HomeMy WebLinkAboutR-4332438N C'7 C'7 0 W 0 N O N 75 N m U LU c� I z ry I c) d ry I D m 0 I 0 co 00 LO Q co o r) co QI L� U) 0 0 o cy) N m 0 12/10/2024 DW MP No. DATE DSN CHK BACNET MS/TP BACNET IP DATA CONNECTION TO BUILDING IT NETWORK - - KN TO DIV 25 SPEC I ATS BT120-ATS-01 LOCATED IN TELECOM ROOM BT120L120E BT105-BMS- 120VAC BY DIV. 26 CAT-6 F - -I F I -1 F I � ACU ACU ACU ACU ACU ACU ACU ACU ACU ACU ERU ACU BT105-ACU-01 BT105-ACU-02 BT105-ACU-03 BT105-ACU-04 BT105-ACU-05 BT105-ACU-16 BT105-ACU-26 BT105-ACU-36 BT105-ACU-46 BT105-ACU-56 BT105-ERU-01 BT105-ACU-07 HVAC SYSTEM MONITORING (NOTE 9) I F --71 i LCP LCP LCP I I BT105-LCP-01 BT105-LCP-02 BT105-LCP-03 I I LIGHTING CONTROLLERS (NOTE 11) J I MODBUS RTU' - __1 F_ ) ) GEN PQM BT105-GEN-01 BT105-SWGR-01 ELECTRICAL EQUIPMENT (NOTE 10) IP CONNECTION TO BUILDING IT - NETWORK. ( BY DIV. 27. EUPS BT105-UPS-01 ELECTRICAL EQUIPMENT, NOTE 10 LEVEL 1 JHS ISSUED FORBID APP REVISION �-1 F� ACU ACU ACU ACU ACU BT105-ACU-16 BT105-ACU-26 BT105-ACU-36 BT105-ACU-46 BT105-ACU-56 SPLIT SYSTEM CONTROLS (NOTE 9) MULTIZONE SPLIT SYSTEM INTERCONNECTS, COORDINATE WIRING REQUIREMENTS WITH MANUFACTURER. CU fff7P-n AIR COOLED CONDENSING UNITS (NOTE 9) CAT-6 IP CONNECTION TO BUILDING IT NETWORK. HMI BY DIV. 27. MULTIZONE SPLIT SYSTEM MASTER CONTROLLER NOTES: 1. ONLY A REPRESENTATIVE SAMPLE OF CONTROLLERS ARE SHOWN. COMPLETE SYSTEM ARCHITECTURE TO BE PROVIDED BY CONTROLS CONTRACTOR. 2. ALL EQUIPMENT BY CONTROLS CONTRACTOR, UNLESS NOTED OTHERWISE. 3. NETWORK CONFIGURATION SHALL CONFORM WITH ALL PERFORMANCE REQUIREMENTS IN SECTION 25 10 00. 4. PROVIDE LOCKABLE ENCLOSURES FOR ALL PSCs, SCs AND NETWORK EQUIPMENT. 5. ALL BMS EQUIPMENT, CONTROLLERS AND NETWORK EQUIPMENT SHALL BE POWERED FROM 120VAC POWER CIRCUITS. COORDINATE POWER REQUIREMENTS AND FINAL LOCATIONS WITH DIVSION 26. 6. CONFIRM ALL BMS PANEL LOCATIONS WITH CLIENT PRIOR TO INSTALLATION. 7. 24VAC POWER TRUNK WIRING AND STEP-DOWN TRANSFORMERS PROVIDED BY CONTROLS CONTRACTOR, AND SHALL BE POWERED FROM 120VAC POWER CIRCUITS. 8. INTEGRATE TO 3RD PARTY SYSTEM CONTROLLER VIA BACNET OR MODBUS COMMUNICATION, COORDINATE REQUIREMENTS WITH EQUIPMENT VENDOR. 9. CONTROLLER PROVIDED BY MANUFACTURER, CONTROLS CONTRACTOR SHALL INTERGRATE TO THIS EQUIPMENT. 10. CONTROLS CONTRACTOR SHALL INTEGRATE TO ELECTRICAL EQUIPMENT PROVIDED BY DIVISION 26. REFER TO ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR QUANTITIES AND LOCATIONS. 11. CONTROLS CONTRACTOR SHALL INTEGRATE WITH LIGHTING CONTROL SYSTEM. REFER TO ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR QUANTITIES AND LOCATIONS OF LIGHTING CONTROL PANELS. DESIGNED BY: M. LUCERO DRAWN BY: R. PREWITT CHECKED BY: J.BEAUDRY APPROVED BY: J. SACKINGER 30676 e ' ISTEgFO- Fv ESS'ON Signed: 12-10-2024 SUBMITTED BY: R. PARGAS lcob,115. 4STmRIDE BRT General Engineering Consultant DATE: REVIEWED BY: 12/10/2024 J. ALTCHECH Q w cn� W J J z " SOUNDTRANSIT DATE: 12/10/2024 SCALE: NTS FILENAME: S1-BT120-MH-v2020 CONTRACT No.: RTA/CN 0205-24 SUBMITTAL DATE: 12/10/2024 LEVEL 1 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 MECHANICAL-HVAC CONTROLS NETWORK DIAGRAM CORE FACILITY R-4332438 DEVELOPMENT ENGINEERING msippo 11 /25/2025 Ul DRAWING NO.: BT120-MHS006 FACILITY ID: BT105 SHEET No: REV: 516 0