HomeMy WebLinkAboutR-43324440 N 0 N W 0 N H m U) 0 W C� I W z Q ry I 0 a ry I W D m 0 I 0 co 00 LO a 0 � I >Q O N 66 U) 0 N O � Cfl LO cy) m ELECTRIC SYMBOLS I GENERAL NOTES I MOUNTING HEIGHT SCHEDULE I 1. WHERE "SPLIT CIRCUIT" IS INDICATED, EXTEND SPLIT CIRCUIT HOME RUNS TO A COMMON JUNCTION BOX ABOVE THE PANEL INDICATED. TIE HOME RUNS TOGETHER USING SPLICE KIT AND EXTEND A SINGLE SET OF CONDUCTORS TO CIRCUIT BREAKER NUMBER INDICATED. WIRING USED IN SPLIT CIRCUITS SHALL BE THE SAME SIZE. 2. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND INDICATE THE GENERAL LOCATION OF OUTLETS, EQUIPMENT, AND THE CIRCUIT ARRANGEMENT OF THE REQUIRED WIRING. ALTHOUGH THE DRAWINGS DO NOT NECESSARILY INDICATE THE ACTUAL ROUTES OF SURFACE MOUNTED CONDUITS, WHERE INDICATED, THEY SHALL BE FOLLOWED AS CLOSELY AS PROPER COORDINATION WITH THE WORK OF OTHER TRADES AND SPACE WILL PERMIT. WHERE CONDUIT RUNS ARE NOT SHOWN ON THE DRAWINGS, SUCH AS FOR MECHANICAL EQUIPMENT, COORDINATE CONDUIT RUNS WITH THE WORK OF OTHER TRADES AND STRUCTURE. SIMPLIFY INSTALLATION WHEREVER POSSIBLE, BUT SUBJECT TO APPROVAL BY THE COR FOR VISUAL AND STRUCTURAL REASONS. IT IS NOT WITHIN THE SCOPE OF THE DRAWINGS TO SHOW ALL NECESSARY OFFSETS, BENDS, PULL BOXES, AND OBSTRUCTIONS. THE DRAWINGS ARE NOT INTENDED TO BE SCALED, REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS. 3. NOT ALL SYMBOLS SHOWN IN LEGENDS ARE USED - SEE DRAWINGS FOR APPLICABLE DEVICES. 4. MOUNTING HEIGHTS INDICATED AS '+##' ARE MEASURED FROM FINISHED FLOOR UNLESS OTHERWISE NOTED. 5. PROVIDE LABELS DENOTING EQUIPMENT SERVED AND CORRESPONDING CIRCUIT NUMBER ON DEDICATED RECEPTACLES. 6. SEAL PENETRATIONS OF FIRE- AND/OR SMOKE -RATED CONSTRUCTION WITH U.L. APPROVED STOPPING MATERIAL TO RESTORE THE ORIGINAL RATING OF THE PENETRATED CONSTRUCTION. 7. SEAL PENETRATIONS OF NON -RATED PARTITIONS WITH APPROVED MATERIAL TO PREVENT AIRFLOW AND DEBRIS. 8. MOUNTING HEIGHTS SHOWN ON ELECTRICAL, COMMUNICATIONS, AND SYSTEMS DRAWINGS ARE FOR BIDDING PURPOSES ONLY. REFER TO INTERIOR ELEVATION DRAWINGS FOR MOUNTING HEIGHTS OF DEVICES AND EQUIPMENT. WHERE DISCREPANCIES OCCUR, INTERIOR ELEVATIONS TAKE PRECEDENCE. 9. SUPPORT BOXES AND CONDUIT ABOVE CEILING INDEPENDENTLY. DO NOT SUPPORT FROM SUSPENDED CEILING SYSTEM. 10. WHERE CONCEALED BY INACCESSIBLE FINISHES, PROVIDE ACCESS DOORS FOR JUNCTION & PULL BOXES, CONTROL DEVICES & EQUIPMENT, DISCONNECT SWITCHES, AND OTHER ITEMS REQUIRING SERVICE, MAINTENANCE, OPERATION, OR ADJUSTMENT. SIZE AND LOCATE ACCESS DOORS FOR EASE OF PERFORMANCE OF THE FUNCTION INTENDED. DOORS SHALL NOT BE SMALLER THAN 18" x 18". COORDINATE LOCATION OF ACCESS DOORS WITH AFFECTED TRADES. SUBMIT PANEL LOCATIONS FOR APPROVAL BY THE ARCHITECT PRIOR TO INSTALLATION. 11. INSTALL ADJACENT DEVICES UNDER A COMMON FACEPLATE, WITH NO MORE THAN FOUR DEVICES IN A SINGLE FACEPLATE. WHERE MORE THAN FOUR ADJACENT DEVICES ARE PRESENT, EVENLY DIVIDE DEVICES INTO SEPARATE GROUPS OF NO LESS THAN TWO DEVICES PER GROUP. PROVIDE BARRIERS WITHIN BOXES TO SEPARATE DEVICES WHERE DIFFERENT CIRCUITS AND DIFFERENT VOLTAGES ARE PRESENT. 12. PROVIDE LUGS AS NECESSARY FOR TERMINATING OVERSIZED CONDUCTORS OR OTHERWISE MAKE PROVISIONS FOR TERMINATING OVERSIZED CONDUCTORS IN DEVICES WHOSE LUGS DO NOT ACCEPT THE OVERSIZED CONDUCTOR SIZE. 13. SHARED NEUTRAL CONDUCTORS ARE PROHIBITED. 14. ALL OUTAGES MUST BE SCHEDULED WITH A MINIMUM OF 21 CALENDAR DAYS IN ADVANCE. NOTIFY SOUND TRANSIT PERSONNEL (CONTRACTING OFFICER). MAKE AN APPLICATION FOR OUTAGES TO SOUND TRANSIT HIGH VOLTAGE FACILITY DEPARTMENT WITH THE PROVIDED REQUEST FORMS AND SUBMIT FOR APPROVAL FOR THE OUTAGES. NO OUTAGES WILL TAKE PLACE WITHOUT WRITTEN AUTHORIZATION TO SOUND TRANSIT PERSONNEL BY THE CONTRACTOR. OUTAGES CAN BE CANCELED BY SOUND TRANSIT UP UNTIL THE SCHEDULED TIME OF THE OUTAGE. OUTAGES SHALL BE COORDINATED WITH SOUND TRANSIT PERSONNEL (CONTRACTING OFFICER) TO MINIMIZE TOTAL OUTAGES TO THE FACILITY. 15. ADJUST WIRE SIZES TO COMPENSATE FOR VOLTAGE DROP. THE LENGTH OF A SINGLE PHASE 20A CIRCUIT (ONE-WAY) SHALL NOT EXCEED THE FOLLOWING VALUES (BASED ON 16A LOAD): MAXIMUM 20A CIRCUIT LENGTH SCHEDULE CONDUCTOR SIZE (AWG) MAXIMUM 120V CIRCUIT LENGTH MAXIMUM 277V CIRCUIT LENGTH #12 60'-0" 135-0" #10 90'-0" 210'-0" #8 140'-0" 330'-0" #6 225-0" 525'-0" 0 1 12/10/2024 I EH I DA I DT I ISSUED FOR BID No. I DATE I DSN I CHK I APP I REVISION DESIGNED BY: D. TAFTFARREN DRAWN BY: E. HAJAS CHECKED BY: D.ANDERSON APPROVED BY: D. TAFTFARREN .;acobs SUBMITTED BY: 12/O2/24 I R. PARGAS MOUNTING HEIGHT SCHEDULE DEVICES/EQUIPMENT MOUNTING HEIGHT (AFF) MEASURED TO: RECEPTACLES AS INDICATED ON LEGEND/PLANS CENTER TOGGLE SWITCHES 4'-0" TOP WALL DIMMERS 4'-0" TOP MANUAL MOTOR STARTERS 4'-0" TOP OCCUPANCY SENSORS - WALL MOUNTED 4'-0" TOP LIGHTING CONTROL PANEL 6'-6" TOP LIGHTING CONTROL STATION 4'-0" CENTER JUNCTION BOXES AS INDICATED ON LEGEND/PLANS CENTER MONITORING/CONTROL PANEL 5'-0" TOP SURFACE METAL RACEWAYS AS INDICATED ON LEGEND/PLANS TOP PANELBOARDS 6'-6" TOP DISCONNECT SWITCHES 5'-0" TOP AUTOMATIC TRANSFER SWITCHES 6'-6" TOP MANUAL TRANSFER SWITCHES 6'-6" TOP CONTROL STATIONS 6'-6" TOP TVSS (NON -INTEGRAL) 6-0" (NTE) TOP MAGNETIC MOTOR CONTROLLERS 6'-6" TOP LIGHTING CONTACTORS ENCLOSURES 6'-6" TOP INDIVIDUAL CKT BREAKERS ENCLOSURES 6'-6" TOP EMERGENCY POWER OFF SWITCHES 5'-6" CENTER TIME SWITCHES 6'-6" TOP TELECOMMUNICATIONS OUTLETS 1'-6" CENTER TELECOMMUNICATIONS OUTLETS - OVER COUNTER 0'-6" CENTER (OVER TOP OF COUNTER) GROUND FAULT CIRCUIT INTERRUPTER 4'-0" CENTER GROUND BUS BARS 2'-0" CENTER INTEGRATED COMMUNICATIONS PANELS 6'-0" TOP GENERATOR REMOTE ALARM ANNUNCIATOR 5'-0" TOP GENERATOR TERMINAL BLOCKS 5'-0" TOP BAS TERMINAL BLOCKS 5'-0" TOP GENERATOR STOP SWITCH 5'-6" CENTER GENERATOR TANK FUEL LEVEL INDICATORS 5'-0" TOP UPS BATTERY MONITORING / CONTROL PANEL 5'-0" TOP UPS REMOTE MONITORING PANEL 5'-0" TOP MAIN SWITCHGEAR BATTERY CHARGER 5'-0" TOP RELAY CONTROL PANELS 6'-6" TOP MOUNTING HEIGHT SCHEDULE NOTES: 1. USE ABOVE INDICATED MOUNTING HEIGHTS UNLESS INDICATED OTHER WISE ON DRAWINGS OR SPECIFICATIONS. 2. COORDINATE MOUNTING HEIGHTS WITH FIELD CONDITIONS, OTHER TRADES, AND RELATED EQUIPMENT. 3. REDUCE MOUNTING HEIGHTS OF FIRE ALARM VISUAL AND AUDIO/VISUAL ALARMS WHERE REQUIRED TO MAINTAIN 6" MINIMUM SPACING FROM CEILING. SCALE: Q w NTS Q FILENAME: STmRIDE U w J S 1-BT120-E-v2020 BRT General Engineering Consultant z " SOUNDTRANSIT CONTRACT No.: RTA/CN 0205-24 DATE: REVIEWED BY: DATE: SUBMITTAL DATE: 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 ELECTRICAL GENERAL NOTES AND MOUNTING R-4332444 DEVELOPMENT ENGINEERING msippo 11 /25/2025 U DRAWING NO.: BT120-EPNO03 FACILITY ID: BT120 SHEET No: REV: 522 0