HomeMy WebLinkAboutR-4332569N
C'7
C'7
O
0
W
0
N
O
N
0
J
m
0
N
m
U
w
C�
�I
z
Q
ry
0I
0-
ry
C/)I
D
m
O
I
0
co
00
LO
Q M
0 0
>1
N
Oi Cn
0
N O
LO cy)
m
O__''
____
REQUEST TO EXIT (RX),
HORIZONTAL FLUSH r rr
MOUNTED ON BACKBOX
A
ELECTRIFIED HINGE
PANIC HARDWARE
WITH ELECTRIFIED
LOCKSET
FUNCTIONALITY:
6" x 6" x 4" N E MA 1
JUNCTION BOX,
MOUNTED ON SECURE
SIDE OF DOOR
12"
DOOR STATUS SWITCH
(SURFACE MOUNT)
DOOR STATUS SWITCH
MAGNET (SURFACE MOUNT)
CARD READER FLUSH
MOUNTED ON SINGLE
GANG BACK -BOX
TO LOCAL
SECURITY
PANEL
IN THE NORMAL STATE THE DOOR IS CLOSED, LOCKED ON THE OUTSIDE AND UNLOCKED ON
THE INSIDE. NORMAL OPERATION IS BY CARD READER ON THE OUTSIDE AND BY MOTION
DETECTOR ON THE INSIDE. THE MOTION DETECTOR WILL SHUNT AN ALARM AND ENABLE
AUTHORIZED EXIT. IF THE DOOR IS OPENED WITHOUT THE OPERATION OF THE CARD READER
OR MOTION DETECTOR, THE ALARM CONDITION IS MONITORED AT THE SECURITY TERMINAL.
SINGLE DOOR CARD IN DOOR
W/ PANIC HARDWARE AND ELECTRIFIED LOCKSET
SCALE: NTS
C�I■■■�Y
CARD READER
FLUSH MOUNTED
ON SINGLE GANG
BACK -BOX
APPROX 6"
U_
Q
N
ELECTRIFIED HINGE
FUNCTIONALITY:
6" x 6" x 4" N E MA 1
JUNCTION BOX,
MOUNTED ON SECURE
SIDE OF DOOR
REQUEST TO EXIT (RX)
(HORZONTALLY SURFACE MOUN-
DOOR STATUS SWITCH
TO LOC
SECUR
PANEL
PANIC HARDWARE WITH ELECTRIFIED
LOCKSET (ACTIVE LEAF)
IN NORMAL STATE THE DOOR IS CLOSED, LOCKED ON THE OUTSIDE AND UNLOCKED ON
THE INSIDE. NORMAL OPERATION IS BY CARD READER ON THE OUTSIDE AND BY MOTION
DETECTOR ON THE INSIDE. THE MOTION DETECTOR WILL SHUNT AN ALARM AND ENABLE
AUTHORIZED EXIT. IF THE DOOR IS OPENED WITHOUT THE OPERATION OF THE CARD
READER, THE ALARM CONDITION IS MONITORED AT THE SECURITY TERMINAL.
DOUBLE DOOR CARD IN DOOR
W/ PANIC HARDWARE AND ELECTRIFIED LOCKSET
SCALE: NTS
DESIGNED BY:
R. SHADID
DRAWN BY:
G. KING
CHECKED BY:
F. GIST
0 12/10/2024 RS FG FG ISSUED FORBID APPROVED BY:
No. DATE DSN CHK APP REVISION IF. GIST
BT120-JCP223
BT120-JCP223
.;acobs
SUBMITTED BY:
11/15/24 R. PARGAS
4STmRIDE
BRT General Engineering Consultant
DATE: REVIEWED BY:
09/06/2024 J. ALTCHECH
Q w
U)cn
W J
Z J
SOUNDTRANSIT
DATE:
12/04/2024
SCALE:
NTS
FILENAME:
S1-BT120-J-BLD-v2020
CONTRACT No.:
RTA/CN 0205-24
SUBMITTAL DATE:
09/06/2024
GENERAL NOTES:
1. REFER TO DRAWING BT120-JCN051 FOR LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
2. EQUIPMENT AND DEVICE LABELS: EQUIPMENT PANELS, FIELD DEVICES,
CABLES, AND CONDUITS SHALL BE LABELED WITH THE APPROPRIATE
TAG NUMBERS AS SHOWN ON THE LEGEND, SPECIFICATIONS, AND
DETAILS.
3. DOOR DETAILS ARE BASED ON A RIGHT HAND REVERSE OPERATION.
DOORS MAY DIFFER ON FLOOR PLANS. REFERENCE FLOOR PLANS FOR
ACTUAL HANDING AND SWING OF DOOR.
4. EQUIPMENT, INTERCONNECTION CABLES, AND WIRING SHALL BE
INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
5. SEE SPECIFICATION SECTION 08710 "DOOR HARDWARE" FOR
STANDARD HARDWARE TYPES.
STRIDE BUS RAPID TRANSIT
SOUTH RENTON TRANSIT CENTER
BT105
SECURITY
DETAILS
R-4332569
DEVELOPMENT ENGINEERING
msippo 11 /25/2025 U1
DRAWING NO.:
BT120-JCD552
FACILITY ID:
BT120
SHEET No: REV:
647 0