Loading...
HomeMy WebLinkAboutR-4332571N co co It A W 1> 0 N 0 N > 0 m 0 N m U w C� �I z Q ry ~I a Q C/)I m of 0 co co 2 't a o rn I co Nu) o N o CO cY) 75; o - 0 m WIRING DEN OR ELECTR EQUIPMENT CONDUIT PIPE STRAF FLOOR OR PLATFORM CONCRETE OR MASONRY WALL OR COLUMN NOTES 2 AND 3 FOR CONTROL STATIONS MOUNT AT 4'-0"± NOTES: 1. ALL MOUNTING HARDWARE SHALL BE STAINLESS STEEL. USE BOTH WASHER AND LOCK WASHERS UNDER ALL NUTS. 2. ON CONCRETE WALLS USE STAINLESS STEEL CONCRETE ANCHORS. MOUNT ENCLOSURE ON SPACERS OF MIN 1/2" SCHEDULE 80 PVC CONDUIT. 3. BOXES 6 INCHES SQUARE AND SMALLER SHALL BE SUPPORTED BY TWO ANCHORS, MIN. LARGER BOXES SHALL BE SUPPORTED AS REQUIRED BY CALCULATION; FOUR ANCHORS MIN. 4. SUBMIT FINAL DESIGN AND CALCULATIONS FOR SUPPORT AND ANCHORAGE AS SPECIFIED DEVICE MOUNTING WALL OR COLUMN SCALE: NTS OR 1/2" Em TOP FRONT DRILL HOLE, AS REQUIRED FOR CONDUIT FITTING MIN 12 GAUGE SHEET METAL GALVANIZED AFTER FABRICATION FLEXIBLE CONDUIT CONDUIT CONNECT CONDUIT CONNECT SIDE FLEXIBLE CONDUIT SUPPORT(4) SCALE: NTS DESIGNED BY: R. SHADID DRAWN BY: G. KING CHECKED BY: F. GIST 0 12/10/2024 RS FG FG ISSUED FORBID APPROVED BY: No. DATE DSN CHK APP REVISION F. GIST CONDUIT CONCRETE ANCHOR SUPPORT AS SPECIFIED 00 �:peo0,01 O°o 0 O 0.'0 O � Q 0 � � • v Lill= Oo O °o. 0 O,-o 4, O O o p U.o. O O . . O .O . CONCRETE ANCHOR INSTALLATION SCALE: NTS GRADE GROUNDING CONNECTORS: "O-Z/G E D N EY" TYPE ABG, OR EC GROUND TEST WELL SCALE: NTS GROUNDING WELL •��1 CONDUI CLAMP CONCRETE ANCHOR FORMED STEEL CHANNEL NOTES: 1. SUPPORT ALL EXPOSED CONDUITS ON FORMED STEEL CHANNELS. 2. SUBMIT FINAL DESIGN AND CALCULATIONS FOR SUPPORT AND ANCHORAGE AS SPECIFIED. CONDUIT SUPPORT ON STRUCTURE SCALE: NTS EXISTING BUILDING WALL LB LB CONDULET CONDULET a 9 a <, FINISH GRADE 14 'RAVEL \� :ROUNDING — ',ONDUCTOR NOTES: ND ROD 1. INSTALL CONDUITS THROUGH EXISTING WALLS IN ACCORDANCE WITH THIS DETAIL IF NOT OTHERWISE INDICATED. .;acobs SUBMITTED BY: 11/15/24 R. PARGAS 2. DRILL HOLE USING METHODS THAT LEAVE A SMOOTH OPENING. SEAL OPENING AROUND CONDUIT, INSIDE, AND OUTSIDE, WITH ONE PART POLYURETHANE IMMERSIBLE SEALANT. CONDUIT ENTRANCE g SCALE: NTS SCALE: Q w M;rr NTS Q FILENAME: U 45T)?IDE w J S1-BT120-J-BLD-v2020 BRT General Engineering Consultant z " SOUNDTRANSIT CONTRACT No.: RTA/CN 0205-24 DATE: REVIEWED BY: DATE: SUBMITTAL DATE: 09/06/2024 J. ALTCHECH 12/04/2024 09/06/2024 GALVANIZED STEEL SHEET METAL ESCUTCHEON,TYP GALVANIZED STEEL PIP SLEEVE OR CORE DRILL HOLE IN CONCRETE WA JSULATION AS REQUIRED O FILL CAVITY :ONDUIT NOTES: 1. CONDUITS WHICH INDIVIDUALLY PASS THRU AN INTERIOR WALL SHALL BE INSTALLED IN ACCORDANCE WITH THIS DETAIL. IF WALL IS A FIRE WALL, FILL CAVITY WITH FIRE STOP SEALANT AS SPECIFIED. INTERIOR WALL PENETRATION SCALE: NTS STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 SECURITY STANDARD DETAILS DEVELOPMENT ENGINEERING 4 msippo 11 /25/2025 ' R-4332571 DRAWING NO.: BT120-JCD554 FACILITY ID: BT120 SHEET No: REV: 649 0