET POINTS, DEAD BANDS, AND SCHEDULES SHALL BE SET PER 2021 WASHINGTON STATE ENERGY CODE (IECC 2021 AMMENDED). 26. CONTRACTORS ARE FREE TO USE ANY PRODUCT WHICH MEETS THE GOVERNMENT'S MINIMUM REQUIREMENTS AND NOT IN CONFLICT WITH OTHER CONTRACT PROVISIONS. UNLESS INDICATED OTHERWISE ON THE PLANS OR SPECIFICATIONS (E.G. SOLE -SOURCE), ALL LISTED MANUFACTURERS ARE THE BASIS OF DESIGN. FOR THESE BASIS OF DESIGN PRODUCTS, OTHER MANUFACTURERS MAY BE SUBSTITUTED AS LONG AS THE STANDARD OF QUALITY AND CHARACTERISTICS OF THE SUBSTITUTED MANUFACTURER MEET OR EXCEED THE STANDARD OF QUALITY AND CHARACTERISTICS OF THE BASIS OF DESIGN. 27. REFER TO GEN-GZN006 AND GEN-GZN007 FOR ADDITIONAL SYMBOLS AND LEGENDS. 28. FOR MINIMUM OUTSIDE AIR AND EXHAUST REQUIREMENTS SEE VENTILATION SCHEDULE (BASED ON RATES FROM 2021 WASHINGTON STATE MECHANICAL CODE). .;acobs SUBMITTED BY: R. PARGAS 4STmRIDE BRT General Engineering Consultant DATE: REVIEWED BY: 12/10/2024 J. ALTCHECH KEY NOTES: O ACCESS HATCH ALLOWS FOR ADJUSTMENT OF EG-2 AND FOR GENERAL INSPECTION OF OPEN AREA ABOVE COMFORT STATIONS. OPEN AREA OVER COMFORT STATIONS IS ALSO OPEN TO JANITORS AND LACATION ROOMS. O FIELD ROUTE INTO ARCHITECTURAL HORIZONTAL DUCT CHASE OR SOFFIT TO CROSSOVER TO SECURITY OFFICE. O FIELD ROUTE THE SUPPLY AIR DOWN AND OVER THE DOOR. Q w _j fir= cn� W J J z SOUNDTRANSIT DATE: 12/10/2024 SCALE: NTS FILENAME: S1-BT120-MH-v2020 CONTRACT No.: RTA/CN 0205-24 SUBMITTAL DATE: 12/10/2024 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 MECHANICAL-HVAC CONSTRUCTION, GENERAL AND KEY NOTES CORE FACILITY R-4332431 DEVELOPMENT ENGINEERING msippo 11 /25/2025 Ul DRAWING NO.: BT120-M H N 002 FACILITY ID: BT105 SHEET No: REV: 509 0