Loading...
HomeMy WebLinkAboutR-4332504N co co 6 W 0 N 0 N W O N H m V1 U W C� I H V) Z Q ry H I c) W ry I D m 0 I 0 co 00 LO co W CI N j �n ti U) o � Lo (N o cy) N co �_ co m EQUIPMENT MATRIX ELECTRICAL BT105 - 3 REMOTELY EQUIPMENT EQUIPMENT ID EQUIPMENT UPS ROOM NO. NAME DISCIPLINE REQUIREMENT MONITORED REMOTELY BMS MONITORED — D DIAGRAM CIRCULATION EQUIPMENT N�EQUIPMENT DESCRIPTION DIMENSIONS (L x EQUIPMENT WEIGHT EQUIPMENT (Ibs)REMARKS BT120-DISC-01 01 BT120L1207 COMFORT STATION 4 ELECTRICAL No No No No No No No DISCONNECT DISCONNECT 5"x7"x15" 9 BT120-DISC-02 02 BT120L1206 COMFORT STATION 3 ELECTRICAL No 5"x7"x15" 9 BT120-DISC-03 03 BT120L1205 COMFORT STATION 2 ELECTRICAL No No No No DISCONNECT 5"x7"x15" 9 BT120-DISC-04 04 BT120L1205 COMFORT STATION 2 ELECTRICAL No No No No DISCONNECT 5"x7"x15" 9 BT120-DISC-05 05 BT120L1204 COMFORT STATION 1 ELECTRICAL No No No No DISCONNECT DISCONNECT 5"x7"x15" 9 BT120-DISC-06 06 BT120L1203 JANITOR ELECTRICAL No No No No 5"x7"x15" 5"x7"x15" 7"x9"x22" 9 BT120-DISC-07 BT120-DISC-08 07 BT120L1201 BT120L1203 SEC STORAGE JANITOR ELECTRICAL ELECTRICAL No No No No DISCONNECT DISCONNECT 9 08 No No No No 120 BT120-DISC-09 09 BT120L1200 SECURITY BLDG ELECTRICAL No No No No DISCONNECT 4"x2"x4" 1 BT120-DISC-10 10 BT120L1200 SECURITY BLDG ELECTRICAL No No No No DISCONNECT 4"x2"x4" 1 BT120-HHLV-12 12 - SITE ELECTRICAL No No No No HANDHOLE 36"x24"x24" 2275 BT120-HHLV-13 13 - SITE ELECTRICAL No No No No HANDHOLE 36"x24"x24" 2275 BT120-HHLV-14 14 - SITE ELECTRICAL No No No No HANDHOLE 36"x24"x24" 2275 BT120-HHLV-15 15 - SITE ELECTRICAL No No No No HANDHOLE 22.5"x33"x18.5" 196 BT120-HHLV-16 16 - SITE ELECTRICAL No No No No HANDHOLE 22.5"x33"x18.5" 196 BT120-HHLV-17 17 - SITE ELECTRICAL No No No No HANDHOLE 22.5"x33"x18.5" 196 BT120-HHLV-18 18 - SITE ELECTRICAL No No No No HANDHOLE 22.5"x33"x18.5" 196 BT120-HHLV-19 19 - SITE ELECTRICAL No No No No HANDHOLE 22.5"x33"x18.5" 196 BT120-HHLV-20 20 - SITE ELECTRICAL No No No No HANDHOLE 22.5"x33"x18.5" 196 BT120-HHLV-21 21 - SITE ELECTRICAL No No No No HANDHOLE 22.5"x33"x18.5" 196 BT120-HHLV-22 22 - SITE ELECTRICAL No No No No HANDHOLE 22.5"x33"x18.5" 196 BT120-HHLV-23 23 - SITE ELECTRICAL No No No No HANDHOLE 22.5"x33"x18.5" 196 BT120-HHLV-26 26 - SITE ELECTRICAL No No No No HANDHOLE 36"x24"x24" 2275 BT120-HHLV-27 27 - SITE ELECTRICAL No No No No HANDHOLE 36"x24"x24" 2275 BT120-HHLV-28 28 - SITE ELECTRICAL No No No No HANDHOLE 36"x24"x24" 2275 BT120-HHLV-29 29 - SITE ELECTRICAL No No No No HANDHOLE 22.5"x33"x18.5" 196 BT120-HHLV-30 30 - SITE ELECTRICAL No No No No HANDHOLE 22.5"x33"x18.5" 196 BT120-HHLV-31 31 - SITE ELECTRICAL No No No No HANDHOLE 22.5"x33"x18.5" 196 BT120-HHLV-32 32 - SITE ELECTRICAL No No No No HANDHOLE 22.5"x33"x18.5" 196 BT120-HHSC-25 25 - SITE ELECTRICAL No No No No HANDHOLE 36"x24"x24" 2275 BT120-PB2-01 01 BT120L1200 SECURITY ELECTRICAL No No No Yes PANELBOARD 20"x5.75"x32" 70 BT120-PB2-02 02 BT120L1209 ELECTRICAL ELECTRICAL No No No Yes PANELBOARD 20"x5.75"x38" 70 BT120-PB2-03 03 BT120L1209 ELECTRICAL ELECTRICAL No No No Yes PANELBOARD 20"x5.75"x38" 70 BT120-PB2-04 04 - CANOPY ELECTRICAL Yes No No No PANELBOARD 16"x6.25"x36.25" 300 BT120-PB2-05 05 BT120L1208 TELECOM ELECTRICAL Yes No No No PANELBOARD 20"x5.75"x38" 70 BT120-PB2-06 06 BT120L1209 ELECTRICAL ELECTRICAL No No No Yes PANELBOARD 20"x5.75"x56" 70 BT120-PB4-01 01 BT120L1209 ELECTRICAL ELECTRICAL No No No Yes PANELBOARD 20"x5.75"x38" 70 BT120-SWBD-01 01 BT120L1209 ELECTRICAL ELECTRICAL No No No Yes SWITCHBOARD 42"x9.5"x59" 554 BT120-SWBD-02 02 BT120L1209 ELECTRICAL ELECTRICAL No No No Yes SWITCHBOARD 42"x9.5"x59" 554 BT120-SWGR-01 01 BT120L1209 ELECTRICAL ELECTRICAL No Yes No Yes SWITCHGEAR 72"x24"x91.5" 1565 BT120-T-01 01 BT120L1209 ELECTRICAL ELECTRICAL No No No Yes TRANSFORMER 33.65"x32.57"x40.58" 1207 BT120-T-02 02 BT120L1209 ELECTRICAL ELECTRICAL No No No Yes TRANSFORMER 26"x25.5"x30" 399 BT120-T-100 100 - EQUIPMENT YARD ELECTRICAL No No No No TRANSFORMER 84"x84"x35" 4802 BT120-T-100 100 - EQUIPMENT YARD ELECTRICAL No No No No TRANSFORMER 84"x84"x35" 4802 BT120-UPS-01 01 BT120L1209 ELECTRICAL ELECTRICAL Yes Yes No Yes UNINTERRUPTIBLE POWER SUPPLY 24"x36"X82" 1120 KCM-MBP-01 01 BT120L1209 ELECTRICAL ELECTRICAL Yes Yes No Yes MAINTENANCE BYPASS / ISOLATION SWITCH 17"x24"x7" 47 KCM-PB2-02 02 BT120L1209 ELECTRICAL ELECTRICAL No No No Yes PANELBOARD 20"x5.75"x38" 70 KCM-PB2-03 03 - CANOPY ELECTRICAL Yes No No No PANELBOARD 20"x5.75"x38" 70 KCM-PB2-04 04 BT120L1208 TELECOM ELECTRICAL No No No Yes PANELBOARD 20"x5.75"x38" 70 KCM-T-02 02 BT120L1209 ELECTRICAL ELECTRICAL No No No Yes TRANSFORMER 34"x37"x54" 515 KCM-UPS-01 01 BT120L1209 ELECTRICAL ELECTRICAL Yes Yes No Yes UNINTERRUPTIBLE POWER SUPPLY 19"x28.5"x33" 483 1 R-4332504 DEVELOPMENT ENGINEERING msippo 11 /25/2025 Ul DESIGNED BY: SCALE: DRAWING NO.: D. TAFTFARREN zAFTF w NTS STRIDE BUS RAPID TRANSIT DRAWN BY: ��� S o 7 ¢ U FILENAME: SOUTH RENTON TRANSIT CENTER BT120-EPS132 E. HAJASTw RIDE U) co BT105 FACILITY ID: .facobs 9 CHECKED BY: 0 57079 BRT General Engineering Consultant CONTRACT No.: BT120 SOUNDTRANSIT ELECTRICAL 1 06/13/2025 IK DA DT ADDENDUM #1 D. ANDERSON �o ��GISTER�ww RTA/CN 0205-24 SHEET No: REV: 0 12/10/2024 EH DA DT ISSUED FORBID APPROVED BY:SSIONAL ESUBMITTED BY: DATE: REVIEWED BY: DATE: SUBMITTAL DATE: EQUIPMENT MATRIX No. DATE DSN CHK APP REVISION D. TAFTFARREN 6/1 312 5 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 SOUTH RENTON TRANSIT CENTER 582 1