Loading...
HomeMy WebLinkAboutR-4332475N co co W C� J LL O U) co co aD 0 I N O N W O N H m 0 N 0 N U (D O I U O J I Q rI cy), � U E 00 :3 Lo a N U) O L a� N U) 0 N � U 3.A 10"Wx10Dx24"H LOW VOLTAGE PULLBOX (3) 3" NETWORK CONDUITS TRY EAST ELEVATION SCALE: 3/8" = 1'-0" 1 06/13/2025 EH DA DT ADDENDUM #1 0 12/10/2024 EH DA DT ISSUED FORBID No. DATE DSN CHK APP REVISION 3.113 NOTE: PROVIDE LOW VOLTAGE AND DC PULLBOXES FOR ALL CONDUIT RISER LOCATIONS IN GANTRY. BT120-SC-181 BT120-SC-182 BT120-SC-183 24"Wx18Dx24"H DC PULLBOX E-STOP - (9) 3" DC CONDUITS BT120-DBDC-111 BT1 20-DBSC-1 11 IN BT120-EPP231 DESIGNED BY: D. TAFTFARREN DRAWN BY: I. KARNAS CHECKED BY: D.ANDERSON APPROVED BY: D. TAFTFARREN "C" CHANNEL 'S, 3'-0" LONG DELETED E RACK, 3 EA STANCHION .;acobs SUBMITTED BY: R. PARGAS STANCHION FOR MOUINTING CABLE RACKS OUTGOING CONDUITS TO GANTRY 4 PULLING IRONS, 1 EACH CORNER COMPACTED GRAVEL, 12" DEEP MIN, 3/4" MINUS GROUT TO FULL WALL THICKNESS �AROUND CONDUITS AT KNOCKOUTS, TYP #4/OG ROUND ROD 10 CF 1" TO 1-1/2" GI ALL AROUND DRAIN 2 1/2" DIA. GROUND ROD KNOCKOUT 2 PLACES IN FLOOR BEB CHARGING HANDHOLE SECTION SCALE: NTS 4b5TmRIDE BRT General Engineering Consultant DATE: REVIEWED BY: 12/10/2024 J. ALTCHECH SCALE: Q w mrr AS NOTED Q FILENAME: U)� w J S 1-BT120-E-v2020 z J U- SOUNDTRANSIT CONTRACT No.: RTA/CN 0205-24 DATE: SUBMITTAL DATE: 12/10/2024 12/10/2024 L, INCOMING CONDUITS FROM CHARGING YARD STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 ELECTRICAL DETAILS SOUTH RENTON TRANSIT CENTER R-4332475 DEVELOPMENT ENGINEER*40 msippo 11 /25/2025 '01 DRAWING NO.: BT120-EPD102 FACILITY ID: BT120 SHEET No: REV: 553 1