HomeMy WebLinkAboutR-4332563cY) 0 W 0 N 0 N 0 J m 0 N H m W U w C� I H W z Q 0 a I W m 0 I 0 co 00 LO co a �I LO ti U) L N o 0 co N cY) L N _ (.0 m SECURITY GENERAL NOTES ABBREVIATIONS SECURITY LEGEND AND SYMBOLS KEY NOTES: SYMBOL DESCRIPTION 10 FURNISH AND INSTALL (1) 18 AWG 2 CONDUCTOR CABLE. 1. DO NOT SCALE FROM DRAWINGS. THESE DRAWINGS ARE REPRESENTATIVE FOR THE FLOOR PLANS. FIELD ACAMS ACCESS CONTROL & ALARM MONITOR SYSTEM 20 FURNISH AND INSTALL (1) 22 AWG 4 CONDUCTOR CABLE. VERIFY ALL REQUIRED DIMENSIONS PRIOR TO INSTALLATION. 03 FURNISH AND INSTALL (1) 22 AWG 6 CONDUCTOR SHIELDED CABLE. 2. ALL SECURITY EQUIPMENT SHALL BE APPROVED FOR INSTALLATION BY THE CITY REPRESENTATIVE. CAM CAMERA q CENTERLINE CONDUIT SURFACE MOUNTED 40 FURNISH AND INSTALL WALL MOUNT CARD READER.NDUIT 3. EXACT LOCATION AND MOUNTING REQUIREMENTS FOR ALL SECURITY EQUIPMENT SHALL BE REVIEWED IN CR CARD READER COCCO O ONLY CONDUIT UNDERGROUND OFURNISH AND INSTALL SURFACE MOUNT DOOR CONTACT. THE FIELD AND COORDINATED WITH THE OWNER. CONTROL — — — — � CONDUIT CONTINUATION 4. CONTRACTOR SHALL FIRE SEAL ALL CORES AND PENETRATIONS ASSOCIATED WITH THE SECURITY SCOPE DID DOOR INTRUSION DETECTOR FIELD ROUTE 1 INCH CONDUIT TO SECURITY CONTROL PANEL. O OF THE WORK FOR THIS PROJECT. FIRE SEAL SHALL MEET OR EXCEED THE FIRE RATING OF THE MEDIA DDOOR STATUS CONTACT — — — — CONDUIT STUB BEING PENETRATED. 07 FURNISH AND INSTALL REQUEST -TO -EXIT. (E) EXISTING SECURITY EQUIPMENT ENCLOSURE 5. ALL CONDUIT, RACEWAYS, PULLBOX AND ASSOCIATED HARDWARE TO BE INSTALLED IN ACCORDANCE WITH 08 FURNISH AND INSTALL ROLL -UP DOOR CONTACT. THE REQUIREMENTS OF THE DIVISION 26 SPECIFICATIONS. EA. EACH ELC ELECTRIFIED MORTISE LOCK Efl JUNCTION BOX SIZED PER NEC OCAMERA TYPE PER DRAWINGS AND SPECIFICATIONS. LENS SIZE AS 6. UNLESS OTHERWISE NOTED ALL SECURITY RELATED ELECTRIC LOCK HARDWARE SHALL BE PROVIDED BY EPB ELECTRICAL PULL BOX REQUIRED TO OBTAIN DESIRED VIEW. INCLUDE APPROPRIATE MOUNTING OTHERS. EXST EXISTING EPB ELECTRICAL PULLBOX HARDWARE FOR THE LOCATION. 7. REQUEST TO EXIT DEVICES DO NOT PRECLUDE EXITING FROM THE INTERIOR. ALL EXISTS ARE FREE EGRESS AND SHALL NOT REQUIRE THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT TO EXIT. FBO FURNISHED BY OTHERS SPB SECURITY PULLBOX 10 INCLUDE TILE BRIDGE AND ELECTRICAL BACKBOX FOR CAMERAS FDU FIBER OPTIC DISTRIBUTION UNIT MOUNTED IN ACOUSTICAL TILE. 8. POWER AND COMMUNICATION WIRING SHALL BE PROVIDED IN SEPARATE CONDUITS AS SHOWN. MAINTAIN FOC FIBER OPTIC MEDIA CONVERTER FOPP FIBER OPTIC PATCH PANEL SPD SURGE PROTECTION DEVICE 12" SEPARATION BETWEEN POWER AND COMMUNICATION CONDUITS WHEN PARALLEL RUNS EXCEED 10' IN 11 PROVIDE ACCESS CONTROL PANEL TO ACCOMMODATE REQUIRED LENGTH. COMPONENTS. GO GATE OPERATOR O JUNCTION BOX SIZED PER DETAIL 0 I T E R IT 9. CONTRACTOR TO PROVIDE ALL CABLING, CONNECTIONS AND DEVICES AS SHOWN ON THE DRAWINGS TO El CARD READER . PROVIDE A COMPLETE AND OPERATIONAL SYSTEM. IC INTERCOM 13 PROVIDED BY TELECOM CONTRACTOR. REFER TO SHEET BT120-JCE262 10. CONTRACTOR TO UNIQUELY TAG ALL ADDRESSABLE SECURITY SYSTEM COMMON WITH AN EQUIPMENT IFP INTELLIGENT FIELD PROCESSOR IN INPUT DS DOOR STATUS CONTACT FOR DETAILS. IDENTIFICATION TAG, PER THE SPECIFICATIONS AND EQUIPMENT NUMBERING SYSTEM NOMENCLATURE R PR ED B ECUCON CTO SHOWN ON THIS SHEET. KPD KEYPAD OE ELECTRIFIED MORTISE LOCK 15 PROVIDE HOME -RUN 1" CONDUITS FROM CARD READERS AND DOOR 11. CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING ALL WORK IN STRICT COMPLINCE WITH NATIONAL ELECTRIC CODE (NEC) 70. LMN LATCH MONITOR MP MECHANICAL PANIC CONTACT TO ACCESS CONTROL PANEL IN THE TELECOM ROOM (TYPICAL). 12. CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING ALL WORK IN STRICT COMPLINCE WITH AMERICAN MP MECHANICAL PANIC ALARM El REQUEST TO EXIT SWITCH 16 PROVIDE (1) 6" x 6" x 4" NEMA 1 JUNCTION BOX. MOUNTED ABOVE THE DISABILITY ACT (ADA). MS MOTION SENSOR CEILING ON THE SECURE SIDE, AT EACH ACCESS CONTROLLED DOOR OK KEYPAD T C 13. CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING ALL WORK IN STRICT COMPLINCE WITH INTERNATIONAL BUILDING CODE (IBC). (N) NEW 0 TAMPER SWITCH 17 O PROVIDED BY OWNER. INSTALLED BY SECURITY CONTRACTOR. 14. CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING ALL WORK IN STRICT COMPLINCE WITH OH OPPOSITE HAND ST REQUIREMENT MANUAL. OUT OUTPUT GO GATE OPERATOR PS POWER SUPPLY El INTERCOM SECURITY WIRE AND CABLE - REFERENCE RX REQUEST -TO -EXIT O LIMIT SWITCH (EXCERPT FROM SECTION 28 05 13 SECWS SECURITY WORKSTATION MS MOTION SENSOR TYPE A: SMARTWIRE MODEL 4461140 (LATEST VERSION), ONE 18 AWG FOUR CONDUCTOR NON -SHIELDED, ONE SPB SECURITY PULL BOX 22 AWG, SIX CONDUCTOR SHIELDED, ONE 22 AWG, FOUR CONDUCTOR NON -SHIELDED, AND ONE 22 El PEDESTAL AWG, TWO CONDUCTOR NON -SHIELDED, OR APPROVED EQUAL. TMP TAMPER SWITCH TX TRANSMITTER PTZ PAN -TILT -ZOOM CAMERA TYPE B: WEST PENN MODEL AQC3186 (LATEST VERSION), 18 AWG, SIX CONDUCTOR TWISTED, SHIELDED, WATERBLOCKED CONSTRUCTION OR APPROVED EQUAL. UON UNLESS OTHERWISE NOTED FIX FIXED CAMERA TYPE C: WEST PENN MODEL 224 (LATEST VERSION), 18 AWG, TWO CONDUCTOR, NON -SHIELDED, OR APPROVED EQUAL. 180 FIXED CAMERA, 180 DEGREE TYPE D: WEST PENN MODEL 4246 (BLACK JACKET) (LATEST VERSION), 23 AWG, FOUR PAIR (CAT 6), OR APPROVED EQUAL. 360 FIXED CAMERA, 360 DEGREE TYPE E: MOHAWK MODEL M57622 (BLACK JACKET) (LATEST VERSION), 24 AWG, FOUR PAIR (CAT 6), WATERBLOCKED CONSTRUCTION OR APPROVED EQUAL. TYPE F: WEST PENN MODEL 241 (LATEST VERSION), 22 AWG, FOUR CONDUCTOR, NON -SHIELDED, OR APPROVED EQUAL. TYPE J: WEST PENN MODEL AQC224 (LATEST VERSION), 18 AWG, TWO CONDUCTOR, NON -SHIELDED, WATERBLOCKED CONSTRUCTION OR APPROVED EQUAL. TYPE K: WEST PENN MODEL AQC439 (LATEST VERSION), 22 AWG, FOUR PAIR, SHIELDED, WATERBLOCKED CONSTRUCTION, OR APPROVED EQUAL. TYPE R: FIBER OPTIC CABLING: CORNING FREEDM® CABLES, SINGLE JACKET, MULTIMODE 62.5/125 dam INDOOR/OUTDOOR, 12 FIBERS PER CABLE, MINIMUM, FIBERS TIGHT -BUFFERED, NOT IN GEL -FILLED LOOSE TUBE, 900 pm GRADED -INDEX GLASS, MINIMUM TENSILE STRENGTH; 600 POUNDS. EQUIPMENT NUMBERING SYSTEM EQUIPMENT CODE INSTANCE NUMBER LOCATION CODE R-4332563 YYYY YYY ## ** REFER TO GEN-GZN006 & GEN-GZN007 ENGINEERING ' FOR ADDITIONAL SYMBOLS AND LEGEND. FDEVELOPIMENT o 11 /25/2025 DESIGNED BY: R. SHADID TAFT, A SCALE: NITS STRIDE BUS RAPID TRANSIT DRAWING NO.: �tiwAs- o 7 Jacobs4fTmRIDEw J SOUTH RENTON TRANSIT CENTER BT105 BT120-JCN051 DRAWN BY: G. KING FLENAME: S1-BT120-J-BLD-v2020 FACILITY ID: BRT General Engineering Consultant z " BT120 CHECKED BY: CONTRACT No.: F. GIST 57079 ��� RFGISTFR�° SOUNDTRANSIT RTA/OA 0206-19 SECURITY 1 06/27/2025 RS FG FG ADDENDUM #2 SHEET No: REV: �SSIONAL 6��1 SYMBOLS AND LEGEND 0 12/10/2024 RS FG FG ISSUED FORBID APPROVED BY: SUBMITTED BY: DATE: REVIEWED BY: DATE: SUBMITTAL DATE: F. GIST 6127125 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 641 1 No. DATE DSN CHK APP REVISION