BT120-JCX212
1 2"C-BT1 20-SC-1 33
12'-0"
BT120-HH-105
U12"C-BT120-SC-134
70 BT120-VMS-04
(NIC)
3 BT120-SCR-03
(NIC)
n1 "C-BT120-SC-135
O1 "C-BT1 20-SC-1 36
2'-0„
CONDUIT AND WIRING SCHEDULE
CONDUIT TAG
EQUIPMENT
CONDUIT
SIZE
WIRE TYPE
REMARK
FROM
TO
BT120-SC-28
BT120-SC-29
BT120-HH-07
BT120-HH-07
BT120-HH-106
BT120-HH-106
2" PVC
2" PVC
2-12SMFO
ST
ST
BT120-SC-30
BT120-HH-08
BT120-HH-107
BT120-HH-108
2" PVC
2" PVC
2-12SMFO
KCM
BT120-SC-31
BT120-HH-08
KCM
BT120-SC-120
BT120-SC-121
BT120-DC-03
BT120-HH-108
BT120-HH-108
BT120-HH-109
2" PVC
2" PVC
3-CAT6
1-12SMFO
KCM
KCM
BT120-SC-122
BT120-SC-123
BT120-HH-108
BT120-HH-108
BT120-PBA-03
1" PVC
2" PVC
2-CAT6
KCM
KCM
BT120-HH-206
BT120-SC-125
BT120-DC-02
BT120-HH-107
BT120-HH-106
2" PVC
3" PVC
9-CAT6
ST
ST
BT120-SC-126
BT120-DC-02
1-12SMFO
BT120-SC-127
BT120-HH-106
BT120-HH-110
2" PVC
1-12SMFO
ST
BT120-SC-129
BT120-DC-02
BT120-SCR-04
1" PVC
1-CAT6
1-CAT6
ST
BT120-SC-130
BT120-HH-107
BT120-TVM-02
1" PVC
ST
BT120-SC-131
BT120-SC-132
BT120-HH-107
BT120-HH-207
2" PVC
2" PVC
4-CAT6
ST
ST
BT120-HH-107
BT120-HH-105
5-CAT6
BT120-SC-133
BT120-SC-134
BT120-HH-105
BT120-HH-105
BT120-HH-204
BT120-VMS-04
2" PVC
2" PVC
2-CAT6
2-CAT6
ST
ST
BT120-SC-135
BT120-HH-105
BT120-SCR-03
1" PVC
1-CAT6
ST
BT120-SC-136
BT120-HH-105
BT120-PBA-02
1" PVC
1-CAT6
ST
BT120-SC-155
BT120-SC-200
BT120-DC-03
BT120-DC-03
BT120-HH-108
BT120-HH-120
1" PVC
2" PVC
1-12SMFO
2-CAT6
KCM
KCM
BT120-SC-201
BTR120-HH-120
BT120-HH-109
2" PVC
2-CAT6
KCM
BT120-SC-222
BTR120-HH-105
BT120-HH-107
2" PVC
2" PVC
1-CAT6
ST
ST
BT120-SC-223
BTR120-DC-02
BT120-HH-107
2-CAT6
1
06/13/2025
JM
SW
MC
ADDENDUM #1
0
12/10/2024
JM
SW
MC
ISSUED FORBID
No.
DATE
DSN
CHK
APP
REVISION
DESIGNED BY:
J.MARGOLIS
DRAWN BY:
W.TURNER
CHECKED BY:
S.WHITE
APPROVED BY:
M.COX
24'-0"
A
BT120-JCE212
A
BAY 2 13T120-JCX212
BT120-CC-05 4 -
BT120-CC-06,
24'-0"
2"C-BT1 20-SC-1 23 !�
1 "C-BT120-SC-122 1 1
A
BT120-JCX212
i 77
12. .E
i`
BT120-DC-03 12
BT120-HH-108
10
�BT120-HH-120
10
i
BT1 0 CjR-04 3 5' - 11" I 1--7 1 - - 7' -
1 "C-BT120-SC-129 ' 1 = 4L-
BT120-PBA-02 O
(NIC)
2"C-BT120-SC-132�
10 2"C-BT120-SC-222
A
BT120-JCE211
2"C-BT120-SC-131 1
BT120-TVM-02 (NIC) 6
1 "C-BT120-SC-130 ( 1
MATCHLINE:
SEE DWG BT120-JCP201
BAY 8 `
10 BT120-HH-106
OAARCADIS
SUBMITTED BY:
06/10/2025 R. PARGAS
3'-3"
[::::2"C-BT120-SC-121 1
2"C-BT120-SC-201 1
0
0
N
0-
w
Z o
J r
2 H
t� m
Q �
W
W
U)
—----------------------------- 2"C-BT120-SC-120
----1 "C-BT1 20-SC-1 55 O
2"C-BT120-SC-200 10
BT120-DC-02 O
4STmRIDE
BRT General Engineering Consultant
DATE: REVIEWED BY:
12/10/2024 J. ALTCHECH
�BT120-HH-107 10
2"C-BT120-SC-127 1
2"C-BT120-SC-31 O
2"C-BT120-SC-30 O
2"C-BT120-SC-125 O
2"C-BT120-SC-223 O
3"C-BT120-SC-126 1
2"C-BT120-SC-28 0
2"C-BT120-SC-29 O
CONSTRUCTION NOTES:
1 i INSTALL ALL CONDUIT ABOVE FOUNDATION OF SHELTER, SEE STRUCTURAL PLAN DWG
BT120-SFP212 TO BT120-SFP215 FOR DETAILS. MAINTAIN A 2" MINIMUM CLEARANCE ABOVE
FOUNDATION.
2 INSTALL ST COMMUNICATIONS CABINET AND CABINET FOUNDATION.
SEE DETAIL ON DWG BT120-JCD208. SEE DWG BT120-SGY403 FOR STRUCTURAL DETAILS.
(3 STUB UP CONDUIT. WAYSIDE VALIDATOR/SMART CARD READER POST INSTALLED BY
OTHERS. SEE DETAIL ON DWG BT120-JCD206.
40 STUB UP CONDUIT INTO THE DESIGNATED CHANNEL ON THE COLUMN, WHICH VARIES
DEPENDING ON THE CONDUIT ROUTING RELATIVE TO THE CANOPY'S LOWER OR HIGHER
SIDE. ENSURE CONDUITS STUB UP AT CORRECT LOCATION AND SIDE. SEE DWG BT120-
JCX210 TO BT120-JCX212 AND BT120-AED903 FOR MORE DETAILS. SEE BT120-JCE209 TO
BT120-JCE216 FOR VERTICAL CONTINUATION.
OSTUB UP CONDUIT INTO CABINET FOUNDATION. SEE DETAIL ON DWG BT120-JCD207.
6 STUB UP CONDUIT. TVM INSTALLED BY OTHERS. SEE DETAIL ON DWG BT120-JCD206.
7 STUB UP CONDUIT. PYLON VMS INSTALLED BY OTHERS. SEE DETAIL ON DWG BT120-
JCD206.
8 STUB UP CONDUIT INTO PBA POLE. PBA INSTALLED BY OTHERS. SEE DETAIL ON DWG
BT120-JCD204.
1100; INSTALL TYPE 2 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.10-04
WITH DECORATIVE LID. STUB UP CONDUIT TO JUNCTION BOX.
DIMENSION ON PLAN IS TO THE CENTERLINE OF THE BOX. BOX WILL BE
LOCATED CENTERED ON THE LID. SEE DETAIL ON DWG BT120-JCD207
FOR CONDUIT ROUTING DETAILS.
12 INSTALL KCM COMMUNICATIONS CABINET AND CABINET FOUNDATION.
SEE DETAIL ON DWG BT120-JCD208.SEE DWG BT120-SGY403 FOR STRUCTURAL DETAILS.
SCALE:
Q
w
As indicated
Q
FILENAME:
Cn
w
C/)
S1-BT120-J-CAN-v2020
Z
J
J
U-
SOUNDTRANSIT
CONTRACT No.:
RTA/CN 0205-24
DATE:
SUBMITTAL DATE:
12/10/2024
12/10/2024
L C D
PLATFORM
E
F
G
H
CORE 1 8 4 0 8 16
FACILITY GEN
KEY PLAN SCALE IN FEET
DEVELOPMENT ENGINEERING
msippo 11 /25/2025%Jj R-4332509
STRIDE BUS RAPID TRANSIT DRAWING NO.:
SOUTH RENTON TRANSIT CENTER BT120-JCP207
BT105 FACILITY ID:
SYSTEMS BT120
SHEET No: REV:
STRIDE BAY 2 AND 8 COMMUNICATIONS PLAN
587 1