Loading...
HomeMy WebLinkAboutR-43325600 N O N 0 m 0 N m W U w c� I W z a ry ~I 0 0- a ry I W D m OI O 00 LO a o LO I N66 >a Cn 0 N O m SLEEVE —i FAI SLEEVE —i ELECTRICAL ROOM L IDF ROOM IDF ROOM TBB TEBC — TBB TEBC ACEG ------ --———————— — — — — —� � — — — i I — — — — — — — — CABLE TRAY ACCESSIBLE ---- CABLE RUNWAY CEILING ----- TGB RACKS --- ------ (TYP.) TGB ----- TBB TBB ELECTRICAL PANEL(TYP ------ SLEEVE ---- SLEEVE U SLEEVE n SLEEVE ELECTRICAL MDF ROOM 1 IDF ROOM SERVICE ENTRANCE SLEEVE TEBC TBB 6 AWG BONDING STRAP / TEBC (TYP) BCT _ ----—————— — — — — —-) — — i TEBC — — — — — — — — CABLE TRAY ACCESSIBLE -- - CABLE RUNWAY CEILING e ,® TMGB RACKS/FRAMES/CABINETS/ AC GROUNDING ELECTRODE ' ENCLOSURES (TYP.) TGB SYSTEM PER DIV 26 O BEP (BUILDING ENTRANCE PROTECTION) IILJ GENERAL NOTES: --------------------i A. THIS DETAIL CONVEYS REQUIREMENTS FOR THE CONSTRUCTION OF THE GROUNDING AND BONDING SYSTEM TO PROVIDE A PERMANENT BONDING INFRASTRUCTURE FOR COMMUNICATIONS SYSTEMS, BUT IS GENERIC IN NATURE. SOME ELEMENTS SHOWN MAY NOT BE PRESENT IN THE PROJECT, BUT THOSE ELEMENTS THAT ARE PRESENT SHALL BE GROUNDED AS SHOWN. REFER TO FLOOR PLANS, ELEVATIONS, AND SPECIFICATIONS FOR EXACT LOCATIONS OF GROUNDING AND BONDING ELEMENTS. B. THE TELECOMMUNICATIONS GROUNDING AND BONDING SYSTEM IS BONDED TO THE BUILDING GROUNDING SYSTEM AND IS INTENDED TO PROVIDE A PERMANENT BONDING INFRASTRUCTURE FOR COMMUNICATIONS SYSTEMS. THE PERFORMANCE OF TELECOMMUNICATIONS GROUNDING AND BONDING SYSTEM IS DEPENDANT UPON THE INTEGRITY OF THE BUILDING GROUNDING SYSTEM. THE BUILDING GROUNDING SYSTEM IS COMPRISED OF THE AC ELECTRODE GROUNDING SYSTEM AND THE EQUIPMENT GROUNDING SYSTEM SPECIFIED IN THE DIVISION 26 SPECIFICATION SECTION ELECTRICAL - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS. C. GROUNDING BACKBONE, ALL CONDUIT SLEEVES AND TMGB / TGB IN EACH TR PROVIDED BY ELECTRICAL CONTRACTOR. D. GROUNDING TO ELEMENTS WITHIN TR PROVIDED BY SCS CONTRACTOR. E. CABLE TRAY AND GROUNDING OF CABLE TRAY BY ELECTRICAL CONTRACTOR. F. CABLE RUNWAY AND GROUNDING OF CABLE RUNWAY BY SCS CONTRACTOR. G. GROUNDING EQUALIZERS (GEs) ARE NOT SHOWN ON THE DETAIL FOR CLARITY AND ARE NOT ALWAYS REQUIRED. REFER TO THE ELECTRICAL CONTRACTOR AND DIVISION 26 SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. H. THE CONDUIT SLEEVE(S) FOR THE ROUTING OF THE GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO THE LATEST EDITION OF THE NEC. THE MINIMUM SIZE SHALL BE 1-INCH. 0 12/10/20241 DS MF DTF ISSUED FOR BID No. DATE DSN CHK APP REVISION GROUNDING AND BONDING SYSTEM SCALE: N.T.S. DESIGNED BY: D. STOLTZ DRAWN BY: M. SANTO CHECKED BY: M.FREEMAN APPROVED BY: D. TAFT-FARREN LEGEND BT120-JCD506 TBB CONDUCTOR SIZES INSULATED GROUND WIRE 0 TO 20 FEET = #4 AWG 6 AWG STRANDED, GREEN 20 TO 26 FEET = #3 AWG INSULATED GROUND WIRE 26 TO 33 FEET = #2 AWG OSP COPPER CABLE 33 TO 44 FEET = #1 AWG 44 TO 52 FEET = #1/0 AWG 52 TO 66 FEET = #2/0 AWG GREATER THAN 66 FEET = #3/0 AWG .;acobs SUBMITTED BY: 12102124 R. PARGAS 4STJ?IDE BRT General Engineering Consultant DATE: REVIEWED BY: 09/06/2024 J. ALTCHECH 2 U z 19 1/4-INCH - 3/4-INCH 1/4-INCH DIAMETER (TYP) 1/4-INCH x 1/2-INCH (TYP) ACCOMODATES "A" ALL BARS ARE MANUFACTURED SPACED TWO HOLE LUGS. FROM 1/4-INCH THICK ELECTROLYTIC TOUGH PITCH COPPER ALLOY 110. GROUNDING - RACK BONDING BUSBAR (RBB) SCALE: N.T.S. 1/ 5/8 PROVIDE STANDARD BICSI PATTERN CONFIGURATION 31/2_00� 1 3/4 BT120-JCD506 STAND-OFF WALL MOUNTING 20\ BRACKET ®®® INSULATOR 1/8 00 0 ®®®® ®® 0®0 5/16 DIA. HOLE 7/16 DIA. HOLE #350 KCMIL TELECOMMUNICATIONS BONDING CONDUCTOR(TBC) TO MAIN ELECTRICAL GROUND POINT 0 GROUNDING - PRIMARY BONDING BUSBAR (PBB) SCALE: N.T.S. 1/ 2 1/2 20 1 1/8 STAND-OFF ® WALL MOUNTED BRACKET INSULATOR 5/8-J ® ® 0�0 PROVIDE STANDARD BICSI PATTERN CONFIGURATION 0 5/16 DIA. HOLE 7/16 DIA. HOLE EXOTHERMIC WELD CONNECTION #4/0 TELECOMMUNICATIONS BONDING BACKBONE (TBB) TO PRIMARY BONDING BUSBAR (PBB) 1 1 3/4 MOUNT 12-INCHES AFF TO BOTTOM OF PBB. .19 BT120-JCD506 MOUNT 12-INCHES AFF TO BOTTOM OF SBB. GROUNDING - SECONDARY BONDING BUSBAR SCALE: N.T.S. SCALE: Q w FILENAME: Q U) � S1-BT120-J-BLD-v2020 w Z J J SOUNDTRANSIT . CONTRACT No.: RTA /CN 02 -24 05 DATE: SUBMITTAL DATE: 12/04/2024 09/06/2024 L VELOPMENT ENGINEERING msippo 11 /25/2025 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 TELECOM INSTALLATION DETAILS TRANSIT CENTER BT120-JCD506 R-4332560 DRAWING NO.: BT120-JCD506 FACILITY ID: BT120 SHEET No: REV: 638 0