HomeMy WebLinkAboutR-4332476N C'7 C'7 0 W 0 N 0 N > W 0 N m co U w C� �I z Q ~I 0 n I W am 0 I 0 co 00 2� d M �o p Q7 N C/) 'zj- D o N o LO co m NUMBER OF CONDUITS AS REQUIRED MIN 3/4"x5"x FULL WIDTH OF ENCASEMENT NEOPRENE BRG PAD CORBEL, SEE STRUCTURAL DRAWINGS ADAPTER REQUIRED FOR PVC CONDUITS CONDUIT, SIZE PER PLANS /411 PREMOLDED JOINT FILLER RGS CONDUIT, 6" MIN SST CLAMP, TYP ELEVATION CLOSED CELL NEOPRENE - M RGS CONDUIT HUB PROVIDE CONTINUOUS GROUND PATH PER NEC REQUIREMENTS 245 HOOPS, 2" CLEAR EXPANSION/DEFLECTIONCOUPLING BUILDING FOUNDATION AND CORBEL #4 DOWELS @ 1'-6" ADHESIVE DOWELS W/ 6" MIN EMBEDMENT. MIN 2 TOP AND BOTTOM. (4 TOTAL) NOTES: 1. DETAIL APPLIES TO CONDUIT AT BUILDING INTERFACES. CONCRETE ENCASED DUCT SCALE: NTS SUPPORT, NOTE 3 FLEX CONDUIT TO MOTOR OR OTHER DEVICE FLOOR FLANGE AND A MINIMUM OF 4 CONCRETE ANCHORS FLOOR — :o. o. 0 0�<p o 0 0 z 0 RIGID METAL CONDUIT (1" MIN SIZE) "T" CONDULET o. •o. o. o, o. p o0 oa<p o < O O O NOTES: 1. INSTALLATION OF CONDUIT TO A MOTOR OR OTHER DEVICE WHERE A FLEXIBLE CONNECTION IS REQUIRED AND NO JUNCTION BOXES OR CONTROL DEVICES ARE REQUIRED SHALL BE MADE IN ACCORDANCE WITH THIS DETAIL. 2. ALL HARDWARE SHALL BE STAINLESS STEEL. 3. SUBMIT FINAL DESIGN AND CALCULATIONS FOR SUPPORT AND ANCHORAGE AS SPECIFIED. CONDUIT TO EQUIPMENT FROM CEILING SCALE: NTS 0 12/10/2024 EH DA DT ISSUED FOR BID No. DATE DSN CHK APP REVISION 75 Xry QO 2U pw wz� Xm� LU X O�� zoo J Q o =w U)=) = J I- Q (D z w J DESIGNED BY: D. TAFTFARREN DRAWN BY: I. KARNAS CHECKED BY: D.ANDERSON APPROVED BY: D. TAFTFARREN GROUND WIRE EQUIPMENT ENCLOSURE METAL CONDUIT GROUNDING BUSHING NOTES: 1. THE ENDS OF ALL CONDUITS REQUIRED TO BE GROUNDED BY THE SPECIFICATIONS SHALL BE GROUNDED IN ACCORDANCE WITH THIS DETAIL. CONDUIT GROUNDING SCALE: NTS 1 GROUT FILL CEL CONTAINING BO.' DO NOT LOCA7 IN A REINFORCE CEL PLAN SINGLE DEVICE BOX WITH PLASTER RING E DEVICE BOX 'LASTER RING Cn z O Q U LL U w d W W o_ NOTES: SECTION 1. ALL WIRING DEVICE BOXES MOUNTED IN CONCRETE BLOCK WALLS SHALL BE INSTALLED IN ACCORDANCE WITH THIS DETAIL. 2. PARALLEL CONDUIT NOT PERMITTED IN CELLS WITH VERTICAL REINFORCING. DO NOT CUT OR DISPLACE VERTICAL REINFORCING OR DOWELS. DEVICE MNT BOX IN CONCRETE MASONRY WALL SCALE: NTS pacobs �0" SUBMITTED BY: 12/O2/24 R. PARGAS Q w TmRIDE U U)C/) 49 W J BRT General Engineering Consultant z U_ DATE: REVIEWED BY: 12/10/2024 J. ALTCHECH LOCK NUT BOTTOM OF STEEL OR f' f"%A Inn rTr C -rn1 1f' -r1 Inr z DOUBLE RACK NOTES: SEISMIC BRACE FO ROOF OR FOP OF FLOOR 3EAM ABOVE JNLESS BRACED FO WALL. 1. LENGTH VARIES WITH NUMBER OF CONDUITS TO BE SUPPORTED AND SPACING BETWEEN CONDUITS. 2. SUBMIT FINAL DESIGN AND CALCULATIONS FOR SUPPORT AND ANCHORAGE AS SPECIFIED. 3. USE STAINLESS STEEL HARDWARE IN WET AND/OR CORROSIVE AREAS. 4. SPACE CONDUIT SUFFICIENTLY TO ALLOW REMOVAL OF ONE CONDUIT WITHOUT DISTURBING ADJACENT CONDUITS. CONDUIT RACKING SYSYEM SCALE: NTS SCALE: NTS FILENAME: S 1-BT120-E-v2020 SOUNDTRANSIT CONTRACT No.: RTA/CN 0205-24 DATE: SUBMITTAL DATE: 12/10/2024 12/10/2024 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 ELECTRICAL DETAILS SOUTH RENTON TRANSIT CENTER R-4332476 DEVELOPMENT ENGINEERING U msippo 11 /25/2025 11 DRAWING NO.: BT120-EPD103 FACILITY ID: BT120 SHEET No: REV: 554 p