PANELBOARD: BT120-SWGR-01
LOCATION: ELECTRICAL ROOM VOLTAGE: 480/277 INTERRUPTING RATING (kA SYMMETRICAL): 65
SUPPLY FROM: PSE XFMR BT120-T-100 BUS AMPS: 600 GROUND BUS: FULL
MOUNTING: FLOOR 400 MCB LSI BT120 METER NEUTRAL BUS RATING: FULL
ENCLOSURE: NEMA 1 125 MCB LSI KCM METER SUBFEED LUGS: N/A
INTEGRAL SPD: YES
NOTES LOAD DESCRIPTIONS FRAME TRIP POLES CKT NO A B C A B C CKT POLES TRIP FRAME DESCRIPTIONS LOAD NOTES
TYPE AMPS AMPS TYPE
SPD 100 30 3 1 0 VA 33000 VA 2 3 200 400 (FUTURE GARAGE) BT120-SWBD-03 D
- - - 3 0 VA 33000 VA 4 - - D
-
-
- 5
0 VA
33000 VA
6
- -
D
D
BT120-PB2-06 VIA BT120-T-02
100
100
3
7
6656 VA
8
3 -
- -
- -
400
SPACE
D
-
-
-
9
3328 VA
10
D
-
-
-
11
3328 VA
12
D
BT120-SWBD-01 VIA BT120-ATS-01
400
400
3
13
44229 VA
14
3
-
200
SPACE
D
-
-
-
15
39949 VA
16
-
-
D
-
-
-
17
39037 VA
18
-
-
C
19
20
C
21
22
C
23
24
D
KCM-P132-02 VIA KCM-T-02
200
125
3
25
14818 VA
26
3
-
200
SPACE FOR SOLAR REDINESS
D
-
-
-
27
10772 VA
28
-
-
D
-
-
-
29
7067 VA
30
-
-
TOTAL CONNECTED LOAD / PHASE:
98703 VA
87049 VA
82432 VA
LOAD CLASSIFICATIONS
CONNECTED LOAD
DEMAND FACTOR
ESTIMATED DEMAND
TOTAL LOAD SUMMARY
RECEPTACLE
0.00
50%>10K
0
LOAD (kVA)
CURRENT (AMPS)
LIGHTING
0.00
125%
0 VA
CONNECTED LOAD:
268183 VA
CONNECTED CURRENT:
323
CONTINUOUS
0.00
125%
0 VA
ESTIMATED DEMAND LOAD:
268183
ESTIMATED DEMAND CURRENT:
323
NON -CONTINUOUS, HVAC, CYCLING
0.00
100%
0 VA
ESTIMATED DEMAND FACTOR:
1
LARGEST MOTOR
0.00
125%
0 VA
SPARE CAPACITY:
NON -COINCIDENTAL
0.00
0%
0 VA
DIVERSIFIED (MIXED LOADS PER NEC INCLUDED ABOVE)
268183.00
100%
268183 VA
ESTIMATED CURRENT WITH SPARE:
ESTIMATED LOAD WITH SPARE:
PANELBOARD NOTES: SPD BREAKER SIZED PER MANUFACTURER'S RECOMMENDATION.
PANELBOARD: BT120-PB2-06
LOCATION: ELECTRICAL ROOM VOLTAGE: 208/120 INTERRUPTING RATING (kA SYMMETRICAL): 10
SUPPLY FROM: BT120-SWGR-01 VIA BT120-T-02 BUS AMPS: 150 GROUND BUS: FULL
MOUNTING: SURFACE 125 MCB NEUTRAL BUS RATING: FULL
ENCLOSURE: NEMA 1 SUBFEED LUGS: N/A
INTEGRAL SPD: NO
NOTES
LOAD
TYPE
DESCRIPTIONS
FRAME
TRIP
AMPS
POLES CKT NO
A
B
C
A
B
C
CKT
POLES TRIP
AMPS
FRAME
DESCRIPTIONS
LOAD
TYPE
NOTES
C
EV
40
2 1
3328 VA
2
2 40
SPARE
C
C
-
EV
-
40
-
2
-
3
3328 VA
4
- -
2 40
-
-
5
3328 VA
6
SPARE
C
-
-
7
3328 VA
8
-
SPARE
40
2
9
10
2
40
SPARE
-
-
-
11
12
-
-
40
-
SPARE
40
2
13
14
2
SPARE
-
-
-
15
16
-
-
-
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
TOTAL CONNECTED LOAD / PHASE:
6656 VA
42
3328 VA
3328 VA
LOAD CLASSIFICATIONS
CONNECTED LOAD
DEMAND FACTOR
ESTIMATED DEMAND
TOTAL LOAD SUMMARY
RECEPTACLE
0.00
50%>10K
0
LOAD (kVA)
CURRENT (AMPS)
LIGHTING
0.00
125%
0 VA
CONNECTED LOAD:
13312 VA
CONNECTED CURRENT:
37
CONTINUOUS
13312.00
125%
16640 VA
ESTIMATED DEMAND LOAD:
16640
ESTIMATED DEMAND CURRENT:
46
NON -CONTINUOUS, HVAC, CYCLING
0.00
100%
0 VA
ESTIMATED DEMAND FACTOR:
1.25
LARGEST MOTOR
0.00
125%
0 VA
SPARE CAPACITY:
NON -COINCIDENTAL
0.00
0%
0 VA
DIVERSIFIED (MIXED LOADS PER NEC INCLUDED ABOVE)
0.00
100%
0 VA
ESTIMATED CURRENT WITH SPARE:
ESTIMATED LOAD WITH SPARE:
PANELBOARD NOTES:
0 1 12/10/2024 1 EH I DA I DT I ISSUED FORBID
No. I DATE I DSN I CHK I APP I REVISION
DESIGNED BY:
D. TAFTFARREN
DRAWN BY:
E. HAJAS
CHECKED BY:
D.ANDERSON
APPROVED BY:
D. TAFTFARREN
; .acobs
SUBMITTED BY:
U1/L4/15 R. PARGAS
4hfTmRIDE
BRT General Engineering Consultant
DATE: REVIEWED BY:
12/10/2024 J. ALTCHECH
QUJ
J
Q
U)co
W J
J
SOUNDTRANSIT
DATE:
12/10/2024
SCALE:
NTS
FILENAME:
S 1-BT120-E-v2020
CONTRACT No.:
RTA/CN 0205-24
SUBMITTAL DATE:
12/10/2024
STRIDE BUS RAPID TRANSIT
SOUTH RENTON TRANSIT CENTER
BT105
ELECTRICAL
ST PANEL SCHEDULES
SOUTH RENTON TRANSIT CENTER
R-4332492
DEVELOPMENT ENGINEERING
msippo 11 /25/2025 Ul
DRAWING NO.:
BT120-EPS112
FACILITY ID:
BT120
SHEET No: REV:
570 0