Loading...
HomeMy WebLinkAboutR-4332478N C'7 C'7 O 0 LU 0 N 0 N IiI 0 N H m U) 0 w C� I z Q ry I 0 a ry I D m of 0 co 00 LO co a 0I U) o � L o (N o cY) N co �_ co m GROUNDING ELECTRODECONDUCTORS, BARE COPPERSIZE AS SHOWN ON DRAWINGS EXOTHERMIC WELDED CONNECTION (CADWELD OR EQUIVALENT) COPPER CLAD GROUND ROD NOTES: 1. TOP OF GROUND ROD SHALL BE SAND BEDDED 6" MIN BELOW GRADE. 2. CONNECTIONS TO EXISTING GROUNDING ELECTRODE CONDUCTORS SHALL BE CADWELD OR EQUIVALENT. GROUND ROD CONNECTION SCALE: NTS PROVIDE A PVC SLEEVE AND FILL WITH A SUITABLE PLASTIC EXPANDABLE COMPOUND WHERE CONDUIT PASSES THROUGH SLAB <o 0 °,<0 0 0 0 G 0 < o U 0 ° 0<0 - 0 0 CONDUIT. FOR TYPE REQUIRED, SEE SPECIFICATIONS o <o < 0 °-<0 0 0 p 0 < G O < 0 °,<0 - 0 0 NOTES: 1. ALL CONDUITS THROUGH CONCRETE FLOOR SLABS AND EQUIPMENT PADS SHALL BE INSTALLED IN ACCORDANCE WITH THIS DETAIL. INTERIOR FLOOR SLAB PENETRATIO SCALE: NTS MANUFACTURE NAMEPLAT MIN 4 3/4" DIA ANCHOR; NOTES: >HA/NEC ACARD WIPMENT PAD 1. SUBMIT FINAL DESIGN AND CALCULATIONS FOR SUPPORT AND ANCHORAGE AS SPECIFIED. TRANSFORMER MOUNTING SCALE: NTS GALVANIZED STEEL SHEET METAL ESCUTCHEON,TYP GALVANIZED STEEL PIPE SLEEVE OR CORE DRILLED HOLE IN CONCRETE WALL 0 0 .0 0 0 o0 p>�o p 0 0 •p o o < po '_o• .. .5 O• �. INSULATION AS REQUIRED TO FILL CAVITY CONDUIT ow �z 0 u0w z� ?� OCQ 0— U- J O� NOTES: 1. CONDUITS WHICH INDIVIDUALLY PASS THRU AN INTERIOR WALL SHALL BE INSTALLED IN ACCORDANCE WITH THIS DETAIL. IF WALL IS A FIRE WALL, FILL CAVITY WITH FIRE STOP SEALANT AS SPECIFIED. INTERIOR WALL PENETRATION SCALE: NTS SIZE OPENINGS AS REQUIRED BY TRANSFORMER OR SWITCH MANUFACTURER 4'-0" PIGTAIL, TYP GROUND ROD, TYP GROUND CONDUCTOR, TYP EQUIPMENT PAD, TYPE XXX i oOl � 1 1'-0" M I N 4'-0" M I N z 0 GROUNDING LOOP AS SHOWN ON PLANS, TYP PLAN TRANSFORMER OR SWITCH FOOTPRINT CONDUITS AS REQUIRED, TYP NOTES: 1. COORDINATE ALL FINAL PAD DIMENSIONS WITH THE ELECTRICAL UTILITY OR MANUFACTURER'S APPROVED SHOP DRAWINGS. 2. SUBMIT FINAL DESIGN AND CALCULATIONS FOR SUPPORT AND ANCHORAGE AS SPECIFIED. TRANSFORMER OR SWITCH PAD SCALE: NTS R-4332478 DEVELOPMENT ENGINEERING U msippo 11 /25/2025 DESIGNED BY: SCALE: DRAWING NO.: D. TAFTFARREN DAFT F STRIDE BUS RAPID TRANSIT w NT BT120-EPD105 DRAWN BY: o i FILENAME: SOUTH RENTON TRANSIT CENTER I. KARNAS z� w -j S1-BT120-E-v2020 BT105 FACILITY ID: .Jaco s. J CHECKED BY: A 57079 BRT General Engineering Consultant z-- U-SOUNDTRANSIT CONTRACT No.: ELECTRICAL BT120 1 06/13/2025 EH DA DT ADDENDUM #1 D. ANDERSON �o� R�GISTEy- �wwRTA/CN 0205-24 SHEET No: REV: 0 12/10/2024 EH DA DT ISSUED FORBID APPROVED BY: �SSIONAL E:SUBMITTED BY: DATE: REVIEWED BY: DATE: SUBMITTAL DATE: DETAILS No. DATE DSN CHK APP REVISION D. TAFTFARREN 6113125 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 SOUTH RENTON TRANSIT CENTER 556 1