HomeMy WebLinkAboutR-4332445N C'7 0 W 0 N O N IiI 0 N H m U w C� I z Q I 0 a ry I D m 0 I 0 co 00 LO � M 0-o I LOa U) N � L N O O �p N cy) co � N co m KEY NOTES: 119 MOUNT GFCI RECEPTACLES HORIZONTALLY ABOVE COUNTER AT 36" 301 AFF. ATTACH PHOTOCELL TO HORIZONTAL SUPPORT AT 11' ABOVE FINISHED GRADE, UNDER THE CANOPY WITH SENSOR AIMED NORTH. 120 LOCATE DISCONNECT SWITCH BENEATH TANKLESS WATER HEATER. 303 ATTACH PHOTOCELL TO EXTERIOR WALL AT 11' ABOVE FINISHED SEE PLUMBING PLANS DETAIL 6/BT120-MPD001. GRADE WITH SENSOR AIMED NORTH. 121 INSTALL RECEPTACLES TO BOTTOM SIDE OF CABLE TRAY. 304 COORDINATE WITH DIV 27 CONTRACTOR INSTALLING THE CABLE TRAY. TYPICAL OF RACK RECEPTACLES IN ALL IT ROOMS. CONNECT PHOTOCELL TO PANEL BT120-LCP-01 USING CAT6 CABLE RUN IN 3/4" CONDUIT. 305 CONNECT PHOTOCELL TO PANEL BT120-LCP-02 USING CAT6 CABLE 122 PROVIDE 5/8" X 10' COPPER GROUND ROD IN LIGHTING HANDHOLES RUN IN 3/4" CONDUIT. LOCATED IN THE SCL EASEMENT AREA UNDER POWER LINES. BOND WITH #6 GND TO LIGHT POLE. 307 PENDANT MOUNT FIXTURE(S) TO HANG 10' 0" AFF FROM TOP OF FIXTURE. 123 INDOOR UNIT POWERED BY OUTDOOR UNIT. PROVIDE 4-WIRE #14 AWG CABLE BETWEEN INDOOR AND OUTDOOR MECHANICAL UNIT. SEE 308 PENDANT MOUNT FIXTURES TO HANG 8' 0" AFF FROM TOP OF MECHANICAL SHEET BT120-MHS002 PLANS FOR INDOOR/OUTDOOR FIXTURE. UNIT PAIRING. O124 INDOOR UNIT POWERED BY BT120-HPMP-06 BRANCH UNIT. PROVIDE 309 PENDANT MOUNT FIXTURES TO HANG 8' 6" AFF FROM TOP OF FIXTURE. 3#14 AWG PLUS #14 AWG GND CABLE BETWEEN INDOOR UNIT AND BRANCH UNIT. SEE MECHANICAL SHEET BT120-MHS001 FOR CONNECTION SCHEMATIC. 310 USE CHASE PROVIDED BY STRUCTURAL AT COLUMNS FOR LIGHTING CONDUIT. SEE POWER SHEET BT120-EPP212 THROUGH BT120-EPP214 FOR CONDUIT PLAN. 12 THE LIGHTNING PROTECTION SYSTEM IS A DEFERRED DESIGN BY THE LIGHTNING PROTECTION SYSTEM CONTRACTOR. PROVIDE LIGHTNING PROTECTION SYSTEM. SEE SPECIFICATIONS FOR ADDITIONAL 311 MOUNT FIXTURE SO IT IS MOUNTED 8' 0" AFG. COORDINATE WITH REQUIREMENTS. ARCHITECTURE. 130 480V LIGHTING CIRCUITS TO INDIVIDUALLY FEED THROUGH SEPARATE 312 MOUNT FIXTURE SO IT IS MOUNTED 10' 0" AFG. COORDINATE WITH LIGHTING CONTROLLER CONTACTORS. ARCHITECTURE. 131 120V LIGHTING CIRCUITS TO INDIVIDUALLY FEED THROUGH SEPARATE 313 TERMINATE AND CAP CONDUIT UNDERGROUND FOR FUTURE USE. LIGHTING CONTROLLER CONTACTORS. PROVIDE MARKING SIGN ABOVE GRADE DENOTING THE BURIED CONDUIT END LOCATIONS. 132 ALL SITE LIGHTING CIRCUITS TO PANEL BT120-PB4-01 ON THIS SHEET. 133 CONDUIT STUB UP THROUGH COLUMN RACEWAY FOR LIGHTING AND VMS SIGNAGE. 13 2'X2' PIECE OF 3/4" PLYWOOD MOUNTED 5' AFF FOR PSE AMR/AMI REPEATER. PROVIDE DEDICATED 120V RECEPTACLE BELOW PLYWOOD. 138 8"X8"X6" NEMA 3R ENCLOSURE FOR PSE ANTENNA. MOUNT ON OUTSIDE WALL 8' TO 10' ABOVE FINISHED GRADE. 139 PROVIDE 2" CONDUIT FROM NEMA 3R ENCLOSURE STUBBED INTO ELECTRICAL ROOM ABOVE PLYWOOD BOARD. 140 PROVIDE GROUNDING FOR FENCE AT FENCE END POSTS, POSTS EVERY 160 FEET, AND POSTS ON EACH SIDE OF AN SCL OVERHEAD LINE. SEE SHEET BT120-EPD111 FOR GROUNDING DETAIL. 141 CONDUIT GROUP INCLUDES CONDUIT TAGS: BT120-N4-202, BT120-E4-202A, BT120-E4-202B, BT120-N2-201, BT120-SC-203, BT120-SC-204. 142 CONDUIT GROUP INCLUDES CONDUIT TAGS: BT120-E4-201A, BT120-E4-201 B, BT120-E4-203, BT120-SC-201, BT120-SC-202, BT120-N2-202. 143 CONDUIT GROUP INCLUDES CONDUIT TAGS: BT120-N4-201A AND BT120-N4-201 B. 144 PROVIDE RECEPTACLE FOR FLOOD CONTROL SYSTEM. COORDINATE EXACT LOCATION WITH PLUMBING CONTRACTOR PRIOR TO ROUGH -IN. 14 CONTRACTOR TO INSTALL CONDUIT TO EXISTING SERVICE TAP LOCATION AND TERMINATE CONDUIT PER PSE REQUIREMENTS. CONTRACTOR WILL NEED TO COORDINATE CONDUIT TERMINATION REQUIREMENTS WITH PSE PRIOR TO INSTALLATION OF 4"C AND 2/0 SVC CABLE. 148 CONTRACTOR SHALL FURNISH AND INSTALL THE DUAL EV CHARGER. THE DUAL EV CHARGER SHALL BE CHARGEPOINT CT4021 DUAL PORT K2 BOLLARD MOUNT. 149 ALL PSE TRANSFORMER AND VAULTS PROVIDED BY PSE. CONTRACTOR SHALL COORDINATE EXCAVATION OF VAULT PITS WITH PSE SERVICE DRAWING. DESIGNED BY: D. TAFTFARREN DRAWN BY: E. HAJAS 2 06/27/2025 EH DA DT ADDENDUM #2 CHECKED BY: 1 06/13/2025 EH DA DT ADDENDUM #1 D. ANDERSON 0 12/10/2024 EH DA DT ISSUED FORBID APPROVED BY: No. DATE DSN CHK APP REVISION D. TAFTFARREN .;acobs SUBMITTED BY: 6127125 R. PARGAS 1 DATE: 12/10/2024 Q w STmRIDE U U) C/) W J BRT General Engineering Consultant z LL REVIEWED BY: J. ALTCHECH SCALE: M;Vmr=" NTS FILENAME: S 1-BT120-E-v2020 SOUNDTRANSIT CONTRACT No.: RTA/CN 0205-24 DATE: SUBMITTAL DATE: 12/10/2024 12/10/2024 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 ELECTRICAL PROJECT KEYNOTE LIST R-4332445 DEVELOPMENT ENGINEERING msippo 11 /25/2025 DRAWING NO.: BT120-EPNO04 FACILITY ID: BT120 SHEET No: REV: 523 2