ELECTRIC
SYMBOLS
WIRING DEVICE LEGEND
POWER DISTRIBUTION / EQUIPMENT LEGEND
WIRING SYSTEM/RACEWAY/CABLE TRAY LEGEND
LIGHTING CONTROL DEVICE LEGEND
13
ONE OR TWO NUMERIC DIGIT BRANCH CIRCUIT NUMBER (13 IN THIS
FLOOR OR SURFACE MOUNTED 208V PANELBOARD
BRANCH CIRCUIT "HOMERUN", TIC MARKS INDICATE NUMBER OF
K
KEYED SWITCH
EXAMPLE)
- - - CONDUCTORS (INCLUDING NEUTRAL). #10 INDICATES AWG WIRE
3
THREE WAY.
+48"
DENOTES THE MOUNTING HEIGHT IN INCHES ABOVE THE FINISHED FLOOR.
FLOOR OR SURFACE MOUNTED 480V PANELBOARD
SIZE, AND 3/4" INDICATES CONDUIT SIZE. WIRE AND CONDUIT
GFCI
GFCI TYPE, WIRED FOR GFCI TRIP FOR DESIGNATED RECEPTACLE ONLY
�
SIZE IS APPLICABLE TO EACH CIRCUIT INDICATED FOR ENTIRE
4
FOUR WAY.
(NON-FEED-THRU INSTALLATION)
LENGTH OF CIRCUIT. ALL BRANCH CIRCUIT WIRING SHALL
3K
THREE WAY KEYED SWITCH.
RECESSED 208V PANELBOARD
INCLUDE A #12 AWG GROUND IN 3/4" CONDUIT. ARROW HEADS
4K
FOUR WAY KEYED SWITCH.
PR
PROJECTOR RECEPTACLE TO BE LOCATED WITHIN PROJECTOR OR
DENOTE A HOMERUN TO PANELBOARD. NUMBER OF
CEILING MOUNT
RECESSED 480V PANELBOARD
ARROWHEADS INDICATE NUMBER OF CIRCUITS IN CONDUIT.
D
WALL DIMMER.
"LP-1,3" INDICATES PANEL AND CIRCUIT NUMBERS.
WHEN USED ON DEMOLITION PLANS: DEMOLISH DEVICE AND FACEPLATE,
MD
MULT-LOCATION DIMMER, NUMERALS AS INDICATED FOR SINGLE
R
OUTLET BOX TO REMAIN.
- - q SWITCH LEG CONNECTED TO SWITCH "A"
LOCATION DIMMER.
WHEN USE ON NEW WORK PLANS: INSTALL DEVICE IN EXISTING OUTLET
5 GENERAL PURPOSE, DRY TYPE TRANSFORMER. 'T75' IS THE KVA
DP
DOUBLE POLE.
BOX.
RATING FOR THE TRANSFORMER. IN THIS EXAMPLE, 'T75'
SPD
SURGE PROTECTIVE DEVICE TYPE RECEPTACLE
REPRESENTS A TRANSFORMER RATED 75KVA.
R1 SWITCH LEG CONNECTED TO RELAY #1 IN LIGHTING CONTROL
XP
EXPLOSION PROOF
PANEL INDICATED.
TR
TAMPER RESISTANT TYPE RECEPTACLE
OS
OCCUPANCY SENSOR [WITH MANUAL OVERRIDE].
TVM
TICKET VENDING MACHINE
ATs AUTOMATIC TRANSFER SWITCH.
CONDUIT OR CABLE TURNING UP OR TOWARD THE OBSERVER
VS
VACANCY SENSOR/SWITCH
U
USB CHARGING
CONDUIT OR CABLE TURNING DOWN OR AWAY FROM THE
VD
VACANCY SENSOR/DIMMER
sPD SURGE PROTECTIVE DEVICE
OBSERVER
WP
WEATHER -RESISTANT, WEATHERPROOF WITH HINGED COVER
O
OCCUPANCY SENSOR/SWITCH
CONDUIT OR CABLE CHANGE IN ELEVATION
WP-WIN
WEATHER -RESISTANT TYPE, WEATHERPROOF WITH WHILE -IN -USE COVER
�-%' MOTOR CONNECTION; MOTOR HORSEPOWER AS SHOWN
OD
OCCUPANCY SENSOR/DIMMER
3 � -- SINGLE CONDUIT CAPPED
03
THREE WAY OCCUPANCY SENSOR
C)z
DUPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE, RECEPTACLES
CONNECTION POINT TO EQUIPMENT SPECIFIED IN OTHER DIVISIONS.
®
MULTIPLE CONDUITS, ALL INDIVIDUALLY CAPPED. WHERE
OR
OVERRIDE SWITCH
ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R.
RACEWAY, CONDUCTOR, TERMINATION AND CONNECTION IN THIS
NUMERIC DESIGNATION INDICATED, DENOTES QUANTITY OF
GFCI DUPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE,
DIVISION.
CAPPED CONDUITS. IN THIS EXAMPLE, THREE CAPPED CONDUITS
WP
WEATHERPROOF.
RECEPTACLES ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R.
100AS 7-1 FUSED SAFETY SWITCH, 100 AMP SWITCH, 80 AMP FUSES
M
SURFACE MOUNTED MOTOR RATED WITH OVERLOAD ELEMENTS,
80AF
CONDUIT WITH BUSHING
CONTINOUS CURRENT RATING AND QUANTITY OF POLES AS REQUIRED
DUPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE, RECEPTACLES
FOR EQUIPMENT SERVED.
ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R, MOUNTED 6"
����
ABOVE COUNTERTOP OR BACKSPLASH UNLESS OTHERWISE NOTED.
❑J NON -FUSED SAFETY SWITCH
RACEWAY CONTINUATION
RECESSED WALL MOUNTED SWITCH. INSTALL ADJACENT DEVICES UNDER
COMMON FACEPLATE, FOUR DEVICES MAXIMUM PER FACEPLATE. EVENLY
�
DUPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE, RECEPTACLES
DIVIDE DEVICES INTO SEPARATE GROUPS WHERE ADJCENT DEVICES
ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R ON AN
COMBINATION MOTOR STARTER DISCONNECT SWITCH
CABLE TRAY OR CONDUIT RACK
EXCEEDS FOUR.
EMERGENCY CIRCUIT.
SURFACE WALL MOUNTED SWITCH.INSTALL ADJACENT DEVICES UNDER
DUPLEX CONTROL RECEPTACLE. UNLESS INDICATED OTHERWISE
LOCAL CONTROLLER
COMMON FACEPLATE, FOUR DEVICES MAXIMUM PER FACEPLATE.
RECEPTACLES ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R.
LUMINAIRE LEGEND
EVENLY DIVIDE DEVICES INTO SEPARATE GROUPS WHERE ADJCENT
TWO DUPLEX QUAD RECEPTACLES. UNLESS INDICATED OTHERWISE
(QUAD) �
cTL CONTROL PANEL
DEVICES EXCEEDS FOUR.
RECEPTACES ARE FLUSH MOUNTED, 20A, 125V, 1PH, 2P, 3W, NEMA 5-20R.
NUMERAL =CIRCUIT NUMBER. ONLY WHEN THE OUTLINE AREA OF THE
3�
CEILING MOUNTED DUAL -TECHNOLOGY OCCUPANCY SENSOR
CIRCUIT IS PROVIDED. OTHERWISE PANEL NUMBER WILL BE INCLUDED
SIMPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE, RECEPTACLES
RB JUNCTION BOX WITH COVER PLATE
&J WITH CIRCUIT NUMBER.
CEILING MOUNTED DUAL -TECHNOLOGY CORRIDOR OCCUPANCY
ARE FLUSH MOUNTED, 20A, 1 25V, 1 PH, 2P, 3W, NEMA 5-20R.
A1E a�--- LOWERCASE ALPHANUMERIC CHARACTER = LIGHTING SWITCH
®
SPECIAL PURPOSE RECEPTACLE, UNLESS INDICATED OTHERWISE,
WALL MOUNTED JUNCTION BOX WITH COVER PLATE
OR CONTROL ZONE
'E' DESIGNATION LIGHTING FIXTURE WITH EMERGENCY SOURCE
SENSOR
RECEPTACLES ARE FLUSH MOUNTED. RECEPTACLE NEMA TYPES
-
O
CEILING MOUNTED PASSIVE INFRARED OCCUPANCY SENSOR
INDICATED ON THE SPECIAL RECEPTACLE SCHEDULE.
ELECTRICAL HANDHOLE OR VAULT
LIGHTING TYPE TAG -COORDINATE WITH LIGHTING FIXTURE
SCHEDULE
CEILING MOUNTED PASSIVE INFRARED CORRIDOR OCCUPANCY SENSOR
®
CEILING MOUNTED DUPLEX RCPT. UNLESS INDICATED OTHERWISE,
0 LUMINAIRE, SEE SCHEDULE FOR LIGHTING TYPE
CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR
20A,125V, 1PH, 2P, 3W, NEMA 5-20R
ELECTRICAL HANDHOLE OR VAULT WITH DECORATIVE LID
0 LUMINAIRE CONNECTED TO EMERGENCY SOURCE, SEE SCHEDULE
FOR TYPE
CEILING MOUNTED ULTRASONIC CORRIDOR OCCUPANCY SENSOR
SURFACE MOUNTED RECEPTACLE
ELECTRICAL IDENTIFICATION NUMBERING
® CAN LUMINAIRE, SEE SCHEDULE FOR LIGHTING TYPE
�
CEILING MOUNTED DUAL -TECHNOLOGY VACANCY SENSOR
REFER TO "ST EQUIPMENT AND FACILITIES NUMBERING STANDARD' FOR MORE
FLUSH FLOOR TYPE FLOOR BOX. INSTALL PER MANUFACTURER
INSTRUCTION.
. PENDANT OR CEILING MOUNTED ILLUMINATED EGRESS EXIT SIGN. WHERE
O
CEILING MOUNTED PASSIVE INFRARED VACANCY SENSOR
DETAILED EXPLANATION
USED, DIRECTIONAL ARROWS AS INDICATED. MOUNT 8'-0" ABOVE
❑®
FLUSH FLOOR TYPE FLOOR BOX. INSTALL PER MANUFACTURER
'LXX'-'YYYY'-'ZZ' (EXAMPLE)
FINISHED FLOOR, UNLESS INDICATED OTHERWISE.
CEILING MOUNTED ULTRASONIC VACANCY SENSOR
INSTRUCTION. RECEPTACLE NEMA TYPES INDICATED ON THE SPECIAL
RECEPTACLE SCHEDULE.
ZZ =INSTANCE NUMBER
~ WALL MOUNTED ILLUMINATED EGRESS EXIT SIGN. WHERE USED,
O
CEILING MOUNTED PHOTO SENSOR
DIRECTIONAL ARROWS AS INDICATED. MOUNTED 8'-0" AFF UNLESS
O
FLUSH FLOOR TYPE POKE-THRU WITH DUPLEX RECEPTACLE. INSTALL
YYYY = EQUIPMENT CODE - REPRESENTS A SPECIFIC KIND
OF EQUIPMENT, COMPONENT, OR FACILITY.
INDICATED OTHERWISE.
O
CEILING MOUNTED DAYLIGHT SENSOR
PER MANUFACTURER INSTRUCTION.
DENOTES POLE MOUNTED SINGLE ARM LUMINAIRE. POLE HEIGHT AS
RC
CEILING MOUNTED WATTSTOPPER LMRC-211/212 ROOM CONTROLLER
LXX = LOCATION CODE
INDICATED.
O
FLUSH FLOOR TYPE POKE-THRU WITH SPECIAL RECEPTACLE. INSTALL PER
ELECTRICAL EQUIPMENT CODES ('YYYY')
MANUFACTURER INSTRUCTION. RECEPTACLE NEMA TYPES INDICATED ON
DENOTES POLE MOUNTED TWIN CONFIGURATION SINGLE ARM LUMINAIRE.
13a
LIGHTING CONTROL DEVICE IDENTIFICATION (TYPICAL FOR ALL LIGHTING
THE SPECIAL RECEPTACLE SCHEDULE.
ACM ABB CONTROL MODULE MBP MAINTENANCE BYPASS /
INDIVIDUAL LUMINAIRE TYPE AS INDICATED; POLE HEIGHT AS INDICATED.
CONTROL DEVICE SYMBOLS WHERE USED)
F
IN WALL FURNITURE CONNECTION. INSTALL PER MFR INSTRUCTION.
ATS AUTOMATIC TRANSFER SWITCH ISOLATION SWITCH
BEB BATTERY ELECTRIC BUS MC MOTOR CONTROLLER
DENOTES POLE MOUNTED TRIPLEX CONFIGURED SINGLE ARM LUMINAIRE.
X_ LOWERCASE LETTER(S) = CONTROL ZONE
INDIVIDUAL TYPE AS INDICATED; POLE HEIGHT AS INDICATED.
BEBPC BEB PLUG CHARGER MCC MOTOR CONTROL CENTER
POWER POLE WITH DUPLEX RECEPTACLES, LENGTH AS REQUIRED TO
BRKR BREAKER MCS MOTOR CONTROL SWITCH
RACK
+ DENOTES POLE MOUNTED QUADRAPLEX CONFIGURED SINGLE ARM
CAPITAL LETTER(S) AND/OR NUMERAL =SPECIAL DESIGNATOR
SUBSCRIPT DEFINED ABOVE
P
CR COMMUNICATION MDF MAIN DISTIBUTION FRAME
LUMINAIRE. INDIVIDUAL LUMINAIRE TYPE AS INDICATED; POLE HEIGHT
EXTEND ABOVE CEILING; SHADED AREA DENOTES TELECOMMUNICATION
DISC DISCONNECT SWITCH MH MANHOLE
AS INDICATED.
DAYLIGHT ZONES
RACEWAY.
EVLV ELECTRIC VALVE MPC MINI POWER CENTER
EUH ELECTRICAL UNIT HEATER MS MANUAL MOTOR STARTER
a OUTDOOR WALL MOUNTED LUMINAIRE
P
POWER POLE WITH DUPLEX RECEPTACLES, LENGTH AS REQUIRED TO
EXTEND ABOVE CEILING; SHADED AREA DENOTES TELECOMMUNICATION
EWH ELECTRIC WATER HEATER MTR METER
FACP FIRE ALARM CONTROL PANEL NRVEV NRV EV CHARGER
GROUNDING AND LIGHTNING PROTECTION LEGEND
RACEWAY. RECEPTACLE NEMA TYPES INDICATED ON THE SPECIAL
FARP FIRE ALARM RELAY PANEL OS OCCUPANCY SENSOR
OUTDOOR CANOPY LUMINAIRE
RECEPTACLE SCHEDULE.
FSD FIRE SMOKE DAMPER PB2 PANELBOARD - 208/120 V
GEN GENERATOR PB4 PANELBOARD - 480/277 V
GROUND ROD
ON POWER AND LIGHTING SHEETS, ALL DEVICES IN THE
GFD GROUND FAULT DETECTOR PBLV LOW VOLTAGE PULLBOX
®
OUTLINED AREA ARE CIRCUITED TO THE SPECIFED PANEL
�BTM01-PB2-105� UNLESS OTHERWISE NOTED.
H TRACTION POWER 1500 V DC PBMV MEDIUM VOLTAGE PULLBOX
BREAKER /SWITCH PC BUS PLUG COLUMN
GROUND ROD WITH TEST WELL
GENERAL LEGEND NOTE
- - - - - - -
HH HANDHOLE PE POLYETHYLENE
-G■ GROUND CONNECTION
HHLV LOW VOLTAGE HANDHOLE RD ROLL -UP DOOR
1
NUMERAL = CIRCUIT NUMBER
HHMV MEDIUM VOLTAGE HANDHOLE SWBD SWITCHBOARD
** REFER TO GEN-GZN006 &GEN-GZN007 FOR ADDITIONAL
G G GROUND CONDUCTOR TAP
R-4332442
W' +36'►
GFCI
+(INCHES) HEIGHT IN INCHES ABOVE FINISHED FLOOR
INV INVERTER SWGR SWITCHGEAR
K LIGHTING KEY SWITCH T TRANSFORMER
SYMBOLS AND LEGEND.
G GROUNDING CONDUCTOR
►,
LB LOAD BANK UPS UNINTERRUPTIBLE POWER
ENGINEERING
CAPITAL LETTER(S) = SPECIAL DESIGNATOR SUBSCRIPT DEFINED ABOVE
LC LIGHTING CABINET SUPPLY
FDEVELOPIMENT
GROUND BUS BAR 0004k]
o 11 /25/2025
LCP LIGHTING CONTROL PANEL VFD VARIABLE SPEED/FREQ DRIVE
DESIGNED BY:
D. TAFTFARREN
DAFT
�� sir
Q'�e� o�'�
7
.paCO s
9 TJ?IDE
Q
cn
w
U
wM;Vr
cn
J
SCALE:
NTS
STRIDE BUS RAPID TRANSIT
SOUTH RENTON TRANSIT CENTER
BT105
DRAWING NO.:
BT120-EPNO01
DRAWN BY:
E. HAJAS
FILENAME:
S1-BT120-E-v2020
FACILITY ID:
0 57079
���
BRT General Engineering Consultant
z
U_SOUNDTRANSIT
ELECTRICAL
BT120
CHECKED BY:
CONTRACT No.:
D. ANDERSON
��cisTER�° ��w
�NAL G12
Zz/o2/z4112/10/2024520
RTA/CN 0205-24
SYMBOLS AND LEGEND
SHEET No: REV:
0
0
12/10/2024
EH
DA
DT
ISSUED FORBID
APPROVED BY:
D. TAFTFARREN
SUBMITTED BY:
R. PARGAS
DATE:
12/10/2024
REVIEWED BY:
J. ALTCHECH
DATE:
SUBMITTAL DATE:
No.
DATE
DSN
CHK
APP
REVISION