co m
1 06/13/2025 EH DA DT ADDENDUM #1
0 12/10/2024 JS LG DT ISSUED FOR BID
No. I DATE I DSN I CHK I APP I REVISION
T-
N
(L
J
u.i w
z_ '
0
J T-
(j m
Q �
0
W
W
U)
DESIGNED BY:
J. SAXER
DRAWN BY:
E. HAJAS
CHECKED BY:
L. GLASER
APPROVED BY:
D. TAFTFARREN
1.5 1.6
A
BT120-EPE213
B
I I
BT120-EPE213
LIGHTING PLAN - SECTOR B
SCALE: 1 /8" = 1'-0"
AFT F
pacobs
57079
R&GISTBY- w�
�sSI�NAL V, SUBMITTED BY:
6113125 R. PARGAS
BT120-ELP211
STmRIDE
BRT General Engineering Consultant
DATE: REVIEWED BY:
12/10/2024 J. ALTCHECH
Q w
cn�
W J
J
z SOUNDTRANSIT
DATE:
12/10/2024
SCALE:
1/8" = 1'-0"
FILENAME:
S 1-BT120-E-v2020
CONTRACT No.:
RTA/CN 0205-24
SUBMITTAL DATE:
12/10/2024
C D
PLATFORM
JE
F
G
H
CORE
FACILITY
7)111 KEY PLAN
GENERAL NOTES:
1. LT FIXTURES TO BE ATTACHED TO COLUMNS
ARE TO BE MOUNTED SO THAT THEIR LENSES
ARE 9'-0" ABOVE THE GROUND BELOW. ALIGN
AND COORDINATE WITH ARCHITECTURE FOR
PENETRATION, CONDUIT FEED AND MOUNTING
SCREWS.
KEY NOTES:
310 USE CHASE PROVIDED BY STRUCTURAL AT
COLUMNS FOR LIGHTING CONDUIT. SEE
POWER SHEET BT120-EPP212 THROUGH
BT120-EPP214 FOR CONDUIT PLAN.
N
8 4 0 8 16
SCALE IN FEET
DEVELOPMENT ENGINEERING
msippo 11 /25/2025 R-4332450
STRIDE BUS RAPID TRANSIT
SOUTH RENTON TRANSIT CENTER
BT105
ELECTRICAL
LIGHTING PLAN - SECTOR B
CANOPY
DRAWING NO.:
BT120-ELP213
FACILITY ID:
BT120
SHEET No: REV:
528 1