Loading...
HomeMy WebLinkAboutR-43324430 N 0 N w 0 N H m U) w IM W z Q ~I a I W D m 0 I 0 co 00 LO �o M I Q o � N U) N 0 0 CN LO � m ELECTRIC SYMBOLS GENERAL LEGEND NOTE SINGLE LINE DIAGRAM LEGEND SINGLE LINE DIAGRAM LEGEND SINGLE LINE DIAGRAM LEGEND ** SPD SURGE PROTECTIVE DEVICE. MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL 'VFD' 50 MOTOR; EQUIPMENT IDENTIFICATION AND HORSEPOWER AS REFER TO GEN-GZN006 & GEN-GZN007 FOR ADDITIONAL VFD- CONTROLLER. IN THIS EXAMPLE, DENOTES VARIABLE OR SYMBOLS AND LEGEND. ADJUSTABLE FREQUENCY DRIVE. UNLESS INDICATED OTHERWISE, EF-01 INDICATED. 200 LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. VARIABLE POWER FACTOR CORRECTION CAPACITOR BANK. KVAR E MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL OMMULTIFUNCTION METER SINGLE LINE DIAGRAM LEGEND 1 N.C. I 1 RVAT CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'RVAT' DENOTES REDUCED VOLTAGE AUTOTRANS FORMER, WHERE I LOAD INTERRUPTER SWITCH. INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD ELECTRONIC METERING MODULE: MICROPROCESSOR BASED 600 A RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER EMM FOR METERING, ANALYZING, WAVEFORM CAPTURE AND 1200A 52 MEDIUM VOLTAGE DRAWOUT CIRCUIT BREAKER. ENCLOSURES ARE RATED NEMA 1. CAPABLE OF PROVIDING MONITORED DATA PARAMETERS I N. C. 60A/3P IN THIS EXAMPLE. DENOTES 60 AMPERES / 3 POLE. LMU LOCAL MONITORING UNIT FOR SWITCHGEAR ASSEMBLIES CAPABLE OF UP TO 40 SEPARATE DATA INPUTS FROM 30A/3P NON -FUSED DISCONNECT / SAFETY SWITCH. BREAKER LSIG'S, EMM'S AND MFR'S; CONFIGURABLE DISPLAYSCREEN; LSIG F-30A IN THIS EXAMPLE, DENOTES FUSED WITH 30 AMPERE FUSES. DATA OUTPUT PORTS 250 AF LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER. J 225 AT / DENOTES FUSE RATING IN ACCORDANCE WITH MANUFACTURER'S N.C. F-MFR INSTRUCTIONS FOR THE UTILIZATION EQUIPMENT PROTECTED BY DENOTES ELECTRICAL CONDUIT 30A/3P THE FUSES. 3 FUSED DISCONNECT / SAFETY SWITCH. LSIG SOLID STATE TRIP UNIT WITH CT INPUT OR MODULE CAPABLE F-30A 1200/5 OF MONITORING AMPS, INSTANTANEOUS KW, PEAK KW AND N3R IN THIS EXAMPLE, DENOTES NEMA 3R ENCLOSURE. KWH. • 3 SN DENOTES SOLID NEUTRAL. MR PHASE CURRENT TRANSFORMER. O ENGINE. 1200/5 N.C. DENOTES NORMALLY CLOSED. OGENERATOR. N.O. DENOTES NORMALLY OPEN. 1 50/5 ZERO SEQUENCE CURRENT TRANSFORMER. GFP GROUND FAULT PROTECTION. DEVICE ADJUSTABLE PROTECTION OPTIONS. LONG, SHORT, LSIG 1AF INSTANTANEOUS, AND GROUND PICKUPS IN THIS EXAMPLE. ADJUSTABLE PROTECTION DESIGNATIONS m PT POTENTIAL TRANSFORMER. LOADBANK. 800 ) 00 AT / 100 VAI "AF" DENOTES FRAME SIZE, "AT" DENOTES TRIP SETTING. 1600A 480V 10KVA, w ® FUSE FRAME WITH 800A TRIP IN THIS EXAMPLE. DESIGNATION PROTECTION 1PH 120/240V m CPT CONTROL POWER TRANSFORMER. DENOTES SWITCH SIZE AND POLES. 30A, 3-POLE SWITCH IN L LONG PICKUP AND TIME DELAY PROTECTION FUSED DRAWOUT POTENTIAL TRANSFORMER. N. C. 30A/3P THIS EXAMPLE. S SHORT PICKUP AND TIME DELAY PROTECTION 0 T-P D2A DENOTES ORIENTATION OF SWITCH. NORMALLY CLOSED IN I INSTANTANEOUS PICKUP PROTECTION J 30KVA rnr�1 TRANSFORMER. (3) THIS EXAMPLE. G GROUND (EARTH) PICKUP AND TIME DELAY PROTECTION l4 480 V- 208/120 V -®—� (— FUSED POTENTIAL TRANSFORMER. F-30A DENOTES QUANTITY AND RATING OF FUSES. THREE 30A IN N NEUTRAL PROTECTION THIS EXAMPLE. o DESIGNATION PROTECTION DEVICE FEATURES / ACCESSORIES KT30Y r�� 480 V- 208/120 V ISOLATION TRANSFORMER. POWER FILTER. E ® MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'RVPW' NOTE: MULTIPLE DESIGNATIONS MAY BE ADJACENT TO DEVICE. 1 RVPW DENOTES REDUCED VOLTAGE PART -WINDING, WHERE INDICATED, KEY INTERLOCK 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER Z SHUNT TRIP + CABLE LUG TERMINATION II SURGE PROTECTIVE DEVICE. ENCLOSURES ARE RATED NEMA 1. E MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL Efl ELECTRONIC TRIP i ILA'S --* LIGHTNING ARRESTER. NUMERIC VALUE DENOTES QUANTITY. ® CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'RVSS' 33° 1 RVSS DENOTES REDUCED VOLTAGE SOLID STATE SOFT STARTER, R1 RELAY. WHERE INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE TRANSFER SWITCH. 'ATS' DENOTES AUTOMATIC TRANSFER TYPE, 'MTS' DENOTES MANUAL TRANSFER TYPE. 'P' OVERLOAD RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. SITE POWER DISTRIBUTION 'S' DENOTES PRIMARY POWER SOURCE; DENOTES L ATS SECONDARY POWER SOURCE; 'L' DENOTES TRANSFER MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL PAD MOUNTED EQUIPMENT AS IDENTITIFED SWITCH LOAD SIDE CONNECTION POINT. m CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'WD' III UPS AND BATTERY. 1 WD DENOTES WYE-DELTA STARTER, WHERE INDICATED, 'E' DENOTES E E PANELBOARD WITH A VOLTAGE OF 480V OR HIGHER. ELECTRONIC OR SOLID STATE OVERLOAD RELAY. UNLESS E E ELECTRICAL DUCTBANK 2-1 INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE PNL L1A RATED NEMA 1. -SL SL- SITE LIGHTING PANELBOARD WITH VOLTAGE UNDER 480V. DPM PNL L1A m MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL '1' 'MSCT' DIGITAL POWER METER CONTROLLER. IN THIS EXAMPLE, DENOTES NEMA SIZE, mE MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'FVNR' 1 MSCT DENOTES MULTI -SPEED CONSTANT TORQUE STARTER, WHERE dd I BATTERY. DENOTES FULL VOLTAGE NON WHERE INDICATED, 'E' INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD 1 FVNR -REVERSING, RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER G DENOTES ELECTRONIC OR SOLID STATE OVERLOAD RELAY. ENCLOSURES ARE RATED NEMA 1. STANDBY GENERATOR RATING SHOWN (KW/KVA) DM DIGITAL METER. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. 500/625 m MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'MSVT' E MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL SPD SURGE PROTECTIVE DEVICE. GROUNDING CONNECTION. ® CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'FVR' 1 MSVT DENOTES MULTI -SPEED VARIABLE TORQUE STARTER, WHERE 1 FVR DENOTES FULL VOLTAGE REVERSING, WHERE INDICATED, 'E' INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD (:1 3Y FEEDER / BRANCH CIRCUIT DESIGNATION. IN THIS EXAMPLE, DENOTES ELECTRONIC OR SOLID STATE OVERLOAD RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. 100:5 CURRENT TRANSFORMER RATING AS SHOWN '13Y' REFERS TO THE SYMBOL COLUMN OF THE FEEDER/BRANCH CIRCUIT SCHEDULE. THE ASSOCIATED ENCLOSURES ARE RATED NEMA 1. SYMBOL DESIGNATION DENOTES THE FEEDER / BRANCH m MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'MSCH' VT CIRCUIT REQUIREMENTS FOR THE ITEM TAGGED. E MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL POTENTIAL TRANSFORMER ® CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, '2 SPD' 1 MSCH DENOTES MULTI -SPEED CONSTANT HORSEPOWER STARTER, INTERLOCK. 1 2 SPD DENOTES TWO SPEED FULL VOLTAGE NON -REVERSING, WHERE INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD WHERE INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD RELAY. UNLESS INDICATED OTHERWISE, LOCAL OX R-4332443❑KKIRK-KEY MPR: MAIN PROTECTIVE RELA RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER CONTROLLER ENCLOSURES ARE RATED NEMA 1. FPR: FEEDER PROTECTIVE RE VEVELOPMENT ENGINEERING ENCLOSURES ARE RATED NEMA 1. ' msippo 11 /25/2025 DESIGNED BY: D. TAFTFARREN DAFT �� � sir Q'�e� o�'� 7 �aCO s 9 Q U) w w C/) URIDE J SCALE: NTS STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 DRAWING NO.: BT120-EPN002 DRAWN BY: E. HAJAS FILENAME: S1-BT120-E-v2020 FACILITY ID: 0 57079 �0 BRT General Engineering Consultant z U_ SOUND ELECTRICAL BT120 CHECKED BY: CONTRACT No.: D. ANDERSON ��c/STER�° NAL "-12 Zz/o2/z4 RTA/CN 0205-24 SYMBOLS AND LEGEND SHEET No: REV: 521 0 0 12/10/2024 EH DA DT ISSUED FOR BID APPROVED BY: D. TAFTFARREN SUBMITTED BY: R. PARGAS DATE: 12/10/2024 REVIEWED BY: J. ALTCHECH DATE: 12/10/2024 SUBMITTAL DATE: 12/10/2024 No. DATE DSN CHK APP REVISION