Loading...
HomeMy WebLinkAboutR-43324426 0 LU 0 N 0 N w 0 N m U) 0 w W z I 0 a I W D m of 0 co 00 LO �o N Q o � N U) N 0 0 LO cy) m ELECTRIC SYMBOLS WIRING DEVICE LEGEND POWER DISTRIBUTION / EQUIPMENT LEGEND WIRING SYSTEM/RACEWAY/CABLE TRAY LEGEND LIGHTING CONTROL DEVICE LEGEND 13 ONE OR TWO NUMERIC DIGIT BRANCH CIRCUIT NUMBER (13 IN THIS FLOOR OR SURFACE MOUNTED 208V PANELBOARD BRANCH CIRCUIT "HOMERUN", TIC MARKS INDICATE NUMBER OF K KEYED SWITCH EXAMPLE) - - - CONDUCTORS (INCLUDING NEUTRAL). #10 INDICATES AWG WIRE 3 THREE WAY. +48" DENOTES THE MOUNTING HEIGHT IN INCHES ABOVE THE FINISHED FLOOR. FLOOR OR SURFACE MOUNTED 480V PANELBOARD SIZE, AND 3/4" INDICATES CONDUIT SIZE. WIRE AND CONDUIT GFCI GFCI TYPE, WIRED FOR GFCI TRIP FOR DESIGNATED RECEPTACLE ONLY � SIZE IS APPLICABLE TO EACH CIRCUIT INDICATED FOR ENTIRE 4 FOUR WAY. (NON-FEED-THRU INSTALLATION) LENGTH OF CIRCUIT. ALL BRANCH CIRCUIT WIRING SHALL 3K THREE WAY KEYED SWITCH. RECESSED 208V PANELBOARD INCLUDE A #12 AWG GROUND IN 3/4" CONDUIT. ARROW HEADS 4K FOUR WAY KEYED SWITCH. PR PROJECTOR RECEPTACLE TO BE LOCATED WITHIN PROJECTOR OR DENOTE A HOMERUN TO PANELBOARD. NUMBER OF CEILING MOUNT RECESSED 480V PANELBOARD ARROWHEADS INDICATE NUMBER OF CIRCUITS IN CONDUIT. D WALL DIMMER. "LP-1,3" INDICATES PANEL AND CIRCUIT NUMBERS. WHEN USED ON DEMOLITION PLANS: DEMOLISH DEVICE AND FACEPLATE, MD MULT-LOCATION DIMMER, NUMERALS AS INDICATED FOR SINGLE R OUTLET BOX TO REMAIN. - - q SWITCH LEG CONNECTED TO SWITCH "A" LOCATION DIMMER. WHEN USE ON NEW WORK PLANS: INSTALL DEVICE IN EXISTING OUTLET 5 GENERAL PURPOSE, DRY TYPE TRANSFORMER. 'T75' IS THE KVA DP DOUBLE POLE. BOX. RATING FOR THE TRANSFORMER. IN THIS EXAMPLE, 'T75' SPD SURGE PROTECTIVE DEVICE TYPE RECEPTACLE REPRESENTS A TRANSFORMER RATED 75KVA. R1 SWITCH LEG CONNECTED TO RELAY #1 IN LIGHTING CONTROL XP EXPLOSION PROOF PANEL INDICATED. TR TAMPER RESISTANT TYPE RECEPTACLE OS OCCUPANCY SENSOR [WITH MANUAL OVERRIDE]. TVM TICKET VENDING MACHINE ATs AUTOMATIC TRANSFER SWITCH. CONDUIT OR CABLE TURNING UP OR TOWARD THE OBSERVER VS VACANCY SENSOR/SWITCH U USB CHARGING CONDUIT OR CABLE TURNING DOWN OR AWAY FROM THE VD VACANCY SENSOR/DIMMER sPD SURGE PROTECTIVE DEVICE OBSERVER WP WEATHER -RESISTANT, WEATHERPROOF WITH HINGED COVER O OCCUPANCY SENSOR/SWITCH CONDUIT OR CABLE CHANGE IN ELEVATION WP-WIN WEATHER -RESISTANT TYPE, WEATHERPROOF WITH WHILE -IN -USE COVER �-%' MOTOR CONNECTION; MOTOR HORSEPOWER AS SHOWN OD OCCUPANCY SENSOR/DIMMER 3 � -- SINGLE CONDUIT CAPPED 03 THREE WAY OCCUPANCY SENSOR C)z DUPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE, RECEPTACLES CONNECTION POINT TO EQUIPMENT SPECIFIED IN OTHER DIVISIONS. ® MULTIPLE CONDUITS, ALL INDIVIDUALLY CAPPED. WHERE OR OVERRIDE SWITCH ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R. RACEWAY, CONDUCTOR, TERMINATION AND CONNECTION IN THIS NUMERIC DESIGNATION INDICATED, DENOTES QUANTITY OF GFCI DUPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE, DIVISION. CAPPED CONDUITS. IN THIS EXAMPLE, THREE CAPPED CONDUITS WP WEATHERPROOF. RECEPTACLES ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R. 100AS 7-1 FUSED SAFETY SWITCH, 100 AMP SWITCH, 80 AMP FUSES M SURFACE MOUNTED MOTOR RATED WITH OVERLOAD ELEMENTS, 80AF CONDUIT WITH BUSHING CONTINOUS CURRENT RATING AND QUANTITY OF POLES AS REQUIRED DUPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE, RECEPTACLES FOR EQUIPMENT SERVED. ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R, MOUNTED 6" ���� ABOVE COUNTERTOP OR BACKSPLASH UNLESS OTHERWISE NOTED. ❑J NON -FUSED SAFETY SWITCH RACEWAY CONTINUATION RECESSED WALL MOUNTED SWITCH. INSTALL ADJACENT DEVICES UNDER COMMON FACEPLATE, FOUR DEVICES MAXIMUM PER FACEPLATE. EVENLY � DUPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE, RECEPTACLES DIVIDE DEVICES INTO SEPARATE GROUPS WHERE ADJCENT DEVICES ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R ON AN COMBINATION MOTOR STARTER DISCONNECT SWITCH CABLE TRAY OR CONDUIT RACK EXCEEDS FOUR. EMERGENCY CIRCUIT. SURFACE WALL MOUNTED SWITCH.INSTALL ADJACENT DEVICES UNDER DUPLEX CONTROL RECEPTACLE. UNLESS INDICATED OTHERWISE LOCAL CONTROLLER COMMON FACEPLATE, FOUR DEVICES MAXIMUM PER FACEPLATE. RECEPTACLES ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R. LUMINAIRE LEGEND EVENLY DIVIDE DEVICES INTO SEPARATE GROUPS WHERE ADJCENT TWO DUPLEX QUAD RECEPTACLES. UNLESS INDICATED OTHERWISE (QUAD) � cTL CONTROL PANEL DEVICES EXCEEDS FOUR. RECEPTACES ARE FLUSH MOUNTED, 20A, 125V, 1PH, 2P, 3W, NEMA 5-20R. NUMERAL =CIRCUIT NUMBER. ONLY WHEN THE OUTLINE AREA OF THE 3� CEILING MOUNTED DUAL -TECHNOLOGY OCCUPANCY SENSOR CIRCUIT IS PROVIDED. OTHERWISE PANEL NUMBER WILL BE INCLUDED SIMPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE, RECEPTACLES RB JUNCTION BOX WITH COVER PLATE &J WITH CIRCUIT NUMBER. CEILING MOUNTED DUAL -TECHNOLOGY CORRIDOR OCCUPANCY ARE FLUSH MOUNTED, 20A, 1 25V, 1 PH, 2P, 3W, NEMA 5-20R. A1E a�--- LOWERCASE ALPHANUMERIC CHARACTER = LIGHTING SWITCH ® SPECIAL PURPOSE RECEPTACLE, UNLESS INDICATED OTHERWISE, WALL MOUNTED JUNCTION BOX WITH COVER PLATE OR CONTROL ZONE 'E' DESIGNATION LIGHTING FIXTURE WITH EMERGENCY SOURCE SENSOR RECEPTACLES ARE FLUSH MOUNTED. RECEPTACLE NEMA TYPES - O CEILING MOUNTED PASSIVE INFRARED OCCUPANCY SENSOR INDICATED ON THE SPECIAL RECEPTACLE SCHEDULE. ELECTRICAL HANDHOLE OR VAULT LIGHTING TYPE TAG -COORDINATE WITH LIGHTING FIXTURE SCHEDULE CEILING MOUNTED PASSIVE INFRARED CORRIDOR OCCUPANCY SENSOR ® CEILING MOUNTED DUPLEX RCPT. UNLESS INDICATED OTHERWISE, 0 LUMINAIRE, SEE SCHEDULE FOR LIGHTING TYPE CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR 20A,125V, 1PH, 2P, 3W, NEMA 5-20R ELECTRICAL HANDHOLE OR VAULT WITH DECORATIVE LID 0 LUMINAIRE CONNECTED TO EMERGENCY SOURCE, SEE SCHEDULE FOR TYPE CEILING MOUNTED ULTRASONIC CORRIDOR OCCUPANCY SENSOR SURFACE MOUNTED RECEPTACLE ELECTRICAL IDENTIFICATION NUMBERING ® CAN LUMINAIRE, SEE SCHEDULE FOR LIGHTING TYPE � CEILING MOUNTED DUAL -TECHNOLOGY VACANCY SENSOR REFER TO "ST EQUIPMENT AND FACILITIES NUMBERING STANDARD' FOR MORE FLUSH FLOOR TYPE FLOOR BOX. INSTALL PER MANUFACTURER INSTRUCTION. . PENDANT OR CEILING MOUNTED ILLUMINATED EGRESS EXIT SIGN. WHERE O CEILING MOUNTED PASSIVE INFRARED VACANCY SENSOR DETAILED EXPLANATION USED, DIRECTIONAL ARROWS AS INDICATED. MOUNT 8'-0" ABOVE ❑® FLUSH FLOOR TYPE FLOOR BOX. INSTALL PER MANUFACTURER 'LXX'-'YYYY'-'ZZ' (EXAMPLE) FINISHED FLOOR, UNLESS INDICATED OTHERWISE. CEILING MOUNTED ULTRASONIC VACANCY SENSOR INSTRUCTION. RECEPTACLE NEMA TYPES INDICATED ON THE SPECIAL RECEPTACLE SCHEDULE. ZZ =INSTANCE NUMBER ~ WALL MOUNTED ILLUMINATED EGRESS EXIT SIGN. WHERE USED, O CEILING MOUNTED PHOTO SENSOR DIRECTIONAL ARROWS AS INDICATED. MOUNTED 8'-0" AFF UNLESS O FLUSH FLOOR TYPE POKE-THRU WITH DUPLEX RECEPTACLE. INSTALL YYYY = EQUIPMENT CODE - REPRESENTS A SPECIFIC KIND OF EQUIPMENT, COMPONENT, OR FACILITY. INDICATED OTHERWISE. O CEILING MOUNTED DAYLIGHT SENSOR PER MANUFACTURER INSTRUCTION. DENOTES POLE MOUNTED SINGLE ARM LUMINAIRE. POLE HEIGHT AS RC CEILING MOUNTED WATTSTOPPER LMRC-211/212 ROOM CONTROLLER LXX = LOCATION CODE INDICATED. O FLUSH FLOOR TYPE POKE-THRU WITH SPECIAL RECEPTACLE. INSTALL PER ELECTRICAL EQUIPMENT CODES ('YYYY') MANUFACTURER INSTRUCTION. RECEPTACLE NEMA TYPES INDICATED ON DENOTES POLE MOUNTED TWIN CONFIGURATION SINGLE ARM LUMINAIRE. 13a LIGHTING CONTROL DEVICE IDENTIFICATION (TYPICAL FOR ALL LIGHTING THE SPECIAL RECEPTACLE SCHEDULE. ACM ABB CONTROL MODULE MBP MAINTENANCE BYPASS / INDIVIDUAL LUMINAIRE TYPE AS INDICATED; POLE HEIGHT AS INDICATED. CONTROL DEVICE SYMBOLS WHERE USED) F IN WALL FURNITURE CONNECTION. INSTALL PER MFR INSTRUCTION. ATS AUTOMATIC TRANSFER SWITCH ISOLATION SWITCH BEB BATTERY ELECTRIC BUS MC MOTOR CONTROLLER DENOTES POLE MOUNTED TRIPLEX CONFIGURED SINGLE ARM LUMINAIRE. X_ LOWERCASE LETTER(S) = CONTROL ZONE INDIVIDUAL TYPE AS INDICATED; POLE HEIGHT AS INDICATED. BEBPC BEB PLUG CHARGER MCC MOTOR CONTROL CENTER POWER POLE WITH DUPLEX RECEPTACLES, LENGTH AS REQUIRED TO BRKR BREAKER MCS MOTOR CONTROL SWITCH RACK + DENOTES POLE MOUNTED QUADRAPLEX CONFIGURED SINGLE ARM CAPITAL LETTER(S) AND/OR NUMERAL =SPECIAL DESIGNATOR SUBSCRIPT DEFINED ABOVE P CR COMMUNICATION MDF MAIN DISTIBUTION FRAME LUMINAIRE. INDIVIDUAL LUMINAIRE TYPE AS INDICATED; POLE HEIGHT EXTEND ABOVE CEILING; SHADED AREA DENOTES TELECOMMUNICATION DISC DISCONNECT SWITCH MH MANHOLE AS INDICATED. DAYLIGHT ZONES RACEWAY. EVLV ELECTRIC VALVE MPC MINI POWER CENTER EUH ELECTRICAL UNIT HEATER MS MANUAL MOTOR STARTER a OUTDOOR WALL MOUNTED LUMINAIRE P POWER POLE WITH DUPLEX RECEPTACLES, LENGTH AS REQUIRED TO EXTEND ABOVE CEILING; SHADED AREA DENOTES TELECOMMUNICATION EWH ELECTRIC WATER HEATER MTR METER FACP FIRE ALARM CONTROL PANEL NRVEV NRV EV CHARGER GROUNDING AND LIGHTNING PROTECTION LEGEND RACEWAY. RECEPTACLE NEMA TYPES INDICATED ON THE SPECIAL FARP FIRE ALARM RELAY PANEL OS OCCUPANCY SENSOR OUTDOOR CANOPY LUMINAIRE RECEPTACLE SCHEDULE. FSD FIRE SMOKE DAMPER PB2 PANELBOARD - 208/120 V GEN GENERATOR PB4 PANELBOARD - 480/277 V GROUND ROD ON POWER AND LIGHTING SHEETS, ALL DEVICES IN THE GFD GROUND FAULT DETECTOR PBLV LOW VOLTAGE PULLBOX ® OUTLINED AREA ARE CIRCUITED TO THE SPECIFED PANEL �BTM01-PB2-105� UNLESS OTHERWISE NOTED. H TRACTION POWER 1500 V DC PBMV MEDIUM VOLTAGE PULLBOX BREAKER /SWITCH PC BUS PLUG COLUMN GROUND ROD WITH TEST WELL GENERAL LEGEND NOTE - - - - - - - HH HANDHOLE PE POLYETHYLENE -G■ GROUND CONNECTION HHLV LOW VOLTAGE HANDHOLE RD ROLL -UP DOOR 1 NUMERAL = CIRCUIT NUMBER HHMV MEDIUM VOLTAGE HANDHOLE SWBD SWITCHBOARD ** REFER TO GEN-GZN006 &GEN-GZN007 FOR ADDITIONAL G G GROUND CONDUCTOR TAP R-4332442 W' +36'► GFCI +(INCHES) HEIGHT IN INCHES ABOVE FINISHED FLOOR INV INVERTER SWGR SWITCHGEAR K LIGHTING KEY SWITCH T TRANSFORMER SYMBOLS AND LEGEND. G GROUNDING CONDUCTOR ►, LB LOAD BANK UPS UNINTERRUPTIBLE POWER ENGINEERING CAPITAL LETTER(S) = SPECIAL DESIGNATOR SUBSCRIPT DEFINED ABOVE LC LIGHTING CABINET SUPPLY FDEVELOPIMENT GROUND BUS BAR 0004k] o 11 /25/2025 LCP LIGHTING CONTROL PANEL VFD VARIABLE SPEED/FREQ DRIVE DESIGNED BY: D. TAFTFARREN DAFT �� sir Q'�e� o�'� 7 .paCO s 9 TJ?IDE Q cn w U wM;Vr cn J SCALE: NTS STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 DRAWING NO.: BT120-EPNO01 DRAWN BY: E. HAJAS FILENAME: S1-BT120-E-v2020 FACILITY ID: 0 57079 ��� BRT General Engineering Consultant z U_SOUNDTRANSIT ELECTRICAL BT120 CHECKED BY: CONTRACT No.: D. ANDERSON ��cisTER�° ��w �NAL G12 Zz/o2/z4112/10/2024520 RTA/CN 0205-24 SYMBOLS AND LEGEND SHEET No: REV: 0 0 12/10/2024 EH DA DT ISSUED FORBID APPROVED BY: D. TAFTFARREN SUBMITTED BY: R. PARGAS DATE: 12/10/2024 REVIEWED BY: J. ALTCHECH DATE: SUBMITTAL DATE: No. DATE DSN CHK APP REVISION