Loading...
HomeMy WebLinkAboutR-4332492N co co w 0 N 0 N Iil 0 N H m 0 W CD I H Z Q ry I- I 0 n ry I (n D m 0 I 0 co 00 LO co 0 a I Cn 0 L o N (0 o cy) N rn m PANELBOARD: BT120-SWGR-01 LOCATION: ELECTRICAL ROOM VOLTAGE: 480/277 INTERRUPTING RATING (kA SYMMETRICAL): 65 SUPPLY FROM: PSE XFMR BT120-T-100 BUS AMPS: 600 GROUND BUS: FULL MOUNTING: FLOOR 400 MCB LSI BT120 METER NEUTRAL BUS RATING: FULL ENCLOSURE: NEMA 1 125 MCB LSI KCM METER SUBFEED LUGS: N/A INTEGRAL SPD: YES NOTES LOAD DESCRIPTIONS FRAME TRIP POLES CKT NO A B C A B C CKT POLES TRIP FRAME DESCRIPTIONS LOAD NOTES TYPE AMPS AMPS TYPE SPD 100 30 3 1 0 VA 33000 VA 2 3 200 400 (FUTURE GARAGE) BT120-SWBD-03 D - - - 3 0 VA 33000 VA 4 - - D - - - 5 0 VA 33000 VA 6 - - D D BT120-PB2-06 VIA BT120-T-02 100 100 3 7 6656 VA 8 3 - - - - - 400 SPACE D - - - 9 3328 VA 10 D - - - 11 3328 VA 12 D BT120-SWBD-01 VIA BT120-ATS-01 400 400 3 13 44229 VA 14 3 - 200 SPACE D - - - 15 39949 VA 16 - - D - - - 17 39037 VA 18 - - C 19 20 C 21 22 C 23 24 D KCM-P132-02 VIA KCM-T-02 200 125 3 25 14818 VA 26 3 - 200 SPACE FOR SOLAR REDINESS D - - - 27 10772 VA 28 - - D - - - 29 7067 VA 30 - - TOTAL CONNECTED LOAD / PHASE: 98703 VA 87049 VA 82432 VA LOAD CLASSIFICATIONS CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND TOTAL LOAD SUMMARY RECEPTACLE 0.00 50%>10K 0 LOAD (kVA) CURRENT (AMPS) LIGHTING 0.00 125% 0 VA CONNECTED LOAD: 268183 VA CONNECTED CURRENT: 323 CONTINUOUS 0.00 125% 0 VA ESTIMATED DEMAND LOAD: 268183 ESTIMATED DEMAND CURRENT: 323 NON -CONTINUOUS, HVAC, CYCLING 0.00 100% 0 VA ESTIMATED DEMAND FACTOR: 1 LARGEST MOTOR 0.00 125% 0 VA SPARE CAPACITY: NON -COINCIDENTAL 0.00 0% 0 VA DIVERSIFIED (MIXED LOADS PER NEC INCLUDED ABOVE) 268183.00 100% 268183 VA ESTIMATED CURRENT WITH SPARE: ESTIMATED LOAD WITH SPARE: PANELBOARD NOTES: SPD BREAKER SIZED PER MANUFACTURER'S RECOMMENDATION. PANELBOARD: BT120-PB2-06 LOCATION: ELECTRICAL ROOM VOLTAGE: 208/120 INTERRUPTING RATING (kA SYMMETRICAL): 10 SUPPLY FROM: BT120-SWGR-01 VIA BT120-T-02 BUS AMPS: 150 GROUND BUS: FULL MOUNTING: SURFACE 125 MCB NEUTRAL BUS RATING: FULL ENCLOSURE: NEMA 1 SUBFEED LUGS: N/A INTEGRAL SPD: NO NOTES LOAD TYPE DESCRIPTIONS FRAME TRIP AMPS POLES CKT NO A B C A B C CKT POLES TRIP AMPS FRAME DESCRIPTIONS LOAD TYPE NOTES C EV 40 2 1 3328 VA 2 2 40 SPARE C C - EV - 40 - 2 - 3 3328 VA 4 - - 2 40 - - 5 3328 VA 6 SPARE C - - 7 3328 VA 8 - SPARE 40 2 9 10 2 40 SPARE - - - 11 12 - - 40 - SPARE 40 2 13 14 2 SPARE - - - 15 16 - - - 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 TOTAL CONNECTED LOAD / PHASE: 6656 VA 42 3328 VA 3328 VA LOAD CLASSIFICATIONS CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND TOTAL LOAD SUMMARY RECEPTACLE 0.00 50%>10K 0 LOAD (kVA) CURRENT (AMPS) LIGHTING 0.00 125% 0 VA CONNECTED LOAD: 13312 VA CONNECTED CURRENT: 37 CONTINUOUS 13312.00 125% 16640 VA ESTIMATED DEMAND LOAD: 16640 ESTIMATED DEMAND CURRENT: 46 NON -CONTINUOUS, HVAC, CYCLING 0.00 100% 0 VA ESTIMATED DEMAND FACTOR: 1.25 LARGEST MOTOR 0.00 125% 0 VA SPARE CAPACITY: NON -COINCIDENTAL 0.00 0% 0 VA DIVERSIFIED (MIXED LOADS PER NEC INCLUDED ABOVE) 0.00 100% 0 VA ESTIMATED CURRENT WITH SPARE: ESTIMATED LOAD WITH SPARE: PANELBOARD NOTES: 0 1 12/10/2024 1 EH I DA I DT I ISSUED FORBID No. I DATE I DSN I CHK I APP I REVISION DESIGNED BY: D. TAFTFARREN DRAWN BY: E. HAJAS CHECKED BY: D.ANDERSON APPROVED BY: D. TAFTFARREN ; .acobs SUBMITTED BY: U1/L4/15 R. PARGAS 4hfTmRIDE BRT General Engineering Consultant DATE: REVIEWED BY: 12/10/2024 J. ALTCHECH QUJ J Q U)co W J J SOUNDTRANSIT DATE: 12/10/2024 SCALE: NTS FILENAME: S 1-BT120-E-v2020 CONTRACT No.: RTA/CN 0205-24 SUBMITTAL DATE: 12/10/2024 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 ELECTRICAL ST PANEL SCHEDULES SOUTH RENTON TRANSIT CENTER R-4332492 DEVELOPMENT ENGINEERING msippo 11 /25/2025 Ul DRAWING NO.: BT120-EPS112 FACILITY ID: BT120 SHEET No: REV: 570 0