rCORE-
FACILITY -ROOF
41' - 2" I -I -[V1
M IV
CORE FACILITY
28'-211 O
I8
BT120-FFP-01=
I
I
I
I
I
I
I
I
I
I
I
I
i14
TYP.
15
TYP.
�20
�I
TYP.
1
I
j
BT0-CPP
aBT112200--CFPPPP--002 3
i BT120-ETH-02
I
I
I
I
I
CCTV
BT120-CR-01
I
I
RESERVED
FOR SECURITY
EQUIPMENT
I
I
I
I
I
NETWORK
BT120-CR-02
�
I
II
RESERVED
FOR OWNER
EQUIPMENT
i
SPARE
BT120-CR-03
I
RESERVED
FOR OWNER
EQUIPMENT
BT120-UPS-OS
BT120-UPS-02
BT120-UPS-03
ST TELECOM ROOM
RACK ELEVATION
SCALE: 1 /2" = 1'-0"
1 06/27/2025 DS MF DTF ADDENDUM #2
0 12/10/2024 DS MF DTF ISSUED FORBID
No. I DATE I DSN I CHK I APP I REVISION
TYP.
BT120-JCE262
DESIGNED BY:
D. STOLTZ
DRAWN BY:
M. SANTO
CHECKED BY:
M.FREEMAN
APPROVED BY:
D. TAFT-FARREN
CORE --�
FACILITY -ROOF
41'-2"
8 TYP.
1
1
4'-4" 3'-4" 3'-811
7 12
6 4 10 9 1
TYP. [('5� 2
TYP
N
11 BT120-SC-02
I I I I I I 14
I I I I
I I I I BT120-FPP-05
I I I I
I I I I 22 I I I I
1 I I I I
I I I I 0
I I I I 15 L.L i i i i BT120-CPP-04
Q Y 0
N
CV LJL-
LL��LLjj r I I I I I
I I I I I
TELECOM 60 0 o O 13
BT120L1208 0 N 01 01
I I I I i
I I I
LL
I I I
J i BT120-CR-08 i i BT120-CR-07 i i BT120-CR-06
O
I I I I I I
I I I
I I I
RESERVED FORT RESERVED FOR
SPARE KCM KCM
EQUIPMENT j EQUIPMENT
I I i I
I I I
16
I I I BT120-UPS-04
I I I I
ACIL11 r
O
CORE F
28' - 2'1
a.
(17 UNUSED.
KCM TELECOM ROOM
SOUTH RACK ELEVATION
SCALE: 1/2" = 1'-0"
.;acobs
SUBMITTED BY:
612 7/2 5 R. PARGAS
DATE:
12/10/2024
4STm)?IDE
BRT General Engineering Consultant
REVIEWED BY:
J. ALTCHECH
BT120-JCE262
Q w
U)�
W J
Z J
SOUNDTRANSIT
DATE:
12/10/2024
18 UNUSED.
19 UNUSED.
A
20 48-PORT 1 RU NETWORK SWITCH OFCI
21 SEE SECURITY DETAIL DRAWINGS FOR
SECURITY RACK ELEVATION.
22 PROVIDE 1 RU 19-INCH EIA HORIZONTAL CABLE
MANAGER, SINGLE SIDED WITH SNAP -ON
COVER THAT OPENS 180 DEGREES UP OR
DOWN.
TY
P.
SCALE:
AS NOTED
FILENAME:
S1-BT120-J-BLD-v2020
CONTRACT No.:
RTA/OA 0206-19
SUBMITTAL DATE:
12/10/2024
GENERAL NOTES:
A. CONTRACTOR SHALL BOND ALL LADDER TRAY,
CONDUITS, RACKS AS PER ANSI/TIA 607-D STANDARD
B. INSTALLATION OF ALL EQUIPMENT AND WIRING SHALL
MEET ALL APPLICABLE CODES AND STANDARDS
INCLUDING BUT NOT LIMITED TO NEC, NFPA, ANSI/TIA,
AND ISO 9001.
C. EQUIPMENT AND MATERIALS SHALL COMPLY WITH UL
LISTING AND EACH ITEM STAMPED OR LABELED AS
SUCH.
D. FIRE SEAL ALL OPENINGS INCLUDING UNUSED
SPARES AFTER CABLING INSTALLATION, AS REQUIRED
BY ASTM El 19, U L263, NFPA 70 AND 251.
KEY NOTES:
OPROVIDE 4' X 8' X 3/4" FIRE RATED AC GRADE
PLYWOOD, PAINTED WITH FIRE -RETARDANT
PAINT, LEAVING STAMP EXPOSED. MOUNT
PLYWOOD VERTICALLY STARTING 6" A.F.F. ALL
PLYWOOD PANELS SHALL BE MOUNTED IN
CONTACT WITH EACH OTHER, LEAVING NO
GAPS BETWEEN PANELS. (TYPICAL).
O2 PROVIDE 2-POST RACK, UNIVERSAL, 84-INCH
HIGH X 19-INCH WIDE X 45RU, BLACK, MARKED
AND NUMBERED RACK UNITS, 1500 LB LOAD
CAPACITY. REFER TO RACK ELEVATION FOR
ADDITIONAL INFORMATION.
(�)PROVIDE NETWORK CABINET.
O4 PROVIDE VERTICAL CABLE MANAGEMENT
FRONT AND REAR, 84-INCH HIGH X 6-INCH WIDE
X 16.4-INCH DEEP WITH DUAL HINGE METAL
DOOR, 82.8-INCH HIGH X 6-INCH WIDE X 16-INCH
DEEP.
O5 PROVIDE VERTICAL CABLE MANAGEMENT OF
FRONT AND REAR, 84-INCH HIGH X 10-INCH
WIDE X 16.4-INCH DEEP WITH DUAL HINGED
METAL DOOR, 82.8-INCH HIGH X 10.1-INCH WIDE
X 16-INCH DEEP.
O6 PROVIDE 18" LADDER RACK MOUNTED AT 7'-6"
AFF TO BOTTOM OF TRAY. INCLUDE
ASSOCIATED MOUNTING HARDWARE SUPPORT.
O7 PROVIDE 18-INCH WIDE VERTICAL LADDER
RACK, BLACK.
O8 3/8" THREADED ROD, CLAMPED TO BEAM
ABOVE.
OBUTT SPLICE KIT, BLACK.
10 STRINGER RADIUS DROP, BLACK.
11 WALL -TO -RUNWAY L-BRACKET.
12 PROVIDE 6 AWG GROUNDING CABLE BETWEEN
EACH LADDER RACK SECTION, PER TIA-607.
13 PROVIDE 2RU, 19-INCH EIA UNIVERSAL
HORIZONTAL CABLE MANAGER, SINGLE SIDED
WITH SNAP -ON COVER THAT OPENS 180
DEGREES UP OR DOWN, 3.5-INCHES HIGH X 19-
INCHES WIDE X 5.14 INCHES DEEP,
CHATSWORTH CATALOG NO.30130-719.
14 PROVIDE 4RU 19-INCH FIBER ENCLOSURE
15 PROVIDE 2RU 19-INCH COPPER PATCH PANEL.
16 PROVIDE 3RU UPS MIN 6kW WITH L6-30 INPUT 1
STRIDE BUS RAPID TRANSIT
SOUTH RENTON TRANSIT CENTER
BT105
TELECOM
TELECOM ROOM ST & KCM ELEVATIONS
TRANSIT CENTER
R-4332551
DEVELOPMENT ENGINEERING
msippo 11 /25/2025 Ul
DRAWING NO.:
BT120-JCE262
FACILITY ID:
BT120
SHEET No: REV:
629 1