HomeMy WebLinkAboutR-4332441N co co O A W 0 N 0 N > 75 0 N m W U w C� �I W z ry I 0 a �I m 0 I 0 co co 2 't a o ~ I co W O 0 m ATTACH TO STRUCTURE PER SMACNA RECOMMENDAT'^"'c STAINLESS STE SHEET METAL 1/2" MINIMUM BAND CLAMP LENGTH EQUA DIAMETER OF NOTES: 1. DO NOT USE POWDER POWERED FASTENING SYSTEMS TO ATTACH SUPPORTS TO STRUCTURE. 2. SUPPORT SYSTEM MUST NOT DAMAGE DUCT, INSULATION, OR CAUSE DUCT SHAPE DEFORMATION. 3. HANGER SIZES SHALL BE IN ACCORDANCE WITH SMACNA, LATEST EDITION. 4. THE USE OF PLUMBING STRAP OR NYLON/PLASTIC STRAP FOR DUCT OR EQUIPMENT SUPPORT IS PROHIBITED. RIGID/FLEXIBLE ROUND DUCTWORK DUCTWORK SUPPORT DETAIL SCALE: NTS RECTANGULAR DUCT SQUARE ELBOW TURNI "" "'mac 12" MINIMUM PROVIDE TURNING VANES ON ALL RECTANGULAR SUPPLY DUCTWORK RECTANGULAR DUCT RADIUSED ELBOW UNLESS NOTED OTHERWISE DO NOT INSTALL TURNING VANES IN RETURN OR EXHAUST AIR DUCT. 5W TURNING VANES TO BE DOUBLE WIDTH VANES OR SINGLE WIDTH VANES WITH 3/4" TRAILING EDGE. DUCT OFFSET 5° MAXIMUM DO NOT USE FLEX DUCT FOR OFFSETS. ROUND DUCT TAKE -OFF FROM RECTANGULAR DUCT TAKE OFF TO BE AN EXPANDED CONICAL, BELLMOUTH FLANGED TYPE FITTING. NO BUTT TAP TYPE FITTINGS WILL BE ALLOWED. ATTACH TO STRUCTURE WITH BEAM CLAMPS AS DETAILED ALL -THREAD ROD NUT WITH LOCK WASHER 1-1/2" GALVANIZED STEEL HANGER WITH ALL -THREAD ROD IN TRAPEZE CONFIGURATION RECTANGULAR DUCTWORK BT 120-MHP222 ROUND DUCT RADIUSED ELBOW 5W GORED ELBOWS ARE NOT ALLOWED. ROUND DUCT TAKE -OFF FROM ROUND DUCT AN EXPANDED CONICAL TAP MAY BE SUBSTITUTED FOR ANGLED TAKEOFFS ON LOW PRESSURE SYSTEM. NOTES: 1. THE USE OF PLUMBING STRAP OR NYLON/PLASTIC STRAP FOR DUCT OR EQUIPMENT SUPPORT IS PROHIBITED. 2. MAXIMUM FLEX DUCT LENGTH IS 3'. STANDARD DUCT FITTINGS DETAIL SCALE: NTS 0 12/10/2024 DW MP JHS ISSUED FOR BID No. DATE DSN CHK APP REVISION BT120-MHP222 DESIGNED BY: D. WONG DRAWN BY: L. GOUDEAU CHECKED BY: M. PHILLIPS APPROVED BY: J. SACKINGER RECTANGULAR DUCT TAKE -OFF :XPANDED JAT L=1/4W,4"MIN DUCT SIZE TRANSITION DIMENSION "A" TO BE A MAXIMUM OF 22.50 FOR DIVERGING AND 300 FOR CONVERGING AIR FLOWS. THIS APPLIES FOR BOTH ROUND AND RECTANGULAR DUCTWORK INCLUDING SQUARE TO ROUND TRANSITIONS. SEAL PERIMETER JOINT WATER -TIGHT 18 GA GALVANIZED STEEL DRAINABLE FIXED BLADE LOUVER,SEE LOUVER SCHEDULE - ALUMINUM BIRD SCREEN ACROSS OPENING EXTERIOR WALL - VERIFY CONSTRUCTION MATERIAL AND COORDINATE OPENING REQUIREMENTS LOUVER CONNECTION DETAIL SCALE: NTS FULL-SIZE SHEET METAL PLENUM FABRICATE SHEET METAL PLENUM -TO -DUCT TRANSITION. DUCT SIZE AS INDICATED ON DRAWINGS ROUND OR RECTANGULAR DUCT WORK AS INDICATED ON DRAWINGS. SUPPORT FROM STRUCTURE ABOVE BT 120-M H P222 METAL ROOF— - - STEEL -------------- ------------ BEAM _ --------1/4" DIA TEK THREADED _ SCREWS, MIN 2 SIDE BEA�le PER BRACKET � BRACKET METAL BUILDING BEAM PURLIN CLAMP BEAM CLAMP RETAINING -T*--3/8" DIA 3/8" DIA STRAP THREADEI THREADED ROD, ROD, SEE SEE NOTE 1 NOTE 1 TYPE C - METAL BUILDING PURLIN TYPE D - STEEL BEAM INTERIOR WALL, SEE FLOOR PLAN INDOOR UNIT (ACU) OVERHEAD, SEE SCHEDULE PROVIDE WALL SLEEVES FOR PIPING SA PROVIDE FOR WIRED THERMOSTAT UNLESS SCHEDULED AS REMOTE CONTROL INSTALL ON WALL AT 96" FROM FLOOR TO BOTTOM OF UNIT (UNLESS NOTED OTHERWISE) SEQUENCE OF OPERATION SETPOINT TEMPERATURE: COOLING: CONTINUOUS 780 F HEATING: OCCUPIED 68' F RUN MODE: 1. EVAPORATOR RUN SHALL RUN CONTINUOUSLY. 2. UNITS SHALL CYCLE HEATING OR COOLING SECTION OFF/ON AS REQUIRED TO MAINTAIN ROOM SETPOINT. SPLIT SYSTEM AIR CONDITIONING UNIT SCALE: NTS Y 0 WATmRIDE 7 ",-I *pacobs 4S A 30676 BRT General Engineering Consultant Ino14 �T NAL SUBMITTED BY: DATE: REVIEWED BY: Signed: 12-10-2024 R. PARGAS 12/10/2024 J. ALTCHECH 1 I I I I I I I I I I I I I I I I I i L SCALE: Q w NTS Q FILENAME: WU) w J S1-BT120-MH-v2020 z J LL SOUNDTRANSIT CONTRACT No.: RTA/CN 0205-24 DATE: SUBMITTAL DATE: 12/10/2024 12/10/2024 WOOD RAFTER OR TRUSS CHORD GYP BOARD OR PLYWOOD CEILING i CEILING PLATE WITH THREADED ROD COUPLER (2) 1 /4" x 1 1 /2" WOOD SCREWS 3/8" DIA THREADED ROD, SEE NOTE 1 TYPE E - WOOD NOTES: 1. MAXIMUM ALLOWABLE SUPPORTED LOAD PER HANGER: TYPE A 600 LBS TYPE D 600 LBS TYPE B 250 LBS TYPE E 150 LBS TYPE C 300 LBS SUPPORT ANCHORING DETAIL SCALE: NTS BT 120-M H P221 BT 120-M H P222 INSULATED 3/4" CONDENSATE DRAIN LINE, ROUTE TO DRAIN AS INDICATED ON DRAWINGS EXTERIOR WALL, SEE FLOOR PLAN POWER AND CONTROL WIRING TO INDOOR UNIT INSULATED REFRIGERANT LINES. SECURE TO WALL PER MANUFACTURER'S REQUIREMENTS. PROVIDE SHROUD WHERE INDICATED ON SCHEDULE OUTDOOR UNIT (HPMP), SEE SCHEDULE. PROVIDE MANUFACTURER'S REQUIRED CLEARANCE FOR VENTILATION. Imo\\ % AIRFLOW SEE STRUCTURAL DWG FOR MOUNTING DETAIL. BT120-MHP221 BT120-MHP222 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 MECHANICAL-HVAC DETAILS CORE FACILITY R-4332441 DEVELOPMENT ENGINEERING msippo 11 /25/2025 DRAWING NO.: BT120-M H DO01 FACILITY ID: BT105 SHEET No: REV: 519 0