12.1) (2.32.4�
TELECOM
I
ELECTRICAL
BT120L1209
BT120-JCD552
SECURITY RACK
(CCTV)
BT120-CR-01 -
TELECOM
3T120L1208 ELECO
BT120-ACP-01
BT120-SC-18 BT120-SC-17 T120-SC-16
— — — — — —
1 — — —CR l CR
BT120-JCD552
BT120-SC-19
_ V-�BT120-ACR-06
16 BT120-ACR-07
STORAGE I I 1
1 I I BT120-JCD552
BT120L1210 _ � �
2 _ �� .G
BT120-ACR-08
BT120-SC-20
I 3
BT120-JCD551
IDS I BT120-DID-01
(2.5
OPERATOR
RESTROOM
BT120L1207
15
10
R
\�BT120-ACR-05
2
BT120-JCD552
2.6
C
OPERATOR
OPERATOR
RESTROOM
RESTROOM
BT120L1206
BT120L1205
OPERATOR
RESTROOM
BT120L1204
I (1
BT120-JCD552
JANITOR
BT120L1203
T120-SC-15
. 1�m
\-FBT120-ACR-04
\l\
LACTATION
ROOM
BT120LlM
n2.8
1 BT120-ACR-01 16
BT1�0-J�CD552 CR
SEC ..................�....L
--4
STORAG
RT19nI 1 gn11 1 1 BT1
BT120-SC-14 11 SECURITY
BT120-ACR-03 BT120-SC-13 I BLDG
BT120L1200�
GENERAL NOTES:
1. REFER TO DRAWING BT120-JCN051 FOR LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
2. THIS PLAN DEPICTS THE GENERAL LOCATION OF EQUIPMENT, FIELD
DEVICES AND CABLE PATHWAYS. AVOID CONFLICTS WITH EXISTING
EQUIPMENT AND COORDINATE FINAL MOUNTING LOCATIONS AND
RACEWAY ROUTING WITH OWNER.
3. EQUIPMENT, FIELD DEVICES, CABLE AND CONDUITS SHALL BE LABELED
WITH APPROPRIATE TAG NUMBERS AS SHOWN ON THE LEGEND,
SPECIFICATIONS AND DETAILS.
4. REFER TO DIV 26 SPECIFICATIONS FOR CONDUIT REQUIREMENTS.
5. DETAILS AS SHOWN ON DWG BT120-JCD551 TO BT120-JCD555 SHALL BE
FOLLOWED WHETHER REFERENCED ON THE PLANS OR NOT.
6. ALL FACILITY DOORS HAVE CARD KEY ACCESS EXCEPT FOR OPERATOR
RESTROOM AND LACTATION ROOM, WHICH WILL BE KEYED ENTRY BY
DRIVERS FROM ST AND KCM.
7. REFER TO DRAWING BT120-JCS051 FOR SECURITY NETWORK RISER
DIAGRAM.
8. REFER TO TELECOM DRAWING BT120-JCP-122 FOR CAMERAS CONDUITS
PATHWAY, DETAILS AND CABLES SCHEDULE.
BT120-JCC
�2.
T
BT120-ACR7021 U
1
BT120-JCD552
PLATFORM
E nI
F N
G
H 8 4 0 8
CORE
FACILITY
GEN
KEY PLAN SCALE IN FEET
DEVELOPMENT ENGINEERING
msippo 11 /25/2025 R-4332565
DESIGNED BY: SCALE: DRAWING NO.:
R. SHADID � o wasN`9�p Q w 3/16" =1'-0° STRIDE BUS RAPID TRANSIT gT120-JCP223
DRAWN BY: Q- 7 FILENAME: SOUTH RENTON TRANSIT CENTER
G. KING vaCos w S1-BT120-J-BLD-v2020 BT105 FACILITY ID:
CHECKED BY: BRT General Engineering Consultant z � CONTRACT No.: BT120
1 06/13/2025 RS FG FG ADDENDUM #1 F. GIST �o�GIST VSOUNDTRANSIT SECURITY - �`�`<� RTA/OA 0206-19 SHEET No: REV:
0 12/10/2024 RS FG FG ISSUED FORBID APPROVED BY: SIGNAL G0 SUBMITTED BY: DATE: REVIEWED BY: DATE: SUBMITTAL DATE: CONDUIT PLAN
No. DATE DSN CHK APP REVISION IF. GIST 1 6/13/25 1R. PARGAS 112/10/2024 J. ALTCHECH 112/10/2024 12/10/2024 1
CORE FACILITY 643 1
CONDUIT AND WIRING SCHEDULE
CONDUIT TAG
EQUIPMENT
CONDUIT
SIZE
WIRE
TYPE
REMARK
COMMENTS
FROM
TO
BT120-SC-12
BT120-ACR-01
BT120-ACP-01
1-1"
1-TYPE'A'
ST
CARD READER
BT120-SC-13
BT120-ACR-02
BT120-ACP-01
1-1"
1-TYPE'A'
ST
CARD READER
BT120-SC-14
BT120-ACR-03
BT120-ACP-01
1-1"
1-TYPE'A'
ST
CARD READER
BT120-SC-15
BT120-ACR-04
BT120-ACP-01
1-1"
1-TYPE'A'
ST
CARD READER
BT120-SC-16
BT120-ACR-05
BT120-ACP-01
1-1"
1-TYPE'A'
ST
CARD READER
BT120-SC-17
BT120-ACR-06
BT120-ACP-01
1-1"
1-TYPE'A'
ST
CARD READER
BT120-SC-18
BT120-ACR-07
BT120-ACP-01
1-1"
1-TYPE'A'
ST
CARD READER
BT120-SC-19
BT120-ACR-08
BT120-ACP-01
1-1"
1-TYPE'A'
ST
CARD READER
BT120-SC-20
BT120-DID-01
BT120-ACP-01
1-1"
1-TYPE'C'
ST
DOOR CONTACT