Loading...
HomeMy WebLinkAboutR-4332487N C'7 0 LU 0 N 0 N IiI 0 N m U) w C� I z ry I 0 a ry I D m 0 I 0 co 00 LO co a CI c� ti U) o � L o (N o cy) N co — co m UTILITY CUSTOMER M PSE UTILITY METER KCM SERVICE BT120-T-100 p PSE - ST _Ly PAD MOUNTED TRANSFORMER SIZE TO BE DETERMINED BY PSE PROVIDE SECONDARY FEEDER SIZE, QUANTITY AND WIRING METHOD AS REQUIRED PER PSE 600/3 " MAIN BREAKER 2" CONDUIT STUBBED TO ROOF AND CAPPED FOR SOLAR READINESS M )� PSE UTILITY METER ST SERVICE DPM b 125/3) 400/3) 43 ) Q BT120-SWGR-01, 480/277V, 3PH, 600A, 65kAIC Q o 60/3 v) 70/3 v) 400/3) 200/3 ) N G 3/0 C U 11 8 GEC FSPD 3 p 75kVAKCM-T-02 75kVA YrTSTEP 480V - 208Y/120V DOWN TRANSFORMER U KCM PANEL KCM-PB2-02 208/120V 3P4W 100/2) 100/3) 200A BUS Q Q 200A MCB 22KAIC 13 KCM-PB2-04 KCM 208/120V 3P 4W TELECOMM 100A BUS PANEL 10KAIC KCM-MBP-01 n T_100/�27 8KW UPS TELE KCM-UPS-1 208/120V 2P 3W SCALABE UP TO 16KW C130 T-02 p 45kVA5kVA, 3PH 480V - 208Y/120V -Ey STEP DOWN T5TRANSFORMER EV PANEL BT120-PB2-06 208V/120V 3P4W 125A MCB 22KAIC BT120-PB4-01 480/277V 3P4W 100A 22KAIC 13 KCM PLATFOR M PANEL KCM-PB2-03 208/120V 2P3W 100A BUS 90A MCB 10KAIC ELECTRICAL BT120-LCP-01 ROOM LIGHTING CONTROLLER 1 06/13/2025 EH DA DT ADDENDUM #1 0 12/10/2024 EH DA DT ISSUED FOR BID No. DATE DSN CHK APP REVISION BT120-ATS-01 480/277V 3PH 400A 4-POLE zkm� 11 BT120-SWBD-01, 480/277V, 3PH, 400A, 65kAIC 100/3) 250/3 ) T 9 BT120-T-01 SITE p 150kVA, 3PH LIGHTING & 480V - 208Y/120V PERMANENT STEP DOWN LOAD PANEL TRANSFORMER ( 00 BT1 20-SWBD-02. 208/12OV. 3PH. 400A. 65kAIC 100/3 ) m SECURITY PANEL BT120-PB2-01 208/120V 3P4W 100A 22KAIC DESIGNED BY: D. TAFTFARREN DRAWN BY: E. HAJAS CHECKED BY: D.ANDERSON APPROVED BY: D. TAFTFARREN 400/3 ) KEY NOTES: 130 480V LIGHTING CIRCUITS TO INDIVIDUALLY FEED THROUGH SEPARATE LIGHTING CONTROLLER CONTACTORS. 131 120V LIGHTING CIRCUITS TO INDIVIDUALLY FEED THROUGH SEPARATE LIGHTING CONTROLLER CONTACTORS. 1 200/3) 175/3 7 BT120-GEN-01 30OKW/375KVA 3PH, 480/277V STANDBY GENERATOR G _ 3/0 CU GEC 400/3) 200/3 (111 ST PANEL BT120-PB2-03 208/120V 3P4W 100/3) 200A 0 22KAIC BT120-PB2-05 ST 208/120V 3P 4W TELECOMM 100A BUS PANEL 10KAIC I I 20KW 6 UPS TELE BT120-UPS-01 208/120V 3P 4W SCALABE UP TO 40KW L— — — — — — — — pacobs �57079 R�GISTEY- ww �sSIONAL E��� SUBMITTED BY: DATE: 6113125 R. PARGAS 12/10/2024 FEEDER SCHEDULE ID FEEDER AMPS CONDUIT AND FEEDER FEEDING THESE DEVICES 1O 20 1 /2"C,3#12,#12G FACP O2 60 1 "C,3#4,#4N,#10G LCP, BT120-PB2-04 O3 100 1-1 /4"C,3#1,#8G BT120-T-02 O4 100 1-1 /2"C,3#1,#1 N,#8G O5 125 2"C,3#1/0,#1/ON,#6G BT120-PB2-05, BT120-PB2-06, KCM-T-022-04, KCM-PB2-04 O6 175 2"C,3#2/0,#2/ON,#6G BT120-MBP-01, BT120-PB2-02 O7 200 2"C,3#3/0,#3/ON,#6G BT120-PB2-03 O8 200 2-1/2"C WITH PULLSTRING FUTURE BT120-SWBD-03, FUTURE BT120-ATS-02 O9 250 2"C,3#250kcmil,#4G BT120-T-01 10 400 (2)2-1/2"C,3#3/0,#3/0N,#1/0G BT120-SWBD-02 11 400 (2)2-1/2"C,3#4/0,#4/ON,#2G BT120-ATS-01, BT120-SWBD-01 12 200 2"C,3#3/0,#3/ON,#4G KCM-PB2-02 13 100 1-1 /2"C,2#1,#1 N,#8G KCM-PB2-03, KCM-MBP-01 14 125 2"C, 3#1 /0, #6G KCM-T-02 SOME FEEDERS SIZES INCREASED FOR VOLTAGE DROP MITIGATION. CONTRACTOR RESPONSIBLE TO ENSURE WIRE BENDING SPACE AND TERMINATIONS ARE ADEQUATE ST UPS 90/3 ) 90/3 PANEL 100/3 BT120-PB2-02 4 208/120V 3P4W 22KAIC S BT120-PB2-04 ST 208/120V 3P4W M z PLATFORM 100A BUS PANEL 100A MCB BT120-EL-1 BT120-EL-2 10KAIC 480V 3PH 480V 3PH 131 40HP 40HP 4STmRIDE BRT General Engineering Consultant REVIEWED BY: J. ALTCHECH BT120-LCP-02 PLATFORM LIGHTING CONTROLLER SCALE: Q w mrr NTS Q FILENAME: U)� w J S 1-BT120-E-v2020 z U_ SOUNDTRANSIT CONTRACT No.: RTA/CN 0205-24 DATE: SUBMITTAL DATE: 12/10/2024 12/10/2024 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 ELECTRICAL CORE FACILITES ONE -LINE NE 145TH ST TO 98TH AVE NE I I I I I I I I I I I I I I R-4332487 DEVELOPMENT ENGINEERING -r msippo 11 /25/2025 DRAWING NO.: BT120-EPS102 FACILITY ID: BT120 SHEET No: REV: 565 1