SECURITY GENERAL NOTES
A. THE LOCAL GENERAL CONTRACTOR (GC) IS RESPONSIBLE FOR CONDUIT RACEWAYS, BACK
BOXES AND TO PROVIDE AND INSTALL NECESSARY DOOR LOCKING HARDWARE (ELECTRICAL
OR OTHER) ELECTRICAL LOCKING HARDWARE TO BE INSTALLED TO THE INSIDE JAMB AND
TESTED PRIOR TO SECURITY CONTRACTORS ARRIVAL. ON SITE, SECURITY CONTRACTOR (SC)
TO PROVIDE IP CAMERA SYSTEMS, REX DEVICES, CARD READERS. AND INSTALLATION
LABOR, INCLUDING FINAL CONNECTIONS. PROGRAMMING AND TESTING.
B. SECURITY CABLING SHALL BE COMPLETED BY THE SECURITY CONTRACTOR DESIGNATED
VENDOR. THE CABLE SHALL BE INSTALLED FROM THE SECURITY CONTROL PANEL TO THE
DOOR THAT IT SERVICES. THERE SHALL BE APPROPRIATE SERVICE LOOP AT EACH END TO
REACH THE FIELD DEVICES, THE CONDUIT REQUIREMENTS ARE LISTED BELOW FOR VARIOUS
DOOR TYPES.
C. THE NETWORK CABLE FOR THE VIDEO CAMERAS IS TO BE TERMINATED AND TESTED PRIOR
TO THE INSTALLATION OF THE CAMERAS. THE HORIZONTAL CABLING SHALL BE TERMINATED
AT THE TELECOM ROOM TO THE PATCH PANEL AND LABELED.
D. THE FIELD END SHALL TERMINATE ON A 8P8C RJ45 OUTLET MOUNTED IN A SINGLE GANG
SURFACE MOUNT BLOCK AND BE LABELED IN THE SAME MANNER AS THE PATCH PANEL. A 10,
PATCH CORD SHALL BE INSTALLED BY SECURITY CONTRACTOR, AND CONNECTED TO THE
NETWORK OUTLET PROVIDED, TO ALLOW FOR THE EXACT PLACEMENT OF THE CAMERA
DEVICES.
E. DOOR HARDWARE AND WIRING TO THE HINGES IS THE RESPONSIBILITY OF THE GENERAL
CONTRACTOR. SECURITY CONTRACTOR SHALL MAKE THE INTERCONNECTIONS OF THE
GENERAL CONTRACTOR PROVIDED LOCKING HARDWARE TO THE ACCESS CONTROL SYSTEM.
F. ACCESS CONTROL SYSTEM & EQUIPMENT SHALL BE INSTALLED, UTILIZING OWNER IT
NETWORK INFRASTRUCTURE STANDARDS, THE ACCESS CONTROL SYSTEMS SHALL BE
INSTALLED IN THE TELECOM ROOM ON A PLYWOOD SHEET UTILIZING A CHASE FOR WIRE
MANAGEMENT PER DRAWINGS, THE IP INFORMATION IS TO BE PROVIDED TO THE SECURITY
CONTRACTOR BY OWNER.
G. VIDEO CAMERAS SHALL BE CONNECTED TO RACK MOUNTED NETWORK SWITCHES IN THE
TELECOM ROOM AND PROVIDED BY THE SECURITY CONTRACTOR, NETWORK SWITCHES
SHALL BE CONNECTED TO THE VIDEO SURVEILLANCE SYSTEM NETWORK VIDEO SERVER IN
THE TELECOMMUNICATIONS ROOM. VIDEO SURVEILLANCE SYSTEM SERVER SHALL BE
CONNECTED TO THE OWNER IT NETWORK.
H. CONDUIT FOR DOOR CONTACT DEVICES SHALL BE 1" EMT CONDUIT.
I. CONDUIT FOR POWER TRANSFER HINGE SHALL BE 1" EMT CONDUIT.
J. CONDUIT FOR SECURITY CAMERA SHALL BE 1" EMT CONDUIT.
K. THE SYSTEM SHALL UTILIZE CARD READERS, BADGES SHALL BE COORDINATED WITH THE
SITE OWNER BY SECURITY CONTRACTOR. ALL ACCESS CONTROL SYSTEM CABLES TO BE
PLENUM RATED.
L. DOOR DETAILS ARE TYPICAL FOR CONDUIT AND BACK BOX EMT REQUIREMENTS. REFER TO
FLOOR PLANS FOR ACTUAL DEVICE LOCATION AT EACH DOOR.
M. ALL JUNCTION BOXES SHALL BE MOUNTED ON THE PROTECTED SIDE OF THE DOOR.
N. WHERE NO FINISHED CEILING EXISTS, JUNCTION BOXES OVER DOORS SHALL BE PLACED AT
LEAST NINE INCHES FROM BOTTOM OF BOX TO TOP OF DOOR AS SPACE PERMITS, BOX
COVER TO BE ACCESSIBLE, COORDINATE LOCATION WITH OTHER TRADES.
O. RECESSED CONTACTS SHALL BE INSTALLED WITHIN SIX INCHES FROM LATCH SIDE OF DOOR.
HANDBOX SHALL BE CENTERED ON CONTACT LOCATION. WIRING FOR DEVICES ON DOUBLE
DOORS SHALL BE RUN THROUGH HOLLOW METAL FRAMES.
P. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL NECESSARY DOOR LOCKING
HARDWARE WHICH IS TO BE INSTALLED TO THE INSIDE JAMB AND TESTED PRIOR TO THE
SECURITY CONTRACTOR ARRIVAL. SECURITY CONTRACTOR TO COORDINATE AS REQUIRED.
Q. FOR INSTALLATION OF ELECTROMAGNETIC LOCKS, ELECTRIFIED MORTISE LOCKS AND
ELECTRICAL STRIKES, FOLLOW MANUFACTURER'S INSTRUCTIONS.
0 1 12/10/2024 1 DS I MF I DTF I ISSUED FOR BID
No. I DATE I DSN I CHK I APP I REVISION
DESIGNED BY:
D. STOLTZ
DRAWN BY:
M. SANTO
CHECKED BY:
M.FREEMAN
APPROVED BY:
D. TAFT-FARREN
SECURITY GENERAL NOTES CONT.
R. SECURITY DEVICES SHALL BE MOUNTED ON BACKBOXES, AS SHOWN IN INSTALLATION
DETAILS. UNLESS OTHERWISE NOTED, CONDUITS, PULL STRINGS, BACKBOXES AND
BUSHINGS SHALL BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR.
S. SECURITY CONTRACTOR SHALL COORDINATE FINAL QUANTITIES, LOCATIONS AND STYLES
WITH ELECTRICAL CONTRACTOR AND ARCHITECT.
T. PANEL COUNTS AND CONNECTIONS ARE FOR REFERENCE ONLY. CONFIRM ALL COUNTS AND
PANEL LAYOUT BASED ON DEVICE COUNTS.
U. ALL FIBER IS PROVIDED BY TELECOM CONTRACTOR.
V. SECURITY CABLING SHALL BE COMPLETED BY THE SECURITY CONTRACTOR UNLESS
OTHERWISE NOTED, CABLE SHALL BE INSTALLED FROM THE TELECOM ROOM TO THE DOOR
THAT IT SERVICES WITH AN APPROPRIATE SERVICE LOOP AT EACH END TO REACH FIELD
DEVICES.
W. NETWORK CABLE FOR VIDEO CAMERAS SHALL BE PROVIDED BY THE TELECOM CONTRACTOR
AND IS TO BE TERMINATED AND TESTED PRIOR TO THE INSTALLATION OF CAMERAS,
HORIZONTAL CABLING SHALL BE TERMINATED AT THE TELECOM ROOM TO THE PATCH PANEL
AND LABELED AS 'CAM#' THAT CORRELATES TO THE CAMERA NUMBER IDENTIFIED ON THE
SECURITY DRAWINGS.
X. THE FIELD END OF NETWORK CABLE FOR VIDEO CAMERAS SHALL TERMINATE TO A SURFACE
MOUNTED BOX AND LABELED IN THE SAME MANNER AS THE PATCH PANEL. A 10, PATCH CORD
SHALL BE INSTALLED IN THE OUTLET TO ALLOW EXACT PLACEMENT OF THE CAMERAS.
Y. SECURITY SYSTEMS AND EQUIPMENT SHALL BE INSTALLED UTILIZING OWNER IT NETWORK
INFRASTRUCTURE STANDARDS. IP INFORMATION IS TO BE PROVIDED TO THE SECURITY
CONTRACTOR BY THE OWNER AND/OR THE IT STAFF.
Z. VIDEO CAMERAS SHALL BE CONNECTED TO SECURITY CONTRACTOR PROVIDED RACK
MOUNTED NETWORK SWITCHES IN TELECOM ROOMS. NETWORK SWITCHES SHALL BE
CONNECTED TO THE VIDEO SURVEILLANCE SYSTEM SERVER IN THE MDF, VIDEO
SURVEILLANCE SYSTEM SERVER SHALL BE CONNECTED TO THE OWNER IT NETWORK.
.;acobs
SUBMITTED BY:
12102124 R. PARGAS
4ST)?IDE
BRT General Engineering Consultant
DATE: REVIEWED BY:
09/06/2024 J. ALTCHECH
Q w
U)cn
w J
Z J
SOUNDTRANSIT
DATE:
12/04/2024
SCALE:
N.T.S.
FILENAME:
S1-BT120-J-BLD-v2020
CONTRACT No.:
RTA/CN 0205-24
SUBMITTAL DATE:
09/06/2024
STRIDE BUS RAPID TRANSIT
SOUTH RENTON TRANSIT CENTER
BT105
TELECOM
GENERAL NOTES
TRANSIT CENTER
R-4332544
DEVELOPMENT ENGINEERING
msippo 11 /25/2025 Ul
DRAWING NO.:
BT120-JCN005
FACILITY ID:
BT120
SHEET No: REV:
622 0