HomeMy WebLinkAboutHighlandsW-Construction Plans-Volume IIED
M
O
N
D
S
A
V
E
N
E
KI
R
K
L
A
N
D
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
SR
9
0
0
NE 12TH STHA
R
R
I
N
G
T
O
N
A
V
E
N
E
JE
F
F
E
R
S
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
04 05 06 07 08
11
10
01 02 03 09
QU
E
E
N
A
V
E
N
E
PI
E
R
C
E
A
V
E
N
E
PI
E
R
C
E
P
L
N
E
NE
S
U
N
S
E
T
B
L
V
D
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
HIGHLANDS RESERVOIR WATER MAIN IMPROVEMENTS PROJECTHIGHLANDS RESERVOIR WATER MAIN IMPROVEMENTS PROJECT
CITY OF RENTONCITY OF RENTON
NE 3RD ST.
NE 12TH ST.
ED
M
O
N
D
S
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
LAKE WA.SEE PROJECT VICINITY,
THIS SHEET
KING COUNTY
PROJECT LOCATION MAP
PROJECT VICINITY MAP
CONTACT PERSONNEL
CONTACT NAME POSITION TELEPHONE
CITY OF RENTON (WATER)KEN SRILOFUNG, P.E.CITY PROJECT MANAGER 425-430-7247
CITY OF RENTON (WATER)WATER MAINTENANCE MANAGER 425-430-7400
CITY OF RENTON (WATER)PATRICK PIERSON WATER MAINTENANCE SERVICES SUPERVISOR 425-430-7400
CITY OF RENTON (WATER)JOSHUA O'NEIL WATER UTILITY MAINTENANCE SUPERVISOR 425-430-7400
CITY OF RENTON (WATER)ABDOUL GAFOUR WATER UTILITY ENGINEERING MANAGER 425-430-7210
RH2 ENGINEERING KYLE PETTIBONE, P.E.CONSULTANT PROJECT MANAGER 503-446-2816
RH2 ENGINEERING RYAN FESKENS, P.E.CONSULTANT PROJECT ENGINEER 425-951-5396
PUGET SOUND ENERGY DUSTIN WELLER POWER AND NATURAL GAS 888-321-7779
QWEST/LUMEN TELEPHONE 800-526-3557
ONE-CALL LOCATE CALL 48 HRS BEFORE YOU DIG 800-424-5555 (OR 811)
RENTON FIRE DEPARTMENT NON-EMERGENCY 425-430-7000
RENTON FIRE DEPT. & FIRST AID 911 EMERGENCY 911
RENTON WASTEWATER MIKE BENOIT SANITARY SEWER ENGINEER 425-430-7206
RENTON SURFACE WATER JOE FARAH SURFACE WATER ENGINEERING MANAGER 425-430-7248
RENTON TELEMETRY & COMMUNICATIONS ERIC CUTSHALL ITS MAINTENANCE MANAGER 425-430-7400
RENTON ROADS & TRANSPORTATION JOHN KALMBACH STREET MAINTENANCE MANAGER 425-430-7400
KING COUNTY METRO TRANSIT 206-477-1140
MCI/VERIZON SCOTT CHRISTENSON SENIOR ENGINEER SPEC-OUTSIDE PLANT 425-471-1079
AT&T
COMCAST
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CO
V
E
R
S
H
E
E
T
A
N
D
G
E
N
E
R
A
L
I
N
F
O
R
M
A
T
I
O
N
WHERE,ID = SECTION/DETAIL REFERENCE NUMBER
## = DRAWING NUMBER ON WHICH DETAIL ORIGINATED OR RESIDES.
REFERENCE BUBBLES
DETAIL/SECTION REFERENCE BUBBLE -
REFERS READER TO THE DRAWING ON WHICH
THE DETAIL OR SECTION IS LOCATED.
PLAN REFERENCE BUBBLE - REFERS
READER BACK TO THE PLAN FROM WHICH
THE DETAIL OR SECTION ORIGINATED.
THE FOLLOWING CONVENTIONS HAVE BEEN USED WITHIN THESE DRAWINGS TO REFER THE READER BETWEEN THE SECTION/DETAIL AND
THE PLAN FROM WHICH IT IS REFERENCED.
X
X000
X
X000
SECTION AND DETAIL REFERENCES
CALL 48 HOURS BEFORE YOU DIG
ONE CALL 811
REPORT ALL SPILLS TO OWNER
PER SPECIAL PROVISIONS
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
O
V
.
D
W
G
SHOWN
G01 1 71
DRAWING NUMBERING SCHEMA
IN GENERAL, PLAN DRAWINGS ARE NUMBERED TO MAINTAIN CONSISTENT NUMBERING ACROSS ALL SHEET TYPES BASED ON LOCATION
(I.E. ALL "01" PLAN SHEETS WILL SHOW THE INTERSECTION OF EDMONDS AVE AND NE 12TH STREET). DRAWING NUMBER PREFIXES
ARE AS FOLLOWS:
'G' SHEETS = GENERAL
'P' SHEETS = EXISTING CONDITIONS, DEMOLITION, AND PREPARATION PLAN
'W' SHEETS = WATER MAIN PLAN AND PROFILE
'WX' SHEETS = WATER MAIN CROSS SECTIONS
'WC' SHEETS = WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS
'C' SHEETS = STORM WATER PLAN AND PROFILE
'E' SHEETS = ELECTRICAL AND COMMUNICATIONS PLAN
'R' SHEETS = RESTORATION PAVEMENT MARKINGS, AND CHANNELIZATION PLAN
'D' SHEETS = CIVIL AND UTILITIES DETAILS
APPROVED FOR CONSTRUCTION
KEN SRILOFUNG DATE
SHEET NO.SHEET TITLE SHEET LOCATION DWG NO.
1 COVER SHEET AND GENERAL INFORMATION G01
2 SYMBOLS, ABBREVIATIONS, AND NOTES G02
3 CONSTRUCTION NOTES 1 G03
4 CONSTRUCTION NOTES 2 G04
5 OWNER-PROVIDED STAGING AREA SITE PLAN G05
6 STATION BASELINE DEFINITION AND SURVEY CONTROL G06
7 EXISTING, DEMOLITION, AND PREPARATION PLAN 01 NE 12TH ST - EDMONDS AVE TO HARRINGTON AVE P01
8 EXISTING, DEMOLITION, AND PREPARATION PLAN 02 NE 12TH ST - EDMONDS AVE TO HARRINGTON AVE P02
9 EXISTING, DEMOLITION, AND PREPARATION PLAN 03 NE 12TH ST - HARRINGTON AVE TO KIRKLAND AVE P03
10 EXISTING, DEMOLITION, AND PREPARATION PLAN 04 NE 12TH ST - HARRINGTON AVE TO KIRKLAND AVE P04
11 EXISTING, DEMOLITION, AND PREPARATION PLAN 05 NE 12TH ST - KIRKLAND AVE TO MONROE AVE P05
12 EXISTING, DEMOLITION, AND PREPARATION PLAN 06 NE 12TH ST - KIRKLAND AVE TO MONROE AVE P06
13 EXISTING, DEMOLITION, AND PREPARATION PLAN 07 NE 12TH ST - MONROE AVE TO OLYMPIA AVE P07
14 EXISTING, DEMOLITION, AND PREPARATION PLAN 08 NE 12TH ST - MONROE AVE TO OLYMPIA AVE P08
15 EXISTING, DEMOLITION, AND PREPARATION PLAN 09 NE 12TH ST - OLYMPIA AVE TO QUEEN AVE P09
16 EXISTING, DEMOLITION, AND PREPARATION PLAN 10 MONROE AVE - NE 12TH ST TO SUNSET AVE P10
17 EXISTING, DEMOLITION, AND PREPARATION PLAN 11 MONROE AVE - NE 12TH ST TO SUNSET AVE P11
18 WATER MAIN PLAN AND PROFILE 01 NE 12TH ST - EDMONDS AVE TO HARRINGTON AVE W01
19 WATER MAIN PLAN AND PROFILE 02 NE 12TH ST - EDMONDS AVE TO HARRINGTON AVE W02
20 WATER MAIN PLAN AND PROFILE 03 NE 12TH ST - HARRINGTON AVE TO KIRKLAND AVE W03
21 WATER MAIN PLAN AND PROFILE 04 NE 12TH ST - HARRINGTON AVE TO KIRKLAND AVE W04
22 WATER MAIN PLAN AND PROFILE 05 NE 12TH ST - KIRKLAND AVE TO MONROE AVE W05
23 WATER MAIN PLAN AND PROFILE 06 NE 12TH ST - KIRKLAND AVE TO MONROE AVE W06
24 WATER MAIN PLAN AND PROFILE 07 NE 12TH ST - MONROE AVE TO OLYMPIA AVE W07
25 WATER MAIN PLAN AND PROFILE 08 NE 12TH ST - MONROE AVE TO OLYMPIA AVE W08
26 WATER MAIN PLAN AND PROFILE 09 NE 12TH ST - OLYMPIA AVE TO QUEEN AVE W09
27 WATER MAIN PLAN AND PROFILE 10 MONROE AVE NE - 12TH ST TO SUNSET BLVD W10
28 WATER MAIN PLAN AND PROFILE 11 NE 12TH ST - MONROE AVE TO OLYMPIA AVE W11
29 WATER MAIN CROSS SECTIONS 01 WX01
30 WATER MAIN CROSS SECTIONS 02 WX02
31 WATER MAIN CROSS SECTIONS 03 WX03
32 WATER MAIN CROSS SECTIONS 04 WX04
33 WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS 01 NE 12TH ST - EDMONDS AVE INTERSECTION WC01
34 WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS 02 NE 12TH ST - HARRINGTON AVE INTERSECTION WC02
35 WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS 03 NE 12TH ST - HARRINGTON AVE TO HARRINGTON PL WC03
36 WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS 04 NE 12TH ST - HARRINGTON PL TO JEFFERSON AVE WC04
37 WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS 05 NE 12TH ST - JEFFERSON AVE TO KIRKLAND AVE WC05
38 WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS 06 NE 12TH ST - KIRKLAND AVE TO SUNSET BLVD WC06
39 WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS 07 NE 12TH ST - SUNSET BLVD INTERSECTION WC07
40 WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS 08 NE 12TH ST - SUNSET BLVD TO LYNNWOOD AVE WC08
41 WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS 09 NE 12TH ST - LYNNWOOD AVE TO MONROE AVE WC09
42 WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS 10 NE 12TH ST - MONROE AVE TO OLYMPIA AVE WC10
43 WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS 11 NE 12TH ST - MONROE AVE TO OLYMPIA AVE WC11
44 WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS 12 NE 12TH ST - PIERCE PL TO PIERCE AVE WC12
45 WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS 13 NE 12TH ST - PIERCE AVE TO QUEEN AVE WC13
46 WATER MAIN TESTING AND FINAL CONNECTION CONFIGURATIONS 14 MONROE AVE NE - 12TH ST TO SUNSET BLVD WC14
47 STORM WATER PLAN AND PROFILE 01 NE 12TH ST - EDMONDS AVE TO HARRINGTON AVE C01
48 STORM WATER PLAN AND PROFILE 02 NE 12TH ST - HARRINGTON AVE TO HARRINGTON PL C02
49 STORM WATER PLAN AND PROFILE 03 NE 12TH ST - KIRKLAND AVE TO LYNNWOOD AVE NE C03
50 STORM WATER PLAN AND PROFILE 04 NE 12TH ST - MONROE AVE TO OLYMPIA AVE C04
51 STORM WATER PLAN AND PROFILE 05 NE 12TH ST - MONROE AVE TO OLYMPIA AVE C05
52 STORM WATER PROFILES C06
53 ELECTRICAL AND COMMUNICATION PLAN 01 NE 12TH ST - EDMONDS AVE TO HARRINGTON AVE E01
54 ELECTRICAL AND COMMUNICATION PLAN 02 NE 12TH ST - HARRINGTON AVE TO KIRKLAND AVE E02
55 ELECTRICAL AND COMMUNICATION PLAN 03 NE 12TH ST - KIRKLAND AVE TO MONROE AVE E03
56 ELECTRICAL AND COMMUNICATION PLAN 04 NE 12TH ST - MONROE AVE TO OLYMPIC AVE E04
57 RESTORATION, PAVEMENT MARKINGS, AND CHANNELIZATION PLANS 01 NE 12TH ST - EDMONDS AVE TO HARRINGTON AVE R01
58 RESTORATION, PAVEMENT MARKINGS, AND CHANNELIZATION PLANS 02 NE 12TH ST - EDMONDS AVE TO HARRINGTON AVE R02
59 RESTORATION, PAVEMENT MARKINGS, AND CHANNELIZATION PLANS 03 NE 12TH ST - HARRINGTON AVE TO KIRKLAND AVE R03
60 RESTORATION, PAVEMENT MARKINGS, AND CHANNELIZATION PLANS 04 NE 12TH ST - HARRINGTON AVE TO KIRKLAND AVE R04
61 RESTORATION, PAVEMENT MARKINGS, AND CHANNELIZATION PLANS 05 NE 12TH ST - KIRKLAND AVE TO MONROE AVE R05
62 RESTORATION, PAVEMENT MARKINGS, AND CHANNELIZATION PLANS 06 NE 12TH ST - KIRKLAND AVE TO MONROE AVE R06
63 RESTORATION, PAVEMENT MARKINGS, AND CHANNELIZATION PLANS 07 NE 12TH ST - MONROE AVE TO OLYMPIA AVE R07
64 RESTORATION, PAVEMENT MARKINGS, AND CHANNELIZATION PLANS 08 NE 12TH ST - MONROE AVE TO OLYMPIA AVE R08
65 RESTORATION, PAVEMENT MARKINGS, AND CHANNELIZATION PLANS 09 NE 12TH ST - OLYMPIA AVE TO QUEEN AVE R09
66 RESTORATION, PAVEMENT MARKINGS, AND CHANNELIZATION PLANS 10 MONROE AVE - NE 12TH ST TO SUNSET AVE R10
67 CIVIL AND UTILITIES DETAILS 01 D01
68 CIVIL AND UTILITIES DETAILS 02 D02
69 CIVIL AND UTILITIES DETAILS 03 D03
70 CIVIL AND UTILITIES DETAILS 04 D04
71 CIVIL AND UTILITIES DETAILS 05 D05
WINTER 2026
VOLUME II OF II
LINETYPESSURFACE SYMBOLS
STORM STRUCTURE TABLE SEWER STRUCTURE TABLE WATER STRUCTURE TABLE
16'' DI W (435)
12'' DI W (565)
WATER UTILITYWATER UTILITY
PREPARATION AND DEMOLITION LEGEND
\\\\\\\\
XXXXXX
TELEMETRY
FO FO
STORM UTILITY
PROFILE VIEW SYMBOLS
RESTORATION LEGEND
CHANNELIZATION LEGEND
STAGING AREA LEGEND
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
SUBSURFACE UTILITY LEGEND
(COR)- PAINT MARKS LOCATED BY CITY OF RENTON LOCATORS
(MT.VIEW) - PAINT MARKS LOCATED OR VERIFIED BY MOUNTAIN VIEW LOCATING SERVICES, LLC
THE CLASSIFICATIONS FOR SUBSURFACE UTILITIES ARE OUTLINED AND EXPLAINED IN THE FOLLOWING LIST:
UTILITY QUALITY LEVEL A. - PRECISE HORIZONTAL AND VERTICAL LOCATION OF UTILITIES OBTAINED BY THE
ACTUAL EXPOSURE OF (OR VERIFICATION OF PREVIOUSLY EXPOSED AND SURVEYED UTILITIES AND
SUBSEQUENT MEASUREMENT OF SUBSURFACE UTILITIES, USUALLY AT A SPECIFIC POINT. UNLESS OTHERWISE
NOTED, QUALITY LEVEL A IS ONLY APPLICABLE AT POTHOLED LOCATIONS ON THE PLANS AT ALL OTHER
AREAS, THE UTILITY SHOULD BE ASSUMED TO BE QUALITY LEVEL B.
UTILITY QUALITY LEVEL B - INFORMATION OBTAINED THROUGH THE APPLICATION OF APPROPRIATE SURFACE
GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE AND APPROXIMATE HORIZONTAL POSITION OF
SUBSURFACE UTILITIES.
UTILITY QUALITY LEVEL C - INFORMATION OBTAINED BY SURVEYING AND PLOTTING VISIBLE ABOVE-GROUND
UTILITY FEATURES
UTILITY QUALITY LEVEL D - INFORMATION DERIVED FROM EXISTING RECORDS OR ORAL RECOLLECTIONS.
NOTE: THE USE OF THE LINETYPES PROVIDED ABOVE WAS A PRIMARY METHOD FOR INDICATING THE
ACCURACY OF THE UTILITIES SHOWN WITHIN THESE PLANS. WHEN THE SOURCE OF THE INFORMATION WAS
UNKNOWN OR THE METHOD FOR LOCATING THE UTILITIES WAS UNAVAILABLE, QUALITY LEVEL D WAS USED
AS THE DEFAULT.
QUALITY LEVEL D
QUALITY LEVEL C
QUALITY LEVEL B
QUALITY LEVEL A
LEGEND
EXISTING
EXISTING STRUCTURES TABLE
EXISTING STRUCTURE TABLES PROVIDED
FOR UTILITY STRUCTURES IN CONGESTED
LOCATIONS WHERE CALLOUTS CAN NOT
BE CLEARLY SHOWN ON THE PLANS. NOT
ALL STRUCTURES ARE LISTED HERE. SEE
PLANS FOR ADDITIONAL INFORMATION.
AH
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
0
.
D
W
G
SHOWN
G02 2 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
SY
M
B
O
L
S
,
A
B
B
R
E
V
I
A
T
I
O
N
S
,
A
N
D
N
O
T
E
S
ASPH ASPHALT
BE BOTTOM ELEVATION
BFV BUTTERFLY VALVE
B/G BACKGROUND
BPS BOOSTER PUMP STATION (WATER UTILITY)
CB CATCH BASIN
CHNL CHANNEL
CLFNC CHAINLINK FENCE
CMP CORRUGATED METAL PIPE
CONC CONCRETE
CP CONCRETE PIPE
CPP CONCRETE PRESSURE PIPE
CTR CENTER
D/S DOWNSTREAM
DI DUCTILE IRON
DIA DIAMETER
DIP DUCTILE IRON PIPE
DWC DRIVEWAY CUT
EF EACH FACE
EG EXISTING GRADE
EL ELEVATION
ELEV ELEVATION
EW EACH WAY
EX EXISTING
FDC FIRE DEPARTMENT CONNECTION
FF FINISHED FLOOR
FG FINISHED GRADE
FH FIRE HYDRANT
GPH GAS POTHOLE
GSP GALVANIZED STEEL PIPE
GV GATE VALVE
IE INVERT ELEVATION
LTF LENGTH TO FIT
MDD MAXIMUM DRY DENSITY
NIC NOT IN CONTRACT
NOM NOMINAL
OC ON CENTER
PFL PAINTED FOG LINE
PH POTHOLE
PJF PREMOLDED JOINT FILLER
PP POLYPROPYLENE PIPE
PPB PEDESTRIAN PUSH BUTTON
PPH POWER POTHOLE
PROP PROPOSED
PRV PRESSURE REDUCING VALVE
PRV PRESSURE RELIEF VALVE
PVC POLYVINYL CHLORIDE
RCP REINFORCED CONCRETE PIPE
RJ RESTRAINED JOINT
ROPS RESERVOIR OVERFLOW PUMP STATION
SD STORM DRAIN
SDMH STORM DRAIN MANHOLE
SGN SIGN
SIM SIMILAR
SS SANITARY SEWER
SSMH SANITARY SEWER MANHOLE
SST STAINLESS STEEL
ST STORM
TBA TO BE ABANDONED
TBR TO BE REMOVED
TMH TELEPHONE MANHOLE
TN TOP OF NUT
TOF TOP OF FOOTING
TOW TOP OF WALL
TPN TAX PARCEL NUMBER
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
U/S UPSTREAM
UTP UTILITY POLE
W WATER
WCR WHEEL CHAIR RAMP
WFNC WOOD FENCE
WM WATER METER
WMH WATER MAN HOLE
WS WATER SERVICE
WV WATER VALVE
XRF TRANSFORMER
ABBREVIATIONS
PROPOSED
PH#
POTHOLE LOCATION AND ID
SEQUENCING AND PHASING
WORK REQUIRED TO INSTALL WATER MAINS AND STORM SYSTEM IMPROVEMENTS, INCLUDING MAKING CONNECTIONS TO EXISTING
WATER SYSTEM AND TRANSFER OF WATER SERVICES, WILL REQUIRE ADVANCED PLANNING AND COORDINATION WITH CITY OF RENTON
WATER OPERATIONS STAFF. CONTRACTOR TO ASSIST CITY IN PLANNING AND COORDINATION FOR WATER SERVICE TRANSFERS.
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
CONSTRUCTION NOTES
ADDRESSES
CRITERIA
GENERAL CONSTRUCTION
GENERAL NOTES
EXISTING UTILITIES
TRAFFIC CONTROL
WATER MAIN CONSTRUCTION NOTES
WATER MAIN ABANDONMENT AND TERMINATION NOTES
AH
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
0
.
D
W
G
SHOWN
G03 3 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
CO
N
S
T
R
U
C
T
I
O
N
N
O
T
E
S
1
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
SURFACE WATER DRAINAGE NOTES
SANITARY SEWER NOTES
TESC GENERAL NOTES
TREE PRESERVATION NOTES
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
0
.
D
W
G
SHOWN
G04 4 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
CO
N
S
T
R
U
C
T
I
O
N
N
O
T
E
S
2
CONSTRUCTION NOTES (CONTINUED)GENERAL NOTES AND STANDARD KEYNOTES
WATERMAIN PLAN AND PROFILE ALIGNMENT GENERAL NOTES
”
WATERMAIN CONNECTION DETAILS GENERAL NOTES
PREPARATION AND RESTORATION STANDARD KEYNOTES
SURFACE WATER DRAINAGE NOTES
·
·
·
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
xxxx
x
x
x
x
x
x
x
x
x
x
x
x
x x
P
P
P
P
P
P
P
P
T
E
L
T
E
L
TEL
TEL
TEL
TEL
TE
L
TEL
TEL
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TEL
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TEL
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
P
P
P
P
P
6''
C
O
N
C
S
D
6''
C
O
N
C
S
D
6''
C
O
N
C
S
D
10'' CONC SD 10'' CONC SD 10'' CONC SD
OH
P
OHP OHP
O
H
P
OH
P
OH
P
OH
P
OH
P
OHP OHP
x
x x x
x
x
x
x x
x
T
E
L
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x x x x
SD SD
SD
SD
SD
12'' CONC ST 12'' CONC ST
8'' CONC SS
8'
'
C
O
N
C
S
S
x
x
x
TE
L
TE
L
16
'
'
C
I
W
16
'
'
C
I
W
G
G
G
G
G
G
G
G
G
G
G
G
OH
P
OH
P
OH
P
OH
P
P
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TEL
1
0
'
'
C
O
N
C
S
D
G
G
G
G
G
G
G
G
W
W
10
'
'
C
I
W
16'' CI W
16'
'
C
I
W
16
'
'
C
I
W
10'' CONC SD 10'' CONC SD 10'' CONC SD 10'' CONC SD 10'' CONC SD 10'' CONC SD
6''
P
V
C
S
S
10''
D
I
W
(
5
6
5
)
10'' DI W (565)10'' DI W (565)10'' DI W (565)10'' DI W (565)
10'' DI W (565)
10'' DI W (565)
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
TE
L
TE
L
TE
L
TELTEL
OLYMPIA
NE
1
2
T
H
S
T
R
E
E
T
MONROE
AVE. NE
x
x
x
x
AVE. NE
16'' CI W 16'' CI W
10
'
'
C
O
N
C
S
D
1
0
'
'
C
O
N
C
S
D
1
0
'
'
C
O
N
C
S
D
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
TEL
ABAN TEL ABAN TEL ABAN TEL ABAN TEL ABAN TEL ABAN TEL ABAN TEL ABAN TEL
AB
A
N
T
E
L
TEL TEL
TEL
TEL
TEL
TEL TEL
8''
C
I
P
1
0
'
'
C
I
P
S
D
1
0
'
'
C
I
P
S
D
1
0
'
'
C
I
P
S
D
1
0
'
'
C
I
P
S
D
12'' CI W
12
'
'
C
I
W
12
'
'
C
I
W
OH
P
OH
P
OH
P
8'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS
8'' CONC SS
8'' CONC SS
W
8'
'
A
C
W
(
5
6
5
)
8'
'
A
C
W
(
5
6
5
)
OH
P
OH
P
OHP
OHP OHP OHP OHP
12
'
'
C
I
W
(
4
3
5
)
12
'
'
C
I
W
(
4
3
5
)
16
'
'
D
I
W
(
4
3
5
)
P
PP
OHP OHP OHP
OH
P
OHP OHP OHP
O
H
P
O
H
P
O
H
P
OH
P
OHP
OHP
OH
P
OH
P
OH
P
OH
P
P
OHP OHP OHP
O
H
P
OH
P
OH
P
OH
P
OH
P
O
H
P
O
H
P
OH
P
OH
P
O
H
P
O
H
P
OHP
OHP
OHP
O
H
P
OH
P
OH
P
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TEL
TEL TEL TEL
TE
L
TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TELTELTELTELTEL
TEL TEL TEL TEL
TEL TEL
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
G
G
G
W
4'' IP G
4'' IP G
4'' IP G 4'' IP G
4'' IP G
4'' IP G
8'' DI W (565)
8'' DI W (565)
8'' DI W (565)
4'' IP G
8'' DI W (565)
W
W
W
W
W
W
W
W W
W
W
W
G
4'' IP G
G G G4'' CI W (565)
4'' CI W (565)
10
'
'
C
I
W
(
5
6
5
)
10
'
'
C
I
W
(
5
6
5
)
FO
G
G
G
G G G
SS
SS
SS
SS
SS
S
S
SS
x
x
x
x
x
x
x
xxxxxx
x
x
x
xxxxxxx
x
x
xxx
x
x
x
x
x
x
TE
L
TE
L
TEL
TEL
TEL
TE
L
TE
L
P
P
TE
L
P
TE
L
P
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
TE
L
TE
L
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
COR TELM
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
A
B
N
D
W
A
B
N
D
W
A
B
N
D
W
A
B
N
D
W
A
B
N
D
W
ABND WABND WABND WABND WABND WABND W
AB
N
D
W
AB
N
D
W
A
B
N
D
W
A
B
N
D
W
A
B
N
D
W
6'' CONC SS
4'' SS (ABAN)
21'
17'
87'
15'
20'
15'
CONSTRUCTION ACCESS ROAD CROSS SECTION
EXISTING NATIVE MATERIAL
ATB, PER SECTION 4-05
COMPACT TO 80% OF MAX.
DENSITY, MIN. 4" THICKNESS
CRUSHED SURFACING TOP COURSE (CSTC)
PER SECTION 9-03.9(3) COMPACTED TO 90%
OF MAX. DENSITY, MIN. 6" THICKNESS
15' MIN.
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
PROPOSED STAGING ACCESS
1" = 30'
RELOCATED BANK
OF POWER METERS
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
OW
N
E
R
-
P
R
O
V
I
D
E
D
S
T
A
G
I
N
G
A
R
E
A
SI
T
E
P
L
A
N
KEY NOTES
STABILIZED CONSTRUCTION
ENTRANCE PER COR STD,
PLAN 215.10, TYP.
SILT FENCE PER COR STD.
PLAN 214.00, TYP.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE ADDITIONAL SIZES AND
LOCATIONS NEEDED OF THE STOCKPILE AND CONSTRUCTION STAGING AREAS. THE
LOCATION AND SIZE OF THE STOCKPILE AND STAGING AREA SHOWN HERE REPRESENTS
THE GENERAL EXTENTS OF THE OWNER-PROVIDED STAGING AREA.
IN THE AREA AROUND THE NORTHEAST CORNER OF THE EXISTING 2.0 MG RESERVOIR, THE
CITY HAS NOTED PERSISTENT WET AND SOGGY SOIL CONDITIONS, LIKELY DUE TO
LEAKAGE FROM THE EXISTING RESERVOIRS. THE CONTRACTOR SHALL PROVIDE SITE
STABILIZATION AND DEWATERING AS NECESSARY TO CONSTRUCT THE PROPOSED
IMPROVEMENTS. PER CITY CREWS, EXISTING STRUCTURE SDMH #9023 SEES ESTIMATED
FLOWS OF 30-50 GPM AT ALL TIMES.
THE SOUTHWEST CORNER OF THE SITE, INCLUDING AREAS IN AND AROUND THE PUMP
STATION, ELEVATED TANK, GENERATOR BUILDING, AND CELLULAR EQUIPMENT CABINETS
MUST REMAIN ACCESSIBLE THROUGHOUT CONSTRUCTION AND MAY NOT BE USED FOR
STAGING OR STORAGE. EXCEPT WHERE REQUIRED FOR UTILITY CONSTRUCTION, THE
CONTRACTOR'S ACTIVITIES SHOULD BE CONFINED TO THE AREA NORTH OF THE EXISTING
WATER STORAGE TANKS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING AND
MAKING ARRANGEMENTS FOR ADDITIONAL OFF-SITE STAGING AND STORAGE AS
NECESSARY FOR CONSTRUCTION
PROVIDE STAKE AND WIRE FENCE PER COR STD. PLAN 212.00 OR EQUAL, TYP. ALONG
PERIMETER OF STAGING AREA. WHERE SILT FENCE IS ALSO INSTALLED, LOCATE STAKE
AND WIRE FENCE 3' OUTSIDE OF SILT FENCE.
PROVIDE AND MAINTAIN STABILIZED CONSTRUCTION ENTRANCE PER COR STD. PLAN
215.10 AND CONSTRUCTION ACCESS ROAD PER DETAIL THIS SHEET, THROUGHOUT THE
DURATION OF CONSTRUCTION. CONSTRUCTION ENTRANCE AND ACCESS ROAD MUST BE
LEFT IN PLACE AT PROJECT COMPLETION FOR USE BY FUTURE CONTRACTOR IN
CONSTRUCTION OF NEW RESERVOIR.
1
2
4
2
3
15' WIDE
CONSTRUCTION
ACCESS ROAD
STAGING AREA
4
4
5
1
DO NOT DISTURB
EXISTING TREES, TYP.
OUTLINE OF FUTURE RESERVOIR TO BE
CONSTRUCTED UNDER PHASE 2, N.I.C.
3
5
GENERAL NOTES
1.PROVIDE CATCH BASIN INSERT AT ALL CATCH BASINS HAVING RECTANGULAR
OR CIRCULAR VANED GRATES WITHIN 500' OF CONSTRUCTION ACCESS
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
7
.
D
W
G
SHOWN
G05 5 71
50
A
8
00
A
9
00
A
10
00
A
11
00
A
12
00
A
13
00
A
14
00
A
15
00
A
16
00
A
17
00
A
18
00
A
19
00
A
20
00
A
21
00
A
22
00
A
23
00
A
24
00
A
25
00
A
26
00
A
27
00
A
28
00
A
29
00
A
30
00
A
31
00
A
32
00
A
33
00
A
34
00
A
35
00
A
36
00
A
37
00
A
38
00
A
39
00
A
40
00
A
41
00
A
42
00
A
43
00
A
44
00
A
45
00
A
46
00
A
47
00
A
48
00
A
49
00
A
50
00B10
00B11
00B12
00B13
00B14
00B15
00B16
00B17
00B18
00B19
STA. 10+00.00A, 0.0' ,
STA. 37+23.18A,
STATION BASELINE INTERSECTION
POINT
B-STATION BASELINE 10+00.00B
STA. 27+26.10A, 0.00' ,
STA. 24+68.67A, 0.00' ,
STA. 17+78.60A, 0.00' ,STA. 30+25.46A, 0.00' ,
STA. 35+44.24A, 0.00' ,STA. 37+23.18A, 0.00' ,
STA. 19+00.00B,
STATION BASELINE END
N. 187300.64
E. 1308933.15
STA. 50+00.00A,
STATION BASELINE END
N. 186356.33
E. 1310189.10
L2 L3 L4 L5 L6 L7 L8
L9
L1
STA. 8+50.00A,
STATION BASELINE
BEGINNING
N. 186453.90
E. 1306040.40
SURVEY CONTROL POINT TABLE
POINT NO.DESC.ELEV.NORTHING EASTING
SURVEY CONTROL POINT TABLE
POINT NO.DESC.ELEV.NORTHING EASTING
SURVEY CONTROL POINT TABLE
POINT NO.DESC.ELEV.NORTHING EASTING
STATION BASELINE "A" - NE 12TH ST
NUMBER
L1
L2
L3
L4
L5
L6
L7
L8
START N,E
(186453.90,1306040.40)
(186452.87,1306190.40)
(186438.74,1306968.87)
(186426.29,1307658.83)
(186421.70,1307916.22)
(186416.33,1308215.53)
(186406.94,1308734.22)
(186400.86,1308913.06)
END N,E
(186452.87,1306190.40)
(186438.74,1306968.87)
(186426.29,1307658.83)
(186421.70,1307916.22)
(186416.33,1308215.53)
(186406.94,1308734.22)
(186400.86,1308913.06)
(186356.33,1310189.10)
START STA
8+50.00
10+00.00
17+78.60
24+68.67
27+26.10
30+25.46
35+44.24
37+23.18
END STA
10+00.00
17+78.60
24+68.67
27+26.10
30+25.46
35+44.24
37+23.18
50+00.00
LENGTH
150.00
778.60
690.07
257.43
299.36
518.77
178.95
1276.82
RADIUS
STATION BASELINE "B" - MONROE AVE NE
NUMBER
L9
START N,E
(186400.86,1308913.06)
END N,E
(187300.64,1308933.15)
START STA
10+00.00
END STA
19+00.00
LENGTH
900.00
RADIUS
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
S
T
A
T
I
O
N
.
D
W
G
SHOWN
G06 6 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
ST
A
T
I
O
N
B
A
S
E
L
I
N
E
D
E
F
I
N
I
T
I
O
N
A
N
D
SU
R
V
E
Y
C
O
N
T
R
O
L
SURVEY CONTROL AND STATION BASELINE DEFINITION
GENERAL NOTES
LEGAL DESCRIPTION
BASIS OF BEARING
”
SURVEY NOTES
NE 12TH ST HA
R
R
I
N
G
T
O
N
A
V
E
N
E
ED
M
O
N
D
S
A
V
E
N
E
JE
F
F
E
R
S
O
N
A
V
E
N
E
KI
R
K
L
A
N
D
A
V
E
N
E
SU
N
S
E
T
B
L
V
D
N
E
MO
N
R
O
E
A
V
E
N
E
LY
N
N
W
O
O
D
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
PI
E
R
C
E
A
V
E
N
E
QU
E
E
N
A
V
E
N
E
NE 12TH ST
8'' CP SS
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
2601 & 2603 NE 12TH ST
TPN: 7227801335
1" LATERAL 3/4" METER
ACCNT #003066
NA
TPN: 0923059102
NO METER
2527 NE 12TH ST
TPN: 0923059062
1" LATERAL 3/4"
METER ACCNT
#140025
1140 EDMONDS AVE NE
TPN: 0923059061
METER ON EDMONDS
1190 EDMONDS PL NE
TPN: 2270000020
1194 EDMONDS PL NE
TPN: 2270000010
2430 NE 12TH ST
TPN: 2309200010
JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
ED
M
O
N
D
S
A
V
E
N
E
NE 12TH STREET
P P P P
P
P P P P P P P PPP
8'' AC W (435)
16
'
'
D
I
W
(
4
3
5
)
8'
'
C
I
W
(
4
3
5
)
8'
'
C
I
W
(
4
3
5
)
8'' AC W (435)12'' AC W (435)12'' AC W (435)12'' AC W (435)12'' AC W (435)12'' AC W (435)
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
W
16
'
'
D
I
W
(
4
3
5
)
16
'
'
D
I
W
(
4
3
5
)
W
P
P
P
P P P P P
P P P P PPPPPP
P P P P PPPPPP
P
P
P
P
P
P
P
P
P
P
W
T
E
L
T
E
L
TE
L
TEL
TE
L
TE
L
TEL TEL TEL TEL
TEL TEL TEL TEL
TE
L
TE
L
TEL TEL TEL TEL TEL TEL TEL TEL
TE
L
TE
L
TEL TEL TEL TEL
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
CO
R
T
E
L
M
G
G G
6'' IP G 6'' IP G 6'' IP G
G G
G
G
18
'
'
C
O
N
C
S
T
18
'
'
C
O
N
C
S
T
8'' CONC ST
8
'
'
C
O
N
C
S
T
12'' CONC ST
36'' CPEP ST
10''
C
O
N
C
S
T
12'' ST (ABAN)12'' ST (ABAN)
12'' ST (ABAN)12'' ST (ABAN)36'' CMP ST
36'' CMP ST
36'' CMP ST
ST
36'' CMP ST
G
G
x x x x x x x x x x x x x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x x x
x x
x
x
x x x x x x x x x x x
x
x
x x x x x x x x x x
x
x
x
x
G
G
00
A
10
00
A
11
00
A
12
00
A
13
00
A
14
PH1
PH1A
PH2
PH2A
PH G1 PH P1
\\\\\\\\\\\\\\\\\\\\\\
P0
1
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
P0
1
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
PPH2
PPH3
GPH4
GPH5
GPH6
GPH7
GPH8
PPH9
PPH11
PREPARATION KEYNOTES
PREPARATION GENERAL NOTES
PH#
PH#HMA UTILITY DIRECTION DEPTH TO TOP
”
”
”
”
POTHOLE NOTES
PSE POTHOLE INVESTIGATION NOTES
PH#HMA UTILITY DIRECTION DEPTH TO TOP
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
P01 P02 P03 P04 P05 P06 P07 P08
P1
1
P1
0
P09
8'' CP SS
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
2601 & 2603 NE 12TH ST
TPN: 7227801335
1" LATERAL 3/4" METER
ACCNT #003066
NA
TPN: 0923059102
NO METER
2527 NE 12TH ST
TPN: 0923059062
1" LATERAL 3/4"
METER ACCNT
#140025
1140 EDMONDS AVE NE
TPN: 0923059061
METER ON EDMONDS
1190 EDMONDS PL NE
TPN: 2270000020
1194 EDMONDS PL NE
TPN: 2270000010
2430 NE 12TH ST
TPN: 2309200010
JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
ED
M
O
N
D
S
A
V
E
N
E
NE 12TH STREET
P P P P
P
P P P P P P P PPP
8'' AC W (435)
16
'
'
D
I
W
(
4
3
5
)
8'
'
C
I
W
(
4
3
5
)
8'
'
C
I
W
(
4
3
5
)
8'' AC W (435)12'' AC W (435)12'' AC W (435)12'' AC W (435)12'' AC W (435)12'' AC W (435)
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
W
16
'
'
D
I
W
(
4
3
5
)
16
'
'
D
I
W
(
4
3
5
)
W
P
P
P
P P P P P
P P P P PPPPPP
P P P P PPPPPP
P
P
P
P
P
P
P
P
P
P
W
T
E
L
T
E
L
TE
L
TEL
TE
L
TE
L
TEL TEL TEL TEL
TEL TEL TEL TEL
TE
L
TE
L
TEL TEL TEL TEL TEL TEL TEL TEL
TE
L
TE
L
TEL TEL TEL TEL
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
CO
R
T
E
L
M
G
G G
6'' IP G 6'' IP G 6'' IP G
G G
G
G
18
'
'
C
O
N
C
S
T
18
'
'
C
O
N
C
S
T
8'' CONC ST
8
'
'
C
O
N
C
S
T
12'' CONC ST
36'' CPEP ST
10''
C
O
N
C
S
T
12'' ST (ABAN)12'' ST (ABAN)
12'' ST (ABAN)12'' ST (ABAN)36'' CMP ST
36'' CMP ST
36'' CMP ST
ST
36'' CMP ST
G
G
x x x x x x x x x x x x x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x x x
x x
x
x
x x x x x x x x x x x
x
x
x
x x x x x x x x x
x
x
x
x
G
G
00
A
10
00
A
11
00
A
12
00
A
13
00
A
14
12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)
12
'
'
D
I
W
(
5
6
5
)
FO FO FO FO FO FO FO FO FO FO FO FO FO
FO
\
\
\
\
\
\
PH1
PH1A
PH2
PH2A
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\PH G1 PH P1
\\\\\\\\\\\\\\\\\\\\\\
\
\
\
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXXXXXXXXXX X X X X X X X X X X X X X X
P0
1
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
P0
1
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
PPH2
PPH3
GPH4
GPH5
GPH6
GPH7
GPH8
PPH9
PPH11
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
2
.
D
W
G
SHOWN
P01 7 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EXISTING PLAN VIEW
EX
I
S
T
I
N
G
,
D
E
M
O
L
I
T
I
O
N
,
A
N
D
P
R
E
P
A
R
A
T
I
O
N
PL
A
N
0
1
NE
1
2
T
H
S
T
-
E
D
M
O
N
D
S
A
V
E
T
O
H
A
R
R
I
N
G
T
O
N
A
V
E
DEMOLITION AND PREPARATION PLAN VIEW
8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS
8'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
4
'
'
C
O
N
C
S
S
SS SS
SS
SS
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
1174 HARRINGTON AVE NE
TPN: 7227801675
METER SERVICE ON HARRINGTON
1177 HARRINGTON AVE NE
TPN: 7227801355
METER SERVICE ON HARRINGTON
2613 & 2615 NE 12TH ST
TPN: 7227801345
1" LATERAL 3/4" METER
ACCNT #003069
2607 & 2609 NE 12TH ST
TPN: 7227801340
1" LATERAL 3/4" METER
ACCNT #003067
JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
NA
TPN: 7227801860
METER SERVICE ON HARRINGTON
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
NE 12TH STREET
P P P
P P P
P
P
P
PPPPPPP
P
P
12'' AC W (435)12'' AC W (435)
16'' DI W (435)16'' DI W (435)16'' DI W (435)
12'' AC W (435)
12'' AC W (435)
W
P P P P P P
P
P P P P
P
P
P P P P P
P
P P P P P P
P P P P P P P
12
A
C
W
(
A
B
A
N
)
16'' DI W (435)16'' DI W (435)
8'' AC W (ABAN)8'' AC W (ABAN)
TEL TEL TEL
TE
L
TE
L
TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL
T
E
L
T
E
L
TE
L
TE
L
T
E
L
T
E
L
TE
L
TE
L
T
E
L
TEL TEL TEL
TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL
6'' IP G
GG
G
GG
6'' IP G 6'' IP G 6'' IP G 6'' IP G
8'
'
C
I
W
(
5
6
5
)
G
G
G
G
12'
'
D
I
W
(
5
6
5
)
8'' CI W (565)8'' CI W (565)
12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
8'
'
C
O
N
C
S
T
18
'
'
C
P
P
S
T
36'' CMP ST 36'' CMP ST
12'' ST 12'' ST
36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST
12
'
'
A
D
S
S
T
1
2
'
'
A
D
S
S
T
8''
C
O
N
C
S
T
x
x x x x x x x x x x x x x x x x x x x
x
x
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
x
x
x
TEL TEL TEL TEL TEL TEL TEL TEL TEL
8'
'
D
I
W
G
00
A
15
00
A
16
00
A
17
00
A
18
00
A
19
PH4
PH5
PH G2PH P2 PH P3
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
P0
2
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
P0
2
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
P0
2
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
P0
2
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
PPH12
PPH13 GPH14 PPH15
PPH17
GPH18
PPH20
PREPARATION KEYNOTES
PREPARATION GENERAL NOTES
PH#
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
P01 P02 P03 P04 P05 P06 P07 P08
P1
1
P1
0
P09
8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS
8'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
4
'
'
C
O
N
C
S
S
SS SS
SS
SS
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
1174 HARRINGTON AVE NE
TPN: 7227801675
METER SERVICE ON HARRINGTON
1177 HARRINGTON AVE NE
TPN: 7227801355
METER SERVICE ON HARRINGTON
2613 & 2615 NE 12TH ST
TPN: 7227801345
1" LATERAL 3/4" METER
ACCNT #003069
2607 & 2609 NE 12TH ST
TPN: 7227801340
1" LATERAL 3/4" METER
ACCNT #003067
JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
NA
TPN: 7227801860
METER SERVICE ON HARRINGTON
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
NE 12TH STREET
P P P
P P P
P
P
P
PPPPPPP
P
P
12'' AC W (435)12'' AC W (435)
16'' DI W (435)16'' DI W (435)16'' DI W (435)
12'' AC W (435)
12'' AC W (435)
W
P P P P P P
P
P P P P
P
P
P P P P P
P
P P P P P P
P P P P P P P
12
A
C
W
(
A
B
A
N
)
16'' DI W (435)16'' DI W (435)
8'' AC W (ABAN)8'' AC W (ABAN)
TEL TEL TEL
TE
L
T
E
L
TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL
T
E
L
T
E
L
TE
L
TE
L
T
E
L
T
E
L
TE
L
TE
L
T
E
L
TEL TEL TEL
TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL
6'' IP G
GG
G
GG
6'' IP G 6'' IP G 6'' IP G 6'' IP G
8'
'
C
I
W
(
5
6
5
)
G
G
G
G
12'
'
D
I
W
(
5
6
5
)
8'' CI W (565)8'' CI W (565)
12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
8'
'
C
O
N
C
S
T
18
'
'
C
P
P
S
T
36'' CMP ST 36'' CMP ST
12'' ST 12'' ST
36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST
12
'
'
A
D
S
S
T
1
2
'
'
A
D
S
S
T
8''
C
O
N
C
S
T
x
x x x x x x x x x x x x x x x x x x x
x
x
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
x
x
x
TEL TEL TEL TEL TEL TEL TEL TEL TEL
8'
'
D
I
W
G
00
A
15
00
A
16
00
A
17
00
A
18
00
A
19
12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
PH4
PH5
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
PH G2PH P2 PH P3
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\
\\\\
\
\\\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
P0
2
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
P0
2
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
P0
2
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
P0
2
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
X
XX
XXX
PPH12
PPH13 GPH14 PPH15
PPH17
GPH18
PPH20
PH#HMA UTILITY DIRECTION DEPTH TO TOP
”
”
”
POTHOLE NOTES
PSE POTHOLE INVESTIGATION NOTES
PH#HMA UTILITY DIRECTION DEPTH TO TOP
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
2
.
D
W
G
SHOWN
P02 8 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EXISTING PLAN VIEW
EX
I
S
T
I
N
G
,
D
E
M
O
L
I
T
I
O
N
,
A
N
D
P
R
E
P
A
R
A
T
I
O
N
PL
A
N
0
2
NE
1
2
T
H
S
T
-
E
D
M
O
N
D
S
A
V
E
T
O
H
A
R
R
I
N
G
T
O
N
A
V
E
DEMOLITION AND PREPARATION PLAN VIEW
8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SS SS
SS SS
4
'
'
C
O
N
C
S
S
SS
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SS
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SS
1175 HARRINGTON PL NE
TPN: 3122000000
2825 NE 12TH ST
TPN: 7227802045
2801 NE 12TH ST
TPN: 7227801680
1" METER ACCNT #003069
2810 NE 12TH ST
TPN: 7227801685
EXISTING 3/4" METER ACCNT
2902 NE 12TH ST
TPN: 7227802040
2908 NE 12TH ST
TPN: 7227801776
EXISTING 1-1/2" METER
ACCNT #3168-000
HA
R
R
I
N
G
T
O
N
P
L
N
E
NE 12TH STREET
PP
P
P
P P P P
8''
C
I
W
(
4
3
5
)
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
P P
P
P P P P PPPPP P P P P P P PP
8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)
TEL
TE
L
TE
L
TEL
TEL
T
E
L
TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TELTELTELTELTELTEL
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL
TE
L
TE
L
TE
L
TEL TEL TEL TEL
8'' CI W (565)
W
W
8'' CI W (565)
8'
'
D
I
W
(
5
6
5
)
4''
I
P
G
6'' IP G 6'' IP G 6'' IP G 6'' IP G 6'' IP G 6'' IP G6'' IP G6'' IP G
G
8'' CI W (565)8'' CI W (565)
36'' CMP ST 36'' CMP ST
12'' ST 12'' ST 12'' ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST
12
'
'
C
O
N
C
S
T
36'' CMP ST
12'' ST (ABAN)
6'
'
C
O
N
C
S
T
x
x
x
x
W
P P P
P
P
PP
P
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
(
5
6
5
)
8'' CI W (565)8'' CI W (565)
2'' STL G (ABND)2'' STL G (ABND)
00
A
19
00
A
20
00
A
21
00
A
22
00
A
23
PH6
PH7
PH G3
PH P4 PH P5
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
P0
3
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
P0
3
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
P0
3
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
P0
3
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
PPH21
GPH22
GPH23A GPH24
GPH25
PPH26
GPH27
GPH23B
PREPARATION KEYNOTES
PREPARATION GENERAL NOTES
PH#
PH#HMA UTILITY DIRECTION DEPTH TO TOP
”
”
”
POTHOLE NOTES
PSE POTHOLE INVESTIGATION NOTES
PH#HMA UTILITY DIRECTION DEPTH TO TOP
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
P01 P02 P03 P04 P05 P06 P07 P08
P1
1
P1
0
P09
8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SS SS
SS SS
4
'
'
C
O
N
C
S
S
SS
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SS
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SS
1175 HARRINGTON PL NE
TPN: 3122000000
2825 NE 12TH ST
TPN: 7227802045
2801 NE 12TH ST
TPN: 7227801680
1" METER ACCNT #003069
2810 NE 12TH ST
TPN: 7227801685
EXISTING 3/4" METER ACCNT
2902 NE 12TH ST
TPN: 7227802040
2908 NE 12TH ST
TPN: 7227801776
EXISTING 1-1/2" METER
ACCNT #3168-000
HA
R
R
I
N
G
T
O
N
P
L
N
E
NE 12TH STREET
PP
P
P
P P P P
8''
C
I
W
(
4
3
5
)
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
P P
P
P P P P PPPPP P P P P P P PP
8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)
TEL
TE
L
TE
L
TEL
TEL
T
E
L
TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TELTELTELTELTELTEL
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL
TE
L
TE
L
TE
L
TEL TEL TEL TEL
8'' CI W (565)
W
W
8'' CI W (565)
8'
'
D
I
W
(
5
6
5
)
4''
I
P
G
6'' IP G 6'' IP G 6'' IP G 6'' IP G 6'' IP G 6'' IP G6'' IP G6'' IP G
G
8'' CI W (565)8'' CI W (565)
36'' CMP ST 36'' CMP ST
12'' ST 12'' ST 12'' ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST
12
'
'
C
O
N
C
S
T
36'' CMP ST
12'' ST (ABAN)
6'
'
C
O
N
C
S
T
x
x
x
x
W
P P P
P
P
PP
P
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
(
5
6
5
)
8'' CI W (565)8'' CI W (565)
2'' STL G (ABND)2'' STL G (ABND)
00
A
19
00
A
20
00
A
21
00
A
22
00
A
23
12'' DI W (565)12'' DI W (565)12'' DI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
PH6
PH7
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH G3
PH P4 PH P5
X
X
X
X
X
X
X
X\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\X X X X X X X X X X X X X X X X X X
\
\
\
X
X
X
X
X
X
P0
3
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
P0
3
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
P0
3
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
P0
3
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
XX
X
X
PPH21
GPH22
GPH23A GPH24
GPH25
PPH26
GPH27
GPH23B
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
2
.
D
W
G
SHOWN
P03 9 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EXISTING PLAN VIEW
EX
I
S
T
I
N
G
,
D
E
M
O
L
I
T
I
O
N
,
A
N
D
P
R
E
P
A
R
A
T
I
O
N
PL
A
N
0
3
NE
1
2
T
H
S
T
-
H
A
R
R
I
N
G
T
O
N
A
V
E
T
O
K
I
R
K
L
A
N
D
A
V
E
DEMOLITION AND PREPARATION PLAN VIEW
8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS
8'
'
S
S
(
A
B
A
N
)
8'
'
S
S
(
A
B
A
N
)
8'
'
S
S
(
A
B
A
N
)
8'
'
P
V
C
S
S
8'
'
S
S
8'
'
S
S
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SSSSSSSS
FIRE STATION #12
1209 KIRKLAND AVE NE
TPN: 7227801450
4" DCDA W/ 3/4" METER
ACCNT #61583-001
1-1/2" IRR METER ACCNT
#61583-002
2" DOM METER ACCNT
#61583-000
1171 KIRKLAND AVE NE
TPN: 7227801406
975 HARRINGTON PL NE
TPN: 7227801405
3116 SUNSET BLVD NE
TPN: 0423059095
3002 NE SUNSET BLVD
TPN: 7227800285
KI
R
K
L
A
N
D
A
V
E
N
E
JE
F
F
E
R
S
O
N
A
V
E
N
E
NE 12TH STREET
P P
P
P
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
P P P
P
P
PPPP
P
16'' DI W (435)16'' DI W (435)
OH
P
P
P P
P P PP P
8'' AC W (ABAN)8'' AC W (ABAN)
8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)
TE
L
TE
L
TEL TEL TELTELTELTELTELTELTEL
TEL
TE
L
TEL TEL TEL
TE
L
TEL TEL TEL TEL
TE
L
TE
L
TEL TEL TELTELTELTELTELTELTELTELTELTELTEL
TEL TEL TEL
TEL TEL
TE
L
TE
L
TE
L
TE
L
TEL TEL
TEL TEL
8'' CI W (565)8'' CI W (565)8'' CI W (565)8'' CI W (565)
W W
8'
'
D
I
W
(
5
6
5
)
4'' IP G4'' IP G 4'' IP G
4'' IP G 4'' IP G 4'' IP G
G
2'
'
I
P
G
2'
'
I
P
G
4'' IP G
6'' IP G
G
FO FO FO
12'' ST (ABAN)12'' ST (ABAN)
S
D
36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST
6
'
'
C
M
P
S
T
SD
S
D
SD
SD
6''
P
V
C
S
T
6
'
'
C
O
N
C
S
T
18
'
'
C
M
P
S
T
12'' ADS ST
12'' CONC ST 12'' CONC ST
12
S
T
12
S
T
x
x
x
10
'
'
S
T
L
W
(
A
B
N
)
10
'
'
C
I
(
5
6
5
)
W
P
P
P
P
P P P P
P
P
P
CO
R
T
E
L
M
CO
R
T
E
L
M
COR TELM COR TELM
P P P P P P P P
12
'
'
D
I
W
6'
'
C
I
W
(
A
B
A
N
)
18
'
'
D
I
S
T
1
2
'
'
D
I
S
T
12'
'
S
T
12
'
'
S
T
12
'
'
S
T
12
'
'
S
T
6'
'
C
O
N
C
S
S
(
A
B
A
N
)
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
WS
PP PP
10
'
'
C
I
W
(
5
6
5
)
10
'
'
C
I
W
(
5
6
5
)
00
A
24
00
A
25
00
A
26
00
A
27
00
A
28
PH9
PH10
PH11
PH12
PH12A
PH G4 PH G5
PH P6
P0
4
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
P0
4
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
P0
4
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
P0
4
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
PPH29 GPH30 PPH31 PPH32
GPH34
PPH35
PPH37
GPH38
PPH39
PPH40
PREPARATION KEYNOTES
PH#
PH#HMA UTILITY DIRECTION DEPTH TO TOP
”
”
”
POTHOLE NOTES
PSE POTHOLE INVESTIGATION NOTES
PH#HMA UTILITY DIRECTION DEPTH TO TOP
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
P01 P02 P03 P04 P05 P06 P07 P08
P1
1
P1
0
P09
8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS
8'
'
S
S
(
A
B
A
N
)
8'
'
S
S
(
A
B
A
N
)
8'
'
S
S
(
A
B
A
N
)
8'
'
P
V
C
S
S
8'
'
S
S
8'
'
S
S
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SSSSSSSS
FIRE STATION #12
1209 KIRKLAND AVE NE
TPN: 7227801450
4" DCDA W/ 3/4" METER
ACCNT #61583-001
1-1/2" IRR METER ACCNT
#61583-002
2" DOM METER ACCNT
#61583-000
1171 KIRKLAND AVE NE
TPN: 7227801406
975 HARRINGTON PL NE
TPN: 7227801405
3116 SUNSET BLVD NE
TPN: 0423059095
3002 NE SUNSET BLVD
TPN: 7227800285
KI
R
K
L
A
N
D
A
V
E
N
E
JE
F
F
E
R
S
O
N
A
V
E
N
E
NE 12TH STREET
P P
P
P
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
P P P
P
P
PPPP
P
16'' DI W (435)16'' DI W (435)
OH
P
P
P P
P P PP P
8'' AC W (ABAN)8'' AC W (ABAN)
8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)
TE
L
TE
L
TEL TEL TELTELTELTELTELTELTEL
TEL
TE
L
TEL TEL TEL
TE
L
TEL TEL TEL TEL
TE
L
TE
L
TEL TEL TELTELTELTELTELTELTELTELTELTELTEL
TEL TEL TEL
TEL TEL
TE
L
TE
L
TE
L
TE
L
TEL TEL
TEL TEL
8'' CI W (565)8'' CI W (565)8'' CI W (565)8'' CI W (565)
W W
8'
'
D
I
W
(
5
6
5
)
4'' IP G4'' IP G 4'' IP G
4'' IP G 4'' IP G 4'' IP G
G
2'
'
I
P
G
2'
'
I
P
G
4'' IP G
6'' IP G
G
FO FO FO
12'' ST (ABAN)12'' ST (ABAN)
S
D
36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST
6
'
'
C
M
P
S
T
SD
S
D
SD
SD
6''
P
V
C
S
T
6
'
'
C
O
N
C
S
T
18
'
'
C
M
P
S
T
12'' ADS ST
12'' CONC ST 12'' CONC ST
12
S
T
12
S
T
x
x
x
10
'
'
S
T
L
W
(
A
B
N
)
10
'
'
C
I
(
5
6
5
)
W
P
P
P
P
P P P P
P
P
P
CO
R
T
E
L
M
CO
R
T
E
L
M
COR TELM COR TELM
P P P P P P P P
12
'
'
D
I
W
6'
'
C
I
W
(
A
B
A
N
)
18
'
'
D
I
S
T
1
2
'
'
D
I
S
T
12'
'
S
T
12
'
'
S
T
12
'
'
S
T
12
'
'
S
T
6'
'
C
O
N
C
S
S
(
A
B
A
N
)
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
WS
PP PP
10
'
'
C
I
W
(
5
6
5
)
10
'
'
C
I
W
(
5
6
5
)
00
A
24
00
A
25
00
A
26
00
A
27
00
A
28
12'' DI W (565)12'' DI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
PH9
PH10
PH11
PH12
PH12A
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\
\
\
\
\
\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH G4 PH G5
PH P6
X
X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X
\
\
\
\
\
\
X
X
X
X
P0
4
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
P0
4
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
P0
4
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
P0
4
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
X
X
X
X
X
X
X
X
X
X
X
X
X
X
\\\
PPH29 GPH30 PPH31 PPH32
GPH34
PPH35
PPH37
GPH38
PPH39
PPH40
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
2
.
D
W
G
SHOWN
P04 10 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EXISTING PLAN VIEW
EX
I
S
T
I
N
G
,
D
E
M
O
L
I
T
I
O
N
,
A
N
D
P
R
E
P
A
R
A
T
I
O
N
PL
A
N
0
4
NE
1
2
T
H
S
T
-
H
A
R
R
I
N
G
T
O
N
A
V
E
T
O
K
I
R
K
L
A
N
D
A
V
E
DEMOLITION AND PREPARATION PLAN VIEW NOTE: PREPARATION GENERAL NOTES NOT
SHOWN ON THIS SHEET. SEE DWG NO. P01 FOR
PREPARATION GENERAL NOTES.
8'' CP SS 8'' CP SS 8'' CP SS
8
'
'
C
P
S
S
8
'
'
C
P
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
8''
S
S
8''
S
S
8''
C
P
S
S
8''
C
P
S
S
SS SS
NA
TPN: 7227900018
3011 NE SUNSET BLVD
TPN: 7227900019
METER SERVICE ON NE
SUNSET BLVD
NA
TPN: 722790UNKN
3123 NE SUNSET BLVD
TPN: 0423059155
1" METER ACCNT
#157203-000
1" IRR METER ACCNT
#57203
3116 NE SUNSET BLVD
TPN: 0423059095
3/4" IRR METER ACCNT
#19835-000
3002 NE SUNSET BLVD
TPN: 7227800285
METER SERVICE ON
NE SUNSET BLVD
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
P
P
16'' DI W (435)16'' DI W (435)
P P
10'' CI W (435
)
16'' DI W (435)16'' DI W (435)
P P P P
P
P
P
16'' DI W (435)
10
'
'
C
I
W
(
4
3
5
)
P
P P P P P P P P P PPPPPPPPPPPPP
P P PP
P
P
P
P
P
P
P
P
P
P
10'' CI W (435)
8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)
8'
'
A
C
W
(
A
B
A
N
)
6'
'
C
I
W
(
4
3
5
)
TEL TEL TEL
TEL TEL TEL TEL TEL
TE
L
TEL TEL TEL TEL
TEL
TEL TEL TEL TEL
TEL
TEL TE
L
TE
L
TEL TEL
TEL
T
E
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
4'' STL W (ABN)4'' STL W (ABN)4'' STL W (ABN)
10'' CI W (565)10'' CI W (565)10'' CI W (565)
W
2'' IP G 2'' IP G
4''
I
P
G
4''
I
P
G
G
4'' IP G 4'' IP G 4'' IP G
G
G
G
G
12
'
'
D
I
W
(
5
6
5
)
10'' CI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO
FO
FO
FO FO FO FO FO FO FO FO FO
12'' CONC ST 12'' CONC ST 12'' CONC ST
18
'
'
C
O
N
C
S
T
18
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
SD
12
'
'
C
O
N
C
S
T
1
2
'
'
S
T
4''
C
I
W
(
A
B
A
N
)
4''
C
I
W
(
A
B
A
N
)
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
(
5
6
5
)
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
G
G
G
12'' CONC ST
12'' CONC ST
12'' CONC ST
12'' CONC ST
00
A
29
00
A
30
00
A
31
00
A
32
PH13
PH14
PH G6
PH G7
PH G8
PH G9
PH G10
PH P7
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
P0
5
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
P0
5
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
P0
5
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
P0
5
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
PPH43
PPH44
GPH45
GPH47
GPH48
PPH46
PPH49
GPH50
GPH51
PPH52
PPH53
PPH56
PPH54
PPH55
PPH57
PPH59
PPH60
PREPARATION KEYNOTES
PH#
PH#HMA UTILITY DIRECTION DEPTH TO TOP
”
POTHOLE NOTES
PSE POTHOLE INVESTIGATION NOTES
PH#HMA UTILITY DIRECTION DEPTH TO TOP
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
P01 P02 P03 P04 P05 P06 P07 P08
P1
1
P1
0
P09
8'' CP SS 8'' CP SS 8'' CP SS
8
'
'
C
P
S
S
8
'
'
C
P
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
8''
S
S
8''
S
S
8''
C
P
S
S
8''
C
P
S
S
SS SS
NA
TPN: 7227900018
3011 NE SUNSET BLVD
TPN: 7227900019
METER SERVICE ON NE
SUNSET BLVD
NA
TPN: 722790UNKN
3123 NE SUNSET BLVD
TPN: 0423059155
1" METER ACCNT
#157203-000
1" IRR METER ACCNT
#57203
3116 NE SUNSET BLVD
TPN: 0423059095
3/4" IRR METER ACCNT
#19835-000
3002 NE SUNSET BLVD
TPN: 7227800285
METER SERVICE ON
NE SUNSET BLVD
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
P
P
16'' DI W (435)16'' DI W (435)
P P
10'' CI W (435
)
16'' DI W (435)16'' DI W (435)
P P P P
P
P
P
16'' DI W (435)
10
'
'
C
I
W
(
4
3
5
)
P
P P P P P P P P P PPPPPPPPPPPPP
P P PP
P
P
P
P
P
P
P
P
P
P
10'' CI W (435)
8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)
8'
'
A
C
W
(
A
B
A
N
)
6'
'
C
I
W
(
4
3
5
)
TEL TEL TEL
TEL TEL TEL TEL TEL
TE
L
TEL TEL TEL TEL
TEL
TEL TEL TEL TEL
TEL
TEL TE
L
TE
L
TEL TEL
TEL
T
E
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
4'' STL W (ABN)4'' STL W (ABN)4'' STL W (ABN)
10'' CI W (565)10'' CI W (565)10'' CI W (565)
W
2'' IP G 2'' IP G
4''
I
P
G
4''
I
P
G
G
4'' IP G 4'' IP G 4'' IP G
G
G
G
G
12
'
'
D
I
W
(
5
6
5
)
10'' CI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO
FO
FO
FO FO FO FO FO FO FO FO FO
12'' CONC ST 12'' CONC ST 12'' CONC ST
18
'
'
C
O
N
C
S
T
18
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
SD
12
'
'
C
O
N
C
S
T
1
2
'
'
S
T
4''
C
I
W
(
A
B
A
N
)
4''
C
I
W
(
A
B
A
N
)
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
(
5
6
5
)
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
G
G
G
12'' CONC ST
12'' CONC ST
12'' CONC ST
12'' CONC ST
00
A
29
00
A
30
00
A
31
00
A
32
12'' DI W (565)
16
'
'
D
I
W
(
4
3
5
)
12'' RJ DI W (565)12'' DI W (565)
16
'
'
D
I
W
(
4
3
5
)
PIPE SHALL NOT BE INSTALLED FURTHER
EAST THAN THIS POINT PRIOR TO PRESSURE
TESTING, DISENFECTION, PIGGING AND CITY
APPROVAL. SEE DWG NO. WC06.
FO FO FO FO FO FO FO FO FO FO FO FO FO
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
X
X
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH13
PH14
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
PH G6
PH G7
PH G8
PH G9
PH G10
PH P7
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X
P0
5
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
P0
5
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
P0
5
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
P0
5
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
X X X
XXX
XX
X
XX
\
\
\
\
\
X
PPH43
PPH44
GPH45
GPH47
GPH48
PPH46
PPH49
GPH50
GPH51
PPH52
PPH53
PPH56
PPH54
PPH55
PPH57
PPH59
PPH60
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
2
.
D
W
G
SHOWN
P05 11 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EXISTING PLAN VIEW
EX
I
S
T
I
N
G
,
D
E
M
O
L
I
T
I
O
N
,
A
N
D
P
R
E
P
A
R
A
T
I
O
N
PL
A
N
0
5
NE
1
2
T
H
S
T
-
K
I
R
K
L
A
N
D
A
V
E
T
O
M
O
N
R
O
E
A
V
E
DEMOLITION AND PREPARATION PLAN VIEW NOTE: PREPARATION GENERAL NOTES NOT
SHOWN ON THIS SHEET. SEE DWG NO. P01 FOR
PREPARATION GENERAL NOTES.
8'
'
P
V
C
S
S
8'' PVC SS
8'' PVC SS
8'' CLAY SS
8'' CLAY SS
8'' CLAY SS
8'' CLAY SS
8'' CLAY SS
8
'
'
P
V
C
S
S
1170 MONROE AVE NE
TPN: 0923059170
3233 NE 12TH ST
TPN: 7801300000
METER SERVICES ON
LYNNWOODTPN: 7227900018
3316 NE 12TH ST
TPN: 7736100015
3232 NE 12TH ST
TPN: 0423059316
3224 NE 12TH ST
TPN: 0423059169
3/4" METER ACCNT
#7720-000
3218 NE 12TH ST
TPN: 0423059182
1-1/2" METER
ACCNT #17721-00
LY
N
N
W
O
O
D
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
NE 12TH ST
P
P
P
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
OHP OHP
OH
P
OH
P
OH
P
OH
P
O
H
P
OHP OHP OHP OHP OHP
OHP
O
H
P
O
H
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
P
P
10'' CI W (435)10'' CI W (435)10'' CI W (435)10'' CI W (435)
10'' CI W (435)
TEL
TELTELTEL
TEL TEL TEL TEL TEL TEL
TEL
TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL
TE
L
TE
L
T
E
L
TE
L
TE
L
TE
L
4'' STL W (ABN)
10
'
'
D
I
W
(
5
6
5
)
10
'
'
D
I
W
(
5
6
5
)
W
W
6'' DI W (565)6'' DI W (565)
8'
'
C
I
W
(
5
6
5
)
4'' IP G
G
4'' IP G
2'' IP G 2'' IP G 2'' IP G 2'' IP G 2'' IP G
2'
'
I
P
G
G
G
4'
'
C
I
W
(
5
6
5
)
10'' CI W (565)10'' CI W (565)10'' CI W (565)10'' CI W (565)10'' CI W (565)10'' CI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
1
2
'
'
C
M
P
S
T
12'' ST 12'' ST
6''
C
O
N
C
S
T
12'' CONC ST (ABAN)
12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
8'
'
C
M
P
S
T
8
'
'
C
M
P
S
T
FO
x
x
x
x
x
xxxxxxxxxxxx
x
x
x
x
xxxxxxxx
x x x
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
CO
R
T
E
L
M
COR TELM COR TELM
ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W
4''
C
O
N
C
S
S
4''
C
O
N
C
S
S
4''
C
O
N
C
S
S
4''
C
O
N
C
S
S
CLAY UNKNOWN SIZE SS CLAY UNKNOWN SIZE SS CLAY UNKNOWN SIZE SS CLAY UNKNOWN SIZE SS
6'
'
P
V
C
S
S
6'
'
P
V
C
S
S
4'
'
C
O
N
C
S
S
4'
'
C
O
N
C
S
S
00
A
33
00
A
34
00
A
35
00
A
36
PH16
PH17
PH18 PH19
PH20
PH21
PH22
PH22A
PH G11 PH G12
PH P9
P0
6
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
P0
6
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
P0
6
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
P0
6
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
GPH61
GPH62
GPH63
GPH64
PPH67
PPH68
GPH71
PREPARATION KEYNOTES
PREPARATION GENERAL NOTES
PH#
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
P01 P02 P03 P04 P05 P06 P07 P08
P1
1
P1
0
P09
8'
'
P
V
C
S
S
8'' PVC SS
8'' PVC SS
8'' CLAY SS
8'' CLAY SS
8'' CLAY SS
8'' CLAY SS
8'' CLAY SS
8
'
'
P
V
C
S
S
1170 MONROE AVE NE
TPN: 0923059170
3233 NE 12TH ST
TPN: 7801300000
METER SERVICES ON
LYNNWOODTPN: 7227900018
3316 NE 12TH ST
TPN: 7736100015
3232 NE 12TH ST
TPN: 0423059316
3224 NE 12TH ST
TPN: 0423059169
3/4" METER ACCNT
#7720-000
3218 NE 12TH ST
TPN: 0423059182
1-1/2" METER
ACCNT #17721-00
LY
N
N
W
O
O
D
A
V
E
N
E
M
O
N
R
O
E
A
V
E
N
E
NE 12TH ST
P
P
P
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
OHP OHP
OH
P
OH
P
OH
P
OH
P
O
H
P
OHP OHP OHP OHP OHP
OHP
O
H
P
O
H
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
P
P
10'' CI W (435)10'' CI W (435)10'' CI W (435)10'' CI W (435)
10'' CI W (435)
TEL
TELTELTEL
TEL TEL TEL TEL TEL TEL
TEL
TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL
TE
L
TE
L
T
E
L
TE
L
TE
L
TE
L
4'' STL W (ABN)
10
'
'
D
I
W
(
5
6
5
)
10
'
'
D
I
W
(
5
6
5
)
W
W
6'' DI W (565)6'' DI W (565)
8'
'
C
I
W
(
5
6
5
)
4'' IP G
G
4'' IP G
2'' IP G 2'' IP G 2'' IP G 2'' IP G 2'' IP G
2'
'
I
P
G
G
G
4'
'
C
I
W
(
5
6
5
)
10'' CI W (565)10'' CI W (565)10'' CI W (565)10'' CI W (565)10'' CI W (565)10'' CI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
1
2
'
'
C
M
P
S
T
12'' ST 12'' ST
6''
C
O
N
C
S
T
12'' CONC ST (ABAN)
12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
8'
'
C
M
P
S
T
8
'
'
C
M
P
S
T
FO
x
x
x
x
x
xxxxxxxxxxxx
x
x
x
x
xxxxxxxx
x x x
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
CO
R
T
E
L
M
COR TELM COR TELM
ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W
4''
C
O
N
C
S
S
4''
C
O
N
C
S
S
4''
C
O
N
C
S
S
4''
C
O
N
C
S
S
CLAY UNKNOWN SIZE SS CLAY UNKNOWN SIZE SS CLAY UNKNOWN SIZE SS CLAY UNKNOWN SIZE SS
6'
'
P
V
C
S
S
6'
'
P
V
C
S
S
4'
'
C
O
N
C
S
S
4'
'
C
O
N
C
S
S
00
A
33
00
A
34
00
A
35
00
A
36
12'' DI W (565)12'' DI W (565)12'' DI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH16
PH17
PH18 PH19
PH20
PH21
PH22
PH22A
PH G11 PH G12
PH P9
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
XXXXXXXX
P0
6
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
P0
6
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
P0
6
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
P0
6
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
X
X
X
X
X\\\
\\\\\\XXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X \\
GPH61
GPH62
GPH63
GPH64
PPH67
PPH68
GPH71
PH#HMA UTILITY DIRECTION DEPTH TO TOP
”
”
”
”
POTHOLE NOTES
PSE POTHOLE INVESTIGATION NOTES
PH#HMA UTILITY DIRECTION DEPTH TO TOP
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
2
.
D
W
G
SHOWN
P06 12 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EXISTING PLAN VIEW
EX
I
S
T
I
N
G
,
D
E
M
O
L
I
T
I
O
N
,
A
N
D
P
R
E
P
A
R
A
T
I
O
N
PL
A
N
0
6
NE
1
2
T
H
S
T
-
K
I
R
K
L
A
N
D
A
V
E
T
O
M
O
N
R
O
E
A
V
E
DEMOLITION AND PREPARATION PLAN VIEW
x x x x x x x
x
x
x
x
x x x x x x x x x
x
x
x x
x
x
x x x x x x x x x
x
x
x
P
P PP
P
P
PT
E
L
T
E
L
TEL TEL TEL
TEL TEL
TEL
TEL TELTEL
TEL TEL TEL TELTELTELTELTEL
TELTELTEL
TEL TEL TEL TEL TEL
TEL
P
P
P
OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
OHP
OHP
OHP OHP OHP
x
x
x
x
x
xxxxxx
x
x
x
x
TEL TEL
P
16'' CI W 16'' CI W 16'' CI W
G G G G G G G G
P
P
TEL TEL
GGGGGG
W
10'' CI W 10'' CI W 10'' CI W
16
'
'
C
I
W
16'' CI W 16'' CI WTELTELTELTELTEL
TE
L
TE
L
TE
L
16
'
'
C
I
W
x x x x x x x x x x x x
x x x
x
x x x x x
TEL
TE
L
12'' CI W 12'' CI W
8'' CLAY SS
8'' CLAY SS
8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS
W
8'' AC W (565)
3323 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#59301-000
3317 NE 12TH ST
TPN: 0923059162
3/4" METER ACCNT
#24137-000
1204 MONROE AVE NE
TPN: 7736100055
3/4" METER ACCNT
#7801-000
3316 NE 12TH ST
TPN: 7736100015
MO
N
R
O
E
A
V
E
N
E
NE 12TH ST
OHP OHP OHP
O
H
P
O
H
P
OH
P
OH
P
OH
P
12'' CI W (435)
12'' CI W (435)12'' CI W (435)
16'' DI W (435)16'' DI W (435)16'' DI W (435)
O
H
P
O
H
P
O
H
P
O
H
P
O
H
P
OHP
OHP
OHP OHP OHP OHP
OH
P
10'' CI W (435)
TEL TEL
TEL TEL TEL
TEL TEL TELTEL
TEL
TE
L
TE
L
TE
L
TE
L
TE
L
TEL TEL TEL TEL TEL TELTELTELTELTELTELTEL
TEL TEL TEL
TEL
G G
G G G 4'' IP G
4'
'
I
P
G
4'
'
I
P
G
8'
'
D
I
W
(
5
6
5
)
W
G
G
4'' IP G
10'' CI W (565)10'' CI W (565)10'' CI W (565)
FO FOFO
x x x x x x x
x
x x
x
x
x
x x x x
x
TELTEL
PP
TELTELP
T
E
L
TELTELTEL PPP
P
T
E
L
PP
TEL
PP
3401 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#44306-000
3410 NE 12TH ST
TPN: 0423059186
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
CO
R
T
E
L
M
ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W
ABN
D
W
ABN
D
W
ABN
D
W
ABN
D
W
ABN
D
W
ABN
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
ABND WABND WABND WABND WABND WABND W
ABND WABND WABND WABND W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
3327 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#7742-000
CLAY UNKNOWN SIZE SS
6'
'
C
O
N
C
S
S
4'
'
S
S
(
A
B
A
N
)
00
A
37
00
A
38
00
A
39
00
A
40
00B10
00B11
PH G13
PH G14
PH G15 PH G16
P0
7
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
P0
7
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
P0
7
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
P0
7
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
P10 MATCHLINE STA 10+95BP10 MATCHLINE STA 10+95B
P07 MATCHLINE STA 10+95BP07 MATCHLINE STA 10+95B
GPH74
GPH75
GPH82
PREPARATION KEYNOTES
PREPARATION GENERAL NOTES
PH#
PH#HMA UTILITY DIRECTION DEPTH TO TOP
POTHOLE NOTES
PSE POTHOLE INVESTIGATION NOTES
PH#HMA UTILITY DIRECTION DEPTH TO TOP
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
P01 P02 P03 P04 P05 P06 P07 P08
P1
1
P1
0
P09
x x x x x x x
x
x
x
x
x x x x x x x x x
x
x
x x
x
x
x x x x x x x x x
x
x
x
P
P PP
P
P
PT
E
L
T
E
L
TEL TEL TEL
TEL TEL
TEL
TEL TELTEL
TEL TEL TEL TELTELTELTELTEL
TELTELTEL
TEL TEL TEL TEL TEL
TEL
P
P
P
OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
OHP
OHP
OHP OHP OHP
x
x
x
x
x
xxxxxx
x
x
x
x
TEL TEL
P
16'' CI W 16'' CI W 16'' CI W
G G G G G G G G
P
P
TEL TEL
GGGGGG
W
10'' CI W 10'' CI W 10'' CI W
16
'
'
C
I
W
16'' CI W 16'' CI WTELTELTELTELTEL
TE
L
TE
L
TE
L
16
'
'
C
I
W
x x x x x x x x x x x x
x x x
x
x x x x x
TEL
TE
L
12'' CI W 12'' CI W
8'' CLAY SS
8'' CLAY SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS
W
8'' AC W (565)
3323 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#59301-000
3317 NE 12TH ST
TPN: 0923059162
3/4" METER ACCNT
#24137-000
1204 MONROE AVE NE
TPN: 7736100055
3/4" METER ACCNT
#7801-000
3316 NE 12TH ST
TPN: 7736100015
MO
N
R
O
E
A
V
E
N
E
NE 12TH ST
OHP OHP OHP
O
H
P
O
H
P
OH
P
OH
P
OH
P
12'' CI W (435)
12'' CI W (435)12'' CI W (435)
16'' DI W (435)16'' DI W (435)16'' DI W (435)
O
H
P
O
H
P
O
H
P
O
H
P
O
H
P
OHP
OHP
OHP OHP OHP OHP
OH
P
10'' CI W (435)
TEL TEL
TEL TEL TEL
TEL TEL TELTEL
TEL
TE
L
TE
L
TE
L
TE
L
TE
L
TEL TEL TEL TEL TEL TELTELTELTELTELTELTEL
TEL TEL TEL
TEL
G G
G G G 4'' IP G
4'
'
I
P
G
4'
'
I
P
G
8'
'
D
I
W
(
5
6
5
)
W
G
G
4'' IP G
10'' CI W (565)10'' CI W (565)10'' CI W (565)
FO FOFO
x x x x x x x
x
x x
x
x
x
x x x x
x
TELTEL
PP
TELTELP
T
E
L
TELTELTEL PPP
P
T
E
L
PP
TEL
PP
3401 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#44306-000
3410 NE 12TH ST
TPN: 0423059186
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
CO
R
T
E
L
M
ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W
ABN
D
W
ABN
D
W
ABN
D
W
ABN
D
W
ABN
D
W
ABN
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
ABND WABND WABND WABND WABND WABND W
ABND WABND WABND WABND W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
3327 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#7742-000
CLAY UNKNOWN SIZE SS
6'
'
C
O
N
C
S
S
4'
'
S
S
(
A
B
A
N
)
00
A
37
00
A
38
00
A
39
00
A
40
00B10
00B11
12'' DI W (565)
12'' DI W (565)
12'' DI W (565)
16'' DI W
G G G G G G G G G
FO
FO FO FO FO FO FO FO
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\
\
\
\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH G13
PH G14
PH G15 PH G16
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
X
P0
7
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
P0
7
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
P0
7
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
P0
7
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
P10 MATCHLINE STA 10+95BP10 MATCHLINE STA 10+95B
P07 MATCHLINE STA 10+95BP07 MATCHLINE STA 10+95B
X X
X
X
X
X
X
X
X
GPH74
GPH75
GPH82
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
2
.
D
W
G
SHOWN
P07 13 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EXISTING PLAN VIEW
EX
I
S
T
I
N
G
,
D
E
M
O
L
I
T
I
O
N
,
A
N
D
P
R
E
P
A
R
A
T
I
O
N
PL
A
N
0
7
NE
1
2
T
H
S
T
-
M
O
N
R
O
E
A
V
E
T
O
O
L
Y
M
P
I
A
A
V
E
DEMOLITION AND PREPARATION PLAN VIEW
10''
C
O
N
C
S
T
x
x x x x x x x x x x x x x x x x x x x x x x
x
x
x
x
x
xxxxxxx
xx x
P P P
P
TEL
TEL
TE
L
TE
L
TEL TEL TEL TEL TEL
TEL
TE
L
TEL TEL TELTELTELTEL
TEL
TEL TEL TEL
TE
L
TEL TEL TEL TEL TEL
OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
x
x
TEL
x
x
x
x
x
x
x
x
x
x
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
8'
'
C
O
N
C
S
S
8'' CONC SS 8'' CONC SS 8'' CONC SS
SS
(
A
B
N
D
)
SS
(
A
B
N
D
)
SD
TEL
8'
'
W
(
5
6
5
)
G G G G G G G G G G G G
OHP OHP OHP OHP OHP OHP OHP OHP
TEL TEL TEL TEL TEL TEL TEL TEL
TEL
TEL
TEL TEL TEL
TE
L
TE
L
G
G G G G
G G G
G G G
W W
16'' CI W
10
'
'
C
O
N
C
S
S
6'
'
P
V
C
S
S
6'
'
P
V
C
S
S
x
x
x
x
x
x
x
10'' CONC SD
10'
'
C
O
N
C
S
D
10'
'
C
O
N
C
S
D
10'
'
C
O
N
C
S
D
x x x x x x x x x x x x x x x x x x x x x x x x x x
12
'
'
C
I
W
12'' CI W
OHP
8'' CONC SS
8'' AC W (565)8'' AC W (565)8'' AC W (565)
8'' AC W (565)
NA
TP
N
:
0
4
2
3
0
5
9
2
5
1
OL
Y
M
P
I
A
A
V
E
N
E
NE 12TH ST
TELTEL
TELPP
PTEL
3417 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#54364-000
3501 NE 12TH ST
TPN: 8062900035
3/4" METER ACCNT
#7747-000
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES ON PIERCE
12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
TEL
x x
G G
TEL TEL TEL TEL
TEL
ABND W
00
A
41
00
A
42
00
A
43
PH24
PH G17 PH G18
P0
8
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
P0
8
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
P0
8
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
P0
9
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
P0
8
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
P0
9
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
GPH98
GPH99
PREPARATION KEYNOTES
PREPARATION GENERAL NOTES
PH#
PH#HMA UTILITY DIRECTION DEPTH TO TOP
”
POTHOLE NOTES
PSE POTHOLE INVESTIGATION NOTES
PH#HMA UTILITY DIRECTION DEPTH TO TOP
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
P01 P02 P03 P04 P05 P06 P07 P08
P1
1
P1
0
P09
10''
C
O
N
C
S
T
x
x x x x x x x x x x x x x x x x x x x x x x
x
x
x
x
x
xxxxxxx
xx x
P P P
P
TEL
TEL
TE
L
TE
L
TEL TEL TEL TEL TEL
TEL
TE
L
TEL TEL TELTELTELTEL
TEL
TEL TEL TEL
TE
L
TEL TEL TEL TEL TEL
OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
x
x
TEL
x
x
x
x
x
x
x
x
x
x
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
8'
'
C
O
N
C
S
S
8'' CONC SS 8'' CONC SS 8'' CONC SS
SS
(
A
B
N
D
)
SS
(
A
B
N
D
)
SD
TEL
8'
'
W
(
5
6
5
)
G G G G G G G G G G G G
OHP OHP OHP OHP OHP OHP OHP OHP
TEL TEL TEL TEL TEL TEL TEL TEL
TEL
TEL
TEL TEL TEL
TE
L
TE
L
G
G G G G
G G G
G G G
W W
16'' CI W
10
'
'
C
O
N
C
S
S
6'
'
P
V
C
S
S
6'
'
P
V
C
S
S
x
x
x
x
x
x
x
10'' CONC SD
10'
'
C
O
N
C
S
D
10'
'
C
O
N
C
S
D
10'
'
C
O
N
C
S
D
x x x x x x x x x x x x x x x x x x x x x x x x x x
12
'
'
C
I
W
12'' CI W
OHP
8'' CONC SS
8'' AC W (565)8'' AC W (565)8'' AC W (565)
8'' AC W (565)
NA
TP
N
:
0
4
2
3
0
5
9
2
5
1
OL
Y
M
P
I
A
A
V
E
N
E
NE 12TH ST
TELTEL
TELPP
PTEL
3417 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#54364-000
3501 NE 12TH ST
TPN: 8062900035
3/4" METER ACCNT
#7747-000
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES ON PIERCE
12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
TEL
x x
G G
TEL TEL TEL TEL
TEL
ABND W
00
A
41
00
A
42
00
A
43
12'' DI W (565)
12'' DI W (565)
16'' DI W
G G G G G G G G
12'' DI W (565)
X
X
X
X
X
X
X
X
X
X
X
X
\
\
\
\
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\PH24 \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
PH G17 PH G18
\
\
\
\
\
\
\
\
\
P0
8
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
P0
8
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
P0
8
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
P0
9
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
P0
8
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
P0
9
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
X
X
\
\
\
\
\
\
\
GPH98
GPH99
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
2
.
D
W
G
SHOWN
P08 14 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EXISTING PLAN VIEW
EX
I
S
T
I
N
G
,
D
E
M
O
L
I
T
I
O
N
,
A
N
D
P
R
E
P
A
R
A
T
I
O
N
PL
A
N
0
8
NE
1
2
T
H
S
T
-
M
O
N
R
O
E
A
V
E
T
O
O
L
Y
M
P
I
A
A
V
E
DEMOLITION AND PREPARATION PLAN VIEW
xxxxxxx
TEL TEL
G
G
OH
P
OH
P
x
x
x
G
G
8'' CONC SS 8'' CONC SS 8'' CONC SS8'' CONC SS 8'' CONC SS
8'
'
C
O
N
C
S
S
G
OHP OHP
G GGG
8'' AC W (565)
PI
E
R
C
E
P
L
N
E
3515 NE 12TH ST
TPN: 8062900040
3/4" METER ACCNT
#46676-000
8'
'
C
O
N
C
S
S
8'' CONC SS 8'' CONC SS 8'' CONC SS
8'
'
C
O
N
C
S
S
SDSDSDSD
12'' CONC ST 12'' CONC ST 12'' CONC ST
OHP OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OHP OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
x
x
OH
P
OH
P
OH
P
OH
P
x
8'' AC W (565)8'' AC W (565)8'' AC W (565)8'' AC W (565)
OH
P
OH
P
OH
P
OH
P
OH
P
O
H
P
O
H
P
OHP OHP
W
1204 PIERCE PL NE
TPN:0911500160
METER SERVICES ON PIERCE
1203 QUEEN AVE NE
TPN:0911500105
METER SERVICES ON QUEEN
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES
ON QUEEN
1159 PIERCE AVE NE
TPN: 8062900005
3607 NE 12TH ST
TPN: 0923059205
3/4" METER ACCNT
#45388-000
3613 NE 12TH ST
TPN: 0923059252
8
D
I
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
8
D
I
W
(
5
6
5
)
8
D
I
W
(
5
6
5
)
G
G G G G G G G G G G G
TEL TELTEL
TEL
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL TEL
TEL
xxxxxxx TOP
TOP
x x x xxxxx
xxxxxxxx
x
xxxxxxxxxxxxxxxxxx
TOE
TOE TOE TOE
x x x x x
G G
TEL
TEL
TE
L
QU
E
E
N
A
V
E
N
E
NE 12TH ST
PI
E
R
C
E
A
V
E
N
E
10
C
O
N
C
S
T
12'' CONC ST 12'' CONC ST 12'' CONC ST
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES
ON PIERCE
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
12'' DI W (565)12'' DI W (565)12'' DI W (565)00
A
44
00
A
45
00
A
46
00
A
47
PH G19
P0
9
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
P0
9
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
GPH109
GPH111
PREPARATION KEYNOTES
PREPARATION GENERAL NOTES
PH#
PH#HMA UTILITY DIRECTION DEPTH TO TOP
POTHOLE NOTES
PSE POTHOLE INVESTIGATION NOTES
PH#HMA UTILITY DIRECTION DEPTH TO TOP
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
P01 P02 P03 P04 P05 P06 P07 P08
P1
1
P1
0
P09
xxxxxxx
TEL TEL
G
G
OH
P
OH
P
x
x
x
G
G
8'' CONC SS 8'' CONC SS 8'' CONC SS8'' CONC SS 8'' CONC SS
8'
'
C
O
N
C
S
S
G
OHP OHP
G GGG
8'' AC W (565)
PI
E
R
C
E
P
L
N
E
3515 NE 12TH ST
TPN: 8062900040
3/4" METER ACCNT
#46676-000
8'
'
C
O
N
C
S
S
8'' CONC SS 8'' CONC SS 8'' CONC SS
8
'
'
C
O
N
C
S
S
SDSDSDSD
12'' CONC ST 12'' CONC ST 12'' CONC ST
OHP OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OHP OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
x
x
OH
P
OH
P
OH
P
OH
P
x
8'' AC W (565)8'' AC W (565)8'' AC W (565)8'' AC W (565)
OH
P
OH
P
OH
P
OH
P
OH
P
O
H
P
O
H
P
OHP OHP
W
1204 PIERCE PL NE
TPN:0911500160
METER SERVICES ON PIERCE
1203 QUEEN AVE NE
TPN:0911500105
METER SERVICES ON QUEEN
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES
ON QUEEN
1159 PIERCE AVE NE
TPN: 8062900005
3607 NE 12TH ST
TPN: 0923059205
3/4" METER ACCNT
#45388-000
3613 NE 12TH ST
TPN: 0923059252
8
D
I
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
8
D
I
W
(
5
6
5
)
8
D
I
W
(
5
6
5
)
G
G G G G G G G G G G G
TEL TELTEL
TEL
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL TEL
TEL
xxxxxxx TOP
TOP
x x x xxxxx
xxxxxxxx
x
xxxxxxxxxxxxxxxxxx
TOE
TOE TOE TOE
x x x x x
G G
TEL
TEL
TE
L
QU
E
E
N
A
V
E
N
E
NE 12TH ST
PI
E
R
C
E
A
V
E
N
E
10
C
O
N
C
S
T
12'' CONC ST 12'' CONC ST 12'' CONC ST
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES
ON PIERCE
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
12'' DI W (565)12'' DI W (565)12'' DI W (565)00
A
44
00
A
45
00
A
46
00
A
4712'' DI W (565)
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
PH G19
P0
9
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
P0
9
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
\
\
X
GPH109
GPH111
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
2
.
D
W
G
SHOWN
P09 15 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EXISTING PLAN VIEW
EX
I
S
T
I
N
G
,
D
E
M
O
L
I
T
I
O
N
,
A
N
D
P
R
E
P
A
R
A
T
I
O
N
PL
A
N
0
9
NE
1
2
T
H
S
T
-
O
L
Y
M
P
I
A
A
V
E
T
O
Q
U
E
E
N
A
V
E
DEMOLITION AND PREPARATION PLAN VIEW
x
x
x
x
x x x x
OH
P
OH
P
OH
P
8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS
1316 MONROE AVE NE
TPN: 7736100041
13
1
3
M
O
N
R
O
E
A
V
E
N
E
TP
N
:
7
7
3
6
1
0
0
0
0
3
12
0
4
M
O
N
R
O
E
A
V
E
N
E
TP
N
:
7
7
3
6
1
0
0
0
5
5
3/
4
"
M
E
T
E
R
A
C
C
N
T
#7
8
0
1
-
0
0
0
33
1
6
N
E
1
2
T
H
S
T
TP
N
:
7
7
3
6
1
0
0
0
1
5
MONROE AVE NE
OH
P
OH
P
OH
P
OHP
OHP OHP OHP OHP OHP OHP
16
'
'
D
I
W
(
4
3
5
)
16
'
'
D
I
W
(
4
3
5
)
16
'
'
D
I
W
(
4
3
5
)
OHP OHP OHP OHP OHP
OHP
OHP
OHP
P
P
OHP OHP OHP OHP
O
H
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
O
H
P
O
H
P
O
H
P
OH
P
OH
P
OH
P
O
H
P
O
H
P
O
H
P
OHP
OHP
O
H
P
O
H
P
OH
P
OH
P
OH
P
OH
P
OHP
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TELTELTELTELTELTELTEL TEL
TE
L
TE
L
TE
L
TE
L
TE
L
G
W
4'' IP G 4'' IP G 4'' IP G 4'' IP G 4'' IP G
8'' DI W (565)
8'' DI W (565)8'' DI W (565)8'' DI W (565)
4'' IP G 4'' IP G
8'' DI W (565)
W
W
W
W
W
W
W
W
W
G
G G
4'' IP G
G
G
G
G
G
G
4'' CI W (565)4'' CI W (565)4'' CI W (565)4'' CI W (565)4'' CI W (565)
10
'
'
C
I
W
(
5
6
5
)
10
'
'
C
I
W
(
5
6
5
)
10
'
'
C
I
W
(
5
6
5
)
G
G
G
G G G G
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
S
S
S
S
SS
xxxxxxxxx
x
x
x
x
xxxx
x
x
x
x
1308 MONROE AVE NE
TPN: 7736100040
1300 MONROE AVE NE
TPN: 7736100045
1216 MONROE AVE NE
TPN: 7736100046
1210 MONROE AVE NE
TPN: 7736100050
1209 MONROE AVE NE
TPN: 7736100016
1215 MONROE AVE NE
TPN: 7736100010
1305 MONROE AVE NE
TPN: 7736100008
1309 MONROE AVE NE
TPN: 7736100005
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
6'' CONC SS
00A37
00A38
00
B
10
00
B
11
00
B
12
00
B
13
00
B
14
PH
G
1
3
PH
G
1
4
P06 MATCHLINE STA 36+40A
P07 MATCHLINE STA 36+40A
P1
0
M
A
T
C
H
L
I
N
E
S
T
A
1
0
+
9
5
B
P1
0
M
A
T
C
H
L
I
N
E
S
T
A
1
0
+
9
5
B
P0
7
M
A
T
C
H
L
I
N
E
S
T
A
1
0
+
9
5
B
P0
7
M
A
T
C
H
L
I
N
E
S
T
A
1
0
+
9
5
B
P1
0
M
A
T
C
H
L
I
N
E
S
T
A
14
+
1
6
B
P1
0
M
A
T
C
H
L
I
N
E
S
T
A
14
+
1
6
B
GP
H
7
4
GP
H
7
5
PREPARATION KEYNOTES
PREPARATION GENERAL NOTES
PH#
PH#HMA UTILITY DIRECTION DEPTH TO TOP
POTHOLE NOTES
PSE POTHOLE INVESTIGATION NOTES
PH#HMA UTILITY DIRECTION DEPTH TO TOP
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
P01 P02 P03 P04 P05 P06 P07 P08
P1
1
P1
0
P09
x
x
x
x
x x x x
OH
P
OH
P
OH
P
8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS
1316 MONROE AVE NE
TPN: 7736100041
13
1
3
M
O
N
R
O
E
A
V
E
N
E
TP
N
:
7
7
3
6
1
0
0
0
0
3
12
0
4
M
O
N
R
O
E
A
V
E
N
E
TP
N
:
7
7
3
6
1
0
0
0
5
5
3/
4
"
M
E
T
E
R
A
C
C
N
T
#7
8
0
1
-
0
0
0
33
1
6
N
E
1
2
T
H
S
T
TP
N
:
7
7
3
6
1
0
0
0
1
5
MONROE AVE NE
OH
P
OH
P
OH
P
OHP
OHP OHP OHP OHP OHP OHP
16
'
'
D
I
W
(
4
3
5
)
16
'
'
D
I
W
(
4
3
5
)
16
'
'
D
I
W
(
4
3
5
)
OHP OHP OHP OHP OHP
OHP
OHP
OHP
P
P
OHP OHP OHP OHP
O
H
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
O
H
P
O
H
P
O
H
P
OH
P
OH
P
OH
P
O
H
P
O
H
P
O
H
P
OHP
OHP
O
H
P
O
H
P
OH
P
OH
P
OH
P
OH
P
OHP
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TELTELTELTELTELTELTEL TEL
TE
L
TE
L
TE
L
TE
L
TE
L
G
W
4'' IP G 4'' IP G 4'' IP G 4'' IP G 4'' IP G
8'' DI W (565)
8'' DI W (565)8'' DI W (565)8'' DI W (565)
4'' IP G 4'' IP G
8'' DI W (565)
W
W
W
W
W
W
W
W
W
G
G G
4'' IP G
G
G
G
G
G
G
4'' CI W (565)4'' CI W (565)4'' CI W (565)4'' CI W (565)4'' CI W (565)
10
'
'
C
I
W
(
5
6
5
)
10
'
'
C
I
W
(
5
6
5
)
10
'
'
C
I
W
(
5
6
5
)
G
G
G
G G G G
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
S
S
S
S
SS
xxxxxxxxx
x
x
x
x
xxxx
x
x
x
x
1308 MONROE AVE NE
TPN: 7736100040
1300 MONROE AVE NE
TPN: 7736100045
1216 MONROE AVE NE
TPN: 7736100046
1210 MONROE AVE NE
TPN: 7736100050
1209 MONROE AVE NE
TPN: 7736100016
1215 MONROE AVE NE
TPN: 7736100010
1305 MONROE AVE NE
TPN: 7736100008
1309 MONROE AVE NE
TPN: 7736100005
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
CO
R
T
E
L
M
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
6'' CONC SS
00A37
00A38
00
B
10
00
B
11
00
B
12
00
B
13
00
B
14
12
'
'
D
I
W
(
5
6
5
)
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\\\\\\\\\
\\\\\
\\\\
PH
G
1
3
PH
G
1
4
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
P06 MATCHLINE STA 36+40A
P07 MATCHLINE STA 36+40A
P1
0
M
A
T
C
H
L
I
N
E
S
T
A
1
0
+
9
5
B
P1
0
M
A
T
C
H
L
I
N
E
S
T
A
1
0
+
9
5
B
P0
7
M
A
T
C
H
L
I
N
E
S
T
A
1
0
+
9
5
B
P0
7
M
A
T
C
H
L
I
N
E
S
T
A
1
0
+
9
5
B
P1
0
M
A
T
C
H
L
I
N
E
S
T
A
14
+
1
6
B
P1
0
M
A
T
C
H
L
I
N
E
S
T
A
14
+
1
6
B
X X
GP
H
7
4
GP
H
7
5
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
2
.
D
W
G
SHOWN
P10 16 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EXISTING PLAN VIEW
EX
I
S
T
I
N
G
,
D
E
M
O
L
I
T
I
O
N
,
A
N
D
P
R
E
P
A
R
A
T
I
O
N
PL
A
N
1
0
MO
N
R
O
E
A
V
E
-
N
E
1
2
T
H
S
T
T
O
S
U
N
S
E
T
A
V
E
DEMOLITION AND PREPARATION PLAN VIEW
10
'
'
D
I
W
(
5
6
5
)
10
'
'
D
I
W
(
5
6
5
)
S
D
S
D
8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
1409 & 1417 MONROE AVE NE
TPN: 0423059104
3/4" METER ACCNT #7730-000
1408 MONROE AVE NE
TPN: 7736100030
3/4" METER ACCNT
#7809-000
1400 MONROE AVE NE
TPN: 7736100035
3/4" METER ACCNT
#7808-000
1324 MONROE AVE NE
TPN: 7736100036
3/4" METER ACCNT
#7807-000
1333 MONROE AVE NE
TPN: 0423059111
3/4" METER ACCNT
#57275-000
1401 MONROE AVE NE
TPN: 0423059126
3/4" METER ACCNT
#28758-000
1416 MONROE AVE NE
TPN: 7736100020
NA
TP
N
:
0
4
2
3
0
5
T
R
C
T
NA
TPN: 7736100025
N
E
S
U
N
S
E
T
B
L
V
D
MONROE AVE. NE
P
P
P P P PPP
P
P
P
P
OHP OHP OHP OHP OHP
OH
P
O
H
P
O
H
P
O
H
P
O
H
P
OH
P
O
H
P
O
H
P
O
H
P
OH
P
OH
P
OH
P
TEL TEL
TEL
TEL TEL TEL TEL TEL
TE
L
T
E
L
TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL
TEL
TEL TEL
TEL TELTELTEL TEL TEL TEL
TEL TEL TEL
TEL
TE
L
TE
L
TE
L
TE
L
TE
L
10'' DI W (565)10'' DI W (565)10'' DI W (565)
4'' IP G
4'' IP G 4'' IP G 4'' IP G 4'' IP G 4'' IP G
4'' IP G
4'
'
D
I
W
(
5
6
5
)
W
W W
W
W
W
W
W
W
W
W
W
G
G
G
4'' CI W (565)4'' CI W (565)
G
G
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
x
x
xxxxxxxxxx
x
xx
x
x
xx
x
x
x
x
W
TEL TEL TEL TEL TEL
13
1
5
M
O
N
R
O
E
A
V
E
N
E
TP
N
:
7
7
3
6
1
0
0
0
0
3
00
B
15
00
B
16
00
B
17
00
B
18
00
B
19
PH G21
PH P10
PH P11
P1
1
M
A
T
C
H
L
I
N
E
S
T
A
14
+
1
6
B
P1
1
M
A
T
C
H
L
I
N
E
S
T
A
14
+
1
6
B
GPH114
PPH115
GPH116
PPH117 GPH118
PREPARATION KEYNOTES
PREPARATION GENERAL NOTES
PH#
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
P01 P02 P03 P04 P05 P06 P07 P08
P1
1
P1
0
P09
PH#HMA UTILITY DIRECTION DEPTH TO TOP
POTHOLE NOTES
PSE POTHOLE INVESTIGATION NOTES
PH#HMA UTILITY DIRECTION DEPTH TO TOP
10
'
'
D
I
W
(
5
6
5
)
10
'
'
D
I
W
(
5
6
5
)
S
D
S
D
8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
1409 & 1417 MONROE AVE NE
TPN: 0423059104
3/4" METER ACCNT #7730-000
1408 MONROE AVE NE
TPN: 7736100030
3/4" METER ACCNT
#7809-000
1400 MONROE AVE NE
TPN: 7736100035
3/4" METER ACCNT
#7808-000
1324 MONROE AVE NE
TPN: 7736100036
3/4" METER ACCNT
#7807-000
1333 MONROE AVE NE
TPN: 0423059111
3/4" METER ACCNT
#57275-000
1401 MONROE AVE NE
TPN: 0423059126
3/4" METER ACCNT
#28758-000
1416 MONROE AVE NE
TPN: 7736100020
NA
TP
N
:
0
4
2
3
0
5
T
R
C
T
NA
TPN: 7736100025
N
E
S
U
N
S
E
T
B
L
V
D
MONROE AVE. NE
P
P
P P P PPP
P
P
P
P
OHP OHP OHP OHP OHP
OH
P
O
H
P
O
H
P
O
H
P
O
H
P
OH
P
O
H
P
O
H
P
O
H
P
OH
P
OH
P
OH
P
TEL TEL
TEL
TEL TEL TEL TEL TEL
TE
L
T
E
L
TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL
TEL
TEL TEL
TEL TELTELTEL TEL TEL TEL
TEL TEL TEL
TEL
TE
L
TE
L
TE
L
TE
L
TE
L
10'' DI W (565)10'' DI W (565)10'' DI W (565)
4'' IP G
4'' IP G 4'' IP G 4'' IP G 4'' IP G 4'' IP G
4'' IP G
4'
'
D
I
W
(
5
6
5
)
W
W W
W
W
W
W
W
W
W
W
W
G
G
G
4'' CI W (565)4'' CI W (565)
G
G
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
x
x
xxxxxxxxxx
x
xx
x
x
xx
x
x
x
x
W
TEL TEL TEL TEL TEL
13
1
5
M
O
N
R
O
E
A
V
E
N
E
TP
N
:
7
7
3
6
1
0
0
0
0
3
00
B
15
00
B
16
00
B
17
00
B
18
00
B
19
8'' DI W (565)8'' DI W (565)
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PR
O
P
O
S
E
D
8
"
W
A
T
E
R
M
A
I
N
56
5
Z
O
N
E
PH G21
PH P10
PH P11
P1
1
M
A
T
C
H
L
I
N
E
S
T
A
14
+
1
6
B
P1
1
M
A
T
C
H
L
I
N
E
S
T
A
14
+
1
6
B
X X
GPH114
PPH115
GPH116
PPH117 GPH118
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
2
.
D
W
G
SHOWN
P11 17 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EXISTING PLAN VIEW
EX
I
S
T
I
N
G
,
D
E
M
O
L
I
T
I
O
N
,
A
N
D
P
R
E
P
A
R
A
T
I
O
N
PL
A
N
1
1
MO
N
R
O
E
A
V
E
-
N
E
1
2
T
H
S
T
T
O
S
U
N
S
E
T
A
V
E
DEMOLITION AND PREPARATION PLAN VIEW
8'' CP SS
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
2601 & 2603 NE 12TH ST
TPN: 7227801335
1" LATERAL 3/4" METER
ACCNT #003066
NA
TPN: 0923059102
NO METER
2527 NE 12TH ST
TPN: 0923059062
1" LATERAL 3/4"
METER ACCNT
#140025
1140 EDMONDS AVE NE
TPN: 0923059061
METER ON EDMONDS
1190 EDMONDS PL NE
TPN: 2270000020
1194 EDMONDS PL NE
TPN: 2270000010
2430 NE 12TH ST
TPN: 2309200010
JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
ED
M
O
N
D
S
A
V
E
N
E
NE 12TH STREET
P P P P
P
P P P P P P P PPP
8'' AC W (435)
16
'
'
D
I
W
(
4
3
5
)
8'
'
C
I
W
(
4
3
5
)
8'
'
C
I
W
(
4
3
5
)
8'' AC W (435)12'' AC W (435)12'' AC W (435)12'' AC W (435)12'' AC W (435)12'' AC W (435)
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
W
16
'
'
D
I
W
(
4
3
5
)
16
'
'
D
I
W
(
4
3
5
)
W
P
P
P
P P P P P
P P P P PPPPPP
P P P P PPPPPP
P
P
P
P
P
P
P
P
P
P
W
T
E
L
T
E
L
TE
L
TEL
TE
L
TE
L
TEL TEL TEL TEL
TEL TEL TEL TEL
TE
L
TE
L
TEL TEL TEL TEL TEL TEL TEL TEL
TE
L
TE
L
TEL TEL TEL TEL
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
CO
R
T
E
L
M
G
G G
6'' IP G 6'' IP G 6'' IP G
G G
G
G
18
'
'
C
O
N
C
S
T
18
'
'
C
O
N
C
S
T
8'' CONC ST
8
'
'
C
O
N
C
S
T
12'' CONC ST
36'' CPEP ST
10''
C
O
N
C
S
T
12'' ST (ABAN)12'' ST (ABAN)
12'' ST (ABAN)12'' ST (ABAN)36'' CMP ST
36'' CMP ST
36'' CMP ST
ST
36'' CMP ST
G
G
x x x x x x x x x x x x x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x x x
x x
x
x
x x x x x x x x x x x
x
x
x
x x x x x x x x x
x
x
x
x
G
G
0
L
F
100 LF 200 LF 300 LF
400
L
F
00
A
10
00
A
11
00
A
12
00
A
13
00
A
14
0
L
F
60
L
F
-10 LF 0 LF
50
L
F
PH1
PH1A
PH2
PH2A
PH G1 PH P1PPH2
PPH3
GPH4
GPH5
GPH6
GPH7
GPH8
PPH9
PPH11
12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)
12
'
'
D
I
W
(
5
6
5
)
3
W0
2
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
W0
2
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
(CONNECTION A)
CONNECTION TO
EXISTING 8" CI WATER
MAIN BY CITY FORCES
(CONNECTION O)
CONNECTION TO
EXISTING 8" AC WATER
MAIN BY CITY FORCES
(CONNECTION X)
CONNECTION TO
EXISTING 16" DI WATER
MAIN BY CITY FORCES
2
1
102
104
105
106
107
101
1
3
6
7
103
U04
U04
U04
4
5
108
2
PROFILE VIEW
310'
320'
330'
340'
350'
310'
320'
330'
340'
350'
-10 LF 0 LF 100 LF 200 LF 300 LF 400 LF 460 LF
PR
O
P
.
S
T
O
R
M
8
"
D
I
P
IE
:
3
4
1
.
5
2
APPROX. 460 LF OF 12" RJ DI PIPE
12" RJ DI WATER MAIN
107
104
101
106
10+06A 10+67A 11+67A 12+67A 13+67A
102 103
PR
O
P
.
S
T
O
R
M
8
"
D
I
P
IE
:
3
3
8
.
3
3
2" BLOWOFF
6" ETHAFOAM PAD
108
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
GENERAL CONSTRUCTION NOTES
7
102
1
101
104
105
106
107
3
6
103
WATER MAIN NOTES (565 ZONE)
WATER MAIN NOTES (435 ZONE)
4
5
108
2
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
W01 W02 W03 W04 W05 W06 W07 W08
W1
1
W09
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
5
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
1
.
D
W
G
SHOWN
W01 18 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
PLAN VIEW
WA
T
E
R
M
A
I
N
P
L
A
N
A
N
D
P
R
O
F
I
L
E
0
1
NE
1
2
T
H
S
T
-
E
D
M
O
N
D
S
A
V
E
T
O
H
A
R
R
I
N
G
T
O
N
A
V
E
REMOVE EXISTING 12" AC WATER MAIN AS
NECESSARY TO INSTALL PROPOSED WATER MAIN
8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS
8'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
4
'
'
C
O
N
C
S
S
SS SS
SS
SS
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
1174 HARRINGTON AVE NE
TPN: 7227801675
METER SERVICE ON HARRINGTON
1177 HARRINGTON AVE NE
TPN: 7227801355
METER SERVICE ON HARRINGTON
2613 & 2615 NE 12TH ST
TPN: 7227801345
1" LATERAL 3/4" METER
ACCNT #003069
2607 & 2609 NE 12TH ST
TPN: 7227801340
1" LATERAL 3/4" METER
ACCNT #003067
JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
NA
TPN: 7227801860
METER SERVICE ON HARRINGTON
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
NE 12TH STREET
P P P
P P P
P
P
P
PPPPPPP
P
P
12'' AC W (435)12'' AC W (435)
16'' DI W (435)16'' DI W (435)16'' DI W (435)
12'' AC W (435)
12'' AC W (435)
W
P P P P P P
P
P P P P
P
P
P P P P P
P
P P P P P P
P P P P P P P
12
A
C
W
(
A
B
A
N
)
16'' DI W (435)16'' DI W (435)
8'' AC W (ABAN)8'' AC W (ABAN)
TEL TEL TEL
TE
L
TE
L
TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL
T
E
L
T
E
L
TE
L
TE
L
T
E
L
T
E
L
TE
L
TE
L
T
E
L
TEL TEL TEL
TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL
6'' IP G
GG
G
GG
6'' IP G 6'' IP G 6'' IP G 6'' IP G
8'
'
C
I
W
(
5
6
5
)
G
G
G
G
12'
'
D
I
W
(
5
6
5
)
8'' CI W (565)8'' CI W (565)
12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
8'
'
C
O
N
C
S
T
18
'
'
C
P
P
S
T
36'' CMP ST 36'' CMP ST
12'' ST 12'' ST
36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST
12
'
'
A
D
S
S
T
1
2
'
'
A
D
S
S
T
8''
C
O
N
C
S
T
x
x x x x x x x x x x x x x x x x x x x
x
x
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
x
x
x
TEL TEL TEL TEL TEL TEL TEL TEL TEL
8'
'
D
I
W
G
500 LF 600 LF 700 LF 800 LF 900 LF00
A
15
00
A
16
00
A
17
00
A
18
00
A
19
PH4
PH5
PH G2PH P2 PH P3
PPH12
PPH13 GPH14 PPH15
PPH17
GPH18
PPH20
12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)
5 6
4
(CONNECTION B)
CONNECTION TO
EXISTING 8" CI WATER
MAIN BY CITY FORCES
(CONNECTION P)
CONNECTION TO
EXISTING 12" DI WATER
MAIN BY CITY FORCES
(CONNECTION C)
CONNECTION TO
EXISTING 8" DI WATER
MAIN BY CITY FORCES
W0
1
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
W0
1
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
W0
3
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
W0
3
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
U04
U04
U04
112
114
115
113
109
110
116
8
(CONNECTION Y)
CONNECTION TO
EXISTING 16" DI WATER
MAIN BY CITY FORCES
111
PROFILE VIEW
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
460 LF 500 LF 600 LF 700 LF 800 LF 900 LF 945 LF
APPROX. 485 LF OF 12" RJ DI PIPE
12" RJ DI WATER MAIN
112
115
14+65A 15+65A 16+65A 17+65A 18+65A
109 111
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
112
113
114
115
109
110
116
8
WATER MAIN NOTES (565 ZONE)
GENERAL CONSTRUCTION NOTES
WATER MAIN NOTES (435 ZONE)
111
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
W01 W02 W03 W04 W05 W06 W07 W08
W1
1
W09
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
1
.
D
W
G
SHOWN
W02 19 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
PLAN VIEW
WA
T
E
R
M
A
I
N
P
L
A
N
A
N
D
P
R
O
F
I
L
E
0
2
NE
1
2
T
H
S
T
-
E
D
M
O
N
D
S
A
V
E
T
O
H
A
R
R
I
N
G
T
O
N
A
V
E
8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SS SS
SS SS
4
'
'
C
O
N
C
S
S
SS
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SS
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SS
1175 HARRINGTON PL NE
TPN: 3122000000
2825 NE 12TH ST
TPN: 7227802045
2801 NE 12TH ST
TPN: 7227801680
1" METER ACCNT #003069
2810 NE 12TH ST
TPN: 7227801685
EXISTING 3/4" METER ACCNT
2902 NE 12TH ST
TPN: 7227802040
2908 NE 12TH ST
TPN: 7227801776
EXISTING 1-1/2" METER
ACCNT #3168-000
HA
R
R
I
N
G
T
O
N
P
L
N
E
NE 12TH STREET
PP
P
P
P P P P
8''
C
I
W
(
4
3
5
)
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
P P
P
P P P P PPPPP P P P P P P PP
8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)
TEL
TE
L
TE
L
TEL
TEL
T
E
L
TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TELTELTELTELTELTEL
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL
T
E
L
TE
L
TE
L
TEL TEL TEL TEL
8'' CI W (565)
W
W
8'' CI W (565)
8'
'
D
I
W
(
5
6
5
)
4''
I
P
G
6'' IP G 6'' IP G 6'' IP G 6'' IP G 6'' IP G 6'' IP G6'' IP G6'' IP G
G
8'' CI W (565)8'' CI W (565)
36'' CMP ST 36'' CMP ST
12'' ST 12'' ST 12'' ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST
12
'
'
C
O
N
C
S
T
36'' CMP ST
12'' ST (ABAN)
6'
'
C
O
N
C
S
T
x
x
x
x
W
P P P
P
P
P
P
P
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
(
5
6
5
)
8'' CI W (565)8'' CI W (565)
2'' STL G (ABND)2'' STL G (ABND)
1000 LF 1100 LF 1200 LF 1300 LF 1400 LF00
A
19
00
A
20
00
A
21
00
A
22
00
A
23
PH6
PH7
PH G3
PH P4 PH P5
PPH21
GPH22
GPH23A GPH24
GPH25
PPH26
GPH27
GPH23B
12'' DI W (565)12'' DI W (565)12'' DI W (565)
7
8
9
(CONNECTION D)
CONNECTION TO
EXISTING 8" DI WATER
MAIN BY CITY FORCES
(CONNECTION Q)
CONNECTION TO
EXISTING 12" DI WATER
MAIN BY CITY FORCES
W0
2
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
W0
2
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
W0
4
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
W0
4
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
U04
U04
117
118
122
123
119
120
121 125
124
PROFILE VIEW
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
945 LF 1000 LF 1100 LF 1200 LF 1300 LF 1400 LF 1425 LF
PR
O
P
.
S
T
O
R
M
8
"
D
I
P
IE
:
3
4
9
.
6
2
APPROX. 480 LF OF 12" RJ DI PIPE
12" RJ DI WATER MAIN
117 119 122
19+65A 20+65A 21+65A 22+65A 23+65A
121
PR
O
P
.
S
T
O
R
M
8
"
D
I
P
IE
:
3
5
1
.
4
7
125
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
117
118
119
120
122
123
121
WATER MAIN NOTES (565 ZONE)
GENERAL CONSTRUCTION NOTES
WATER SERVICE NOTES
125
124
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
W01 W02 W03 W04 W05 W06 W07 W08
W1
1
W09
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
1
.
D
W
G
SHOWN
W03 20 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
PLAN VIEW
WA
T
E
R
M
A
I
N
P
L
A
N
A
N
D
P
R
O
F
I
L
E
0
3
NE
1
2
T
H
S
T
-
H
A
R
R
I
N
G
T
O
N
A
V
E
T
O
K
I
R
K
L
A
N
D
A
V
E
EXISTING STORM PIPE
SHALL BE REMOVED AS
PART OF PROPOSED
WATER MAIN INSTALLATION.
T7
8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS
8'
'
S
S
(
A
B
A
N
)
8'
'
S
S
(
A
B
A
N
)
8'
'
S
S
(
A
B
A
N
)
8'
'
P
V
C
S
S
8'
'
S
S
8'
'
S
S
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SSSSSSSS
FIRE STATION #12
1209 KIRKLAND AVE NE
TPN: 7227801450
4" DCDA W/ 3/4" METER
ACCNT #61583-001
1-1/2" IRR METER ACCNT
#61583-002
2" DOM METER ACCNT
#61583-000
1171 KIRKLAND AVE NE
TPN: 7227801406
975 HARRINGTON PL NE
TPN: 7227801405
3116 SUNSET BLVD NE
TPN: 0423059095
3002 NE SUNSET BLVD
TPN: 7227800285
KI
R
K
L
A
N
D
A
V
E
N
E
J
E
F
F
E
R
S
O
N
A
V
E
N
E
NE 12TH STREET
P P
P
P
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
P P P
P
P
PPPP
P
16'' DI W (435)16'' DI W (435)
OH
P
P
P P
P P PP P
8'' AC W (ABAN)8'' AC W (ABAN)
8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)
TE
L
TE
L
TEL TEL TELTELTELTELTELTELTEL
TEL
TE
L
TEL TEL TEL
TE
L
TEL TEL TEL TEL
TE
L
TE
L
TEL TEL TELTELTELTELTELTELTELTELTELTELTEL
TEL TEL TEL
TEL TEL
TE
L
TE
L
TE
L
TE
L
TEL TEL
TEL TEL
8'' CI W (565)8'' CI W (565)8'' CI W (565)8'' CI W (565)
W W
8'
'
D
I
W
(
5
6
5
)
4'' IP G4'' IP G 4'' IP G
4'' IP G 4'' IP G 4'' IP G
G
2'
'
I
P
G
2'
'
I
P
G
4'' IP G
6'' IP G
G
FO FO FO
12'' ST (ABAN)12'' ST (ABAN)
S
D
36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST
6
'
'
C
M
P
S
T
SD
SD
SD
SD
6''
P
V
C
S
T
6
'
'
C
O
N
C
S
T
18
'
'
C
M
P
S
T
12'' ADS ST
12'' CONC ST 12'' CONC ST
12
S
T
12
S
T
x
x
x
10
'
'
S
T
L
W
(
A
B
N
)
10
'
'
C
I
(
5
6
5
)
W
P
P
P
P
P P P P
P
P
P
CO
R
T
E
L
M
CO
R
T
E
L
M
COR TELM COR TELM
P P P P P P P P
12
'
'
D
I
W
6'
'
C
I
W
(
A
B
A
N
)
18
'
'
D
I
S
T
1
2
'
'
D
I
S
T
12'
'
S
T
12
'
'
S
T
12
'
'
S
T
12
'
'
S
T
6'
'
C
O
N
C
S
S
(
A
B
A
N
)
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
WS
PP PP
10
'
'
C
I
W
(
5
6
5
)
10
'
'
C
I
W
(
5
6
5
)
1500 LF 1600 LF 1700 LF 1800 LF00
A
24
00
A
25
00
A
26
00
A
27
00
A
28
PH9
PH10
PH11
PH12
PH12A
PH G4 PH G5
PH P6PPH29GPH30PPH31PPH32
GPH34
PPH35
PPH37
GPH38
PPH39
PPH40
12'' DI W (565)12'' DI W (565)
10
12
(CONNECTION S)
CONNECTION TO
EXISTING 12" DI WATER
MAIN BY CITY FORCES
(CONNECTION L)
CONNECTION TO
EXISTING 10" CI WATER
MAIN BY CITY FORCES
(CONNECTION K)
CONNECTION TO
EXISTING 10" CI WATER
MAIN BY CITY FORCES
11
13
14
W0
3
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
W0
3
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
W0
5
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
W0
5
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
U04
U04
(CONNECTION R)
CONNECTION TO
EXISTING 12" DI WATER
MAIN BY CITY FORCES
127 129
133
131
132
135
128
136
137
126 134
130
U04
U04
CONNECTION TO
EXISTING 4" DI WATER
MAIN BY CITY FORCES
CONNECTION TO
EXISTING 8" DI WATER
MAIN BY CITY FORCES
U04
PROFILE VIEW
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
1425 LF 1500 LF 1600 LF 1700 LF 1800 LF 1879 LF
APPROX. 454 LF OF 12" RJ DI PIPE
12" RJ DI WATER MAIN
127
129 133
24+65A 25+65A 26+65A 27+65A
126
128
135 136134
WATER MAIN NOTES (565 ZONE)
127
129
133
131
132
128
135
136
137
126
134
WATER SERVICE NOTES
130
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
W01 W02 W03 W04 W05 W06 W07 W08
W1
1
W09
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
1
.
D
W
G
SHOWN
W04 21 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
PLAN VIEW
WA
T
E
R
M
A
I
N
P
L
A
N
A
N
D
P
R
O
F
I
L
E
0
4
NE
1
2
T
H
S
T
-
H
A
R
R
I
N
G
T
O
N
A
V
E
T
O
K
I
R
K
L
A
N
D
A
V
E
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
NOTE: GENERAL CONSTRUCTION NOTES NOT
SHOWN ON THIS SHEET. SEE DWG NO. W01 FOR
WATER MAIN GENERAL CONSTRUCTION NOTES.
COORDINATE WITH COR'S CREW ON
CITY-PERFORMED REMOVAL OF
EXISTING EASTERN AND WESTERN
VALVES AND INSTALLATION OF
BLIND FLANGES. CONTRACTOR TO
REMOVE AND ABANDON EXISTING
WATER MAIN AS DIRECTED BY COR.
EXISTING STORM PIPE
SHALL BE REMOVED AS
PART OF PROPOSED
WATER MAIN INSTALLATION.
T7
8'' CP SS 8'' CP SS 8'' CP SS
8'
'
C
P
S
S
8'
'
C
P
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
8''
S
S
8''
S
S
8''
C
P
S
S
8''
C
P
S
S
SS SS
NA
TPN: 7227900018
3011 NE SUNSET BLVD
TPN: 7227900019
METER SERVICE ON NE
SUNSET BLVDNA
TPN: 722790UNKN
3123 NE SUNSET BLVD
TPN: 0423059155
1" METER ACCNT
#157203-000
1" IRR METER ACCNT
#57203
3116 NE SUNSET BLVD
TPN: 0423059095
3/4" IRR METER ACCNT
#19835-000
3002 NE SUNSET BLVD
TPN: 7227800285
METER SERVICE ON
NE SUNSET BLVD
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
P
P
16'' DI W (435)16'' DI W (435)
P P
10'' CI W (435
)
16'' DI W (435)16'' DI W (435)
P P P P
P
P
P
16'' DI W (435)
10
'
'
C
I
W
(
4
3
5
)
P
P P P P P P P P P PPPPPPPPPPPPP
P P PP
P
P
P
P
P
P
P
P
P
P
10'' CI W (435)
8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)
8'
'
A
C
W
(
A
B
A
N
)
6'
'
C
I
W
(
4
3
5
)
TEL TEL TEL
TEL TEL TEL TEL TEL
TE
L
TEL TEL TEL TEL
TEL
TEL TEL TEL TEL
TEL
TEL TE
L
TE
L
TEL TEL
TEL
T
E
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
4'' STL W (ABN)4'' STL W (ABN)4'' STL W (ABN)
10'' CI W (565)10'' CI W (565)10'' CI W (565)
W
2'' IP G 2'' IP G
4''
I
P
G
4''
I
P
G
G
4'' IP G 4'' IP G 4'' IP G
G
G
G
G
12
'
'
D
I
W
(
5
6
5
)
10'' CI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO
FO
FO
FO FO FO FO FO FO FO FO FO
12'' CONC ST 12'' CONC ST 12'' CONC ST
18
'
'
C
O
N
C
S
T
18
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
SD
12
'
'
C
O
N
C
S
T
1
2
'
'
S
T
4''
C
I
W
(
A
B
A
N
)
4''
C
I
W
(
A
B
A
N
)
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
(
5
6
5
)
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
G
G
G
12'' CONC ST
12'' CONC ST
12'' CONC ST
12'' CONC ST
1900 LF 2000 LF 2100 LF 2200 LF
00
A
29
00
A
30
00
A
31
00
A
32
PH13
PH14
PH G6
PH G7
PH G8
PH G9
PH G10
PH P7
PPH43
PPH44
GPH45
GPH47
GPH48
PPH46
PPH49
GPH50
GPH51
PPH52
PPH53
PPH56
PPH54
PPH55
PPH57
PPH59
PPH60
12'' DI W (565)
16
'
'
D
I
W
(
4
3
5
)
12'' RJ DI W (565)12'' DI W (565)
16
'
'
D
I
W
(
4
3
5
)
16
15
17
18
19
(CONNECTION T)
CONNECTION TO
EXISTING 12" DI WATER
MAIN BY CITY FORCES
(CONNECTION U)
CONNECTION TO
EXISTING 12" DI WATER
MAIN BY CITY FORCES
W0
4
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
W0
4
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
W0
6
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
W0
6
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
(CONNECTION M)
CONNECTION TO
EXISTING 10" CI WATER
MAIN BY CITY FORCES
(CONNECTION Z)
CONNECTION TO
EXISTING 16" DI WATER
MAIN BY CITY FORCES
CONNECTION TO
EXISTING 6" DI HYDRANT
BY CITY FORCES
U04
U04
U04
138
141
142
146 147
435 ZONE WATER
MAIN, SEE DETAIL
FOR PROFILE
9
10
12
14
15
139
11
144
143
U04
U04
CONNECTION TO
EXISTING 6" DI WATER
BY CITY FORCES
PIPE SHALL NOT BE INSTALLED FURTHER
EAST THAN THIS POINT PRIOR TO PRESSURE
TESTING, DISENFECTION, PIGGING AND CITY
APPROVAL. SEE DWG NO. WC06.
140
EXISTING POWER LINE TO
BE RELOCATED BY PSE
13
145
PROFILE VIEW
340'
350'
360'
370'
380'
340'
350'
360'
370'
380'
1880 LF 1900 LF 2000 LF 2100 LF 2200 LF 2285 LF
PR
O
P
.
S
T
O
R
M
1
2
"
D
I
P
IE
:
3
6
2
.
2
1
APPROX. 405 LF OF 12" RJ DI PIPE
12" RJ DI WATER MAIN
138 141
146 147
PR
O
P
.
W
A
T
E
R
1
6
"
D
I
4
3
5
CR
O
S
S
I
N
G
28+65A 29+65A 30+65A 31+65A
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS, TYP.
CLSM ENCASEMENT PER
DETAIL T4 ON DWG NO. D01
CLSM ENCASEMENT PER
DETAIL T4 ON DWG NO. D01
143
144
140
145
WATER SERVICE NOTES
138
141
142
146
147
9
13
10
12
14
15
139
11
144
143
WATER MAIN NOTES (565 ZONE)
WATER MAIN NOTES (435 ZONE)
140
145
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
W01 W02 W03 W04 W05 W06 W07 W08
W1
1
W09
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
1
.
D
W
G
SHOWN
W05 22 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
PLAN VIEW
WA
T
E
R
M
A
I
N
P
L
A
N
A
N
D
P
R
O
F
I
L
E
0
5
NE
1
2
T
H
S
T
-
K
I
R
K
L
A
N
D
A
V
E
T
O
M
O
N
R
O
E
A
V
E
NOTE: GENERAL CONSTRUCTION NOTES NOT
SHOWN ON THIS SHEET. SEE DWG NO. W01 FOR
WATER MAIN GENERAL CONSTRUCTION NOTES.
KEY PLAN
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
NO CONSTRUCTION ACTIVITIES AND/OR CLOSURE OF ROADWAY
LANES ARE PERMITTED AT THIS INTERSECTION FROM JUNE 1,
2026 TO JULY 15, 2026 PER SPECIAL PROVISIONS 1-8.0(2)
8'
'
P
V
C
S
S
8'' PVC SS
8'' PVC SS
8'' CLAY SS
8'' CLAY SS
8'' CLAY SS
8'' CLAY SS
8'' CLAY SS
8
'
'
P
V
C
S
S
1170 MONROE AVE NE
TPN: 0923059170
3233 NE 12TH ST
TPN: 7801300000
METER SERVICES ON
LYNNWOODTPN: 7227900018
3316 NE 12TH ST
TPN: 7736100015
3232 NE 12TH ST
TPN: 0423059316
3224 NE 12TH ST
TPN: 0423059169
3/4" METER ACCNT
#7720-000
3218 NE 12TH ST
TPN: 0423059182
1-1/2" METER
ACCNT #17721-00
LY
N
N
W
O
O
D
A
V
E
N
E
M
O
N
R
O
E
A
V
E
N
E
NE 12TH ST
P
P
P
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
OHP OHP
OH
P
OH
P
OH
P
OH
P
O
H
P
OHP OHP OHP OHP OHP
OHP
O
H
P
O
H
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
P
P
10'' CI W (435)10'' CI W (435)10'' CI W (435)10'' CI W (435)
10'' CI W (435)
TEL
TELTELTEL
TEL TEL TEL TEL TEL TEL
TEL
TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL
TE
L
TE
L
T
E
L
TE
L
TE
L
TE
L
4'' STL W (ABN)
10
'
'
D
I
W
(
5
6
5
)
10
'
'
D
I
W
(
5
6
5
)
W
W
6'' DI W (565)6'' DI W (565)
8'
'
C
I
W
(
5
6
5
)
4'' IP G
G
4'' IP G
2'' IP G 2'' IP G 2'' IP G 2'' IP G 2'' IP G
2'
'
I
P
G
G
G
4'
'
C
I
W
(
5
6
5
)
10'' CI W (565)10'' CI W (565)10'' CI W (565)10'' CI W (565)10'' CI W (565)10'' CI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
1
2
'
'
C
M
P
S
T
12'' ST 12'' ST
6''
C
O
N
C
S
T
12'' CONC ST (ABAN)12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
8'
'
C
M
P
S
T
8
'
'
C
M
P
S
T
FO
x
x
x
x
x
xxxxxxxxxxxx
x
x
x
x
xxxxxxxx
x x x
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
CO
R
T
E
L
M
COR TELM COR TELM
ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W
4''
C
O
N
C
S
S
4''
C
O
N
C
S
S
4''
C
O
N
C
S
S
4''
C
O
N
C
S
S
CLAY UNKNOWN SIZE SS CLAY UNKNOWN SIZE SS CLAY UNKNOWN SIZE SS CLAY UNKNOWN SIZE SS
6'
'
P
V
C
S
S
6'
'
P
V
C
S
S
4'
'
C
O
N
C
S
S
4'
'
C
O
N
C
S
S
2300 LF 2400 LF 2500 LF 2600 LF
00
A
33
00
A
34
00
A
35
00
A
36
PH16
PH17
PH18 PH19
PH20
PH21
PH22PH22A
PH G11 PH G12
PH P9
GPH61
GPH62
GPH63
GPH64
PPH67
PPH68
GPH71
12'' DI W (565)12'' DI W (565)12'' DI W (565)
20
23
W0
5
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
W0
5
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
W0
7
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
W0
7
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
(CONNECTION E)
CONNECTION TO
EXISTING 8" CI WATER
MAIN BY CITY FORCES
(CONNECTION N)
CONNECTION TO
EXISTING 10" DI WATER
MAIN BY CITY FORCES
U04 U04
148
153
154
149
150
152
CONNECTION TO
EXISTING 6" DI WATER
MAIN BY CITY FORCES
151
21
22
U04
PROFILE VIEW
355'
360'
370'
380'
390'
355'
360'
370'
380'
390'
2285 LF 2300 LF 2400 LF 2500 LF 2540 LF
PROFILE VIEW
380'
390'
400'
410'
420'
380'
390'
400'
410'
420'
2540 LF 2600 LF 2685 LF
PR
O
P
.
S
T
O
R
M
1
2
"
D
I
P
IE
:
3
9
5
.
4
6
APPROX. 255 LF OF 12" RJ DI PIPE APPROX. 145 LF OF 12" RJ DI PIPE
12" RJ DI WATER MAIN
12" RJ DI WATER MAIN
148
153
32+65A 33+65A 34+65A 35+65A
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS, TYP.
CONTRACTOR TO POTHOLE AND VERIFY
LOCATION AND DEPTH OF EXISTING SIDE SEWER.
WATER MAIN ENCASEMENT OR SIDE SEWER
RELOCATION MAY BE REQUIRED BY CITY.
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
148
153
154
149
150
152
WATER MAIN NOTES (565 ZONE)
GENERAL CONSTRUCTION NOTES
WATER SERVICE NOTES
T4
151
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
W01 W02 W03 W04 W05 W06 W07 W08
W1
1
W09
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
1
.
D
W
G
SHOWN
W06 23 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
PLAN VIEW
WA
T
E
R
M
A
I
N
P
L
A
N
A
N
D
P
R
O
F
I
L
E
0
6
NE
1
2
T
H
S
T
-
K
I
R
K
L
A
N
D
A
V
E
T
O
M
O
N
R
O
E
A
V
E
x x x x x x x
x
x
x
x
x x x x x x x x x
x
x
x x
x
x
x x x x x x x x x
x
x
x
P
P PP
P
P
PT
E
L
T
E
L
TEL TEL TEL
TEL TEL
TEL
TEL TELTEL
TEL TEL TEL TELTELTELTELTEL
TELTELTEL
TEL TEL TEL TEL TEL
TEL
P
P
P
OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
OHP
OHP
OHP OHP OHP
x
x
x
x
x
xxxxxx
x
x
x
x
TEL TEL
P
16'' CI W 16'' CI W 16'' CI W
G G G G G G G G
P
P
TEL TEL
GGGGGG
W
10'' CI W 10'' CI W 10'' CI W
16
'
'
C
I
W
16'' CI W 16'' CI WTELTELTELTELTEL
TE
L
TE
L
TE
L
16
'
'
C
I
W
x x x x x x x x x x x x
x x x
x
x x x x x
TEL
TE
L
12'' CI W 12'' CI W
8'' CLAY SS
8'' CLAY SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS
W
8'' AC W (565)
3323 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#59301-000
3317 NE 12TH ST
TPN: 0923059162
3/4" METER ACCNT
#24137-000
1204 MONROE AVE NE
TPN: 7736100055
3/4" METER ACCNT
#7801-000
3316 NE 12TH ST
TPN: 7736100015
MO
N
R
O
E
A
V
E
N
E
NE 12TH ST
OHP OHP OHP
O
H
P
O
H
P
OH
P
OH
P
OH
P
12'' CI W (435)
12'' CI W (435)12'' CI W (435)
16'' DI W (435)16'' DI W (435)16'' DI W (435)
O
H
P
O
H
P
O
H
P
O
H
P
O
H
P
OHP
OHP
OHP OHP OHP OHP
OH
P
10'' CI W (435)
TEL TEL
TEL TEL TEL
TEL TEL TELTEL
TEL
TE
L
TE
L
TE
L
TE
L
TE
L
TEL TEL TEL TEL TEL TELTELTELTELTELTELTEL
TEL TEL TEL
TEL
G G
G G G 4'' IP G
4'
'
I
P
G
4'
'
I
P
G
8'
'
D
I
W
(
5
6
5
)
W
G
G
4'' IP G
10'' CI W (565)10'' CI W (565)10'' CI W (565)
FO FOFO
x x x x x x x
x
x x
x
x
x
x x x x
x
TELTEL
PP
TELTELP
T
E
L
TELTELTEL PPP
P
T
E
L
PP
TEL
PP
3401 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#44306-000
3410 NE 12TH ST
TPN: 0423059186
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
CO
R
T
E
L
M
ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W
ABN
D
W
ABN
D
W
ABN
D
W
ABN
D
W
ABN
D
W
ABN
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
ABND WABND WABND WABND WABND WABND W
ABND WABND WABND WABND W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
3327 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#7742-000
CLAY UNKNOWN SIZE SS
6'
'
C
O
N
C
S
S
4'
'
S
S
(
A
B
A
N
)
2700 LF 2800 LF 2900 LF 3000 LF
-13 LF 0 LF
00B10
00B11
00
A
37
00
A
38
00
A
39
00
A
40
PH G13
PH G14
PH G15 PH G16
GPH74
GPH75
GPH82
12'' DI W (565)
12'' DI W (565)
12'' DI W (565)
16'' DI W
24
25
26
G G G G G G G G G
W0
8
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
W0
8
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
W0
6
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
W0
6
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
(CONNECTION F)
CONNECTION TO
EXISTING 8" DI WATER
MAIN BY CITY FORCES
U04
U04
155
156
157
158
159
160
(CONNECTION AA)
CONNECTION TO
EXISTING 16" CI WATER
MAIN BY CITY FORCES
PROFILE VIEW
405'
410'
420'
430'
440'
405'
410'
420'
430'
440'
2685 LF 2700 LF 2800 LF 2900 LF 3000 LF 3065 LF
APPROX. 380 LF OF 12" RJ DI PIPE
12" RJ DI WATER MAIN
155
157 159
36+65A 37+65A 38+65A 39+65A
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
155
156
157
158
159
160
WATER MAIN NOTES (565 ZONE)
GENERAL CONSTRUCTION NOTES
WATER SERVICE NOTES
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
W01 W02 W03 W04 W05 W06 W07 W08
W1
1
W09
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
1
.
D
W
G
SHOWN
W07 24 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
PLAN VIEW
WA
T
E
R
M
A
I
N
P
L
A
N
A
N
D
P
R
O
F
I
L
E
0
7
NE
1
2
T
H
S
T
-
M
O
N
R
O
E
A
V
E
T
O
O
L
Y
M
P
I
A
A
V
E
SEE DWG NO. W11 FOR
INFORMATION ON 435 ZONE
WATER MAIN IMPROVEMENTS
BEGIN EXISTING GAS LINE TO BE
RELOCATED BY PSE. APPROXIMATE
ALIGNMENT OF NEW GAS LINE SHOWN.
10''
C
O
N
C
S
T
x
x x x x x x x x x x x x x x x x x x x x x x
x
x
x
x
x
xxxxxxxxxx
P P P
P
TEL
TEL
TE
L
TE
L
TEL TEL TEL TEL TEL
TEL
TE
L
TEL TEL TELTELTELTEL
TEL
TEL TEL TEL
TE
L
TEL TEL TEL TEL TEL
OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
x
x
TEL
x
x
x
x
x
x
x
x
x
x
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
8'
'
C
O
N
C
S
S
8'' CONC SS 8'' CONC SS 8'' CONC SS
SS
(
A
B
N
D
)
SS
(
A
B
N
D
)
SD
TEL
8'
'
W
(
5
6
5
)
G G G G G G G G G G G G
OHP OHP OHP OHP OHP OHP OHP OHP
TEL TEL TEL TEL TEL TEL TEL TEL
TEL
TEL
TEL TEL TEL
TE
L
TE
L
G
G G G G
G G G
G G G
W W
16'' CI W
10
'
'
C
O
N
C
S
S
6'
'
P
V
C
S
S
6'
'
P
V
C
S
S
x
x
x
x
x
x
x
10'' CONC SD
10'
'
C
O
N
C
S
D
10'
'
C
O
N
C
S
D
10'
'
C
O
N
C
S
D
x x x x x x x x x x x x x x x x x x x x x x x x x x
12
'
'
C
I
W
12'' CI W
OHP
8'' CONC SS
8'' AC W (565)8'' AC W (565)8'' AC W (565)
8'' AC W (565)
NA
TP
N
:
0
4
2
3
0
5
9
2
5
1
OL
Y
M
P
I
A
A
V
E
N
E
NE 12TH ST
TELTEL
TELPP
PTEL
3417 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#54364-000
3501 NE 12TH ST
TPN: 8062900035
3/4" METER ACCNT
#7747-000
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES ON PIERCE
12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
TEL
x x
G G
TEL TEL TEL TEL
TEL
ABND W
3100 LF 3200 LF
3300 LF
100 LF 200 LF
27
5
L
F
00
A
41
00
A
42
00
A
43
PH24
PH G17 PH G18
GPH98
GPH99
12'' DI W (565)
12'' DI W (565)
16'' DI W
27
G G G G G G G G
W0
7
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
W0
7
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
W0
9
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
W0
8
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
W0
9
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
W0
8
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
U04
164
165
161
(CONNECTION G)
CONNECTION TO
EXISTING 8" DI WATER
MAIN BY CITY FORCES
12'' DI W (565)162
163
PROFILE VIEW
415'
420'
430'
440'
450'
415'
420'
430'
440'
450'
3065 LF 3100 LF 3200 LF 3300 LF 3355 LF
APPROX. 290 LF OF 12" RJ DI PIPE
12" RJ DI WATER MAIN 164
40+65A 41+65A 42+63A
161 162 163
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
164
165
161
WATER MAIN NOTES (565 ZONE)
GENERAL CONSTRUCTION NOTES
WATER SERVICE NOTES
162
163
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
W01 W02 W03 W04 W05 W06 W07 W08
W1
1
W09
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
1
.
D
W
G
SHOWN
W08 25 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
PLAN VIEW
WA
T
E
R
M
A
I
N
P
L
A
N
A
N
D
P
R
O
F
I
L
E
0
8
NE
1
2
T
H
S
T
-
M
O
N
R
O
E
A
V
E
T
O
O
L
Y
M
P
I
A
A
V
E
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
SEE DWG NO. W11 FOR
INFORMATION ON 435 ZONE
WATER MAIN IMPROVEMENTS
END EXISTING GAS LINE
RELOCATION BY PSE
xxxxxxx
TEL TEL
G
G
OH
P
OH
P
x
x
x
G
G
8'' CONC SS 8'' CONC SS 8'' CONC SS8'' CONC SS 8'' CONC SS
8'
'
C
O
N
C
S
S
G
OHP OHP
G GGG
8'' AC W (565)
PI
E
R
C
E
P
L
N
E
3515 NE 12TH ST
TPN: 8062900040
3/4" METER ACCNT
#46676-000
8'
'
C
O
N
C
S
S
8'' CONC SS 8'' CONC SS 8'' CONC SS
8'
'
C
O
N
C
S
S
SDSDSDSD
12'' CONC ST 12'' CONC ST 12'' CONC ST
OHP OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OHP OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
x
x
OH
P
OH
P
OH
P
OH
P
x
8'' AC W (565)8'' AC W (565)8'' AC W (565)8'' AC W (565)
OH
P
OH
P
OH
P
OH
P
OH
P
O
H
P
O
H
P
OHP OHP
W
1204 PIERCE PL NE
TPN:0911500160
METER SERVICES ON PIERCE
1203 QUEEN AVE NE
TPN:0911500105
METER SERVICES ON QUEEN
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES
ON QUEEN
1159 PIERCE AVE NE
TPN: 8062900005
3607 NE 12TH ST
TPN: 0923059205
3/4" METER ACCNT
#45388-000
3613 NE 12TH ST
TPN: 0923059252
8
D
I
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
8
D
I
W
(
5
6
5
)
8
D
I
W
(
5
6
5
)
G
G G G G G G G G G G G
TEL TELTEL
TEL
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL TEL
TEL
xxxxxxx TOP
TOP
x x x xxxxx
xxxxxxxx
x
xxxxxxxxxxxxxxxxxx
TOE
TOE TOE TOE
x x x x x
G G
TEL
TEL
TE
L
QU
E
E
N
A
V
E
N
E
NE 12TH ST
PI
E
R
C
E
A
V
E
N
E
10
C
O
N
C
S
T
12'' CONC ST 12'' CONC ST 12'' CONC ST
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES
ON PIERCE
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
8'
'
D
I
W
(
5
6
5
)
12'' DI W (565)12'' DI W (565)12'' DI W (565)
3700 LF
3400
L
F
3500 LF 3600 LF
00
A
44
00
A
45
00
A
46
00
A
47
PH G19
GPH109
GPH111
12'' DI W (565)
28
W0
8
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
W0
8
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
CONNECTION TO
EXISTING 12"x8" DI
CROSS BY CITY FORCES
(CONNECTION H)
CONNECTION TO
EXISTING 8" DI WATER
MAIN BY CITY FORCES
(CONNECTION V)
CONNECTION TO
EXISTING 12" DI WATER
MAIN BY CITY FORCES
168 169
170
171 172
173
U04
U04
GATE VALVE REMOVAL AND
BLIND FLANGE INSTALLATION
BY CITY FORCES. CONCRETE
BLOCKING INSTALLATION BY
CONTRACTOR.
166
167
PROFILE VIEW
405'
410'
420'
430'
440'
405'
410'
420'
430'
440'
3355 LF 3400 LF 3500 LF 3600 LF 3700 LF
APPROX. 336 LF OF 12" RJ DI PIPE
12" RJ DI WATER MAIN 168
170
172
43+62A 44+61A 45+61A
173
166 167
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
168
169
170
171
172
173
WATER MAIN NOTES (565 ZONE)
GENERAL CONSTRUCTION NOTES
WATER SERVICE NOTES
167
166
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
W01 W02 W03 W04 W05 W06 W07 W08
W1
1
W09
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
1
.
D
W
G
SHOWN
W09 26 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
PLAN VIEW
WA
T
E
R
M
A
I
N
P
L
A
N
A
N
D
P
R
O
F
I
L
E
0
9
NE
1
2
T
H
S
T
-
O
L
Y
M
P
I
A
A
V
E
T
O
Q
U
E
E
N
A
V
E
10
'
'
D
I
W
(
5
6
5
)
10
'
'
D
I
W
(
5
6
5
)
S
D
S
D
8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
1409 & 1417 MONROE AVE NE
TPN: 0423059104
3/4" METER ACCNT #7730-000
1408 MONROE AVE NE
TPN: 7736100030
3/4" METER ACCNT
#7809-000
1400 MONROE AVE NE
TPN: 7736100035
3/4" METER ACCNT
#7808-000
1324 MONROE AVE NE
TPN: 7736100036
3/4" METER ACCNT
#7807-000
1333 MONROE AVE NE
TPN: 0423059111
3/4" METER ACCNT
#57275-000
1401 MONROE AVE NE
TPN: 0423059126
3/4" METER ACCNT
#28758-000
1416 MONROE AVE NE
TPN: 7736100020
NA
TP
N
:
0
4
2
3
0
5
T
R
C
T
NA
TPN: 7736100025
N
E
S
U
N
S
E
T
B
L
V
D
MONROE AVE. NE
P
P
P P P PPP
P
P
P
P
OHP OHP OHP OHP OHP
OH
P
OHP
O
H
P
O
H
P
O
H
P
O
H
P
OH
P
OHP
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
TEL TEL
TEL
TEL TEL TEL TEL TEL
TE
L
T
E
L
TEL
TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL
TEL
TEL TEL
TEL TELTELTEL TEL TEL TEL
TEL TEL TEL
TEL
TE
L
TE
L
TE
L
TE
L
TE
L
10'' DI W (565)10'' DI W (565)10'' DI W (565)
4'' IP G
4'' IP G 4'' IP G 4'' IP G 4'' IP G 4'' IP G
4'' IP G
4'
'
D
I
W
(
5
6
5
)
W
W W
W
W
W
W
W
W
W
W
W
G
G
G
4'' CI W (565)4'' CI W (565)
G
G
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
x
x
xxxxxxxxxx
x
xx
x
x
xxx
x
x
x
x
W
TEL TEL TEL TEL TEL
13
1
5
M
O
N
R
O
E
A
V
E
N
E
TP
N
:
7
7
3
6
1
0
0
0
0
3
-11 LF 0 LF
100 LF 200 LF 290 LF
00
B
15
00
B
16
00
B
17
00
B
18
00
B
19
PH G21
PH P10
PH P11
GPH114
PPH115
GPH116
PPH117 GPH118
8'' DI W (565)8'' DI W (565)
(CONNECTION I)
CONNECTION TO
EXISTING 8" DI WATER
MAIN BY CITY FORCES
(CONNECTION J)
CONNECTION TO
EXISTING 10" DI WATER
MAIN BY CITY FORCES
174
175
176
177
U04
U04
PROFILE VIEW
390'
400'
410'
420'
430'
390'
400'
410'
420'
430'
-10 LF 0 LF 100 LF 200 LF 300 LF
APPROX. 272 LF OF 8" RJ DI PIPE
8" RJ DI WATER MAIN174175176
177
14+88B 15+57B 16+57B
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
174
175
176
177
WATER MAIN NOTES (565 ZONE)
GENERAL CONSTRUCTION NOTES
WATER SERVICE NOTES
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
W01 W02 W03 W04 W05 W06 W07 W08
W1
1
W09
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
1
.
D
W
G
SHOWN
W10 27 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
PLAN VIEW
WA
T
E
R
M
A
I
N
P
L
A
N
A
N
D
P
R
O
F
I
L
E
1
0
MO
N
R
O
E
A
V
E
N
E
-
1
2
T
H
S
T
T
O
S
U
N
S
E
T
B
L
V
D
10''
C
O
N
C
S
T
x
x x x x x x x x
x
x
x x
x
x x x x x x x x x x x x x x x x x x x x x x x
x
x
x
x
x
xxxxxxxxxx
P P P
PP
P
P
TEL
TEL
TE
L
TE
L
T
E
L
T
E
L
TEL
TEL TEL TEL TEL TEL TEL TEL TEL
TEL
TE
L
TEL TEL TELTELTELTEL
TEL
TEL TEL TEL
TE
L
TEL TEL TEL TEL TEL TEL TEL TEL
TEL
TEL
P
P
OHP OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
x
x
TEL
x
x
x
x
x
x
x
x
x
x
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
8'
'
C
O
N
C
S
S
8'' CONC SS 8'' CONC SS 8'' CONC SS
SS
(
A
B
N
D
)
SS
(
A
B
N
D
)
SD
TEL TEL TEL
8'
'
W
(
5
6
5
)
16'' CI W
G G G G G G G G G G G G G G G G
OHP OHP OHP OHP OHP OHP OHP OHPTELTELTELTELTELTELTELTELTELTEL
TEL
TEL
TEL TEL TEL
TE
L
TE
L
G
G G G G G
G G G
G G G
G
W
W W
10'' CI W
16
'
'
C
I
W
16'' CI W 16'' CI W
10
'
'
C
O
N
C
S
S
6'
'
P
V
C
S
S
6'
'
P
V
C
S
S
TELTELTEL
x
x
x
x
x
x
x
16
'
'
C
I
W
10'' CONC SD
10'
'
C
O
N
C
S
D
10'
'
C
O
N
C
S
D
10'
'
C
O
N
C
S
D
x x x
x x x
x
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
12
'
'
C
I
W
12'' CI W 12'' CI W 12'' CI W
OHP
8'' CONC SS 8'' CONC SS
8'' AC W (565)8'' AC W (565)8'' AC W (565)
8'' AC W (565)
NA
TP
N
:
0
4
2
3
0
5
9
2
5
1
OL
Y
M
P
I
A
A
V
E
N
E
NE 12TH STNE 12TH ST
TELTEL
PP
TELTELP
T
E
L
TELTELTELTELPPPP
P
T
E
L
PP
TELTEL
PP
3401 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#44306-000
3417 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#54364-000
3501 NE 12TH ST
TPN: 8062900035
3/4" METER ACCNT
#7747-000
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES ON PIERCE
12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
TEL
x x
G G
TEL TEL TEL TEL
TEL
ABN
D
W
ABN
D
W
ABN
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
ABND W
ABND WABND WABND WABND W
AB
N
D
W
3000 LF 3100 LF 3200 LF
3300 LF
-13 LF 0 LF 100 LF 200 LF
27
5
L
F
00
A
40
00
A
41
00
A
42
00
A
43
PH24
PH G16
PH G17 PH G18
GPH98
GPH99
12'' DI W (565)
12'' DI W (565)
16'' DI W 16'' DI W
G G G G G G G G G G G G
16
17
18
19
20
U04(CONNECTION AB)
CONNECTION TO
EXISTING 16" DI WATER
MAIN BY CITY FORCES
U04
(CONNECTION W)
CONNECTION TO
EXISTING 12" CI WATER
MAIN BY CITY FORCES
12'' DI W (565)
29
PROFILE VIEW
410'
420'
430'
440'
450'
410'
420'
430'
440'
450'
-15 LF 0 LF 100 LF 200 LF 275 LF
PROFILE VIEW
410'
420'
430'
440'
450'
410'
420'
430'
440'
450'
-40 LF 0 LF 10 LF
APPROX. 268 LF OF 16" RJ DI PIPE
16" RJ DI WATER MAIN
201916
39+64A 40+64A 41+64A
17
17
18
APPROX. 31 LF OF 16" RJ DI PIPE
40+68A40+67A
12" RJ DI
WATER MAIN
29
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
17
18
19
20
16
WATER MAIN NOTES (565 ZONE)
GENERAL CONSTRUCTION NOTES
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
W01 W02 W03 W04 W05 W06 W07 W08
W1
1
W09
KEY PLAN
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
1
.
D
W
G
SHOWN
W11 28 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
PLAN VIEW
WA
T
E
R
M
A
I
N
P
L
A
N
A
N
D
P
R
O
F
I
L
E
1
1
NE
1
2
T
H
S
T
-
M
O
N
R
O
E
A
V
E
T
O
O
L
Y
M
P
I
A
A
V
E
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
W12
FIRE HYDRANT - STA 10+58A
310'
320'
330'
340'
350'
310'
320'
330'
340'
350'
-25 LF 0 LF 45 LF
CONNECTION TO EXISTING - STA 17+92A
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
-30 LF 0 LF 50 LF
435 ZONE CONNECTION TO EXISTING
300'
310'
320'
330'
340'
300'
310'
320'
330'
340'
-10 LF 0 LF 50 LF
3 5FIRE HYDRANT - STA 14+30A
320'
330'
340'
350'
360'
320'
330'
340'
350'
360'
-40 LF 0 LF 20 LF
104105
109110
112113 114
4CONNECTION TO EXISTING - STA 9+81A
300'
310'
320'
330'
340'
300'
310'
320'
330'
340'
0 LF 60 LF
2
1
3 637
1
12" DI
8" DI
16" DI
8" DI 12" DI
8" DI
6" DI
6" DI
4 5
2
CONNECTION TO EXISTING - STA 21+14A
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
-20 LF 0 LF 30 LF
CONNECTION TO EXISTING - STA 23+37A
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
-20 LF 0 LF 30 LF
CONNECTION TO EXISTING - STA 18+88A
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
-30 LF 0 LF 15 LF
FIRE HYDRANT - STA 21+65A
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
-15 LF 0 LF 40 LF
76 8 9
115116 118117 119 120
122
123
8" DI
8" DI
6" DI
12" DI
124
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
2
.
D
W
G
SHOWN
WX01 29 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
WA
T
E
R
M
A
I
N
C
R
O
S
S
S
E
C
T
I
O
N
S
0
1
XXXSEE WATER MAIN PLAN AND PROFILE SHEETS (DWG NOS. W01-W11) FOR & KEYNOTE INFORMATIONXX
GENERAL NOTE:
REMOVE ABANDONED OR TO BE ABANDONED PIPE AS NECESSARY TO CONSTRUCT PROPOSED IMPROVEMENTS.
COORDINATE PHASING WITH COR FOR ANY REMOVAL OF TO BE ABANDONED PIPES.
NOTE: ALL SIDE SEWER ELEVATIONS ARE APPROXIMATED. NO
AS BUILT OR SURVEYED INVERT ELEVATIONS ARE GIVEN.
CONNECTION TO EXISTING - STA 24+56A
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
-30 LF 0 LF 30 LF
CONNECTION TO EXISTING - STA 27+29A
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
-65 LF 0 LF 75 LF
CONNECTION TO EXISTING - STA 25+67A
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
-35 LF 0 LF 15 LF
10 12
127 128
131 129 132 133
11
12" DI
12" DI
4" DI
10" DI
12" DI
10" DI
12" DI
130
CONNECTION TO EXISTING - STA 29+35A
340'
350'
360'
370'
380'
340'
350'
360'
370'
380'
-20 LF 0 LF 30 LF
CONNECTION TO EXISTING - STA 29+95A
340'
350'
360'
370'
380'
340'
350'
360'
370'
380'
-50 LF 0 LF 20 LF
CONNECTION TO EXISTING - STA 27+74A
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
-35 LF 0 LF 15 LF
FIRE HYDRANT - STA 27+88A
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
-40 LF 0 LF 15 LF
PR
O
P
.
S
T
O
R
M
1
8
"
P
P
IE
:
3
5
6
.
8
6
PR
O
P
.
S
T
O
R
M
1
8
"
D
I
P
IE
:
3
6
0
.
1
5
15 16
136137
135
138 139 141142
1413
PR
O
P
.
S
T
O
R
M
1
8
"
P
P
IE
:
3
5
2
.
1
1
8" DI 6" DI
12" DI
12" DI
PR
O
P
.
S
T
O
R
M
1
8
"
P
P
IE
:
3
5
2
.
5
1
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
2
.
D
W
G
SHOWN
WX02 30 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
WA
T
E
R
M
A
I
N
C
R
O
S
S
S
E
C
T
I
O
N
S
0
2
XXXSEE WATER MAIN PLAN AND PROFILE SHEETS (DWG NOS. W01-W11) FOR & KEYNOTE INFORMATIONXX
NOTE: ALL SIDE SEWER ELEVATIONS ARE APPROXIMATED. NO
AS BUILT OR SURVEYED INVERT ELEVATIONS ARE GIVEN.
GENERAL NOTE:
REMOVE ABANDONED OR TO BE ABANDONED PIPE AS NECESSARY TO CONSTRUCT PROPOSED IMPROVEMENTS.
COORDINATE PHASING WITH COR FOR ANY REMOVAL OF TO BE ABANDONED PIPES.
CONNECTION TO EXISTING - STA 30+29A
340'
350'
360'
370'
380'
340'
350'
360'
370'
380'
-110 LF -100 LF 0 LF 100 LF 120 LF
FIRE HYDRANT - STA 31+39A
350'
360'
370'
380'
390'
350'
360'
370'
380'
390'
-35 LF 0 LF 35 LF
CONNECTION TO EXISTING - STA 31+65A
350'
360'
370'
380'
390'
350'
360'
370'
380'
390'
-35 LF 0 LF 35 LF
PR
O
P
.
S
T
O
R
M
1
8
"
D
I
P
IE
:
3
6
0
.
8
0
PR
O
P
.
S
T
O
R
M
1
2
"
D
I
P
IE
:
3
6
3
.
3
0
PR
O
P
.
S
T
O
R
M
1
2
"
D
I
P
IE
:
3
6
3
.
8
3
PR
O
P
.
W
A
T
E
R
1
2
"
D
I
CR
O
S
S
I
N
G
17 18 19
146
147
913 10 11
12
14
15
16" DI16" DI
10" DI
6" DI
6" DI
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS. TYP.
6" DI
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS. TYP.
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS. TYP.
EXISTING POWER LINE TO
BE RELOCATED BY PSE
CONNECTION TO EXISTING - STA 33+24A
350'
360'
370'
380'
390'
350'
360'
370'
380'
390'
-10 LF 0 LF 75 LF
CONNECTION TO EXISTING - STA 35+53A
380'
390'
400'
410'
420'
380'
390'
400'
410'
420'
-15 LF 0 LF 50 LF
CONNECTION TO EXISTING FIRE SPRINKLER SERVICE
350'
360'
370'
380'
390'
350'
360'
370'
380'
390'
-30 LF 0 LF 15 LF
PR
O
P
.
S
T
O
R
M
1
2
"
D
I
P
IE
:
3
7
1
.
0
3
6" MIN.
FIRE HYDRANT - LYNNWOOD AVE
350'
360'
370'
380'
390'
350'
360'
370'
380'
390'
-45 LF 0 LF 15 LF
20 23
148 149
153 154
150
152
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS. TYP.
12" DI 8" DI
10" DI
CLSM
ENCASEMENT
T4
149
6" DI
21
150
22
6" DI
151
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
2
.
D
W
G
SHOWN
WX03 31 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
WA
T
E
R
M
A
I
N
C
R
O
S
S
S
E
C
T
I
O
N
S
0
3
XXXSEE WATER MAIN PLAN AND PROFILE SHEETS (DWG NOS. W01-W11) FOR & KEYNOTE INFORMATIONXX
NOTE: ALL SIDE SEWER ELEVATIONS ARE APPROXIMATED. NO
AS BUILT OR SURVEYED INVERT ELEVATIONS ARE GIVEN.
GENERAL NOTE:
REMOVE ABANDONED OR TO BE ABANDONED PIPE AS NECESSARY TO CONSTRUCT PROPOSED IMPROVEMENTS.
COORDINATE PHASING WITH COR FOR ANY REMOVAL OF TO BE ABANDONED PIPES.
CONNECTION TO EXISTING - STA 37+08A
400'
410'
420'
430'
440'
400'
410'
420'
430'
440'
-50 LF 0 LF 15 LF
CONNECTION TO EXISTING - STA 39+57A
410'
420'
430'
440'
450'
410'
420'
430'
440'
450'
-70 LF 0 LF 20 LF
CONNECTION TO EXISTING - STA 42+11A
420'
430'
440'
450'
460'
420'
430'
440'
450'
460'
-15 LF 0 LF 65 LF
FIRE HYDRANT - STA 39+37A
410'
420'
430'
440'
450'
410'
420'
430'
440'
450'
-40 LF 0 LF 10 LF
PR
O
P
.
S
T
O
R
M
1
2
"
D
I
P
IE
:
4
1
9
.
8
6
PR
O
P
.
S
T
O
R
M
1
2
"
D
I
P
IE
:
4
3
5
.
5
4
PR
O
P
.
S
T
O
R
M
1
2
"
D
I
P
IE
:
4
3
5
.
2
8
6" MIN.
24 25 26 27
155156
157158
164 165
159160
8" DI
6" DI 12" DI16" DI
8" DI
CONNECTION TO EXISTING - STA 45+16A
410'
420'
430'
440'
450'
410'
420'
430'
440'
450'
-20 LF 0 LF 20 LF
28
170 171
8" DI
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
2
.
D
W
G
SHOWN
WX04 32 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
WA
T
E
R
M
A
I
N
C
R
O
S
S
S
E
C
T
I
O
N
S
0
4
XXXSEE WATER MAIN PLAN AND PROFILE SHEETS (DWG NOS. W01-W11) FOR & KEYNOTE INFORMATIONXX
NOTE: ALL SIDE SEWER ELEVATIONS ARE APPROXIMATED. NO
AS BUILT OR SURVEYED INVERT ELEVATIONS ARE GIVEN.
GENERAL NOTE:
REMOVE ABANDONED OR TO BE ABANDONED PIPE AS NECESSARY TO CONSTRUCT PROPOSED IMPROVEMENTS.
COORDINATE PHASING WITH COR FOR ANY REMOVAL OF TO BE ABANDONED PIPES.
ED
M
O
N
D
S
A
V
E
N
E
NE 12TH STREETAPPROX. STA 9+90.4A, 13.6' L, PROVIDE:
(1) - 16" x 12" DI TEE (FLxFL) WITH
CONCRETE BLOCKING
(1) - 12" GATE VALVE (FLxRJ)
(1) - 12" DI PLUG
(2) - 16" BUTTERFLY VALVE (FLxRJ)
(2) - 16" DI LONG BODY SLEEVE, (RJxRJ)
APPROX. STA 9+79.8A, 31.9' R, PROVIDE:
(1) - 8" DI CAP, WITH 2" THREADED TAP,
WITH TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
APPROX. STA 9+79.7A, 41.6' R, PROVIDE:
(1) - 8" DI CAP, WITH TEMPORARY
CONCRETE BLOCKING
APPROX. STA 9+62.0A, 14.1' L, PROVIDE:
(1) - 12" GATE VALVE (RJxRJ)
(1) - 12" DI PLUG, WITH 2" THREADED TAP,
WITH TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
APPROX. STA 9+80.5A, 13.8' L, PROVIDE:
(1) - 12" x 8" DI TEE (RJxFL) WITH
CONCRETE BLOCKING
(1) - 8" GATE VALVE (FLxRJ)
(1) - 12" DI PLUG
APPROX. STA 9+53.7A, 14.2' L, PROVIDE:
(1) - 12" DI CAP, WITH 2" THREADED TAP,
WITH TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
ED
M
O
N
D
S
A
V
E
N
E
NE 12TH STREET
APPROX. STA 10+05.7A, 27.9' R, PROVIDE:
(1) - 12" x 4" DI TEE (RJxFL) WITH CONCRETE BLOCKING
(1) - 2" PERMANENT BLOW-OFF ASSEMBLY, PER COR STD. PLAN 340.1
(1) - 12" DI PLUG WITH CONCRETE BLOCKING
INSERT POLYPIG INSIDE NEW 12" PIPE ON
EAST SIDE OF NEW 45° VERTICAL BEND
ED
M
O
N
D
S
A
V
E
N
E
NE 12TH STREET
APPROX. STA 9+85.4A, 13.7' L, PROVIDE:
(1) - 12" DI LONG BODY SLEEVE, (RJxRJ)
APPROX. STA 9+79.8A, 33.4' R, PROVIDE:
(1) - 8" DI LONG BODY SLEEVE, (RJxRJ)
(1) - 8" TRANSITION COUPLING (DI TO CI)
APPROX. STA 9+58.5A, 14.1' L, PROVIDE:
(1) - 12" x 8" DI REDUCER (RJxRJ)
(1) - 8" TRANSITION COUPLING (DI TO AC)
(CONNECTION A)
CONNECTION TO EXISTING 8" CI
WATER MAIN BY CITY FORCES
(CONNECTION X)
CONNECTION TO EXISTING 16" DI
WATER MAIN BY CITY FORCES
(CONNECTION O)
CONNECTION TO
EXISTING 8" AC WATER
MAIN BY CITY FORCES
ED
M
O
N
D
S
A
V
E
N
E
NE 12TH STREET
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
5
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
3
.
D
W
G
SHOWN
WC01 33 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
POTENTIAL TESTING CONFIGURATION (565 ZONE)CONNECTIONS A, O, & X: POTENTIAL TESTING CONFIGURATION (435 ZONE)
CONNECTIONS A, O, & X: FINAL CONFIGURATION (435 ZONE)FINAL CONFIGURATION (565 ZONE)
WA
T
E
R
M
A
I
N
T
E
S
T
I
N
G
A
N
D
F
I
N
A
L
C
O
N
N
E
C
T
I
O
N
CO
N
F
I
G
U
R
A
T
I
O
N
S
0
1
NE
1
2
T
H
S
T
-
E
D
M
O
N
D
S
A
V
E
I
N
T
E
R
S
E
C
T
I
O
N
NOTE: THESE POTENTIAL TESTING AND FINAL CONFIGURATIONS ARE PROVIDED AS ONE WAY TO COMPLETE THE NECESSARY TESTING AND PHASING OF THE WORK. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS FOR ALL CONNECTIONS
TO EXISTING AND ADJUST AS NECESSARY TO MEET SITE CONDITIONS. FURTHER, THE CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND APPURTENANCES, WHETHER SHOWN AND/OR CALLED OUT HEREIN OR NOT, AS NECESSARY TO
COMPLETE THE RECONNECTIONS IN A FULLY TESTED AND OPERATIONAL MANNER. DEVIATIONS FROM THESE CONFIGURATIONS MAY EXIST ELSEWHERE WITHIN THE PLANS AND SHALL SUPERSEDE WHAT IS SHOWN WITHIN DWG NOS. WC01-WC14.
REMOVE EXISTING 12" AC WATER
MAIN AS NECESSARY TO INSTALL
PROPOSED WATER MAIN
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
NE 12TH STREET
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
NE 12TH STREET
APPROX. STA 17+91.7A, 9.4' L, PROVIDE:
(1) - 8" DI CAP, WITH TEMPORARY
CONCRETE BLOCKING
APPROX. STA 17+82.9A, 28.4' R, PROVIDE:
(1) - 12" DI 45° BEND (RJxRJ) WITH CONCRETE BLOCKING
(1) - 12" DI PLUG, WITH 2" THREADED TAP, WITH TEMPORARY
CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
APPROX. STA 17+91.5A, 31.3' L, PROVIDE:
INSTALL STRADDLE BLOCK ON EXISTING
WATER MAIN WITH SHACKLE RODS TO
RESTRAIN PROPOSED BEND
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
NE 12TH STREET
APPROX. STA 17+85.1A, 5.0' L, PROVIDE:
(1) - 16" DI LONG BODY SLEEVE, (RJxRJ)
APPROX. STA 17+98.6A, 5.0' L, PROVIDE:
(1) - 16" DI LONG BODY SLEEVE, (RJxRJ)
(CONNECTION Y)
CONNECTION TO
EXISTING 16" DI WATER
MAIN BY CITY FORCES
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
NE 12TH STREET
APPROX. STA 17+82.9A, 39.8' R, PROVIDE:
(1) - 12" DI LONG BODY SLEEVE, (RJxRJ)
(1) - 12" DI CAP
APPROX. STA 17+91.7A, 11.4' L, PROVIDE:
(2) - 8" DI VERTICAL 11-1/4° BEND (RJxRJ)
(1) - 8" TRANSITION COUPLING (DI TO CI)
(1) - 8" DI CAP
(CONNECTION B)
CONNECTION TO EXISTING 8" CI
WATER MAIN BY CITY FORCES
(CONNECTION P)
CONNECTION TO EXISTING 12" DI
WATER MAIN BY CITY FORCES
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
3
.
D
W
G
SHOWN
WC02 34 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
CONNECTION Y: FINAL CONFIGURATION (435 ZONE)CONNECTIONS B & P: FINAL CONFIGURATION (565 ZONE)
CONNECTIONS B & P: POTENTIAL TESTING CONFIGURATION (565 ZONE)CONNECTION Y: POTENTIAL TESTING CONFIGURATION (435 ZONE)
WA
T
E
R
M
A
I
N
T
E
S
T
I
N
G
A
N
D
F
I
N
A
L
C
O
N
N
E
C
T
I
O
N
CO
N
F
I
G
U
R
A
T
I
O
N
S
0
2
NE
1
2
T
H
S
T
-
H
A
R
R
I
N
G
T
O
N
A
V
E
I
N
T
E
R
S
E
C
T
I
O
N
NOTE: THESE POTENTIAL TESTING AND FINAL CONFIGURATIONS ARE PROVIDED AS ONE WAY TO COMPLETE THE NECESSARY TESTING AND PHASING OF THE WORK. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS FOR ALL CONNECTIONS
TO EXISTING AND ADJUST AS NECESSARY TO MEET SITE CONDITIONS. FURTHER, THE CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND APPURTENANCES, WHETHER SHOWN AND/OR CALLED OUT HEREIN OR NOT, AS NECESSARY TO
COMPLETE THE RECONNECTIONS IN A FULLY TESTED AND OPERATIONAL MANNER. DEVIATIONS FROM THESE CONFIGURATIONS MAY EXIST ELSEWHERE WITHIN THE PLANS AND SHALL SUPERSEDE WHAT IS SHOWN WITHIN DWG NOS. WC01-WC14.
NE 12TH STREET
APPROX. STA 18+87.7A, 0.8' R, PROVIDE:
(1) - 12" x 8" DI TEE (FLxFL) WITH CONCRETE BLOCKING
(1) - 12" DI ADAPTER (RJxFL)
(1) - 12" GATE VALVE (FLxRJ)
(1) - 8" GATE VALVE (FLxRJ)
(1) - 8" DI PLUG, WITH TEMPORARY CONCRETE
BLOCKING
NE 12TH STREET
APPROX. STA 21+13.8A, 0.9' R, PROVIDE:
(1) - 12" x 8" DI TEE (RJxFL) WITH CONCRETE BLOCKING
(1) - 8" GATE VALVE (FLxRJ)
(1) - 8" DI PLUG, WITH TEMPORARY CONCRETE
BLOCKING
NE 12TH STREET
APPROX. STA 18+87.6A, 9.9' L, PROVIDE:
(2) - 8" DI VERTICAL 11-1/4° BEND (RJxRJ)
(1) - 8" DI LONG BODY SLEEVE, (RJxRJ)
(2) - 8" DI CAP
(CONNECTION C)
CONNECTION TO
EXISTING 8" DI WATER
MAIN BY CITY FORCES
NE 12TH STREET
APPROX. STA 21+13.7A, 6.8' R, PROVIDE:
(2) - 8" DI 45° BEND (RJxRJ) WITH CONCRETE BLOCKING, ROLLED
TO ACHIEVE VERTICAL AND HORIZONTAL ALIGNMENT
(1) - 8" DI LONG BODY SLEEVE, (RJxRJ)
(1) - 8" DI CAP
(CONNECTION D)
CONNECTION TO EXISTING 8" DI
WATER MAIN BY CITY FORCES
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
3
.
D
W
G
SHOWN
WC03 35 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CONNECTION C: FINAL CONFIGURATION (565 ZONE)CONNECTION D: FINAL CONFIGURATION (565 ZONE)
CONNECTION D: POTENTIAL TESTING CONFIGURATION (565 ZONE)CONNECTION C: POTENTIAL TESTING CONFIGURATION (565 ZONE)
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
WA
T
E
R
M
A
I
N
T
E
S
T
I
N
G
A
N
D
F
I
N
A
L
C
O
N
N
E
C
T
I
O
N
CO
N
F
I
G
U
R
A
T
I
O
N
S
0
3
NE
1
2
T
H
S
T
-
H
A
R
R
I
N
G
T
O
N
A
V
E
T
O
H
A
R
R
I
N
G
T
O
N
P
L
NOTE: THESE POTENTIAL TESTING AND FINAL CONFIGURATIONS ARE PROVIDED AS ONE WAY TO COMPLETE THE NECESSARY TESTING AND PHASING OF THE WORK. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS FOR ALL CONNECTIONS
TO EXISTING AND ADJUST AS NECESSARY TO MEET SITE CONDITIONS. FURTHER, THE CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND APPURTENANCES, WHETHER SHOWN AND/OR CALLED OUT HEREIN OR NOT, AS NECESSARY TO
COMPLETE THE RECONNECTIONS IN A FULLY TESTED AND OPERATIONAL MANNER. DEVIATIONS FROM THESE CONFIGURATIONS MAY EXIST ELSEWHERE WITHIN THE PLANS AND SHALL SUPERSEDE WHAT IS SHOWN WITHIN DWG NOS. WC01-WC14.
NE 12TH STREET
HAR
R
I
N
G
T
O
N
P
L
N
E
APPROX. STA 23+31.7A, 10.6' R, PROVIDE:
(1) - 12" DI 11-1/4° BEND (RJxRJ) WITH CONCRETE BLOCKING
(1) - 12" DI PLUG, WITH 2" THREADED TAP, WITH
TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
JE
F
F
E
R
S
O
N
A
V
E
N
E
NE 12TH STREET
NE 12TH STREET
APPROX. STA 24+55.6A, 0.9' R, PROVIDE:
(1) - 12" DI CROSS (FLxFL)
(4) - 12" GATE VALVE (FLxRJ)
(2) - 12" DI PLUG, WITH TEMPORARY CONCRETE BLOCKING
NE 12TH STREET
HAR
R
I
N
G
T
O
N
P
L
N
E
APPROX. STA 23+29.8A, 13.8' R, PROVIDE:
(2) - 12" DI VERTICAL 45° BEND (RJxRJ)
WITH CONCRETE BLOCKING
(1) - 12" DI LONG BODY SLEEVE, (RJxRJ)
(CONNECTION Q)
CONNECTION TO EXISTING 12" DI
WATER MAIN BY CITY FORCES
JE
F
F
E
R
S
O
N
A
V
E
N
E
NE 12TH STREET
NE 12TH STREET
APPROX. STA 24+61.9A, 11.9' L, PROVIDE:
(2) - 8" DI BLIND FLANGE, REMOVE GATE VALVE
ON TEE AND REPLACE WITH BLIND FLANGE
(2) - 8" DI CAP
APPROX. STA 24+55.6A, 3.3' L, PROVIDE:
(2) - 12" DI 45° BEND ROLLED TO ACHIEVE
VERTICAL AND HORIZONTAL ALIGNMENT
(RJxRJ) WITH CONCRETE BLOCKING
(1) - 12" DI LONG BODY SLEEVE, (RJxRJ)
APPROX. STA 24+55.6A, 6.9' R, PROVIDE:
(2) - 12" DI 45° BEND ROLLED TO ACHIEVE VERTICAL
AND HORIZONTAL ALIGNMENT (RJxRJ) WITH
CONCRETE BLOCKING
(1) - 12" DI LONG BODY SLEEVE, (RJxRJ)
(CONNECTION S)
CONNECTION TO EXISTING 12" DI
WATER MAIN BY CITY FORCES
(CONNECTION R)
CONNECTION TO EXISTING 12" DI
WATER MAIN BY CITY FORCES
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
3
.
D
W
G
SHOWN
WC04 36 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CONNECTION Q: FINAL CONFIGURATION (565 ZONE)CONNECTIONS R & S: FINAL CONFIGURATION (565 ZONE)
CONNECTIONS R & S: POTENTIAL TESTING CONFIGURATION (565 ZONE)CONNECTION Q: POTENTIAL TESTING CONFIGURATION (565 ZONE)
WA
T
E
R
M
A
I
N
T
E
S
T
I
N
G
A
N
D
F
I
N
A
L
C
O
N
N
E
C
T
I
O
N
CO
N
F
I
G
U
R
A
T
I
O
N
S
0
4
NE
1
2
T
H
S
T
-
H
A
R
R
I
N
G
T
O
N
P
L
T
O
J
E
F
F
E
R
S
O
N
A
V
E
NOTE: THESE POTENTIAL TESTING AND FINAL CONFIGURATIONS ARE PROVIDED AS ONE WAY TO COMPLETE THE NECESSARY TESTING AND PHASING OF THE WORK. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS FOR ALL CONNECTIONS
TO EXISTING AND ADJUST AS NECESSARY TO MEET SITE CONDITIONS. FURTHER, THE CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND APPURTENANCES, WHETHER SHOWN AND/OR CALLED OUT HEREIN OR NOT, AS NECESSARY TO
COMPLETE THE RECONNECTIONS IN A FULLY TESTED AND OPERATIONAL MANNER. DEVIATIONS FROM THESE CONFIGURATIONS MAY EXIST ELSEWHERE WITHIN THE PLANS AND SHALL SUPERSEDE WHAT IS SHOWN WITHIN DWG NOS. WC01-WC14.
NE 12TH STREET
(2) - 12" DI PLUG, WITH TEMPORARY CONCRETE BLOCKING
APPROX. STA 25+67.5A, 1.4' R, PROVIDE:
(1) - 12" x 4" DI TEE (RJxFL) WITH CONCRETE BLOCKING
(1) - 4" GATE VALVE (FLxFL)
(1) - 4" DI VERTICAL 45° BEND (FLxRJ) WITH CONCRETE BLOCKING
(1) - 4" DI VERTICAL 45° BEND (RJxRJ) WITH CONCRETE BLOCKING
(1) - 4" DI PLUG, WITH TEMPORARY CONCRETE BLOCKING
KI
R
K
L
A
N
D
A
V
E
N
E
NE 12TH STREET
APPROX. STA 27+41.6A, 70.4' R, PROVIDE:
INSTALL STRADDLE BLOCK ON EXISTING
WATER MAIN WITH SHACKLE RODS TO
RESTRAIN PROPOSED BEND
APPROX. STA 27+28.8A, 57.0' R, PROVIDE:
(1) - 12" x 10" DI TEE (RJxFL) WITH CONCRETE BLOCKING
(1) - 12" DI PLUG WITH CONCRETE BLOCKING
(1) - 10" GATE VALVE (FLxRJ)
(1) - 10" DI PLUG, WITH 2" THREADED TAP, WITH
TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
NE 12TH STREET
APPROX. STA 25+66.6A, 12.4' L, PROVIDE:
(2) - 8" DI CAP
APPROX. STA 25+67.7A, 19.2' L, PROVIDE:
REPLACE EXIST. 4" FIRE SPRINKLER SERVICE LINE.
CONNECT NEW 4" FIRE SPRINGER SERVICE LINE TO
NEW 12" DI (565 ZONE) AND TO EXIST. PRIVATE FIRE
SPRINKLER SERVICE LINE.
CONNECTION TO EXISTING 4" DI
WATER MAIN BY CITY FORCES
KI
R
K
L
A
N
D
A
V
E
N
E
NE 12TH STREET
APPROX. STA 27+41.5A, 57.0' R, PROVIDE:
(1) - 10" DI 90° BEND (RJxRJ) WITH
CONCRETE BLOCKING
(1) - 10" TRANSITION COUPLING (DI TO CI)
(1) - 10" DI CAP
(CONNECTION L)
CONNECTION TO EXISTING 10" CI
WATER MAIN BY CITY FORCES
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
3
.
D
W
G
SHOWN
WC05 37 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
FINAL CONFIGURATION (565 ZONE)CONNECTION L: FINAL CONFIGURATION (565 ZONE)
CONNECTION L: POTENTIAL TESTING CONFIGURATION (565 ZONE)POTENTIAL TESTING CONFIGURATION (565 ZONE)
WA
T
E
R
M
A
I
N
T
E
S
T
I
N
G
A
N
D
F
I
N
A
L
C
O
N
N
E
C
T
I
O
N
CO
N
F
I
G
U
R
A
T
I
O
N
S
0
5
NE
1
2
T
H
S
T
-
J
E
F
F
E
R
S
O
N
A
V
E
T
O
K
I
R
K
L
A
N
D
A
V
E
NOTE: THESE POTENTIAL TESTING AND FINAL CONFIGURATIONS ARE PROVIDED AS ONE WAY TO COMPLETE THE NECESSARY TESTING AND PHASING OF THE WORK. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS FOR ALL CONNECTIONS
TO EXISTING AND ADJUST AS NECESSARY TO MEET SITE CONDITIONS. FURTHER, THE CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND APPURTENANCES, WHETHER SHOWN AND/OR CALLED OUT HEREIN OR NOT, AS NECESSARY TO
COMPLETE THE RECONNECTIONS IN A FULLY TESTED AND OPERATIONAL MANNER. DEVIATIONS FROM THESE CONFIGURATIONS MAY EXIST ELSEWHERE WITHIN THE PLANS AND SHALL SUPERSEDE WHAT IS SHOWN WITHIN DWG NOS. WC01-WC14.
NE 12TH STREET
NE 12TH STREET
KI
R
K
L
A
N
D
A
V
E
N
E
APPROX. STA 27+28.2A, 38.1' L, PROVIDE:
(1) - 12" x 10" DI TEE (RJxFL) WITH CONCRETE BLOCKING
(1) - 12" DI PLUG WITH CONCRETE BLOCKING
(1) - 10" GATE VALVE (FLxRJ)
(1) - 10" DI PLUG, WITH 2" THREADED TAP, WITH
TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
APPROX. STA 27+20.0A, 55.7' L, PROVIDE:
INSTALL STRADDLE BLOCK ON EXISTING
WATER MAIN WITH SHACKLE RODS TO
RESTRAIN PROPOSED BEND
APPROX. STA 27+75.1A, 1.6' R, PROVIDE:
(1) - 12" x 8" DI TEE (RJxFL) WITH CONCRETE BLOCKING
(1) - 8" GATE VALVE (FLxRJ)
(1) - 8" DI PLUG, WITH TEMPORARY CONCRETE BLOCKING
NE 12TH STREET
NE 12TH STREET
KI
R
K
L
A
N
D
A
V
E
N
E
APPROX. STA 27+19.9A, 38.0' L, PROVIDE:
(1) - 10" DI 90° BEND (RJxRJ) WITH CONCRETE BLOCKING,
ROLLED TO ACHIEVE VERTICAL ALIGNMENT
(1) - 10" DI VERTICAL 22-1/2° BEND (RJxRJ) WITH
CONCRETE BLOCKING
(1) - 10" TRANSITION COUPLING (DI TO CI)
(1) - 10" DI CAP
(CONNECTION K)
CONNECTION TO EXISTING 10" CI
WATER MAIN BY CITY FORCES
CONNECTION TO
EXISTING 8" DI WATER
MAIN BY CITY FORCES
APPROX. STA 27+75.1A, 6.3' L, PROVIDE:
(2) - 8" DI VERTICAL 22-1/2° BEND (RJxRJ)
REPLACE EXIST. 8" SERVICE LINE. CONNECT
NEW 8" SERVICE LINE TO NEW 12" DI (565
ZONE) AND TO EXIST. PRIVATE SERVICE LINE.
(2) - 10" DI CAP
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH STREET
INSERT POLYPIG INSIDE NEW 12" PIPE
ON EAST SIDE OF NEW VERTICAL CROSS
APPROX. STA 29+94.9A, 16.1' L, PROVIDE:
(1) - 12" DI CAP, WITH 2" THREADED TAP,
WITH TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
APPROX. STA 29+57.2A, 1.7' R, PROVIDE:
(1) - 12" DI VERTICAL CROSS (FLxRJ), AND
POLYPIGGING/TESTING ASSEMBLY PER COR STD. PLAN 300.7
(1) - 12" DI BLIND FLANGE, WITH 2" THREADED TAP AND 2"
PLUG (TOP)
(1) - 12" DI BLIND FLANGE, (BOTTOM)
(1) - 12" DI PLUG, WITH 2" THREADED TAP, WITH TEMPORARY
CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
APPROX. STA 29+44.5A, 1.8' R, PROVIDE:
(1) - 12" DI VERTICAL CROSS (FLxRJ), AND
POLYPIGGING/TESTING ASSEMBLY PER COR STD. PLAN 300.7
(1) - 12" DI BLIND FLANGE, WITH 2" THREADED TAP (TOP)
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
(1) - 12" DI BLIND FLANGE, (BOTTOM)
(1) - 12" DI PLUG, WITH TEMPORARY CONCRETE BLOCKING
APPROX. STA 29+00.2A, 1.7' R, PROVIDE:
(1) - 12" DI TEE (FLxFL) WITH CONCRETE BLOCKING
(1) - 12" DI ADAPTER (RJxFL)
(2) - 12" GATE VALVE (FLxRJ)
(1) - 12" DI 90° BEND (RJxRJ) WITH CONCRETE BLOCKING
(1) - 12" DI PLUG, WITH 2" THREADED TAP, WITH
TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
(CONNECTION Z)
CONNECTION TO
EXISTING 16" DI WATER
MAIN BY CITY FORCES
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH STREET
APPROX. STA 29+94.9A, 17.9' L, PROVIDE:
(2) - 12" DI 45° BEND ROLLED TO ACHIEVE VERTICAL
AND HORIZONTAL ALIGNMENT (RJxRJ) WITH
CONCRETE BLOCKING
(1) - 12" DI LONG BODY SLEEVE, (RJxRJ)
(1) - 12" DI CAP
APPROX. STA 29+04.4A, 6.4' R, PROVIDE:
(1) - 12" DI VERTICAL 22-1/2° BEND (RJxRJ)
WITH CONCRETE BLOCKING
(1) - 12" DI 22-1/2° VERTICAL BEND (FLxRJ)
WITH CONCRETE BLOCKING
(1) - 12" DI 45° BEND (FLxRJ) WITH
CONCRETE BLOCKING
(1) - 12" DI LONG BODY SLEEVE, (RJxRJ)
(1) - 12" DI CAP
APPROX. STA 29+44.2A, 1.7' R, PROVIDE:
(2) - 12" DI LONG BODY SLEEVE, (RJxRJ)
(CONNECTION T)
CONNECTION TO EXISTING 12" DI
WATER MAIN BY CITY FORCES
(CONNECTION Z)
CONNECTION TO
EXISTING 16" DI WATER
MAIN BY CITY FORCES
(CONNECTION U)
CONNECTION TO EXISTING 12" DI
WATER MAIN BY CITY FORCES
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
3
.
D
W
G
SHOWN
WC06 38 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CONNECTION K: FINAL CONFIGURATION (565 ZONE)
CONNECTION K: POTENTIAL TESTING CONFIGURATION (565 ZONE)
WA
T
E
R
M
A
I
N
T
E
S
T
I
N
G
A
N
D
F
I
N
A
L
C
O
N
N
E
C
T
I
O
N
CO
N
F
I
G
U
R
A
T
I
O
N
S
0
6
NE
1
2
T
H
S
T
-
K
I
R
K
L
A
N
D
A
V
E
T
O
S
U
N
S
E
T
B
L
V
D
CONNECTIONS T & U: FINAL CONFIGURATION (565 ZONE)
CONNECTIONS T & U: POTENTIAL TESTING CONFIGURATION (565 ZONE)
NOTE: THESE POTENTIAL TESTING AND FINAL CONFIGURATIONS ARE PROVIDED AS ONE WAY TO COMPLETE THE NECESSARY TESTING AND PHASING OF THE WORK. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS FOR ALL CONNECTIONS
TO EXISTING AND ADJUST AS NECESSARY TO MEET SITE CONDITIONS. FURTHER, THE CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND APPURTENANCES, WHETHER SHOWN AND/OR CALLED OUT HEREIN OR NOT, AS NECESSARY TO
COMPLETE THE RECONNECTIONS IN A FULLY TESTED AND OPERATIONAL MANNER. DEVIATIONS FROM THESE CONFIGURATIONS MAY EXIST ELSEWHERE WITHIN THE PLANS AND SHALL SUPERSEDE WHAT IS SHOWN WITHIN DWG NOS. WC01-WC14.
(2) - 16" DI LONG BODY SLEEVE, (RJxRJ)
APPROX. STA 30+25.8A, 62.2' R, PROVIDE:
(1) - 10" DI CAP, WITH 2" THREADED TAP,
WITH TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
APPROX. STA 30+23.6A, 77.9' R, PROVIDE:
INSTALL STRADDLE BLOCK ON EXISTING
WATER MAIN WITH SHACKLE RODS TO
RESTRAIN PROPOSED BEND
NE
S
U
N
S
E
T
B
L
V
D
APPROX. STA 30+31.9A, 66.9' R, PROVIDE:
(1) - 10" DI 90° BEND (RJxRJ) WITH CONCRETE BLOCKING
(1) - 10" TRANSITION COUPLING (DI TO CI)
(1) - 10" DI CAP
NE
S
U
N
S
E
T
B
L
V
D
(CONNECTION M)
CONNECTION TO EXISTING 10" CI
WATER MAIN BY CITY FORCES
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH STREET NE 12TH STREET
APPROX. STA 30+39.8A, 21.4' L, PROVIDE:
(1) - 16" DI CAP, WITH 2" THREADED TAP,
WITH TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
APPROX. STA 30+35.3A, 5.3' L, PROVIDE:
(1) - 16" DI CROSS (FLxRJ)
(2) - 16" BUTTERFLY VALVE (FLxRJ)
(2) - 16" DI PLUG, WITH TEMPORARY
CONCRETE BLOCKING
(2) - 16" DI LONG BODY SLEEVE, (RJxRJ)
APPROX. STA 30+31.3A, 8.4' R, PROVIDE:
(1) - 16" DI CAP, WITH 2" THREADED TAP,
WITH TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
NE
S
U
N
S
E
T
B
L
V
D
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH STREET NE 12TH STREET
APPROX. STA 30+35.3A, 13.2' L, PROVIDE:
(1) - 16" DI 22-1/2° BEND (RJxRJ) WITH CONCRETE BLOCKING
(1) - 16" DI 11-1/4° BEND (RJxRJ) WITH CONCRETE BLOCKING
(1) - 16" DI LONG BODY SLEEVE, (RJxRJ)
APPROX. STA 30+35.3A, 0.0' L, PROVIDE:
(1) - 16" DI 11-1/4° BEND (RJxRJ) WITH CONCRETE BLOCKING
(1) - 16" DI 22-1/2° BEND (RJxRJ) WITH CONCRETE BLOCKING
(1) - 16" DI LONG BODY SLEEVE, (RJxRJ)
NE
S
U
N
S
E
T
B
L
V
D
(CONNECTION Z)
CONNECTION TO
EXISTING 16" DI WATER
MAIN BY CITY FORCES
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
3
.
D
W
G
SHOWN
WC07 39 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CONNECTION M: FINAL CONFIGURATION (435 ZONE)
CONNECTION M: POTENTIAL TESTING CONFIGURATION (435 ZONE)
WA
T
E
R
M
A
I
N
T
E
S
T
I
N
G
A
N
D
F
I
N
A
L
C
O
N
N
E
C
T
I
O
N
CO
N
F
I
G
U
R
A
T
I
O
N
S
0
7
NE
1
2
T
H
S
T
-
S
U
N
S
E
T
B
L
V
D
I
N
T
E
R
S
E
C
T
I
O
N
CONNECTION Z: FINAL CONFIGURATION (435 ZONE)
CONNECTION Z: POTENTIAL TESTING CONFIGURATION (435 ZONE)
NOTE: THESE POTENTIAL TESTING AND FINAL CONFIGURATIONS ARE PROVIDED AS ONE WAY TO COMPLETE THE NECESSARY TESTING AND PHASING OF THE WORK. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS FOR ALL CONNECTIONS
TO EXISTING AND ADJUST AS NECESSARY TO MEET SITE CONDITIONS. FURTHER, THE CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND APPURTENANCES, WHETHER SHOWN AND/OR CALLED OUT HEREIN OR NOT, AS NECESSARY TO
COMPLETE THE RECONNECTIONS IN A FULLY TESTED AND OPERATIONAL MANNER. DEVIATIONS FROM THESE CONFIGURATIONS MAY EXIST ELSEWHERE WITHIN THE PLANS AND SHALL SUPERSEDE WHAT IS SHOWN WITHIN DWG NOS. WC01-WC14.
NE 12TH STREET
APPROX. STA 31+38.5A, 2.4' R, PROVIDE:
(1) - 12" x 6" DI TEE (RJxFL) WITH
CONCRETE BLOCKING
(1) - 6" GATE VALVE (FLxRJ)
(1) - 6" DI PLUG, WITH TEMPORARY
CONCRETE BLOCKING
APPROX. STA 31+67.7A, 2.3' R, PROVIDE:
(1) - 12" x 6" DI TEE (RJxFL) WITH
CONCRETE BLOCKING
(1) - 6" GATE VALVE (FLxRJ)
(1) - 6" DI PLUG, WITH TEMPORARY
CONCRETE BLOCKING
NE 12TH STREET
APPROX. STA 31+38.5A, 5.9' L, PROVIDE:
(2) - 6" DI VERTICAL 22-1/2° BEND (RJxRJ)
(1) - 6" DI LONG BODY SLEEVE, (RJxRJ)
(2) - 10" DI CAP
APPROX. STA 31+67.4A, 16.6' L, PROVIDE:
(1) - 6" DI LONG BODY SLEEVE, (RJxRJ)
(2) - 10" DI CAP
CONNECTION TO EXISTING 6" DI
HYDRANT BY CITY FORCES
CONNECTION TO
EXISTING 6" DI WATER
BY CITY FORCES
LY
N
N
W
O
O
D
AV
E
N
E
NE 12TH STREET
APPROX. STA 33+24.3A, 50.9' R, PROVIDE:
(1) - 12" x 6" DI TEE (RJxFL) WITH
CONCRETE BLOCKING
(1) - 6" GATE VALVE (FLxRJ)
(1) - 6" DI PLUG, WITH TEMPORARY
CONCRETE BLOCKING
APPROX. STA 33+33.6A, 76.3' R, PROVIDE:
INSTALL STRADDLE BLOCK ON EXISTING
WATER MAIN WITH SHACKLE RODS TO
RESTRAIN PROPOSED BEND
APPROX. STA 33+24.3A, 60.1' R, PROVIDE:
(1) - 12" x 8" DI TEE (RJxRJ) WITH CONCRETE BLOCKING
(1) - 12" DI PLUG WITH CONCRETE BLOCKING
(1) - 8" DI PLUG, WITH TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
LY
N
N
W
O
O
D
AV
E
N
E
NE 12TH STREET
APPROX. STA 33+33.5A, 60.1' R, PROVIDE:
(1) - 8" DI 90° BEND (RJxRJ) WITH
CONCRETE BLOCKING
(1) - 8" GATE VALVE (RJxRJ)
(1) - 8" TRANSITION COUPLING (DI TO CI)
(1) - 8" DI CAP
APPROX. STA 33+17.8A, 50.9' R, PROVIDE:
(2) - 6" DI 45° BEND (RJxRJ) WITH CONCRETE BLOCKING
(1) - 6" DI LONG BODY SLEEVE, (RJxRJ)
(1) - 6" DI CAP
(CONNECTION E)
CONNECTION TO EXISTING 8" CI
WATER MAIN BY CITY FORCES
CONNECTION TO
EXISTING 6" DI WATER
MAIN BY CITY FORCES
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
3
.
D
W
G
SHOWN
WC08 40 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
FINAL CONFIGURATION (565 ZONE)
POTENTIAL TESTING CONFIGURATION (565 ZONE)
CONNECTION E: FINAL CONFIGURATION (565 ZONE)
CONNECTION E: POTENTIAL TESTING CONFIGURATION (565 ZONE)
WA
T
E
R
M
A
I
N
T
E
S
T
I
N
G
A
N
D
F
I
N
A
L
C
O
N
N
E
C
T
I
O
N
CO
N
F
I
G
U
R
A
T
I
O
N
S
0
8
NE
1
2
T
H
S
T
-
S
U
N
S
E
T
B
L
V
D
T
O
L
Y
N
N
W
O
O
D
A
V
E
NOTE: THESE POTENTIAL TESTING AND FINAL CONFIGURATIONS ARE PROVIDED AS ONE WAY TO COMPLETE THE NECESSARY TESTING AND PHASING OF THE WORK. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS FOR ALL CONNECTIONS
TO EXISTING AND ADJUST AS NECESSARY TO MEET SITE CONDITIONS. FURTHER, THE CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND APPURTENANCES, WHETHER SHOWN AND/OR CALLED OUT HEREIN OR NOT, AS NECESSARY TO
COMPLETE THE RECONNECTIONS IN A FULLY TESTED AND OPERATIONAL MANNER. DEVIATIONS FROM THESE CONFIGURATIONS MAY EXIST ELSEWHERE WITHIN THE PLANS AND SHALL SUPERSEDE WHAT IS SHOWN WITHIN DWG NOS. WC01-WC14.
MO
N
R
O
E
A
V
E
N
E
NE 12TH STREET
APPROX. STA 35+53.6A, 32.9' R, PROVIDE:
(1) - 10" DI TEE (RJxRJ) WITH CONCRETE BLOCKING
(1) - 10" DI PLUG WITH CONCRETE BLOCKING
(1) - 10" DI PLUG, WITH 2" THREADED TAP, WITH TEMPORARY
CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
APPROX. STA 35+59.7A, 46.7' R, PROVIDE:
INSTALL STRADDLE BLOCK ON EXISTING
WATER MAIN WITH SHACKLE RODS TO
RESTRAIN PROPOSED SLEEVE
MO
N
R
O
E
A
V
E
N
E
NE 12TH STREET
APPROX. STA 35+59.1A, 32.8' R, PROVIDE:
(1) - 10" DI 90° BEND (RJxRJ) WITH CONCRETE BLOCKING
(1) - 10" DI LONG BODY SLEEVE, (RJxRJ)
(1) - 10" DI CAP
(CONNECTION N)
CONNECTION TO EXISTING 10" DI
WATER MAIN BY CITY FORCES
LOCATE AND VERIFY EXISTING 1" SERVICE
LINE. INSTALL 1" NEW WATER SERVICE LINE.
CONNECT NEW 1" WATER SERVICE LINE TO
EXISTING 1" SERVICE LINE WITH 3-PART UNION.
MO
N
R
O
E
A
V
E
N
E
NE 12TH STREET
APPROX. STA 37+02.1A, 42.6' L, PROVIDE:
INSTALL STRADDLE BLOCK ON EXISTING
WATER MAIN WITH SHACKLE RODS TO
RESTRAIN PROPOSED SLEEVE
APPROX. STA 37+07.3A, 25.8' L, PROVIDE:
(1) - 8" DI TEE (RJxRJ) WITH CONCRETE BLOCKING, ROLLED TO
ACHIEVE VERTICAL ALIGNMENT
(1) - 8" DI PLUG WITH CONCRETE BLOCKING
(1) - 8" DI PLUG, WITH 2" THREADED TAP, WITH TEMPORARY
CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
MO
N
R
O
E
A
V
E
N
E
NE 12TH STREET
APPROX. STA 37+02.4A, 25.7' L, PROVIDE:
(1) - 8" DI 90° BEND (RJxRJ) WITH CONCRETE BLOCKING,
ROLLED TO ACHIEVE VERTICAL ALIGNMENT
(1) - 8" GATE VALVE (RJxRJ)
(1) - 8" DI LONG BODY SLEEVE, (RJxRJ)
(1) - 8" DI CAP
(CONNECTION F)
CONNECTION TO EXISTING 8" DI
WATER MAIN BY CITY FORCES
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
3
.
D
W
G
SHOWN
WC09 41 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CONNECTION N: FINAL CONFIGURATION (565 ZONE)
CONNECTION N: POTENTIAL TESTING CONFIGURATION (565 ZONE)
CONNECTION F: FINAL CONFIGURATION (565 ZONE)
CONNECTION F: POTENTIAL TESTING CONFIGURATION (565 ZONE)
WA
T
E
R
M
A
I
N
T
E
S
T
I
N
G
A
N
D
F
I
N
A
L
C
O
N
N
E
C
T
I
O
N
CO
N
F
I
G
U
R
A
T
I
O
N
S
0
9
NE
1
2
T
H
S
T
-
L
Y
N
N
W
O
O
D
A
V
E
T
O
M
O
N
R
O
E
A
V
E
NOTE: THESE POTENTIAL TESTING AND FINAL CONFIGURATIONS ARE PROVIDED AS ONE WAY TO COMPLETE THE NECESSARY TESTING AND PHASING OF THE WORK. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS FOR ALL CONNECTIONS
TO EXISTING AND ADJUST AS NECESSARY TO MEET SITE CONDITIONS. FURTHER, THE CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND APPURTENANCES, WHETHER SHOWN AND/OR CALLED OUT HEREIN OR NOT, AS NECESSARY TO
COMPLETE THE RECONNECTIONS IN A FULLY TESTED AND OPERATIONAL MANNER. DEVIATIONS FROM THESE CONFIGURATIONS MAY EXIST ELSEWHERE WITHIN THE PLANS AND SHALL SUPERSEDE WHAT IS SHOWN WITHIN DWG NOS. WC01-WC14.
NE 12TH STREET
APPROX. STA 39+60.9A, 55.7' L, PROVIDE:
INSTALL STRADDLE BLOCK ON EXISTING
WATER MAIN WITH SHACKLE RODS TO
RESTRAIN PROPOSED REDUCER
APPROX. STA 39+57.0A, 36.6' L, PROVIDE:
(1) - 12" DI CAP, WITH 2" THREADED TAP,
WITH TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
NE 12TH STREET
APPROX. STA 39+57.0A, 38.3' L, PROVIDE:
(2) - 12" DI 45° BEND (RJxRJ) WITH CONCRETE BLOCKING,
ROLLED TO ACHIEVE VERTICAL ALIGNMENT
(1) - 12" x 16" DI REDUCER (RJxRJ)
(1) - 16" TRANSITION COUPLING (DI TO CI)
(1) - 16" DI CAP
(CONNECTION AA)
CONNECTION TO EXISTING 16" CI
WATER MAIN BY CITY FORCES
NE 12TH STREET
INSERT POLYPIG INSIDE NEW 12" PIPE
ON EAST SIDE OF NEW VERTICAL CROSS
APPROX. STA 39+73.4A, 6.3' L, PROVIDE:
(1) - 16" DI VERTICAL CROSS (FLxRJ), AND POLYPIGGING/TESTING
ASSEMBLY PER COR STD. PLAN 300.7
(1) - 16" DI BLIND FLANGE, WITH 2" THREADED TAP AND 2" PLUG (TOP)
(1) - 16" DI BLIND FLANGE, (BOTTOM)
(1) - 16" DI PLUG, WITH 2" THREADED TAP, WITH TEMPORARY
CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
NE 12TH STREET
APPROX. STA 39+63.6A, 6.1' L, PROVIDE:
(1) - 16" DI TEE (FLxFL) WITH CONCRETE BLOCKING
(3) - 16" BUTTERFLY VALVE (FLxRJ)
(2) - 16" TRANSITION COUPLING (DI TO CI)
(CONNECTION AB)
CONNECTION TO EXISTING 16" DI
WATER MAIN BY CITY FORCES
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
3
.
D
W
G
SHOWN
WC10 42 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CONNECTION AA: FINAL CONFIGURATION (565 ZONE)
CONNECTION AA: POTENTIAL TESTING CONFIGURATION (565 ZONE)
CONNECTION AB: FINAL CONFIGURATION (435 ZONE)
CONNECTION AB: POTENTIAL TESTING CONFIGURATION (435 ZONE)
WA
T
E
R
M
A
I
N
T
E
S
T
I
N
G
A
N
D
F
I
N
A
L
C
O
N
N
E
C
T
I
O
N
CO
N
F
I
G
U
R
A
T
I
O
N
S
1
0
NE
1
2
T
H
S
T
-
M
O
N
R
O
E
A
V
E
T
O
O
L
Y
M
P
I
A
A
V
E
NOTE: THESE POTENTIAL TESTING AND FINAL CONFIGURATIONS ARE PROVIDED AS ONE WAY TO COMPLETE THE NECESSARY TESTING AND PHASING OF THE WORK. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS FOR ALL CONNECTIONS
TO EXISTING AND ADJUST AS NECESSARY TO MEET SITE CONDITIONS. FURTHER, THE CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND APPURTENANCES, WHETHER SHOWN AND/OR CALLED OUT HEREIN OR NOT, AS NECESSARY TO
COMPLETE THE RECONNECTIONS IN A FULLY TESTED AND OPERATIONAL MANNER. DEVIATIONS FROM THESE CONFIGURATIONS MAY EXIST ELSEWHERE WITHIN THE PLANS AND SHALL SUPERSEDE WHAT IS SHOWN WITHIN DWG NOS. WC01-WC14.
NE 12TH STREET
APPROX. STA 40+67.8A, 3.6' L, PROVIDE:
(1) - 12" CI CAP WITH CONCRETE BLOCKING
APPROX. STA 41+75.7A, 58.4' L, PROVIDE:
(1) - 16" DI VERTICAL CROSS (FLxFL), AND POLYPIGGING/TESTING
ASSEMBLY PER COR STD. PLAN 300.7
(1) - 16" DI BLIND FLANGE, WITH 2" THREADED TAP (TOP)
(1) - 2" PERMANENT BLOW-OFF ASSEMBLY, PER COR STD. PLAN 340.1
(1) - 16" DI BLIND FLANGE, (BOTTOM)
(1) - 16" DI ADAPTER (RJxFL)
(1) - 16" BUTTERFLY VALVE (FLxRJ)
(1) - 16" DI PLUG WITH CONCRETE BLOCKING
APPROX. STA 40+67.4A, 27.0' L, PROVIDE:
(1) - 12" DI CAP, WITH 2" THREADED TAP,
WITH TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
NE 12TH STREET
APPROX. STA 40+67.4A, 28.1' L, PROVIDE:
(1) - 12" DI LONG BODY SLEEVE, (RJxRJ)
(1) - 12" TRANSITION COUPLING (DI TO CI)
(CONNECTION W)
CONNECTION TO EXISTING 12" CI
WATER MAIN BY CITY FORCES
OL
Y
M
P
I
A
A
V
E
N
E
NE 12TH STREET
APPROX. STA 42+00.1A, 34.8' R, PROVIDE:
(1) - 8" DI TEE (RJxFL) WITH CONCRETE BLOCKING
(1) - 8" DI PLUG WITH CONCRETE BLOCKING
(1) - 8" GATE VALVE (FLxRJ)
(1) - 8" DI PLUG, WITH 2" THREADED TAP, WITH TEMPORARY
CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
APPROX. STA 42+17.6A, 48.1' R, PROVIDE:
INSTALL STRADDLE BLOCK ON EXISTING
WATER MAIN WITH SHACKLE RODS TO
RESTRAIN PROPOSED BEND
OL
Y
M
P
I
A
A
V
E
N
E
NE 12TH STREET
APPROX. STA 42+17.3A, 34.5' R, PROVIDE:
(1) - 8" DI 90° BEND (RJxRJ) WITH CONCRETE BLOCKING
(1) - 8" DI LONG BODY SLEEVE, (RJxRJ)
(1) - 8" DI CAP
(CONNECTION G)
CONNECTION TO EXISTING 8" DI
WATER MAIN BY CITY FORCES
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
3
.
D
W
G
SHOWN
WC11 43 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CONNECTION W: FINAL CONFIGURATION (435 ZONE)
CONNECTION W: POTENTIAL TESTING CONFIGURATION (435 ZONE)
CONNECTION G: FINAL CONFIGURATION (565 ZONE)
CONNECTION G: POTENTIAL TESTING CONFIGURATION (565 ZONE)
WA
T
E
R
M
A
I
N
T
E
S
T
I
N
G
A
N
D
F
I
N
A
L
C
O
N
N
E
C
T
I
O
N
CO
N
F
I
G
U
R
A
T
I
O
N
S
1
1
NE
1
2
T
H
S
T
-
M
O
N
R
O
E
A
V
E
T
O
O
L
Y
M
P
I
A
A
V
E
NOTE: THESE POTENTIAL TESTING AND FINAL CONFIGURATIONS ARE PROVIDED AS ONE WAY TO COMPLETE THE NECESSARY TESTING AND PHASING OF THE WORK. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS FOR ALL CONNECTIONS
TO EXISTING AND ADJUST AS NECESSARY TO MEET SITE CONDITIONS. FURTHER, THE CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND APPURTENANCES, WHETHER SHOWN AND/OR CALLED OUT HEREIN OR NOT, AS NECESSARY TO
COMPLETE THE RECONNECTIONS IN A FULLY TESTED AND OPERATIONAL MANNER. DEVIATIONS FROM THESE CONFIGURATIONS MAY EXIST ELSEWHERE WITHIN THE PLANS AND SHALL SUPERSEDE WHAT IS SHOWN WITHIN DWG NOS. WC01-WC14.
PI
E
R
C
E
P
L
N
E
NE 12TH STREET
INSERT POLYPIG INSIDE NEW 12" PIPE
ON EAST SIDE OF NEW VERTICAL CROSS
APPROX. STA 43+94.7A, 3.7' R, PROVIDE:
(1) - 12" DI VERTICAL CROSS (FLxRJ), AND POLYPIGGING/TESTING
ASSEMBLY PER COR STD. PLAN 300.7
(1) - 12" DI BLIND FLANGE, WITH 2" THREADED TAP AND 2" PLUG (TOP)
(1) - 12" DI BLIND FLANGE, (BOTTOM)
(1) - 12" DI PLUG, WITH 2" THREADED TAP, WITH TEMPORARY
CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
APPROX. STA 43+76.7A, 3.6' R, PROVIDE:
(1) - 12" DI VERTICAL CROSS (FLxRJ), AND
POLYPIGGING/TESTING ASSEMBLY PER COR STD. PLAN 300.7
(1) - 12" DI BLIND FLANGE, WITH 2" THREADED TAP (TOP)
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
(1) - 12" DI BLIND FLANGE, (BOTTOM)
(1) - 12" DI PLUG, WITH TEMPORARY CONCRETE BLOCKING
PI
E
R
C
E
A
V
E
N
E
NE 12TH STREET
APPROX. STA 45+15.6A, 4.1' R, PROVIDE:
(1) - 12" x 8" DI TEE (FLxFL) WITH CONCRETE BLOCKING
(1) - 12" DI ADAPTER (RJxFL)
(1) - 12" GATE VALVE (FLxRJ)
(1) - 8" GATE VALVE (FLxRJ)
(1) - 8" DI PLUG, WITH TEMPORARY CONCRETE BLOCKING
PI
E
R
C
E
P
L
N
E
NE 12TH STREET
APPROX. STA 43+89.9A, 3.6' R, PROVIDE:
REMOVE EXISTING 12" PLUG AND
CONNECT TO EXISTING 12" GATE VALVE
(1) - 12" DI LONG BODY SLEEVE, (RJxRJ)
CONNECTION TO EXISTING 12"x8"
DI CROSS BY CITY FORCES
GATE VALVE REMOVAL AND BLIND
FLANGE INSTALLATION BY CITY
FORCES. CONCRETE BLOCKING
INSTALLATION BY CONTRACTOR.
APPROX. STA 43+81.5A, 3.6' R, PROVIDE:
REMOVE EXISTING 12" PLUG AND
CONNECT TO EXISTING 12" GATE VALVE
(1) - 12" DI LONG BODY SLEEVE, (RJxRJ)
PI
E
R
C
E
A
V
E
N
E
NE 12TH STREET
APPROX. STA 45+15.8A, 16.5' R, PROVIDE:
(1) - 8" DI LONG BODY SLEEVE, (RJxRJ)
(CONNECTION H)
CONNECTION TO EXISTING 8" DI
WATER MAIN BY CITY FORCES
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
3
.
D
W
G
SHOWN
WC12 44 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
FINAL CONFIGURATION (565 ZONE)CONNECTION H: FINAL CONFIGURATION (565 ZONE)
CONNECTION H: POTENTIAL TESTING CONFIGURATION (565 ZONE)POTENTIAL TESTING CONFIGURATION (565 ZONE)
WA
T
E
R
M
A
I
N
T
E
S
T
I
N
G
A
N
D
F
I
N
A
L
C
O
N
N
E
C
T
I
O
N
CO
N
F
I
G
U
R
A
T
I
O
N
S
1
2
NE
1
2
T
H
S
T
-
P
I
E
R
C
E
P
L
T
O
P
I
E
R
C
E
A
V
E
NOTE: THESE POTENTIAL TESTING AND FINAL CONFIGURATIONS ARE PROVIDED AS ONE WAY TO COMPLETE THE NECESSARY TESTING AND PHASING OF THE WORK. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS FOR ALL CONNECTIONS
TO EXISTING AND ADJUST AS NECESSARY TO MEET SITE CONDITIONS. FURTHER, THE CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND APPURTENANCES, WHETHER SHOWN AND/OR CALLED OUT HEREIN OR NOT, AS NECESSARY TO
COMPLETE THE RECONNECTIONS IN A FULLY TESTED AND OPERATIONAL MANNER. DEVIATIONS FROM THESE CONFIGURATIONS MAY EXIST ELSEWHERE WITHIN THE PLANS AND SHALL SUPERSEDE WHAT IS SHOWN WITHIN DWG NOS. WC01-WC14.
NE 12TH STREET
QU
E
E
N
A
V
E
N
E
APPROX. STA 46+40.4A, 4.3' L, PROVIDE:
(1) - 12" DI 22-1/2° BEND (RJxRJ) WITH CONCRETE BLOCKING
(1) - 12" DI VERTICAL CROSS (FLxRJ), AND POLYPIGGING/TESTING
ASSEMBLY PER COR STD. PLAN 300.7
(1) - 12" DI BLIND FLANGE, WITH 2" THREADED TAP (TOP)
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
(1) - 12" DI BLIND FLANGE, (BOTTOM)
(1) - 12" DI PLUG, WITH TEMPORARY CONCRETE BLOCKING
NE 12TH STREET
QU
E
E
N
A
V
E
N
E
APPROX. STA 46+50.4A, 4.3' L, PROVIDE:
(1) - 12" DI LONG BODY SLEEVE, RJxRJ
(CONNECTION V)
CONNECTION TO EXISTING 12" DI
WATER MAIN BY CITY FORCES
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
3
.
D
W
G
SHOWN
WC13 45 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CONNECTION V: FINAL CONFIGURATION (565 ZONE)
CONNECTION V: POTENTIAL TESTING CONFIGURATION (565 ZONE)
WA
T
E
R
M
A
I
N
T
E
S
T
I
N
G
A
N
D
F
I
N
A
L
C
O
N
N
E
C
T
I
O
N
CO
N
F
I
G
U
R
A
T
I
O
N
S
1
3
NE
1
2
T
H
S
T
-
P
I
E
R
C
E
A
V
E
T
O
Q
U
E
E
N
A
V
E
NOTE: THESE POTENTIAL TESTING AND FINAL CONFIGURATIONS ARE PROVIDED AS ONE WAY TO COMPLETE THE NECESSARY TESTING AND PHASING OF THE WORK. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS FOR ALL CONNECTIONS
TO EXISTING AND ADJUST AS NECESSARY TO MEET SITE CONDITIONS. FURTHER, THE CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND APPURTENANCES, WHETHER SHOWN AND/OR CALLED OUT HEREIN OR NOT, AS NECESSARY TO
COMPLETE THE RECONNECTIONS IN A FULLY TESTED AND OPERATIONAL MANNER. DEVIATIONS FROM THESE CONFIGURATIONS MAY EXIST ELSEWHERE WITHIN THE PLANS AND SHALL SUPERSEDE WHAT IS SHOWN WITHIN DWG NOS. WC01-WC14.
MONROE AVE. NE
APPROX. STA 14+92.4B, 22.8' L, PROVIDE:
(1) - 8" DI CAP, WITH 2" THREADED TAP, WITH
TEMPORARY CONCRETE BLOCKING
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
INSERT POLYPIG INSIDE NEW 12" PIPE
ON NORTH SIDE OF NEW GATE VALVE
MONROE AVE. NE
APPROX. STA 17+20.3B, 7.5' R, PROVIDE:
(1) - 8" DI VERTICAL CROSS (RJxFL), AND POLYPIGGING/TESTING
ASSEMBLY PER COR STD. PLAN 300.7
(1) - 8" DI BLIND FLANGE, WITH 2" THREADED TAP (TOP)
(1) - 2" TEMPORARY BLOW-OFF ASSEMBLY
(1) - 8" DI BLIND FLANGE, (BOTTOM)
(1) - 8" DI PLUG, WITH TEMPORARY CONCRETE BLOCKING
MONROE AVE. NE
APPROX. STA 14+91.0B, 22.8' L, PROVIDE:
(1) - 8" DI LONG BODY SLEEVE, (RJxRJ)
(CONNECTION I)
CONNECTION TO EXISTING 8" DI
WATER MAIN BY CITY FORCES
MONROE AVE. NE
APPROX. STA 17+25.4B, 7.5' R, PROVIDE:
(1) - 8" x 10" DI REDUCER (RJxRJ)
(1) - 10" DI LONG BODY SLEEVE, (RJxRJ)
(1) - 8" DI CAP
(CONNECTION J)
CONNECTION TO EXISTING 10" DI
WATER MAIN BY CITY FORCES
CJ
B
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
W
0
3
.
D
W
G
SHOWN
WC14 46 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CONNECTION I: FINAL CONFIGURATION (435 ZONE)CONNECTION J: FINAL CONFIGURATION (565 ZONE)
CONNECTION J: POTENTIAL TESTING CONFIGURATION (565 ZONE)CONNECTION I: POTENTIAL TESTING CONFIGURATION (435 ZONE)
WA
T
E
R
M
A
I
N
T
E
S
T
I
N
G
A
N
D
F
I
N
A
L
C
O
N
N
E
C
T
I
O
N
CO
N
F
I
G
U
R
A
T
I
O
N
S
1
4
MO
N
R
O
E
A
V
E
N
E
-
1
2
T
H
S
T
T
O
S
U
N
S
E
T
B
L
V
D
NOTE: THESE POTENTIAL TESTING AND FINAL CONFIGURATIONS ARE PROVIDED AS ONE WAY TO COMPLETE THE NECESSARY TESTING AND PHASING OF THE WORK. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS FOR ALL CONNECTIONS
TO EXISTING AND ADJUST AS NECESSARY TO MEET SITE CONDITIONS. FURTHER, THE CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND APPURTENANCES, WHETHER SHOWN AND/OR CALLED OUT HEREIN OR NOT, AS NECESSARY TO
COMPLETE THE RECONNECTIONS IN A FULLY TESTED AND OPERATIONAL MANNER. DEVIATIONS FROM THESE CONFIGURATIONS MAY EXIST ELSEWHERE WITHIN THE PLANS AND SHALL SUPERSEDE WHAT IS SHOWN WITHIN DWG NOS. WC01-WC14.
2601 & 2603 NE 12TH ST
TPN: 7227801335
1" LATERAL 3/4" METER
ACCNT #003066
NA
TPN: 0923059102
NO METER
2527 NE 12TH ST
TPN: 0923059062
1" LATERAL 3/4"
METER ACCNT
#140025
1140 EDMONDS AVE NE
TPN: 0923059061
METER ON EDMONDS
1190 EDMONDS PL NE
TPN: 2270000020
1194 EDMONDS PL NE
TPN: 2270000010
2430 NE 12TH ST
TPN: 2309200010
JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
ED
M
O
N
D
S
A
V
E
N
E
NE 12TH STREET
12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)
12
'
'
D
I
W
(
5
6
5
)
\
\
\
\
\
\
PH1
PH1A
PH2
PH2A
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\PH G1 PH P1
\\\\\\\\\\\\\\\\\\\\\\
\
\
\
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXXXXXXXXXX X X X X X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
PPH2
PPH3
GPH4
GPH5
GPH6
GPH7
GPH8
PPH9
PPH11
CB #3
WITH RECTANGULAR
FRAME & VANED GRATE
CB #2
WITH RECTANGULAR
FRAME & VANED GRATE
32
CB #1
WITH RECTANGULAR
FRAME & VANED GRATE
1
00
A
10
00
A
11
00
A
12
00
A
13
00
A
14
CB #2 TO EX. SDMH PROFILE VIEW
320'
330'
340'
350'
360'
320'
330'
340'
350'
360'
-55 LF 0 LF 10 LF
CB #3 TO EX. SDMH PROFILE VIEW
325'
330'
340'
350'
360'
325'
330'
340'
350'
360'
-50 LF 0 LF 10 LF
CB #1 TO EX. SDMH PROFILE VIEW
300'
310'
320'
330'
340'
300'
310'
320'
330'
340'
-8 LF 0 LF 50 LF
PR
O
P
.
W
A
T
E
R
5
6
5
1
2
"
D
I
PR
O
P
.
W
A
T
E
R
5
6
5
1
2
"
D
I
APPROX. 43'
OF 8" DIP @ 1.03%
APPROX. 42'
OF 8" DIP @ 7.44%CB #2 - TYPE I
STA 11+95.1A, 18.8 L
RIM = 342.51'
8" DIP (OUT-SW) IE = 339.50'
CB #1 - TYPE IL
STA 9+79.7A, 30.9 L
RIM = 326.75'
8" DIP (OUT-NE) IE = 324.06'
CB #3 - TYPE I
STA 14+05.1A, 19.0 L
RIM = 349.27'
8" DIP (OUT-SW) IE = 346.50'
APPROX. 55'
OF 8" DIP @ 15.86%
321
8" DIP (IN NE) IE=338.00' (PROP.)
8" DIP (IN NE) IE=336.50' (PROP.)
8" DIP (IN NE) IE=323.23' (PROP.)
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS, TYP.
10+17A 11+58A 13+68A
PR
O
P
.
3
"
F
I
B
E
R
CR
O
S
S
I
N
G
PR
O
P
.
3
"
F
I
B
E
R
CR
O
S
S
I
N
G
PR
O
P
.
3
"
F
I
B
E
R
CR
O
S
S
I
N
G
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS, TYP.
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS, TYP.
EXISTING GAS LINE TO BE
RELOCATED BY PSE
GENERAL CONSTRUCTION NOTES
CONSTRUCTION NOTES
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
C01 C02 C03 C04 C05
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
3
.
D
W
G
SHOWN
C01 47 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PLAN VIEWPLAN VIEW
ST
O
R
M
W
A
T
E
R
P
L
A
N
A
N
D
P
R
O
F
I
L
E
0
1
NE
1
2
T
H
S
T
-
E
D
M
O
N
D
S
A
V
E
T
O
H
A
R
R
I
N
G
T
O
N
A
V
E
EXISTING POWER LINE TO
BE RELOCATED BY PSE
EXISTING GAS LINE TO BE
RELOCATED BY PSE
1175 HARRINGTON PL NE
TPN: 3122000000
2825 NE 12TH ST
TPN: 7227802045
2801 NE 12TH ST
TPN: 7227801680
1" METER ACCNT #003069
2810 NE 12TH ST
TPN: 7227801685
EXISTING 3/4" METER ACCNT
2902 NE 12TH ST
TPN: 7227802040
2908 NE 12TH ST
TPN: 7227801776
EXISTING 1-1/2" METER
ACCNT #3168-000
HA
R
R
I
N
G
T
O
N
P
L
N
E
NE 12TH STREET
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
12'' DI W (565)12'' DI W (565)12'' DI W (565)
PH6
PH7
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH G3
PH P4 PH P5
X
X
X
X
X
X
X
X\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\X X X X X X X X X X X X X X X X X X
\
\
\
X
X
X
X
X
X
XX
X
X
PPH21
GPH22
GPH23A GPH24
GPH25
PPH26
GPH27
GPH23B
CB #4
WITH RECTANGULAR
FRAME & VANED GRATE
4 CB #5
WITH RECTANGULAR
FRAME & VANED GRATE
5
00
A
19
00
A
20
00
A
21
00
A
22
00
A
23
CB #4 TO EX. SDMH PROFILE VIEW
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
-40 LF 0 LF 10 LF
CB #6 TO EX. SDMH PROFILE VIEW
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
-35 LF 0 LF 15 LF
8" PVC TO EX. SDMH PROFILE VIEW
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
-15 LF 0 LF 15 LF
PR
O
P
.
W
A
T
E
R
5
6
5
1
2
"
D
I
PR
O
P
.
W
A
T
E
R
5
6
5
1
2
"
D
I
CB #4 - TYPE IL
STA 20+55.5A, 19.1 L
RIM = 352.90'
8" DIP (OUT-S) IE = 350.50'
4
APPROX. 29'
OF 8" DIP @ 4.51%
8" DIP (IN NE) IE=349.97' (PROP.)
APPROX. 29'
OF 8" DIP @ 1.36%CB #5 - TYPE I
STA 23+21.0A, 19.2 L
RIM = 354.46'
8" DIP (OUT-S) IE = 351.73'
20+49A 23+20A
5A
PR
O
P
.
3
"
F
I
B
E
R
CR
O
S
S
I
N
G
PR
O
P
.
3
"
F
I
B
E
R
CR
O
S
S
I
N
G
PR
O
P
.
3
"
F
I
B
E
R
CR
O
S
S
I
N
G
PR
O
P
.
W
A
T
E
R
5
6
5
1
2
"
D
I
APPROX. 9'
OF 8" SDR 35 PVC @ 3.34%
8" PVC (IN NE) IE=348.55' (PROP.)
8" DIP (IN N) IE=351.35' (PROP.)
8" PVC (IN NE) IE=348.55' (PROP.)
8" DIP (IN N) IE=351.35' (PROP.)
5B
INSTALL ETHAFOAM
PADS WHERE
VERTICAL
CLEARANCE
BETWEEN UTILITIES
IS 6" OR LESS, TYP.
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS, TYP.
12'
GENERAL CONSTRUCTION NOTES
CONSTRUCTION NOTES
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
C01 C02 C03 C04 C05
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
3
.
D
W
G
SHOWN
C02 48 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PLAN VIEWPLAN VIEW
ST
O
R
M
W
A
T
E
R
P
L
A
N
A
N
D
P
R
O
F
I
L
E
0
2
NE
1
2
T
H
S
T
-
H
A
R
R
I
N
G
T
O
N
A
V
E
T
O
H
A
R
R
I
N
G
T
O
N
P
L
3011 NE SUNSET BLVD
TPN: 7227900019
METER SERVICE ON NE
SUNSET BLVDNA
TPN: 722790UNKN
3116 NE SUNSET BLVD
TPN: 0423059095
3/4" IRR METER ACCNT
#19835-000
3002 NE SUNSET BLVD
TPN: 7227800285
METER SERVICE ON
NE SUNSET BLVD
3116 SUNSET BLVD NE
TPN: 0423059095
3002 NE SUNSET BLVD
TPN: 7227800285
KI
R
K
L
A
N
D
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
12'' DI W (565)
16
'
'
D
I
W
(
4
3
5
)
12'' RJ DI W (565)
16
'
'
D
I
W
(
4
3
5
)
\\\\\\\\\\\\\\\\\\\\\\\\\\\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
X
X
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH13
PH14
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH G5
PH G6
PH G7
PH G8
PH G9
PH G10
PH P6
PH P7
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
X X X X X X X X X X X X X X X X X X X X X
\
\
\
\
\
\
X
X
X
X
X
X
X
X X X
XXX
XX
X
XX
\
\
\
\
\
X
X
X
X
X
\\\
GPH34
PPH35
PPH37
GPH38
PPH39
PPH40
PPH43
PPH44
GPH45
GPH47
GPH48
PPH46
PPH49
GPH50
GPH51
PPH52
PPH53
PPH56
PPH54
PPH55
PPH57
PPH59
PPH60
0 LF 100 LF 200 LF
300
L
F
400 LF
SDMH #1
WITH ROUND SOLID
FRAME & COVER
CB #6
WITH RECTANGULAR
FRAME & VANED GRATE
SDMH #2
WITH ROUND SOLID
FRAME & COVER
CB #7
WITH RECTANGULAR
SOLID FRAME & COVER
6
7
C0
4
M
A
T
C
H
L
I
N
E
S
T
A
31
+
8
0
A
C0
4
M
A
T
C
H
L
I
N
E
S
T
A
31
+
8
0
A
SDMH #4
WITH ROUND SOLID
FRAME & COVER
SDMH #3
WITH ROUND SOLID
FRAME & COVER
00
A
27
00
A
28
00
A
29
00
A
30
00
A
31
PROFILE VIEW
340'
350'
360'
370'
380'
340'
350'
360'
370'
380'
-10 LF 0 LF 100 LF 200 LF 300 LF 400 LF 445 LF
SDMH #1 - TYPE II 48"
STA 28+26.6A, 11.8 R
RIM = 359.15'
8" DIP (IN-S) IE = 354.75'
18" PP (OUT-W) IE = 353.77'
18" PP (IN-E) IE = 353.76'
SDMH #2 - TYPE II 48"
STA 29+89.2A, 11.6 R
RIM = 366.40'
18" DIP (IN-E) IE = 360.02'
18" PP (OUT-W) IE = 359.16'
6" RCP (IN-SW) IE = 361.57'
12" RCP (IN-S) IE = 359.47'
APPROX. 42'
OF 18" DIP @ -2.45%
SDMH #4 - TYPE II 48"
STA 30+36.9A, 11.6 R
RIM = 366.88'
18" PP (OUT-SW) IE = 361.00'
12" DIP (IN-E) IE = 361.45'
12" DIP (IN-NE) IE = 361.80'
APPROX. 236'
OF 12" DIP @ -1.85%
PR
O
P
.
W
A
T
E
R
4
3
5
1
2
"
D
I
APPROX. 91'
OF 18" PP @ -3.28%
APPROX. 163'
OF 18" PP @ -3.40%
APPROX. 11'
OF 18" PP @ 1.35%SDMH #3 - TYPE II 48"
STA 30+30.5A, 21.0 R
RIM = 366.73'
18" PP (IN-NE) IE = 360.90'
18" DIP (OUT-W) IE = 360.96'
12" RCP (IN-SW) IE = 361.33'
6" RCP (IN-S) IE = 362.73'
27+36A 28+36A 29+36A 30+33A 31+30A
18" PP (IN E) IE=350.85' (PROP.)
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS, TYP.
PR
O
P
.
3
"
F
I
B
E
R
CR
O
S
S
I
N
G
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS, TYP.
GENERAL CONSTRUCTION NOTES
CONSTRUCTION NOTES
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
C01 C02 C03 C04 C05
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
3
.
D
W
G
SHOWN
C03 49 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PLAN VIEWPLAN VIEW
ST
O
R
M
W
A
T
E
R
P
L
A
N
A
N
D
P
R
O
F
I
L
E
0
3
NE
1
2
T
H
S
T
-
K
I
R
K
L
A
N
D
A
V
E
T
O
L
Y
N
N
W
O
O
D
A
V
E
N
E
EXISTING POWER LINE TO
BE RELOCATED BY PSE
NO CONSTRUCTION ACTIVITIES AND/OR CLOSURE OF ROADWAY
LANES ARE PERMITTED AT THIS INTERSECTION FROM JUNE 1,
2026 TO JULY 15, 2026 PER SPECIAL PROVISIONS 1-8.0(2)
1170 MONROE AVE NE
TPN: 0923059170
3233 NE 12TH ST
TPN: 7801300000
METER SERVICES ON
LYNNWOOD
NA
TPN: 7227900018
3316 NE 12TH ST
TPN: 7736100015
3232 NE 12TH ST
TPN: 0423059316
3224 NE 12TH ST
TPN: 0423059169
3/4" METER ACCNT
#7720-000
3218 NE 12TH ST
TPN: 0423059182
1-1/2" METER
ACCNT #17721-00
3123 NE SUNSET BLVD
TPN: 0423059155
1" METER ACCNT
#157203-000
1" IRR METER ACCNT
#57203
3316 NE 12TH ST
TPN: 7736100015
LY
N
N
W
O
O
D
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
NE 12TH ST
12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH16
PH17
PH18 PH19
PH20
PH21
PH22PH22A
PH G11 PH G12
PH P9
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\\X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
XXXXXXXX
X
X
X
X
X\\\
\\\\\\XXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X \\
GPH61
GPH62
GPH63
GPH64
PPH67
PPH68
GPH71
500 LF 600 LF
700 LF
800 LF
900 LF
SDMH #5
WITH ROUND SOLID
FRAME & COVER
SDMH #6
WITH ROUND SOLID
FRAME & COVER
CB #8
WITH RECTANGULAR
FRAME & VANED GRATE
C0
3
M
A
T
C
H
L
I
N
E
S
T
A
31
+
8
0
A
C0
3
M
A
T
C
H
L
I
N
E
S
T
A
31
+
8
0
A
C0
5
M
A
T
C
H
L
I
N
E
S
T
A
36
+
6
2
A
C0
5
M
A
T
C
H
L
I
N
E
S
T
A
36
+
6
2
A
8
00
A
32
00
A
33
00
A
34
00
A
35
00
A
36
PROFILE VIEW
360'
370'
380'
390'
400'
360'
370'
380'
390'
400'
445 LF 500 LF 600 LF 700 LF 800 LF
PROFILE VIEW
380'
390'
400'
410'
420'
380'
390'
400'
410'
420'
800 LF 900 LF 915 LF
PR
O
P
.
W
A
T
E
R
5
6
5
1
2
"
D
I
PR
O
P
.
W
A
T
E
R
5
6
5
8
"
D
I
SDMH #5 - TYPE II 48"
STA 32+73.1A, 10.0 R
RIM = 374.74'
12" DIP (OUT-W) IE = 365.75'
12" DIP (IN-E) IE = 365.81'
6" RCP (IN-S) IE = 368.05'
8" CMP (IN-N) IE = 369.77'
8" CMP (IN-N) IE = 366.52'
12" PP (IN-SE) IE = 367.03'
APPROX. 263'
OF 12" DIP @ -10.30%
APPROX. 25'
OF 12" DIP @ -6.21%
CB #8 - TYPE I
STA 35+44.9A, 13.5 L
RIM = 401.94'
12" DIP (OUT-SW) IE = 396.50'
12" DIP (IN-E) IE = 398.75'
APPROX. 144'
OF 12" DIP @ -14.03%
SDMH #6 - TYPE II 48"
STA 35+34.5A, 9.2 R
RIM = 400.62'
12" DIP (OUT-W) IE = 392.47'
12" DIP (IN-NE) IE = 395.13'
6" RCP (IN-SW) IE = 395.42'
6" RCP (IN-E) IE = 395.41'
32+30A 33+30A 34+30A 35+30A 35+30A 36+15A
PR
O
P
.
3
"
F
I
B
E
R
CR
O
S
S
I
N
G
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS, TYP.
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS, TYP.
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS, TYP.
EXISTING POWER LINE TO
BE RELOCATED BY PSE
GENERAL CONSTRUCTION NOTES
CONSTRUCTION NOTES
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
C01 C02 C03 C04 C05
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
3
.
D
W
G
SHOWN
C04 50 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PLAN VIEWPLAN VIEW
ST
O
R
M
W
A
T
E
R
P
L
A
N
A
N
D
P
R
O
F
I
L
E
0
4
NE
1
2
T
H
S
T
-
M
O
N
R
O
E
A
V
E
T
O
O
L
Y
M
P
I
A
A
V
E
CONSTRUCT PROPOSED STORM IMPROVEMENTS
EAST OF MONROE AVE NE AFTER 565 ZONE WATER
MAIN IMPROVEMENTS AND ABANDONMENT OF 10" W
COORDINATE PHASING OF PROPOSED
IMPROVEMENTS WITH CITY OF RENTON
WEST OF MONROE AVE NEEXISTING POWER LINE TO
BE RELOCATED BY PSE
3323 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#59301-000
3317 NE 12TH ST
TPN: 0923059162
3/4" METER ACCNT
#24137-000
1204 MONROE AVE NE
TPN: 7736100055
3/4" METER ACCNT
#7801-000
3316 NE 12TH ST
TPN: 7736100015
MO
N
R
O
E
A
V
E
N
E
NE 12TH STNE 12TH ST
3401 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#44306-000
3417 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#54364-000
3410 NE 12TH ST
TPN: 0423059186
3327 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#7742-000
12'' DI W (565)
12'' DI W (565)
12'' DI W (565)
12'' DI W (565)
16'' DI W 16'' DI W
G G G G G G G G G G G G G G G
X
X
X
X
X
X
X
X
X
X
X
X
\
\
\
\
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\
\
\
\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH G13
PH G14
PH G15 PH G16
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
X X
X
X
X
X
X
X
X
GPH74
GPH75
GPH82
1000 LF
1100 LF 1200 LF
SDMH #7
WITH RECTANGULAR
FRAME & VANED GRATE
CB #10
WITH RECTANGULAR
FRAME & VANED GRATE
C0
4
M
A
T
C
H
L
I
N
E
S
T
A
36
+
6
2
A
C0
4
M
A
T
C
H
L
I
N
E
S
T
A
36
+
6
2
A
C0
6
M
A
T
C
H
L
I
N
E
S
T
A
41
+
4
2
A
C0
6
M
A
T
C
H
L
I
N
E
S
T
A
41
+
4
2
A
CB #9
WITH RECTANGULAR
FRAME & VANED GRATE
CB #11
WITH RECTANGULAR
FRAME & VANED GRATE
00
A
37
00
A
38
00
A
39
00
A
40
00
A
41
00B10
00B11
PROFILE VIEW
405'
410'
420'
430'
440'
405'
410'
420'
430'
440'
925 LF 1000 LF 1100 LF 1200 LF 1275 LF
PR
O
P
.
W
A
T
E
R
5
6
5
8
"
D
I
PR
O
P
.
W
A
T
E
R
5
6
5
6
"
D
I
PR
O
P
.
W
A
T
E
R
5
6
5
1
2
"
D
I
CB #9 - TYPE I
STA 36+87.1A, 16.2 L
RIM = 422.00'
12" DIP (OUT-W) IE = 418.60'
12" DIP (IN-E) IE = 418.70'
SDMH #7 - TYPE II 48"
STA 37+53.9A, 16.0 L
RIM = 429.37'
12" DIP (OUT-W) IE = 422.50'
12" DIP (IN-E) IE = 425.63'
CB #10 - TYPE I
STA 38+78.9A, 17.1 L
RIM = 437.55'
12" DIP (OUT-W) IE = 434.40'
12" DIP (IN-E) IE = 434.50'
CB #11 - TYPE I
STA 39+79.6A, 17.1 L
RIM = 439.15'
12" DIP (OUT-W) IE = 435.84'
APPROX. 67'
OF 12" DIP @ -5.96%
APPROX. 125'
OF 12" DIP @ -7.16%
APPROX. 101'
OF 12" DIP @ -1.36%
37+15A 38+15A 39+15A
PR
O
P
.
3
"
F
I
B
E
R
CR
O
S
S
I
N
G
INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS, TYP.INSTALL ETHAFOAM PADS
WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS, TYP.
GENERAL CONSTRUCTION NOTES
CONSTRUCTION NOTES
= PERFORM SITE SPECIFIC POTHOLING PRIOR TO PIPE INSTALLATION
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
C01 C02 C03 C04 C05
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
3
.
D
W
G
SHOWN
C05 51 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
PLAN VIEWPLAN VIEW
ST
O
R
M
W
A
T
E
R
P
L
A
N
A
N
D
P
R
O
F
I
L
E
0
5
NE
1
2
T
H
S
T
-
M
O
N
R
O
E
A
V
E
T
O
O
L
Y
M
P
I
A
A
V
E
CB #7 TO SDMH #5 PROFILE VIEW
340'
350'
360'
370'
380'
340'
350'
360'
370'
380'
-60 LF 0 LF 20 LF
EX. SDMH #10232 TO SDMH #6 PROFILE VIEW
350'
360'
370'
380'
390'
350'
360'
370'
380'
390'
-10 LF 0 LF 60 LF
SDMH #3 TO CB #6 PROFILE VIEW
330'
340'
350'
360'
370'
330'
340'
350'
360'
370'
-15 LF 0 LF 25 LF
PR
O
P
.
W
A
T
E
R
5
6
5
1
2
"
D
I
SDMH #1 - TYPE II 48"
STA 28+26.6A, 11.8 R
RIM = 359.15'
8" DIP (IN-S) IE = 354.75'
18" PP (OUT-W) IE = 353.77'
18" PP (IN-E) IE = 353.76'
CB #6 - TYPE I
STA 28+26.9A, 19.1 R
RIM = 358.87'
8" DIP (OUT-N) IE = 354.85'
6" RCP (IN-S) IE = 356.44'
SDMH #4 - TYPE II 48"
STA 30+36.9A, 11.6 R
RIM = 366.88'
18" PP (OUT-SW) IE = 361.00'
12" DIP (IN-E) IE = 361.45'
12" DIP (IN-NE) IE = 361.80'
CB #7 - TYPE I
STA 30+66.4A, 31.8 L
RIM = 366.74'
12" DIP (OUT-SW) IE = 363.68'
12" RCP (IN-NE) IE = 363.78'
APPROX. 52'
OF 12" DIP @ 3.80%
6 7
APPROX. 7'
OF 8" DIP @ -2.26%
28+27A 30+37A
SEE DWG NO. C03
FOR INFORMATION
SDMH #5 - TYPE II 48"
STA 32+73.1A, 10.0 R
RIM = 374.74'
12" DIP (OUT-W) IE = 365.75'
12" DIP (IN-E) IE = 365.81'
6" RCP (IN-S) IE = 368.05'
8" CMP (IN-N) IE = 369.77'
8" CMP (IN-N) IE = 366.52'
12" PP (IN-SE) IE = 367.03'
12" PP (OUT NW) IE=367.85' (PROP.)
8
32+73A
APPROX. 55'
OF 12" PP @ 1.61%
INSTALL ETHAFOAM
PADS WHERE VERTICAL
CLEARANCE BETWEEN
UTILITIES IS 6" OR LESS,
TYP.
MATCH EXISTING STORM PIPE
CORRIDOR. PROVIDE ETHAFOAM
PADS WHERE VERTICAL CLEARANCE
BETWEEN UTILITIES IS 6" OR LESS.
EXISTING POWER LINE TO
BE RELOCATED BY PSE
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
3
.
D
W
G
SHOWN
C06 52 71
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
ST
O
R
M
W
A
T
E
R
P
R
O
F
I
L
E
S
\
\
\
\
\
\
PH1
PH1A
PH2
PH2A
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\PH G1 PH P1
\\\\\\\\\\\\\\\\\\\\\\
\
\
\
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXXXXXXXXXX X X X X X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
PPH2
PPH3
GPH4
GPH5
GPH6
GPH7
GPH8
PPH9
PPH11
8'' CP SS
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
2601 & 2603 NE 12TH ST
TPN: 7227801335
1" LATERAL 3/4" METER
ACCNT #003066
NA
TPN: 0923059102
NO METER
2527 NE 12TH ST
TPN: 0923059062
1" LATERAL 3/4"
METER ACCNT
#140025
1140 EDMONDS AVE NE
TPN: 0923059061
METER ON EDMONDS
1190 EDMONDS PL NE
TPN: 2270000020
1194 EDMONDS PL NE
TPN: 2270000010
2430 NE 12TH ST
TPN: 2309200010
JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
ED
M
O
N
D
S
A
V
E
N
E
NE 12TH STREET
P P P P
P
P P P P P P P PP
P
8'' AC W (435)
16
'
'
D
I
W
(
4
3
5
)
8'
'
C
I
W
(
4
3
5
)
8'
'
C
I
W
(
4
3
5
)
8'' AC W (435)12'' AC W (435)12'' AC W (435)12'' AC W (435)12'' AC W (435)12'' AC W (435)
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
W
16
'
'
D
I
W
(
4
3
5
)
16
'
'
D
I
W
(
4
3
5
)
W
P
P
P
P P P P P
P P P P PPPPPP
P P P P PPPPPP
P
P
P
P
P
P
P
P
P
P
W
T
E
L
T
E
L
TE
L
TEL
TE
L
TE
L
TEL TEL TEL TEL
TEL TEL TEL TEL
TE
L
TE
L
TEL TEL TEL TEL TEL TEL TEL TEL
TE
L
TE
L
TEL TEL TEL TEL
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
CO
R
T
E
L
M
G
G G
6'' IP G 6'' IP G 6'' IP G
G G
G
G
18
'
'
C
O
N
C
S
T
18
'
'
C
O
N
C
S
T
8'' CONC ST
8
'
'
C
O
N
C
S
T
12'' CONC ST
36'' CPEP ST
10''
C
O
N
C
S
T
12'' ST (ABAN)12'' ST (ABAN)
12'' ST (ABAN)12'' ST (ABAN)36'' CMP ST
36'' CMP ST
36'' CMP ST
ST
36'' CMP ST
G
G
x x x x x x x x x x x x x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x x xxx
x
x
x x x x x x x x x x x
x
x
x
x x x x x x x x x
x
x
x
x
G
G
12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)
12
'
'
D
I
W
(
5
6
5
)
FO FO FO FO FO FO FO FO FO FO FO FO FO
FO
2
STA 9+82.2A, 36.0' L
CONNECT TO EXISTING VAULT 1
STA 13+81.5A, 25.4' L
PROPOSED JUNCTION BOX3
2
MA
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
MA
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
00
A
10
00
A
11
00
A
12
00
A
13
00
A
14
1
FIBER CONSTRUCTION NOTES
2
3
GENERAL CONSTRUCTION NOTES
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
E01 E02 E03 E04
PH4
PH5
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
PH G2PH P2 PH P3
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\
\\\
\
\\\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
X
XX
X
X
X
PPH12
PPH13 GPH14 PPH15
PPH17
GPH18
PPH20
8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS
8'
'
C
O
N
C
S
S
8'
'
C
O
N
C
S
S
4
'
'
C
O
N
C
S
S
SS SS
SS
SS
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
6'
'
C
O
N
C
S
S
1174 HARRINGTON AVE NE
TPN: 7227801675
METER SERVICE ON HARRINGTON
1177 HARRINGTON AVE NE
TPN: 7227801355
METER SERVICE ON HARRINGTON
2613 & 2615 NE 12TH ST
TPN: 7227801345
1" LATERAL 3/4" METER
ACCNT #003069
2607 & 2609 NE 12TH ST
TPN: 7227801340
1" LATERAL 3/4" METER
ACCNT #003067
JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
NA
TPN: 7227801860
METER SERVICE ON HARRINGTON
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
NE 12TH STREET
P P P
P P P
P
P
P
PPPPPPP
P
P
12'' AC W (435)12'' AC W (435)
16'' DI W (435)16'' DI W (435)16'' DI W (435)
12'' AC W (435)
12'' AC W (435)
W
P P P P P P
P
P P P P
P
P
P P P P P
P
P P P P P P
P P P P P P P
12
A
C
W
(
A
B
A
N
)
16'' DI W (435)16'' DI W (435)
8'' AC W (ABAN)8'' AC W (ABAN)
TEL TEL TEL
TE
L
TE
L
TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL
T
E
L
T
E
L
TE
L
TE
L
T
E
L
T
E
L
TE
L
TE
L
T
E
L
TEL TEL TEL
TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL
6'' IP G
GG
G
GG
6'' IP G 6'' IP G 6'' IP G 6'' IP G
8'
'
C
I
W
(
5
6
5
)
G
G
G
G
12'
'
D
I
W
(
5
6
5
)
8'' CI W (565)8'' CI W (565)
12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
8'
'
C
O
N
C
S
T
18
'
'
C
P
P
S
T
36'' CMP ST 36'' CMP ST
12'' ST 12'' ST
36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST
12
'
'
A
D
S
S
T
1
2
'
'
A
D
S
S
T
8''
C
O
N
C
S
T
x
x x x x x x x x x x x x x x x x x x x
x
x
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
x
x
x
TEL TEL TEL TEL TEL TEL TEL TEL TEL
8'
'
D
I
W
G
12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
2
STA 17+38.3A, 22.4' L
PROPOSED JUNCTION BOX3
2
MA
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
MA
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
MA
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
MA
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
00
A
15
00
A
16
00
A
17
00
A
18
00
A
19
KEY PLAN
ID
O
CM
R
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
E
0
1
.
D
W
G
SHOWN
E01 53 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EL
E
C
T
R
I
C
A
L
A
N
D
C
O
M
M
U
N
I
C
A
T
I
O
N
P
L
A
N
0
1
PLAN VIEW
PLAN VIEW
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
PH6
PH7
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH G3
PH P4 PH P5
X
X
X
X
X
X
X
X\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\X X X X X X X X X X X X X X X X X X
\
\
\
X
X
X
X
X
X
XX
X
X
PPH21
GPH22
GPH23A GPH24
GPH25
PPH26
GPH27
GPH23B
8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SS SS
SS SS
4
'
'
C
O
N
C
S
S
SS
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SS
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SS
1175 HARRINGTON PL NE
TPN: 3122000000
2825 NE 12TH ST
TPN: 7227802045
2801 NE 12TH ST
TPN: 7227801680
1" METER ACCNT #003069
2810 NE 12TH ST
TPN: 7227801685
EXISTING 3/4" METER ACCNT
2902 NE 12TH ST
TPN: 7227802040
2908 NE 12TH ST
TPN: 7227801776
EXISTING 1-1/2" METER
ACCNT #3168-000
HA
R
R
I
N
G
T
O
N
P
L
N
E
NE 12TH STREET
PP
P
P
P P P P
8''
C
I
W
(
4
3
5
)
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
P P
P
P P P P PPPPP P P P P P P PP
8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)
TEL
TE
L
TE
L
TEL
TEL
T
E
L
TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TELTELTELTELTELTEL
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL
TE
L
TE
L
TE
L
TEL TEL TEL TEL
8'' CI W (565)
W
W
8'' CI W (565)
8'
'
D
I
W
(
5
6
5
)
4''
I
P
G
6'' IP G 6'' IP G 6'' IP G 6'' IP G 6'' IP G 6'' IP G6'' IP G6'' IP G
G
8'' CI W (565)8'' CI W (565)
36'' CMP ST 36'' CMP ST
12'' ST 12'' ST 12'' ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST
12
'
'
C
O
N
C
S
T
36'' CMP ST
12'' ST (ABAN)
6'
'
C
O
N
C
S
T
x
x
x
x
W
P P P
P
P
P
P
P
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
(
5
6
5
)
8'' CI W (565)8'' CI W (565)
2'' STL G (ABND)2'' STL G (ABND)
12'' DI W (565)12'' DI W (565)12'' DI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
2
STA 21+46.4A, 24.0' L
PROPOSED JUNCTION BOX3
2
STA 23+69.9A, 23.3' L
PROPOSED JUNCTION BOX3
MA
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
MA
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
MA
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
MA
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
00
A
19
00
A
20
00
A
21
00
A
22
00
A
23
FIBER CONSTRUCTION NOTES
2
3
GENERAL CONSTRUCTION NOTES
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
E01 E02 E03 E04
PH9
PH10
PH11
PH12
PH12A
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\
\
\
\
\
\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH G4 PH G5
PH P6
X
X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X
\
\
\
\
\
\
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
\\\
PPH29 GPH30 PPH31 PPH32
GPH34
PPH35
PPH37
GPH38
PPH39
PPH40
NE 12TH ST
8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS 8'' CP SS
8'
'
S
S
(
A
B
A
N
)
8'
'
S
S
(
A
B
A
N
)
8'
'
S
S
(
A
B
A
N
)
8'
'
P
V
C
S
S
8'
'
S
S
8'
'
S
S
S
S
(
A
B
A
N
)
S
S
(
A
B
A
N
)
SSSSSSSS
FIRE STATION #12
1209 KIRKLAND AVE NE
TPN: 7227801450
4" DCDA W/ 3/4" METER
ACCNT #61583-001
1-1/2" IRR METER ACCNT
#61583-002
2" DOM METER ACCNT
#61583-000
1171 KIRKLAND AVE NE
TPN: 7227801406
975 HARRINGTON PL NE
TPN: 7227801405
3116 SUNSET BLVD NE
TPN: 0423059095
3002 NE SUNSET BLVD
TPN: 7227800285
KI
R
K
L
A
N
D
A
V
E
N
E
J
E
F
F
E
R
S
O
N
A
V
E
N
E
NE 12TH STREET
P P
P
P
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
P P P
P
P
PPPP
P
16'' DI W (435)16'' DI W (435)
OH
P
P
P P
P P PP P
8'' AC W (ABAN)8'' AC W (ABAN)
8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)
TE
L
TE
L
TEL TEL TELTELTELTELTELTELTEL
TEL
TE
L
TEL TEL TEL
TE
L
TEL TEL TEL TEL
TE
L
TE
L
TEL TEL TELTELTELTELTELTELTELTELTELTELTEL
TEL TEL TEL
TEL TEL
TE
L
TE
L
TE
L
TE
L
TEL TEL
TEL TEL
8'' CI W (565)8'' CI W (565)8'' CI W (565)8'' CI W (565)
W W
8'
'
D
I
W
(
5
6
5
)
4'' IP G4'' IP G 4'' IP G
4'' IP G 4'' IP G 4'' IP G
G
2'
'
I
P
G
2'
'
I
P
G
4'' IP G
6'' IP G
G
FO FO FO
12'' ST (ABAN)12'' ST (ABAN)
S
D
36'' CMP ST 36'' CMP ST 36'' CMP ST 36'' CMP ST
6
'
'
C
M
P
S
T
S
D
SD
SD
SD
6''
P
V
C
S
T
6
'
'
C
O
N
C
S
T
18
'
'
C
M
P
S
T
12'' ADS ST
12'' CONC ST 12'' CONC ST
12
S
T
12
S
T
x
x
x
10
'
'
S
T
L
W
(
A
B
N
)
10
'
'
C
I
(
5
6
5
)
W
P
P
P
P
P P P P
P
P
P
CO
R
T
E
L
M
CO
R
T
E
L
M
COR TELM COR TELM
P P P P P P P P
12
'
'
D
I
W
6'
'
C
I
W
(
A
B
A
N
)
18
'
'
D
I
S
T
1
2
'
'
D
I
S
T
12'
'
S
T
12
'
'
S
T
12
'
'
S
T
12
'
'
S
T
6'
'
C
O
N
C
S
S
(
A
B
A
N
)
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
WS
PP PP
10
'
'
C
I
W
(
5
6
5
)
10
'
'
C
I
W
(
5
6
5
)
12'' DI W (565)12'' DI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
2
STA 26+31.5A, 22.2' L
PROPOSED JUNCTION BOX 3
2
MA
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
MA
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
MA
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
MA
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
00
A
24
00
A
25
00
A
26
00
A
27
00
A
28
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
ID
O
CM
R
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
E
0
1
.
D
W
G
SHOWN
E02 54 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EL
E
C
T
R
I
C
A
L
A
N
D
C
O
M
M
U
N
I
C
A
T
I
O
N
P
L
A
N
0
2
PLAN VIEW
PLAN VIEW
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
X
X
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH13
PH14
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
PH G6
PH G7
PH G8
PH G9
PH G10
PH P7
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X
X X X
XXX
XX
X
XX
\
\
\
\
\
X
PPH43
PPH44
GPH45
GPH47
GPH48
PPH46
PPH49
GPH50
GPH51
PPH52
PPH53
PPH56
PPH54
PPH55
PPH57
PPH59
PPH60
8'' CP SS 8'' CP SS 8'' CP SS
8
'
'
C
P
S
S
8
'
'
C
P
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
18
'
'
P
V
C
S
S
8''
S
S
8''
S
S
8''
C
P
S
S
8''
C
P
S
S
SS SS
NA
TPN: 7227900018
3011 NE SUNSET BLVD
TPN: 7227900019
METER SERVICE ON NE
SUNSET BLVD
NA
TPN: 722790UNKN
3123 NE SUNSET BLVD
TPN: 0423059155
1" METER ACCNT
#157203-000
1" IRR METER ACCNT
#57203
3116 NE SUNSET BLVD
TPN: 0423059095
3/4" IRR METER ACCNT
#19835-000
3002 NE SUNSET BLVD
TPN: 7227800285
METER SERVICE ON
NE SUNSET BLVD
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
P
P
16'' DI W (435)16'' DI W (435)
P P
10'' CI W (435
)
16'' DI W (435)16'' DI W (435)
P P P P
P
P
P
16'' DI W (435)
10
'
'
C
I
W
(
4
3
5
)
P
P P P P P P P P P PPPPPPPPPPPPP
P P PP
P
P
P
P
P
P
P
P
P
P
10'' CI W (435)
8'' AC W (ABAN)8'' AC W (ABAN)8'' AC W (ABAN)
8'
'
A
C
W
(
A
B
A
N
)
6'
'
C
I
W
(
4
3
5
)
TEL TEL TEL
TEL TEL TEL TEL TEL
TE
L
TEL TEL TEL TEL
TEL
TEL TEL TEL TEL
TEL
TEL TE
L
TE
L
TEL TEL
TEL
T
E
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
TE
L
4'' STL W (ABN)4'' STL W (ABN)4'' STL W (ABN)
10'' CI W (565)10'' CI W (565)10'' CI W (565)
W
2'' IP G 2'' IP G
4''
I
P
G
4''
I
P
G
G
4'' IP G 4'' IP G 4'' IP G
G
G
G
G
12
'
'
D
I
W
(
5
6
5
)
10'' CI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO
FO
FO
FO FO FO FO FO FO FO FO FO
12'' CONC ST 12'' CONC ST 12'' CONC ST
18
'
'
C
O
N
C
S
T
18
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
12
'
'
C
O
N
C
S
T
SD
12
'
'
C
O
N
C
S
T
1
2
'
'
S
T
4''
C
I
W
(
A
B
A
N
)
4''
C
I
W
(
A
B
A
N
)
12
'
'
D
I
W
(
5
6
5
)
12
'
'
D
I
W
(
5
6
5
)
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
G
G
G
12'' CONC ST
12'' CONC ST
12'' CONC ST
12'' CONC ST
12'' DI W (565)
16
'
'
D
I
W
(
4
3
5
)
12'' RJ DI W (565)12'' DI W (565)
16
'
'
D
I
W
(
4
3
5
)
FO FO FO FO FO FO FO FO FO FO FO FO FO
STA 29+10.9A, 28.4' L
PROPOSED JUNCTION BOX3
2 2
STA 31+04.2A, 28.1' R
PROPOSED SMALL CABLE VAULT 4
2
MA
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
MA
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
MA
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
MA
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
00
A
29
00
A
30
00
A
31
00
A
32
FIBER CONSTRUCTION NOTES
2
3
GENERAL CONSTRUCTION NOTES
4
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
E01 E02 E03 E04
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH16
PH17
PH18 PH19
PH20
PH21
PH22
PH22A
PH G11 PH G12
PH P9
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
XXXXXXXX
X
X
X
X
X\\\
\\\\\\XXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X \\
GPH61
GPH62
GPH63
GPH64
PPH67
PPH68
GPH71
8'
'
P
V
C
S
S
8'' PVC SS
8'' PVC SS
8'' CLAY SS
8'' CLAY SS
8'' CLAY SS
8'' CLAY SS
8'' CLAY SS
8
'
'
P
V
C
S
S
1170 MONROE AVE NE
TPN: 0923059170
3233 NE 12TH ST
TPN: 7801300000
METER SERVICES ON
LYNNWOODTPN: 7227900018
3316 NE 12TH ST
TPN: 7736100015
3232 NE 12TH ST
TPN: 0423059316
3224 NE 12TH ST
TPN: 0423059169
3/4" METER ACCNT
#7720-000
3218 NE 12TH ST
TPN: 0423059182
1-1/2" METER
ACCNT #17721-00
LY
N
N
W
O
O
D
A
V
E
N
E
M
O
N
R
O
E
A
V
E
N
E
NE 12TH ST
P
P
P
16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)16'' DI W (435)
OHP OHP
OH
P
OH
P
OH
P
OH
P
O
H
P
OHP OHP OHP OHP OHP
OHP
O
H
P
O
H
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
P
P
10'' CI W (435)10'' CI W (435)10'' CI W (435)10'' CI W (435)
10'' CI W (435)
TEL
TELTELTEL
TEL TEL TEL TEL TEL TEL
TEL
TEL TEL TEL TEL TEL TEL TEL TEL
TEL TEL TEL
TE
L
TE
L
T
E
L
TE
L
TE
L
TE
L
4'' STL W (ABN)
10
'
'
D
I
W
(
5
6
5
)
10
'
'
D
I
W
(
5
6
5
)
W
W
6'' DI W (565)6'' DI W (565)
8'
'
C
I
W
(
5
6
5
)
4'' IP G
G
4'' IP G
2'' IP G 2'' IP G 2'' IP G 2'' IP G 2'' IP G
2'
'
I
P
G
G
G
4'
'
C
I
W
(
5
6
5
)
10'' CI W (565)10'' CI W (565)10'' CI W (565)10'' CI W (565)10'' CI W (565)10'' CI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
1
2
'
'
C
M
P
S
T
12'' ST 12'' ST
6''
C
O
N
C
S
T
12'' CONC ST (ABAN)12'' CONC ST 12'' CONC ST 12'' CONC ST 12'' CONC ST
8'
'
C
M
P
S
T
8
'
'
C
M
P
S
T
FO
x
x
x
x
x
xxxxxxxxxxxx
x
x
x
x
xxxxxxxx
x x x
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
CO
R
T
E
L
M
COR TELM COR TELM
ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W
4''
C
O
N
C
S
S
4''
C
O
N
C
S
S
4''
C
O
N
C
S
S
4''
C
O
N
C
S
S
CLAY UNKNOWN SIZE SS CLAY UNKNOWN SIZE SS CLAY UNKNOWN SIZE SS CLAY UNKNOWN SIZE SS
6'
'
P
V
C
S
S
6'
'
P
V
C
S
S
4'
'
C
O
N
C
S
S
4'
'
C
O
N
C
S
S
12'' DI W (565)12'' DI W (565)12'' DI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
2
3
2
MA
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
MA
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
MA
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
MA
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
STA 36+11.8A, 26.4' R
PROPOSED JUNCTION BOX
00
A
33
00
A
34
00
A
35
00
A
36
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
ID
O
CM
R
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
E
0
1
.
D
W
G
SHOWN
E03 55 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EL
E
C
T
R
I
C
A
L
A
N
D
C
O
M
M
U
N
I
C
A
T
I
O
N
P
L
A
N
0
3
PLAN VIEW
PLAN VIEW
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\
\
\
\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
PH G13
PH G14
PH G15
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
X
X X
X
X
X
X
X
X
X
GPH74
GPH75
GPH82
x x x x x x x
x
x
x
x
x x x x x x
x x x x x x x x x
x
x
x
P PP
P
T
E
L
T
E
L
TEL TEL TEL
TEL TEL
TEL
TEL TELTEL
TEL TEL TELTELTELTEL
TELTELTEL
TEL TEL TEL TEL TEL
TEL
P
P
OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
OHP
OHP
OHP OHP
x
x
x
x
x
xxxxxx
x
x
x
x
P
16'' CI W 16'' CI W 16'' CI W
G G G G G G
P
P
G G G G G
W
10'' CI W 10'' CI W 10'' CI W
16
'
'
C
I
W
TELTELTELTEL
TE
L
TE
L
TE
L
16
'
'
C
I
W
x x x x x x x x x x x x
x x x
TEL
TE
L
12'' CI W
8'' CLAY SS
8'' CLAY SS 8'' CONC SS 8'' CONC SS 8'' CONC SS 8'' CONC SS
W
3323 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#59301-000
3317 NE 12TH ST
TPN: 0923059162
3/4" METER ACCNT
#24137-000
1204 MONROE AVE NE
TPN: 7736100055
3/4" METER ACCNT
#7801-000
3316 NE 12TH ST
TPN: 7736100015
MO
N
R
O
E
A
V
E
N
E
NE 12TH ST
OHP OHP OHP
O
H
P
O
H
P
OH
P
OH
P
12'' CI W (435)
12'' CI W (435)12'' CI W (435)
16'' DI W (435)16'' DI W (435)16'' DI W (435)
O
H
P
O
H
P
O
H
P
O
H
P
O
H
P
OHP
OHP
OHP OHP OHP OHP
OH
P
10'' CI W (435)
TEL TEL
TEL TEL TEL
TEL TEL TELTEL
TEL
TE
L
TE
L
TE
L
TE
L
TEL TEL TEL TEL TEL TELTELTELTELTELTELTEL
TEL TEL TEL
TEL
G G
G G G 4'' IP G
4'
'
I
P
G
4'
'
I
P
G
8'
'
D
I
W
(
5
6
5
)
W
G
G
4'' IP G
10'' CI W (565)10'' CI W (565)10'' CI W (565)
FO FOFO
x x x x x x x
x
x x
x
x
x
x x x x
x
T
E
L
TEL
P
P
3410 NE 12TH ST
TPN: 0423059186
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM COR TELM
CO
R
T
E
L
M
ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W ABND W
ABN
D
W
ABN
D
W
ABN
D
W
ABN
D
W
ABN
D
W
ABN
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
ABND WABND WABND WABND WABND WABND W
ABND WABND W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
AB
N
D
W
3327 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#7742-000
CLAY UNKNOWN SIZE SS
6'
'
C
O
N
C
S
S
4'
'
S
S
(
A
B
A
N
)
12'' DI W (565)
12'' DI W (565)
G G G G G G G
FO FO FO FO FO FO FO
2
MA
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
MA
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
STA 38+73.1A, 22.6' R
PROPOSED JUNCTION BOX3
6
5
78
FO
00
A
37
00
A
38
00
A
39
00B10
FIBER CONSTRUCTION NOTES
2
3
5
6
7
GENERAL CONSTRUCTION NOTES
8
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
E01 E02 E03 E04
LOW LIMIT PIPE ZONE
RED ELECTRICAL WARNING TAPE
CENTERED OVER CONDUIT IN TRENCH
2'-0"
CSBC COMPACTED TO A NON-YIELDING
CONDITION, REQ'D FOR UNSTABLE
SOILS, SEE TRENCH NOTE
SAND BEDDING MATERIAL PER
SECTION 9-03.13 COMPACTED TO 95%
OF MAX DENSITY
TRENCH BACKFILL, GRAVEL BORROW
PER SECTION 9-03.14(1) COMPACTED
TO 95% OF MAX DENSITY
UPPER LIMIT PIPE ZONE
3" SCH. 80 PVC CONDUIT
PIPE COVER
DEPTH OF COVER MEASURED FROM FINISHED GRADE TO
TOP OF 3" SCH. 80 PVC CONDUIT SHALL BE MINIMUM 36".
NOTE:
WHEN POOR QUALITY FOUNDATION IS ENCOUNTERED BELOW THE
BEDDING ZONE OR WHEN DIRECTED BY THE ENGINEER, OVER-EXCAVATE
AND PROVIDE AND INSTALL CSBC, MEETING THE REQUIREMENTS OF STD.
SPEC. 9-03.9(2). THE USE OF GEOTEXTILE SEPARATION FABRIC MAY ALSO
BE REQUIRED TO STABILIZE THE BASE.
3" MIN.
8" MIN.
9"
EXISTING ASPHALT
2" SAWCUT AND REMOVE OR PLANE
SEAL WITH AR-400W (EACH SIDE)
PERMANENT HMA, CL. 1/2" PG 58H-22
TO MATCH THICKNESS OF EXISTING
ASPHALT OR 8" MINIMUM
CSTC PER SECTION 9-03.9(3) COMPACTED TO
95% OF MAX DENSITY, MIN. 6" THICKNESS.
1' MIN.1' MIN.1' MIN.1' MIN.
NEAT LINE TRENCH
E1TYPICAL TRANSVERSE 3" SCH. 80 PVC CONDUIT TRENCH
WITH HMA PAVEMENT AND OVERLAY SECTION
NOT TO SCALE
2'-0"1' MIN.1' MIN.1' MIN.1' MIN.
2" GRIND AND
HMA OVERLAY
HMA PERMANENT PATCH
T-CUT. MATCH EXISTING HMA
THICKNESS, MIN. 8" THICKNESS.
NEAT LINE TRENCH
TRENCH BACKFILL
3" SCH. 80 PVC CONDUIT
TYPICAL TRANSVERSE 3" SCH. 80 PVC CONDUIT TRENCH
WITH HMA PAVEMENT AND OVERLAY PLAN VIEW
NOT TO SCALE
6' MIN.
2" HMA CL. 1/2" PG 58H-22 OVERLAY
DEPTH OF EXISTING
PAVEMENT
SAWCUT AFTER BACKFILL
(EACH SIDE)
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
ID
O
CM
R
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
E
0
1
.
D
W
G
SHOWN
E04 56 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
EL
E
C
T
R
I
C
A
L
A
N
D
C
O
M
M
U
N
I
C
A
T
I
O
N
P
L
A
N
0
4
PLAN VIEW
2601 & 2603 NE 12TH ST
TPN: 7227801335
1" LATERAL 3/4" METER
ACCNT #003066
NA
TPN: 0923059102
NO METER
2527 NE 12TH ST
TPN: 0923059062
1" LATERAL 3/4"
METER ACCNT
#140025
1140 EDMONDS AVE NE
TPN: 0923059061
METER ON EDMONDS
1190 EDMONDS PL NE
TPN: 2270000020
1194 EDMONDS PL NE
TPN: 2270000010
2430 NE 12TH ST
TPN: 2309200010
JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
ED
M
O
N
D
S
A
V
E
N
E
NE 12TH STREET
G
G G
x x x x x x x x x x x x x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x x x
x x
x
x
x x x x x x x x x x x
x
x
x
x x x x x x x x x
x
x
x
x
00
A
10
00
A
11
00
A
12
00
A
13
00
A
14
12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)
12
'
'
D
I
W
(
5
6
5
)
FO FO FO FO FO FO FO FO FO FO FO FO FO
FO
MA
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
MA
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
STA 9+41.2A, 20.8' L
EDGE OF ROAD
STA 10+21.9A, 54.5' R
EDGE OF ROAD
STA 10+21.4A, 71.4' L
EDGE OF ROAD
STA 9+40.5A, 16.1' R
EDGE OF ROAD
STA 9+77.4A, 54.2' R
EDGE OF ROAD
STA 9+78.2A, 71.3' L
EDGE OF ROAD
R0
2
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
R0
2
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
R01 R02 R03 R04 R05 R06 R07 R08 R09
R1
0
2601 & 2603 NE 12TH ST
TPN: 7227801335
1" LATERAL 3/4" METER
ACCNT #003066
NA
TPN: 0923059102
NO METER
2527 NE 12TH ST
TPN: 0923059062
1" LATERAL 3/4"
METER ACCNT
#140025
1140 EDMONDS AVE NE
TPN: 0923059061
METER ON EDMONDS
1190 EDMONDS PL NE
TPN: 2270000020
1194 EDMONDS PL NE
TPN: 2270000010
2430 NE 12TH ST
TPN: 2309200010
JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
ED
M
O
N
D
S
A
V
E
N
E
NE 12TH STREET
G
G G
x x x x x x x x x x x x x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x x x
x x
x
x
x x x x x x x x x x x
x
x
x x x x x x x x x x
x
x
x
x
00
A
10
00
A
11
00
A
12
00
A
13
00
A
14
STA 9+82.2A, 38.0' L
END CROSSWALK
STA 9+78.6A, 48.8' L
END CROSSWALK
STA 9+78.6A, 55.0' L
END STOP BAR
STA 9+98.9A, 55.0' L
END STOP BAR
STA 10+21.0A, 51.7' L
END CROSSWALK
STA 10+24.9A, 34.4' L
END CROSSWALK
STA 10+36.1A, 23.1' L
END CROSSWALK
STA 9+67.3A, 24.3' R
END STOP BAR
STA 10+00.8A, 45.3' R
END STOP BAR
STA 10+20.6A, 45.4' R
END STOP BAR
STA 9+40.9A, 6.3' L
END DBL YEL
STA 11+37.0A, 0.0' R
END DBL YEL
STA 9+68.9A, 5.7' L
END DBL YEL
STA 9+68.9A, 5.2' L
END STOP BAR
STA 9+99.4A, 24.6' R
BEGIN 29.1' RADIUS
STA 9+99.3A, 43.3' R
END YEL EXT
STA 9+69.5A, 5.7' L
END YEL EXT
STA 10+41.6A, 0.0' R
END DBL YEL
STA 10+41.6A, 1.1' L
END STOP BAR
STA 10+57.4A, 0.8' L
HYDRANT MARKER
STA 10+37.0A, 19.6' R
END CROSSWALK
STA 10+26.0A, 22.8' R
END CROSSWALK
STA 10+85.0A, 0.8' L
HYDRANT MARKER
STA 10+41.2A, 21.0' L
END STOP BAR
STA 9+99.3A, 45.3' R
DBL YEL
STA 10+10.4A, 46.1' R
END WIDE SOLID LANE
R0
2
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
R0
2
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
STA 9+99.6A, 55.1' L
END DBL YEL
STA 9+99.8A, 71.2' L
END DBL YEL
STA 10+15.5A, 57.8' L
END BIKE LANE
STA 10+11.0A, 57.8' L
END BIKE LANE
STA 10+13.2A, 63.1' L
CENTER BIKE SYMBOL
STA 10+22.3A, 40.7' L
END CROSSWALK
STA 10+15.4A, 71.4' L
END BIKE LANE
STA 10+10.9A, 71.3' L
END BIKE LANE
STA 9+99.2A, 54.5' R
DBL YEL
STA 9+98.6A, 47.4' R
HYDRANT MARKER
STA 10+10.4A, 54.5' R
END WIDE SOLID LANE
STA 11+52.0A, 0.0' R
END YEL
RESTORATION AND CHANNELIZATION
GENERAL NOTES
RESTORATION KEYNOTES
PROPOSED RESTORATION LEGEND
CHANNELIZATION KEYNOTES
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
R
E
S
T
O
.
D
W
G
SHOWN
R01 57 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
RESTORATION PLAN VIEW
RE
S
T
O
R
A
T
I
O
N
,
P
A
V
E
M
E
N
T
M
A
R
K
I
N
G
S
,
A
N
D
CH
A
N
N
E
L
I
Z
A
T
I
O
N
P
L
A
N
S
0
1
NE
1
2
T
H
S
T
-
E
D
M
O
N
D
S
A
V
E
T
O
H
A
R
R
I
N
G
T
O
N
A
V
E
CHANNELIZATION AND PAVEMENT MARKINGS PLAN VIEW
1174 HARRINGTON AVE NE
TPN: 7227801675
METER SERVICE ON HARRINGTON
1177 HARRINGTON AVE NE
TPN: 7227801355
METER SERVICE ON HARRINGTON
2613 & 2615 NE 12TH ST
TPN: 7227801345
1" LATERAL 3/4" METER
ACCNT #003069
2607 & 2609 NE 12TH ST
TPN: 7227801340
1" LATERAL 3/4" METER
ACCNT #003067
JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
NA
TPN: 7227801860
METER SERVICE ON HARRINGTON
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
NE 12TH STREET
x
x x x x x x x x x x x x x x x x x x x
x
x
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
x
x
x
TEL TEL TEL TEL TEL TEL TEL TEL TEL
G
00
A
15
00
A
16
00
A
17
00
A
18
00
A
19
12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)12'' DI W (565)FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
MA
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
MA
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
MA
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
MA
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
STA 17+58.3A, 52.5' R
EDGE OF ROAD
STA 17+87.3A, 53.1' R
EDGE OF ROAD
STA 17+63.3A, 43.3' L
EDGE OF ROAD
STA 17+91.6A, 43.3' L
EDGE OF ROAD
R0
1
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
R0
1
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
R0
3
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
R0
3
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
R01 R02 R03 R04 R05 R06 R07 R08 R09
R1
0
1174 HARRINGTON AVE NE
TPN: 7227801675
METER SERVICE ON HARRINGTON
1177 HARRINGTON AVE NE
TPN: 7227801355
METER SERVICE ON HARRINGTON
2613 & 2615 NE 12TH ST
TPN: 7227801345
1" LATERAL 3/4" METER
ACCNT #003069
2607 & 2609 NE 12TH ST
TPN: 7227801340
1" LATERAL 3/4" METER
ACCNT #003067
JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
NA
TPN: 7227801860
METER SERVICE ON HARRINGTON
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
NE 12TH STREET
x
x x x x x x x x x x x x x x x x x x x
x
x
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
x
x
x
TEL TEL TEL TEL TEL TEL TEL TEL TEL
G
00
A
15
00
A
16
00
A
17
00
A
18
00
A
19
STA 16+47.0A, 0.0' L
END DBL YEL STA 17+51.2A, 20.2' L
END CROSSWALK
STA 17+62.3A, 20.8' L
END CROSSWALK
STA 17+62.8A, 31.8' L
END CROSSWALK
STA 17+63.6A, 38.4' L
END STOP BAR
STA 17+78.0A, 37.6' L
END STOP BAR
STA 17+78.5A, 37.6' L
DBL YEL
STA 17+93.5A, 33.3' L
END CROSSWALK
STA 17+93.2A, 22.3' L
END CROSSWALK
STA 18+04.2A, 22.3' L
END CROSSWALK
STA 17+47.4A, 20.7' R
END CROSSWALK
STA 17+58.4A, 20.6' R
END CROSSWALK
STA 17+58.1A, 31.6' R
END CROSSWALK
STA 17+75.6A, 37.1' R
END DBL YEL
STA 17+74.9A, 52.9' R
END DBL YEL
STA 18+09.3A, 0.0' R
END DBL YEL
STA 18+01.7A, 21.5' R
END CROSSWALK
STA 17+90.7A, 21.5' R
END CROSSWALK
STA 17+90.0A, 32.5' R
END CROSSWALK
STA 17+88.3A, 37.5' R
END STOP BAR
STA 17+76.1A, 37.1' R
END STOP BARSTA 17+76.1A, 43.9' R
HYDRANT MARKER
R0
1
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
R0
1
M
A
T
C
H
L
I
N
E
S
T
A
14
+
2
0
A
R0
3
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
R0
3
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
STA 18+09.2A, 20.6' L
END STOP BAR
STA 18+09.3A, 0.7' L
END STOP BAR
STA 14+30.2A, 0.8' L
HYDRANT MARKER
STA 16+32.0A, 0.0' L
END YEL
STA 17+42.4A, 0.0' R
END DBL YEL
STA 17+42.4A, 0.7' R
END STOP BAR
STA 17+42.4A, 19.8' R
END STOP BAR
STA 17+78.8A, 43.3' L
DBL YEL RESTORATION AND CHANNELIZATION
GENERAL NOTES
RESTORATION KEYNOTES
PROPOSED RESTORATION LEGEND
CHANNELIZATION KEYNOTES
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
R
E
S
T
O
.
D
W
G
SHOWN
R02 58 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
RESTORATION PLAN VIEW
RE
S
T
O
R
A
T
I
O
N
,
P
A
V
E
M
E
N
T
M
A
R
K
I
N
G
S
,
A
N
D
CH
A
N
N
E
L
I
Z
A
T
I
O
N
P
L
A
N
S
0
2
NE
1
2
T
H
S
T
-
E
D
M
O
N
D
S
A
V
E
T
O
H
A
R
R
I
N
G
T
O
N
A
V
E
CHANNELIZATION AND PAVEMENT MARKINGS PLAN VIEW
1175 HARRINGTON PL NE
TPN: 3122000000
2825 NE 12TH ST
TPN: 7227802045
2801 NE 12TH ST
TPN: 7227801680
1" METER ACCNT #003069
2810 NE 12TH ST
TPN: 7227801685
EXISTING 3/4" METER ACCNT
2902 NE 12TH ST
TPN: 7227802040
2908 NE 12TH ST
TPN: 7227801776
EXISTING 1-1/2" METER
ACCNT #3168-000
HA
R
R
I
N
G
T
O
N
P
L
N
E
NE 12TH STREET
x
x
x
x
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
00
A
19
00
A
20
00
A
21
00
A
22
00
A
23
12'' DI W (565)12'' DI W (565)12'' DI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
MA
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
MA
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
MA
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
MA
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
STA 22+89.9A, 44.4' R
EDGE OF ROAD
STA 23+13.5A, 48.6' R
EDGE OF ROAD
R0
2
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
R0
2
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
R0
4
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
R0
4
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
R01 R02 R03 R04 R05 R06 R07 R08 R09
R1
0
NE 12TH ST
1175 HARRINGTON PL NE
TPN: 3122000000
2825 NE 12TH ST
TPN: 7227802045
2801 NE 12TH ST
TPN: 7227801680
1" METER ACCNT #003069
2810 NE 12TH ST
TPN: 7227801685
EXISTING 3/4" METER ACCNT
2902 NE 12TH ST
TPN: 7227802040
2908 NE 12TH ST
TPN: 7227801776
EXISTING 1-1/2" METER
ACCNT #3168-000
HA
R
R
I
N
G
T
O
N
P
L
N
E
NE 12TH STREET
x
x
x
x
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
00
A
19
00
A
20
00
A
21
00
A
22
00
A
23
R0
2
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
R0
2
M
A
T
C
H
L
I
N
E
S
T
A
19
+
0
0
A
R0
4
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
R0
4
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
STA 21+41.9A, 0.8' R
HYDRANT MARKER
STA 19+33.0A, 0.0' L
END YEL
STA 22+93.5A, 31.5' R
END CROSSWALK
STA 22+92.2A, 41.4' R
END CROSSWALK
STA 23+13.1A, 35.7' R
END CROSSWALK
STA 23+11.8A, 45.6' R
END CROSSWALK
STA 19+18.0A, 0.0' R
END DBL YEL
RESTORATION AND CHANNELIZATION
GENERAL NOTES
RESTORATION KEYNOTES
PROPOSED RESTORATION LEGEND
CHANNELIZATION KEYNOTES
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
R
E
S
T
O
.
D
W
G
SHOWN
R03 59 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
RESTORATION PLAN VIEW
RE
S
T
O
R
A
T
I
O
N
,
P
A
V
E
M
E
N
T
M
A
R
K
I
N
G
S
,
A
N
D
CH
A
N
N
E
L
I
Z
A
T
I
O
N
P
L
A
N
S
0
3
NE
1
2
T
H
S
T
-
H
A
R
R
I
N
G
T
O
N
A
V
E
T
O
K
I
R
K
L
A
N
D
A
V
E
CHANNELIZATION AND PAVEMENT MARKINGS PLAN VIEW
FIRE STATION #12
1209 KIRKLAND AVE NE
TPN: 7227801450
4" DCDA W/ 3/4" METER
ACCNT #61583-001
1-1/2" IRR METER ACCNT
#61583-002
2" DOM METER ACCNT
#61583-000
1171 KIRKLAND AVE NE
TPN: 7227801406
975 HARRINGTON PL NE
TPN: 7227801405
3116 SUNSET BLVD NE
TPN: 0423059095
3002 NE SUNSET BLVD
TPN: 7227800285
KI
R
K
L
A
N
D
A
V
E
N
E
J
E
F
F
E
R
S
O
N
A
V
E
N
E
NE 12TH STREET
OH
P
x
x
x
00
A
24
00
A
25
00
A
26
00
A
27
00
A
28
12'' DI W (565)12'' DI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
MA
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
MA
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
MA
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
MA
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
NE 12TH STREET
STA 27+45.4A, 82.3' R
EDGE OF ROAD
STA 27+12.9A, 83.0' R
EDGE OF ROAD
STA 27+07.6A, 67.5' L
EDGE OF ROAD
STA 27+44.8A, 68.0' L
EDGE OF ROAD
R0
3
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
R0
3
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
R0
5
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
R0
5
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
R01 R02 R03 R04 R05 R06 R07 R08 R09
R1
0
NE 12TH ST
FIRE STATION #12
1209 KIRKLAND AVE NE
TPN: 7227801450
4" DCDA W/ 3/4" METER
ACCNT #61583-001
1-1/2" IRR METER ACCNT
#61583-002
2" DOM METER ACCNT
#61583-000
1171 KIRKLAND AVE NE
TPN: 7227801406
975 HARRINGTON PL NE
TPN: 7227801405
3116 SUNSET BLVD NE
TPN: 0423059095
3002 NE SUNSET BLVD
TPN: 7227800285
KI
R
K
L
A
N
D
A
V
E
N
E
JE
F
F
E
R
S
O
N
A
V
E
N
E
NE 12TH STREET
OH
P
x
x
x
00
A
24
00
A
25
00
A
26
00
A
27
00
A
28
NE 12TH STREET
STA 25+12.7A, 15.3' L
TRAFFIC ARROW
STA 24+96.2A, 0.0' L
END DBL YEL
STA 24+96.2A, 10.5' L
END WIDE SOLID LANE STA 25+78.2A, 15.8' L
TRAFFIC ARROW
STA 26+97.6A, 16.2' L
END CROSSWALK
STA 27+09.1A, 19.5' L
END CROSSWALK
STA 27+09.4A, 29.6' L
END CROSSWALK
STA 27+08.5A, 34.1' L
END STOP BAR
STA 27+28.5A, 34.0' L
END STOP BAR
STA 27+29.2A, 34.0' L
END SOLID YEL
STA 27+45.0A, 18.3' L
END CROSSWALK
STA 27+54.9A, 18.0' L
END CROSSWALK
STA 27+59.9A, 18.5' L
END STOP BAR
STA 28+22.2A, 6.9' R
TRAFFIC ARROW
STA 27+29.5A, 82.6' R
END DBL YEL
STA 27+43.7A, 40.2' R
END STOP BAR
STA 27+41.9A, 29.7' R
END CROSSWALK
STA 27+42.0A, 19.7' R
END CROSSWALK
STA 27+43.7A, 18.5' R
END CROSSWALK
STA 27+59.3A, 9.9' R
END WHITE LANE
STA 27+42.1A, 28.9' L
END CROSSWALK
R0
3
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
R0
3
M
A
T
C
H
L
I
N
E
S
T
A
23
+
8
0
A
R0
5
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
R0
5
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
STA 24+38.0A, 0.0' L
END YEL
STA 26+36.0A, 10.0' R
END WHITE LANE
STA 26+87.0A, 10.5' L
END WIDE SOLID LANE
STA 26+87.0A, 0.0' R
END DBL YEL
STA 27+87.5A, 1.0' L
HYDRANT MARKER
STA 27+59.0A, 0.2' L
END DBL YEL
STA 27+60.2A, 9.6' L
END WHITE SOLID LANE
STA 26+87.0A, 20.3' R
END STOP BAR
STA 26+92.0A, 20.2' R
END CROSSWALK
STA 27+02.0A, 20.2' R
END CROSSWALK
STA 27+14.4A, 39.1' R
END CROSSWALK
STA 27+26.1A, 40.4' R
END DBL YEL
STA 27+14.4A, 29.1' R
END CROSSWALK
STA 27+27.4A, 53.3' R
HYDRANT MARKER STA 27+26.9A, 40.4' R
END STOP BAR
STA 26+86.0A, 9.9' R
END WHITE LANE
STA 26+87.0A, 0.8' R
END STOP BAR
STA 27+53.7A, 18.9' R
END CROSSWALK
STA 27+41.8A, 18.7' L
END CROSSWALK
STA 27+29.3A, 67.8' L
END SOLID YEL
STA 27+07.6A, 16.2' L
END CROSSWALK
STA 27+59.0A, 1.0' L
END STOP BAR
STA 24+94.3A, 16.1' L
END CROSSWALK
STA 24+84.3A, 16.1' L
END CROSSWALK
STA 24+40.0A, 16.0' L
END CROSSWALK
STA 24+50.0A, 16.0' L
END CROSSWALK
STA 24+36.6A, 20.3' R
END CROSSWALK
STA 24+46.6A, 20.3' R
END CROSSWALK
STA 24+97.7A, 20.2' R
END CROSSWALK
STA 24+87.7A, 20.2' R
END CROSSWALK
STA 28+03.6A, 9.5' L
END WHITE SOLID LANE
RESTORATION AND CHANNELIZATION
GENERAL NOTES
RESTORATION KEYNOTES
PROPOSED RESTORATION LEGEND
CHANNELIZATION KEYNOTES
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
R
E
S
T
O
.
D
W
G
SHOWN
R04 60 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
RESTORATION PLAN VIEW
RE
S
T
O
R
A
T
I
O
N
,
P
A
V
E
M
E
N
T
M
A
R
K
I
N
G
S
,
A
N
D
CH
A
N
N
E
L
I
Z
A
T
I
O
N
P
L
A
N
S
0
4
NE
1
2
T
H
S
T
-
H
A
R
R
I
N
G
T
O
N
A
V
E
T
O
K
I
R
K
L
A
N
D
A
V
E
CHANNELIZATION AND PAVEMENT MARKINGS PLAN VIEW
NA
3011 NE SUNSET BLVD
TPN: 7227900019
METER SERVICE ON NENA
3123 NE SUNSET BLVD
TPN: 0423059155
1" METER ACCNT
#157203-000
1" IRR METER ACCNT
#57203
3116 NE SUNSET BLVD
TPN: 0423059095
3/4" IRR METER ACCNT
#19835-000
3002 NE SUNSET BLVD
TPN: 7227800285
METER SERVICE ON
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
00
A
29
00
A
30
00
A
31
00
A
32
12'' DI W (565)
16
'
'
D
I
W
(
4
3
5
)
12'' RJ DI W (565)12'' DI W (565)
16
'
'
D
I
W
(
4
3
5
)
FO FO FO FO FO FO FO FO FO FO FO FO FO
MA
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
MA
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
MA
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
MA
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
STA 29+56.3A, 34.9' R
EDGE OF ROAD
STA 29+50.0A, 41.4' R
EDGE OF ROAD
STA 29+37.7A, 45.7' R
EDGE OF ROAD
STA 30+96.2A, 73.4' L
EDGE OF ROAD
STA 30+47.8A, 105.1' L
EDGE OF ROAD
STA 30+04.8A, 66.5' R
EDGE OF ROAD
R0
4
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
R0
4
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
R0
6
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
R0
6
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
R01 R02 R03 R04 R05 R06 R07 R08 R09
R1
0
NA
TPN: 7227900018
3011 NE SUNSET BLVD
TPN: 7227900019
METER SERVICE ON NE
SUNSET BLVDNA
TPN: 722790UNKN
3123 NE SUNSET BLVD
TPN: 0423059155
1" METER ACCNT
#157203-000
1" IRR METER ACCNT
#57203
3116 NE SUNSET BLVD
TPN: 0423059095
3/4" IRR METER ACCNT
#19835-000
3002 NE SUNSET BLVD
TPN: 7227800285
METER SERVICE ON
NE SUNSET BLVD
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
00
A
29
00
A
30
00
A
31
00
A
32
STA 29+59.8A, 19.5' R
END CROSSWALK
STA 30+34.4A, 26.5' R
END CROSSWALK
STA 30+32.4A, 27.5' R
END CROSSWALK
STA 29+63.7A, 23.8' R
END CROSSWALK
STA 29+97.4A, 28.9' L
END CROSSWALK
STA 30+73.3A, 21.5' L
END CROSSWALK
STA 29+86.4A, 21.8' L
END CROSSWALK
STA 29+23.8A, 24.2' R
END CROSSWALK
STA 29+40.6A, 19.9' R
END STOP BAR
STA 29+42.5A, 22.1' R
END CROSSWALK
STA 29+46.9A, 19.2' R
END CROSSWALK
STA 29+33.2A, 34.2' R
END CROSSWALK
STA 29+46.3A, 32.8' R
END CROSSWALK
STA 29+71.7A, 19.3' L
END CROSSWALK
STA 29+63.6A, 9.3' L
END WHITE LANE
STA 30+05.5A, 39.5' L
END CROSSWALK
STA 30+08.7A, 44.4' L
END STOP BAR
STA 29+57.1A, 34.5' R
END CROSSWALK
STA 30+76.2A, 0.3' R
END DBL YEL
STA 29+52.7A, 1.0' R
END STOP BAR
STA 29+27.2A, 7.1' R
TRAFFIC ARROW
STA 29+45.8A, 10.2' R
END WIDE SOLID LANE
STA 29+62.2A, 48.5' R
END WHITE LANE
STA 29+67.6A, 40.1' R
END WHITE LANE
STA 29+76.3A, 47.9' R
END DBL YEL
STA 29+80.9A, 40.8' R
END DBL YEL
STA 29+85.8A, 54.2' R
END WIDE SOLID LANE
STA 29+81.6A, 40.8' R
END STOP BAR
STA 29+93.5A, 42.5' R
END WIDE SOLID LANE
STA 29+99.9A, 51.5' R
END WHITE LANE
STA 30+05.3A, 43.1' R
END WHITE LANE
STA 30+19.6A, 42.9' R
END STOP BAR
STA 30+23.0A, 38.0' R
END CROSSWALK
STA 30+52.6A, 21.5' R
END CROSSWALK
STA 30+68.5A, 11.1' R
END WHITE LANE
STA 31+02.5A, 7.1' L
TRAFFIC ARROW
STA 31+89.2A, 6.7' L
TRAFFIC ARROW
STA 31+38.3A, 0.1' L
HYDRANT MARKER
STA 30+96.1A, 24.1' L
END STOP BAR
STA 30+67.5A, 92.2' L
END WIDE SOLID LANE
STA 30+77.2A, 86.0' L
END DBL YEL
STA 30+88.4A, 83.6' L
END WHITE LANE
STA 30+68.6A, 71.4' L
HYDRANT MARKER
STA 30+61.3A, 41.6' L
END WHITE LANE
STA 30+71.0A, 36.1' L
END CROSSWALK
STA 30+73.9A, 35.6' L
END CROSSWALK
STA 30+92.2A, 27.3' L
END CROSSWALK
STA 30+23.3A, 44.6' L
END WHITE LANE
STA 30+36.0A, 44.0' L
END WIDE SOLID LANE
STA 30+47.7A, 42.3' L
END STOP BAR
STA 30+48.7A, 42.3' L
END DBL YEL
STA 30+48.7A, 53.3' L
TRAFFIC ARROW
STA 30+50.5A, 86.6' L
END WHITE LANE
STA 29+53.2A, 0.1' R
END DBL YEL
R0
4
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
R0
4
M
A
T
C
H
L
I
N
E
S
T
A
28
+
3
0
A
R0
6
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
R0
6
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
STA 29+19.3A, 10.2' R
END WIDE SOLID LANE
STA 28+33.6A, 9.5' L
END WHITE LANE
STA 30+88.4A, 11.1' L
END WIDE SOLID LANE
STA 30+76.9A, 0.4' L
END STOP BAR
STA 31+26.0A, 10.8' L
END WIDE SOLID LANE
STA 31+56.0A, 10.6' L
END WHITE LANE
STA 28+89.3A, 10.1' R
END WHITE LANE
STA 30+77.7A, 25.1' L
END CROSSWALK
STA 30+91.9A, 27.7' L
END CROSSWALK
STA 30+86.5A, 37.9' L
END CROSSWALK
STA 30+64.1A, 25.5' L
END CROSSWALK
RESTORATION AND CHANNELIZATION
GENERAL NOTES
RESTORATION KEYNOTES
PROPOSED RESTORATION LEGEND
CHANNELIZATION KEYNOTES
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
R
E
S
T
O
.
D
W
G
SHOWN
R05 61 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
RESTORATION PLAN VIEW
RE
S
T
O
R
A
T
I
O
N
,
P
A
V
E
M
E
N
T
M
A
R
K
I
N
G
S
,
A
N
D
CH
A
N
N
E
L
I
Z
A
T
I
O
N
P
L
A
N
S
0
5
NE
1
2
T
H
S
T
-
K
I
R
K
L
A
N
D
A
V
E
T
O
M
O
N
R
O
E
A
V
E
CHANNELIZATION AND PAVEMENT MARKINGS PLAN VIEW
1170 MONROE AVE NE
TPN: 0923059170
3233 NE 12TH ST
TPN: 7801300000
METER SERVICES ON
LYNNWOODTPN: 7227900018
3316 NE 12TH ST
TPN: 7736100015
3232 NE 12TH ST
TPN: 0423059316
3224 NE 12TH ST
TPN: 0423059169
3/4" METER ACCNT
#7720-000
3218 NE 12TH ST
TPN: 0423059182
1-1/2" METER
ACCNT #17721-00
LY
N
N
W
O
O
D
A
V
E
N
E
M
O
N
R
O
E
A
V
E
N
E
NE 12TH ST
OHP OHP
OH
P
OH
P
OH
P
OH
P
O
H
P
OHP OHP OHP OHP OHP
OHP
O
H
P
O
H
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
x
x
x
x
x
xxxxxxxxxxxx
x
x
x
x
xxxxxxxx
x x x
00
A
33
00
A
34
00
A
35
00
A
36
12'' DI W (565)12'' DI W (565)12'' DI W (565)
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
MA
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
MA
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
MA
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
MA
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
STA 33+27.8A, 80.1' R
EDGE OF ROAD
STA 34+16.2A, 16.2' L
EDGE OF ROAD
STA 34+16.2A, 31.5' L
EDGE OF ROAD
STA 34+22.2A, 31.5' L
EDGE OF ROAD
STA 34+22.2A, 16.2' L
EDGE OF ROAD
STA 35+23.7A, 59.2' R
EDGE OF ROAD
STA 32+92.0A, 81.1' R
EDGE OF ROAD
STA 35+68.1A, 58.5' R
EDGE OF ROAD
R0
5
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
R0
5
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
R0
7
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
R0
7
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
R01 R02 R03 R04 R05 R06 R07 R08 R09
R1
0
1170 MONROE AVE NE
TPN: 0923059170
3233 NE 12TH ST
TPN: 7801300000
METER SERVICES ON
LYNNWOODTPN: 7227900018
3316 NE 12TH ST
TPN: 7736100015
3232 NE 12TH ST
TPN: 0423059316
3224 NE 12TH ST
TPN: 0423059169
3/4" METER ACCNT
#7720-000
3218 NE 12TH ST
TPN: 0423059182
1-1/2" METER
ACCNT #17721-00
LY
N
N
W
O
O
D
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
NE 12TH ST
OHP OHP
OH
P
OH
P
OH
P
OH
P
O
H
P
OHP OHP OHP OHP OHP
OHP
O
H
P
O
H
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
x
x
x
x
x
xxxxxxxxxxxx
x
x
x
x
xxxxxxxx
x x x
00
A
33
00
A
34
00
A
35
00
A
36
STA 33+08.4A, 54.9' R
HYDRANT MARKER
STA 33+26.8A, 45.2' R
END STOP BAR
STA 33+09.7A, 45.6' R
END STOP BAR
STA 33+16.8A, 20.7' L
END EDGE LINE
STA 35+21.7A, 27.7' R
END CROSSWALK
STA 35+24.1A, 37.4' R
END CROSSWALK
STA 35+45.5A, 36.7' R
END DBL YEL
STA 35+46.5A, 59.0' R
END DBL YEL
STA 35+57.5A, 58.8' R
END WIDE SOLID LANE
STA 35+57.6A, 42.3' R
HYDRANT MARKER
STA 35+56.5A, 37.5' R
END WIDE SOLID LANE
STA 35+46.3A, 36.7' R
END STOP BAR
STA 35+67.7A, 36.3' R
END STOP BAR
STA 34+91.9A, 16.9' R
TRAFFIC ARROW
STA 35+17.4A, 12.1' R
END WIDE SOLID LANE
STA 35+67.5A, 30.8' R
END CROSSWALKSTA 34+51.9A, 12.0' R
END WIDE SOLID LANE
R0
5
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
R0
5
M
A
T
C
H
L
I
N
E
S
T
A
32
+
4
0
A
R0
7
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
R0
7
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
STA 32+86.0A, 9.6' L
END WHITE LANE
STA 32+85.9A, 1.5' R
END DBL YEL
STA 32+53.5A, 12.2' R
END WHITE LANE
STA 33+31.9A, 11.9' R
END WIDE BRKN LANE
STA 34+20.3A, 16.9' R
TRAFFIC ARROW
STA 35+67.3A, 20.8' R
END CROSSWALK
STA 34+36.9A, 12.0' R
END WIDE BRKN LANE
STA 33+31.8A, 1.5' R
END DBL YEL
STA 35+17.4A, 1.6' R
END DBL YEL
STA 35+64.5A, 1.3' R
END DBL YEL
STA 32+85.9A, 12.4' R
END WIDE SOLID LANE
STA 32+68.5A, 12.3' R
END WIDE SOLID LANE
RESTORATION AND CHANNELIZATION
GENERAL NOTES
PROPOSED RESTORATION LEGEND
RESTORATION KEYNOTES
CHANNELIZATION KEYNOTES
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
R
E
S
T
O
.
D
W
G
SHOWN
R06 62 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
RESTORATION PLAN VIEW
RE
S
T
O
R
A
T
I
O
N
,
P
A
V
E
M
E
N
T
M
A
R
K
I
N
G
S
,
A
N
D
CH
A
N
N
E
L
I
Z
A
T
I
O
N
P
L
A
N
S
0
6
NE
1
2
T
H
S
T
-
K
I
R
K
L
A
N
D
A
V
E
T
O
M
O
N
R
O
E
A
V
E
CHANNELIZATION AND PAVEMENT MARKINGS PLAN VIEW
x x x x x x x
x
x
x
x
x x x x x x x x x
x
x
x x
x
x
x x x x x x x x x
x
x
x
T
E
L
T
E
L
OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
OHP
OHP
OHP OHP OHP
x
x
x
x
x
xxxxxx
x
x
x
x
TELTELTELTELTEL
TE
L
TE
L
TE
L
x x x x x x x x x x x x
x x x
x
x x x x x
TEL
TE
L
3323 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#59301-000
3317 NE 12TH ST
TPN: 0923059162
3/4" METER ACCNT
#24137-000
1204 MONROE AVE NE
TPN: 7736100055
3/4" METER ACCNT
#7801-000
3316 NE 12TH ST
TPN: 7736100015
MO
N
R
O
E
A
V
E
N
E
NE 12TH ST
OHP OHP OHP
O
H
P
O
H
P
OH
P
OH
P
OH
P
O
H
P
O
H
P
O
H
P
O
H
P
O
H
P
OHP
OHP
OHP OHP OHP OHP
OH
P
x x x x x x x
x
x x
x
x
x
x x x x
x
TELTELTELTEL
T
E
L
TELTELTEL
T
E
L
PP
TEL
PP
3401 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#44306-000
3410 NE 12TH ST
TPN: 0423059186
3327 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#7742-000
00
A
37
00
A
38
00
A
39
00
A
40
00B10
00B11
12'' DI W (565)
12'' DI W (565)
12'' DI W (565)
16'' DI W
FO
FO FO FO FO FO FO FO
MA
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
MA
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
STA 37+07.4A, 47.4' L
EDGE OF ROAD
STA 37+36.2A, 48.0' L
EDGE OF ROAD
STA 38+50.3A, 22.4' L
EDGE OF ROAD
STA 38+67.0A, 23.0' L
EDGE OF ROAD
STA 37+94.0A, 13.6' R
EDGE OF ROAD
STA 37+94.1A, 16.6' R
EDGE OF ROAD
STA 38+55.1A, 13.6' R
EDGE OF ROAD
STA 38+55.4A, 30.2' R
EDGE OF ROAD
STA 38+63.7A, 30.2' R
EDGE OF ROAD
STA 38+75.7A, 13.6' R
EDGE OF ROAD
STA 38+72.8A, 13.6' R
EDGE OF ROAD
STA 39+70.6A, 13.7' R
EDGE OF ROAD
STA 39+38.8A, 13.7' R
EDGE OF ROAD
STA 39+32.8A, 13.7' R
EDGE OF ROAD
STA 39+72.8A, 62.1' L
EDGE OF ROAD
STA 39+49.4A, 61.4' L
EDGE OF ROAD
STA 38+63.4A, 13.6' R
EDGE OF ROAD
STA 39+57.5A, 13.7' R
EDGE OF ROAD
R0
8
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
R0
8
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
R0
6
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
R0
6
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
R01 R02 R03 R04 R05 R06 R07 R08 R09
R1
0
x x x x x x x
x
x
x
x
x x x x x x x x x
x
x
x x
x
x
x x x x x x x x x
x
x
x
T
E
L
T
E
L
OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
OHP
OHP
OHP OHP OHP
x
x
x
x
x
xxxxxx
x
x
x
x
TELTELTELTELTEL
TE
L
TE
L
TE
L
x x x x x x x x x x x x
x x x
x
x x x x x
TEL
TE
L
3323 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#59301-000
3317 NE 12TH ST
TPN: 0923059162
3/4" METER ACCNT
#24137-000
1204 MONROE AVE NE
TPN: 7736100055
3/4" METER ACCNT
#7801-000
3316 NE 12TH ST
TPN: 7736100015
MO
N
R
O
E
A
V
E
N
E
NE 12TH ST
OHP OHP OHP
O
H
P
O
H
P
OH
P
OH
P
OH
P
O
H
P
O
H
P
O
H
P
O
H
P
O
H
P
OHP
OHP
OHP OHP OHP OHP
OH
P
x x x x x x x
x
x x
x
x
x
x x x x
x
TELTELTELTEL
T
E
L
TELTELTEL
T
E
L
PP
TEL
PP
3401 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#44306-000
3410 NE 12TH ST
TPN: 0423059186
3327 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#7742-000
00
A
37
00
A
38
00
A
39
00
A
40
00B10
STA 36+96.2A, 13.4' L
END EDGE LINE
STA 37+03.8A, 26.1' L
END STOP BAR
STA 37+22.4A, 26.2' L
END STOP BAR
STA 37+46.1A, 13.0' L
END EDGE LINE
STA 39+36.8A, 1.8' L
HYDRANT MARKER
R0
8
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
R0
8
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
R0
6
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
R0
6
M
A
T
C
H
L
I
N
E
S
T
A
36
+
4
0
A
STA 39+48.3A, 0.7' L
DBL YEL
STA 37+90.0A, 11.0' R
END EDGE LINE
STA 36+96.8A, 0.2' R
END DBL YEL STA 37+46.0A, 0.0' L
END DBL YEL
RESTORATION AND CHANNELIZATION
GENERAL NOTES
RESTORATION KEYNOTES
PROPOSED RESTORATION LEGEND
CHANNELIZATION KEYNOTES
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
R
E
S
T
O
.
D
W
G
SHOWN
R07 63 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
RESTORATION PLAN VIEW
RE
S
T
O
R
A
T
I
O
N
,
P
A
V
E
M
E
N
T
M
A
R
K
I
N
G
S
,
A
N
D
CH
A
N
N
E
L
I
Z
A
T
I
O
N
P
L
A
N
S
0
7
NE
1
2
T
H
S
T
-
M
O
N
R
O
E
A
V
E
T
O
O
L
Y
M
P
I
A
A
V
E
CHANNELIZATION AND PAVEMENT MARKINGS PLAN VIEW
x
x x x x x x x x x x x x x x x x x x x x x x
x
x
x
x
x
xxxxxxxxxx
TEL
TEL
TE
L
TE
L
OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
x
x
x
x
x
x
x
x
x
x
x
x
OHP OHP OHP OHP OHP OHP OHP OHP
x
x
x
x
x
x
x
x x x x x x x x x x x x x x x x x x x x x x x x x x
OHP
NA
TP
N
:
0
4
2
3
0
5
9
2
5
1
OL
Y
M
P
I
A
A
V
E
N
E
NE 12TH ST
TELTEL
TELTEL
3417 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#54364-000
3501 NE 12TH ST
TPN: 8062900035
3/4" METER ACCNT
#7747-000
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES ON PIERCE
x x
00
A
41
00
A
42
00
A
43
12'' DI W (565)
12'' DI W (565)
16'' DI W
12'' DI W (565)
STA 42+35.5A, 21.7' R
EDGE OF ROAD
STA 42+35.4A, 13.9' R
EDGE OF ROAD
STA 42+14.4A, 53.3' R
EDGE OF ROAD
STA 41+69.6A, 13.9' R
EDGE OF ROAD
STA 41+80.5A, 44.1' L
EDGE OF ROAD
STA 41+58.4A, 42.2' L
EDGE OF ROAD
STA 41+04.9A, 13.8' R
EDGE OF ROAD
STA 40+96.3A, 13.8' R
EDGE OF ROAD
STA 41+69.6A, 21.9' R
EDGE OF ROAD
STA 41+82.8A, 53.8' R
EDGE OF ROADR0
7
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
R0
7
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
R0
9
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
R0
8
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
R0
9
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
R0
8
M
A
T
C
H
L
I
N
E
S
T
A
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
R01 R02 R03 R04 R05 R06 R07 R08 R09
R1
0
x
x x x x x x x x x x x x x x x x x x x x x x
x
x
x
x
x
xxxxxxx
xx x
TEL
TEL
TE
L
TE
L
OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
x
x
x
x
x
x
x
x
x
x
x
x
OHP OHP OHP OHP OHP OHP OHP OHP
x
x
x
x
x
x
x
x x x x x x x x x x x x x x x x x x x x x x x x x x
OHP
NA
TP
N
:
0
4
2
3
0
5
9
2
5
1
OL
Y
M
P
I
A
A
V
E
N
E
NE 12TH ST
TELTEL
TELTEL
3417 NE 12TH ST
TPN: 0923059183
3/4" METER ACCNT
#54364-000
3501 NE 12TH ST
TPN: 8062900035
3/4" METER ACCNT
#7747-000
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES ON PIERCE
x x
00
A
41
00
A
42
00
A
43
STA 42+31.3A, 12.0' R
END EDGE LINE
STA 41+98.7A, 30.3' R
END STOP BAR
STA 42+12.8A, 30.0' R
END STOP BAR
STA 41+63.0A, 11.5' R
END EDGE LINE
R0
7
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
R0
7
M
A
T
C
H
L
I
N
E
S
T
A
40
+
2
0
A
R0
9
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
R0
8
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
R0
9
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
R0
8
M
A
T
C
H
L
I
N
E
S
T
A
STA 41+63.3A, 0.0' R
END DBL YEL STA 42+21.1A, 0.0' R
END YEL
RESTORATION AND CHANNELIZATION
GENERAL NOTES
RESTORATION KEYNOTES
PROPOSED RESTORATION LEGEND
CHANNELIZATION KEYNOTES
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
R
E
S
T
O
.
D
W
G
SHOWN
R08 64 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
RESTORATION PLAN VIEW
RE
S
T
O
R
A
T
I
O
N
,
P
A
V
E
M
E
N
T
M
A
R
K
I
N
G
S
,
A
N
D
CH
A
N
N
E
L
I
Z
A
T
I
O
N
P
L
A
N
S
0
8
NE
1
2
T
H
S
T
-
M
O
N
R
O
E
A
V
E
T
O
O
L
Y
M
P
I
A
A
V
E
CHANNELIZATION AND PAVEMENT MARKINGS PLAN VIEW
xxxxxxx
OH
P
OH
P
x
x
x
OHP OHP
PI
E
R
C
E
P
L
N
E
3515 NE 12TH ST
TPN: 8062900040
3/4" METER ACCNT
#46676-000
OHP OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OHP OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
x
x
OH
P
OH
P
OH
P
OH
P
x
8'' AC W (565)8'' AC W (565)8'' AC W (565)
OH
P
OH
P
OH
P
OH
P
OH
P
O
H
P
O
H
P
OHP OHP
1204 PIERCE PL NE
TPN:0911500160
METER SERVICES ON PIERCE
1203 QUEEN AVE NE
TPN:0911500105
METER SERVICES ON QUEEN
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES
ON QUEEN
1159 PIERCE AVE NE
TPN: 8062900005
3607 NE 12TH ST
TPN: 0923059205
3/4" METER ACCNT
#45388-000
3613 NE 12TH ST
TPN: 0923059252
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
xxxxxxx
x x x xxxxx
xxxxxxxx
x
xxxxxxxxxxxxxxxxxx
x x x x x
QU
E
E
N
A
V
E
N
E
NE 12TH ST
PI
E
R
C
E
A
V
E
N
E
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES
ON PIERCE
00
A
44
00
A
45
00
A
46
00
A
4712'' DI W (565)
STA 44+98.2A, 14.5' R
EDGE OF ROAD
STA 44+98.1A, 26.4' R
EDGE OF ROAD
STA 45+03.4A, 32.3' R
EDGE OF ROAD
STA 45+29.3A, 32.1' R
EDGE OF ROAD
STA 45+38.1A, 14.6' R
EDGE OF ROAD
STA 46+67.0A, 15.0' R
EDGE OF ROAD
STA 46+67.1A, 13.6' L
EDGE OF ROAD
STA 45+38.2A, 23.7' R
EDGE OF ROAD
R0
8
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
R0
8
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
R01 R02 R03 R04 R05 R06 R07 R08 R09
R1
0
xxxxxxx
OH
P
OH
P
x
x
x
OHP OHP
PI
E
R
C
E
P
L
N
E
3515 NE 12TH ST
TPN: 8062900040
3/4" METER ACCNT
#46676-000
OHP OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OHP OHP OHP OHP OHP OHP
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
x
x
OH
P
OH
P
OH
P
OH
P
x
8'' AC W (565)8'' AC W (565)8'' AC W (565)
OH
P
OH
P
OH
P
OH
P
OH
P
O
H
P
O
H
P
OHP OHP
1204 PIERCE PL NE
TPN:0911500160
METER SERVICES ON PIERCE
1203 QUEEN AVE NE
TPN:0911500105
METER SERVICES ON QUEEN
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES
ON QUEEN
1159 PIERCE AVE NE
TPN: 8062900005
3607 NE 12TH ST
TPN: 0923059205
3/4" METER ACCNT
#45388-000
3613 NE 12TH ST
TPN: 0923059252
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
6
A
C
W
(
5
6
5
)
xxxxxxx
x x x xxxxx
xxxxxxxx
x
xxxxxxxxxxxxxxxxxx
x x x x x
QU
E
E
N
A
V
E
N
E
NE 12TH ST
PI
E
R
C
E
A
V
E
N
E
1203 PIERCE PL NE
TPN: 0911500100
METER SERVICES
ON PIERCE
00
A
44
00
A
45
00
A
46
00
A
47
STA 45+30.1A, 12.8' R
END EDGE LINE
STA 45+26.8A, 29.9' R
END STOP BAR
STA 45+17.0A, 29.6' R
END STOP BAR
STA 43+95.2A, 12.4' L
END EDGE LINE
STA 44+97.1A, 12.8' R
END EDGE LINE
STA 44+97.2A, 1.7' R
HYDRANT MARKER
R0
8
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
R0
8
M
A
T
C
H
L
I
N
E
S
T
A
43
+
1
0
A
STA 43+50.1A, 12.4' L
END EDGE LINE
STA 46+67.0A, 13.2' R
END EDGE LINE
STA 46+67.1A, 10.6' L
END EDGE LINE
STA 43+95.2A, 0.0'
END YEL
STA 45+00.2A, 0.0'
END YEL
STA 45+30.1A, 0.0' R
END YEL
STA 46+60.1A, 0.0' R
END YEL
STA 43+51.1A, 0.0' R
END YEL
RESTORATION AND CHANNELIZATION
GENERAL NOTES
RESTORATION KEYNOTES
PROPOSED RESTORATION LEGEND
CHANNELIZATION KEYNOTES
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
R
E
S
T
O
.
D
W
G
SHOWN
R09 65 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
RESTORATION PLAN VIEW
RE
S
T
O
R
A
T
I
O
N
,
P
A
V
E
M
E
N
T
M
A
R
K
I
N
G
S
,
A
N
D
CH
A
N
N
E
L
I
Z
A
T
I
O
N
P
L
A
N
S
0
9
NE
1
2
T
H
S
T
-
O
L
Y
M
P
I
A
A
V
E
T
O
Q
U
E
E
N
A
V
E
CHANNELIZATION AND PAVEMENT MARKINGS PLAN VIEW
1409 & 1417 MONROE AVE NE
TPN: 0423059104
3/4" METER ACCNT #7730-000
1408 MONROE AVE NE
TPN: 7736100030
3/4" METER ACCNT
#7809-000
1400 MONROE AVE NE
TPN: 7736100035
3/4" METER ACCNT
#7808-000
1324 MONROE AVE NE
TPN: 7736100036
3/4" METER ACCNT
#7807-000
1333 MONROE AVE NE
TPN: 0423059111
3/4" METER ACCNT
#57275-000
1401 MONROE AVE NE
TPN: 0423059126
3/4" METER ACCNT
#28758-000
1416 MONROE AVE NE
TPN: 7736100020
NA
TP
N
:
0
4
2
3
0
5
T
R
C
T
NA
TPN: 7736100025
N
E
S
U
N
S
E
T
B
L
V
D
MONROE AVE. NE
OHP OHP OHP OHP OHP
OH
P
OHP
O
H
P
O
H
P
O
H
P
O
H
P
OH
P
OHP
OH
P
OH
P
OH
P
OH
P
OH
P
OH
P
x
x
xxxxxxxxxx
x
xx
x
x
xxx
x
x
x
x
13
1
5
M
O
N
R
O
E
A
V
E
N
E
TP
N
:
7
7
3
6
1
0
0
0
0
3
00
B
15
00
B
16
00
B
17
00
B
18
00
B
19
8'' DI W (565)8'' DI W (565)
STA 14+72.3B, 13.0' R
EDGE OF ROAD
STA 15+20.8B, 30.0' L
EDGE OF ROAD
STA 14+72.6B, 17.2' L
EDGE OF ROAD
STA 14+80.5B, 30.0' L
EDGE OF ROAD
STA 16+51.4B, 22.3' L
EDGE OF ROAD
STA 16+40.8B, 22.4' L
EDGE OF ROAD
STA 17+45.2B, 14.8' L
EDGE OF ROAD
STA 17+45.1B, 13.0' R
EDGE OF ROAD
STA 16+09.4B, 30.0' L
EDGE OF ROAD
STA 16+15.4B, 14.7' L
EDGE OF ROAD
STA 16+15.4B, 30.0' L
EDGE OF ROAD STA 16+36.0B, 14.6' L
EDGE OF ROAD
STA 16+56.3B, 14.6' L
EDGE OF ROAD
STA 15+27.2B, 15.5' L
EDGE OF ROAD
STA 16+09.4B, 14.7' L
EDGE OF ROAD
MO
N
R
O
E
A
V
E
N
E
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
ED
M
O
N
D
S
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
OL
Y
M
P
I
A
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
R01 R02 R03 R04 R05 R06 R07 R08 R09
R1
0
RESTORATION AND CHANNELIZATION
GENERAL NOTES
RESTORATION KEYNOTES
PROPOSED RESTORATION LEGEND
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
KEY PLAN
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
R
E
S
T
O
.
D
W
G
SHOWN
R10 66 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
RESTORATION PLAN VIEW
RE
S
T
O
R
A
T
I
O
N
,
P
A
V
E
M
E
N
T
M
A
R
K
I
N
G
S
,
A
N
D
CH
A
N
N
E
L
I
Z
A
T
I
O
N
P
L
A
N
S
1
0
MO
N
R
O
E
A
V
E
-
N
E
1
2
T
H
S
T
T
O
S
U
N
S
E
T
A
V
E
T1
TYP.
4. WHEN POOR QUALITY FOUNDATION IS ENCOUNTERED
BELOW THE BEDDING MATERIAL, OR WHEN DIRECTED BY
THE ENGINEER, OVER-EXCAVATE AND PROVIDE AND
INSTALL CSBC, MEETING THE REQUIREMENTS OF STD.
SPEC. 9-03.9(2). THE USE OF GEOTEXTILE SEPARATION
FABRIC MAY ALSO BE REQUIRED BY THE ENGINEER TO
STABILIZE THE BASE.
5. RECYCLED MATERIAL AS DEFINED BY WSDOT STD. SPEC.
9-03.21 SHALL NOT BE ALLOWED IN ANY PIPE ZONE
BEDDING OR TRENCH BACKFILL.
TRENCH BACKFILL MATERIALS AND CONDITIONS
1. BEDDING AND BACKFILL SHALL BE COMPACTED TO 95% OF MAXIMUM DENSITY WITHIN TRAVELED ROADWAYS AND
SHOULDERS. CONTRACTOR SHALL ADD WATER AS NECESSARY TO OBTAIN OPTIMUM MOISTURE CONTENT AS DETERMINED
BY COMPACTION TESTING PROCTOR.
2.ALL TRENCHING AND SHORING TO BE DONE IN ACCORDANCE WITH OSHA AND WISHA STANDARDS. CONTRACTOR SHALL
BE RESPONSIBLE FOR TRENCH SAFETY AND EXCAVATION AS SOIL CONDITIONS CHANGE IN THE FIELD.
PIPE COVER
DEPTH OF COVER MEASURED FROM FINISHED GRADE TO TOP OF
WATER MAIN.
1.MIN. 36" FOR WATER MAIN 10" DIAMETER OR SMALLER
2.MIN. 48" FOR WATER MAIN 12" DIAMETER OR LARGER
3.MIN. 24" FOR STORM DRAIN PIPE
NOTES:
1.DEEPER EXCAVATION MAY BE REQUIRED DUE TO
LOCALIZED BREAKS IN GRADE OR TO INSTALL THE
PROPOSED PIPE UNDER EXISTING UTILITIES AND WILL BE
INCIDENTAL TO THE CONTRACT.
2.WHERE THE PROFILE OF THE PIPELINE AND GROUND
SURFACE IS SHOWN ON THE PLANS, THE PIPELINE SHALL
BE CONSTRUCTED TO THE ELEVATIONS SHOWN
REGARDLESS OF DEPTH.
3.THE LOCATION OF THE BLOW-OFF (LOW POINTS) AND AIR
VALVE (HIGH POINTS) ASSEMBLIES ARE SHOWN ON THE
PLANS. UNLESS OTHERWISE NOTED, THE CONTRACTOR
SHALL BE RESPONSIBLE FOR MAINTAINING A
CONTINUOUSLY FALLING PIPE SLOPE. THE CONTRACTOR
SHALL NOT CREATE LOCAL HIGH OR LOW POINTS EXCEPT
WHERE SPECIFICALLY DETAILED IN THESE PLANS OR
DIRECTED BY THE OWNER'S FIELD REPRESENTATIVE.
CREATION OF A LOCAL HIGH OR LOW POINT WOULD
MATERIALLY AFFECT THE OPERATION OF THE PROPOSED
SYSTEM AND WILL THEREFORE REQUIRE THAT THE PIPELINE
BE REMOVED AND REINSTALLED WITHOUT A LOCAL HIGH
OR LOW POINT AT THE CONTRACTOR'S EXPENSE.
UNDISTURBED
NATIVE SOIL
PROPOSED
PAVEMENT
EXISTING PAVEMENTUNDISTURBED
NATIVE SOIL
COMPACTED
TRENCH BACKFILL
IMPORTED
TOPSOIL MIX COMPACTED CSTC
EXISTING GRAVEL/BALLAST
PROPOSED
PAVEMENT
EXISTING PAVEMENT
COMPACTED FOUNDATION
GRAVEL OR CSBC
PROPOSED
LANDSCAPING
EXISTING
LANDSCAPING
TRENCH NOTES
TRENCH AND SURFACE RESTORATION LEGEND
EXISTING GRADE
TRENCH WIDTH PER SPECIAL
PROVISION SECTION 7-08.3
PIPE SIZE AND
MATERIAL AS
SPECIFIED
12" MIN.
6" MIN.
EXCAVATION LIMITS
DEPTH VARIES PER
PLAN, PROFILE, AND
PIPE COVER NOTES ON
THIS SHEET
TYPICAL LONGITUDINAL WATER MAIN AND STORM PIPE TRENCH DETAIL WITH OVERLAY
NOT TO SCALE
12" MIN.
3" MIN ALL SIDES
8"
9"
SAND
36" MIN.6" MIN.
6" MIN.
6" MIN.6" MIN.
SEE NOTE 2
SEE NOTE 1
CROSSING SANITARY OR STORM
SEWER
ELEVATIONSECTION
CLSM ENCASEMENT DETAIL
NOT TO SCALE
1.THE NEW CROSSING SANITARY OR STORM SEWER SHALL BE ENCASED IF THE VERTICAL SEPARATION IS AS FOLLOWS:
A)SANITARY OR STORM SEWER LINE LOCATED LESS THAN 6" OF CLEARANCE BELOW EXISTING POTABLE WATER MAIN; OR
B)NEW SANITARY OR STORM SEWER LINE LOCATED LESS THAN 18" ABOVE EXISTING POTABLE WATER MAIN. ALTERNATIVELY, THE EXISTING WATER MAIN MAY BE
ENCASED WITH OWNER APPROVAL.
2.NEW WATER MAIN SHALL BE ENCASED IF THE WATER MAIN IS CROSSING BELOW EXISTING SANITARY OR STORM SEWER WITH LESS THAN 18" OF CLEARANCE. CLSM
ENCASEMENT MIN. 10' EITHER SIDE OF PIPE CROSSING.
3.CLSM ENCASEMENT SHALL BE AT THE DISCRETION OF THE CITY OF RENTON.
4.CLSM MIX TO BE FLOWABLE, NON-SEGREGATING, EXCAVATABLE, AND CONFORM TO THE FOLLOWING:
·MIX TO CONTAIN NO FLY ASH OR CHLORIDES WHEN IN CONTACT WITH FERROUS METAL PIPE SUCH AS WELDED STEEL PIPE, DUCTILE IRON PIPE OR CAST IRON PIPE.
·MAXIMUM COMPRESSIVE STRENGTH: 150 PSI.
·MINIMUM 28-DAY COMPRESSIVE STRENGTH: 50 PSI.
·FLOWABILITY: 8 INCH +/- 1 INCH SPREAD DIAMETER USING A THREE (3) INCH DIAMETER BY SIX (6) INCH LONG CYLINDER PER ASTM D 6103 – STANDARD TEST
METHOD FOR FLOW CONSISTENCY OF CLSM.
PROTECT CLSM FOR AT LEAST 24 HOURS AFTER PLACEMENT OR AS NECESSARY TO PREVENT DISPLACEMENT BY CONSTRUCTION ACTIVITIES OR TRAFFIC. CLSM PLACING
MAY BE STARTED IF WEATHER CONDITIONS ARE FAVORABLE, WHEN THE TEMPERATURE IS A MINIMUM OF 34 DEGREES FAHRENHEIT AND RISING. AT THE TIME OF
PLACEMENT, CLSM MUST HAVE A TEMPERATURE OF AT LEAST 40 DEGREES FAHRENHEIT. PLACING SHALL STOP WHEN THE TEMPERATURE IS 38 DEGREES FAHRENHEIT OR
LESS AND FALLING. CLSM SHALL NOT BE PLACED ON FROZEN GROUND.
CURE CLSM FOR THE FOLLOWING MINIMUM DURATIONS PRIOR TO PLACEMENT OF ANY MATERIAL DIRECTLY OVER THE CLSM. IF TRAFFIC MUST BE RESTORED PRIOR TO
THE DURATION STATED, OR THE OPEN EXCAVATION MUST BE CLOSED FOR SAFETY, SPAN THE EXCAVATION WITH TEMPORARY PLATING APPROPRIATE FOR THE
ANTICIPATED LOADING. COLD WEATHER MAY REQUIRE MORE TIME. CURING ACCELERATORS MAY BE USED TO REDUCE THESE TIMES IF APPROVED BY THE OWNER.
·PIPE ENCASEMENT: 4 HOURS.
·NON-TRAFFIC: 24 HOURS.
·VEHICULAR TRAFFIC UNDER 5,000 LBS PER AXLE: 48 HOURS
·VEHICULAR TRAFFIC OVER 5,000 LBS PER AXLE: 72 HOURS
T4
TYP.
TRENCH CLEARANCES
NOT TO SCALE
*WHERE MIN. CLEARANCE BETWEEN POTABLE WATER
AND SEWER CAN NOT BE ACHIEVED, THE SEWER
SHALL BE CONCRETE ENCASED PER CITY STANDARDS.
CONCRETE ENCASEMENT SHALL EXTEND MIN. 10' EACH
WAY FROM THE POINT OF THE UTILITY CROSSING.
WHERE WATER AND SEWER ARE INSTALLED PARALLEL,
CONCRETE ENCASEMENT SHALL BE FULL LENGTH.
SANITARY SEWER CROSSING
18" MIN* ABOVE
SANITARY SEWER
PARALLEL
10' MIN.* FROM
OTHER UTILITIES
36" MIN. FROM
SS1
D04
WHERE 3" SCH. 80 PVC CONDUIT IS INSTALLED,
EXPAND EXCAVATION LIMITS BY 12" MIN. AND
PROVIDE JOINT UTILITY TRENCH
T5
TYP.
EXISTING GRADE
UTILITY PROTECTION DETAIL
NOT TO SCALE
SEE NOTE 5UTILITY PROTECTION NOTES:
1.PROVIDE TRENCH SHORING AS REQUIRED AND APPROPRIATE TO EXCAVATE AND PROTECT
ADJACENT UTILITIES. CONFIRM TYPE, SIZE, AND MATERIAL OF ADJACENT UTILITIES, AS WELL AS
BEDDING AND BACKFILL MATERIAL, AND PROVIDE APPROPRIATE PROTECTION MEASURES.
2.TRENCH SHORING IS TO BE INSTALLED AS EXCAVATION PROGRESSES IN A MANNER TO MINIMIZE
THE AREA OF UNSUPPORTED TRENCH AND MAINTAIN POSITIVE PRESSURE ON THE TRENCH WALLS.
LIMIT EXCAVATION AHEAD OF INSTALLED PIPE TO TWO PIPE LENGTHS. BACKFILL AND COMPACT
AS INSTALLATION PROGRESSES IN A MANNER THAT MINIMIZES THE AREA OF UNSUPPORTED
TRENCH.
3.TRENCH SHIELDING (TRENCH BOX) IS ACCEPTABLE AT THE PIPE BELL LOCATION FOR PIPE
INSTALLATION PROVIDED THAT THE TRENCH WALL AHEAD OF THE TRENCH BOX IS SUPPORTED
WITH SHORING. REMOVAL OF SHORING FOR MOVEMENT OF TRENCH BOX TO THE SUBSEQUENT PIPE
BELL LOCATION SHALL OCCUR IN A MANNER TO MINIMIZE THE AREA OF UNSUPPORTED TRENCH.
4.THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL TRENCH SHORING, SHIELDING AND
SAFETY MEASURES COMPLY TO OSHA RULES AND REGULATIONS.
5.POTHOLE AND PROTECT ADJACENT UTILITIES LOCATED WITHIN A ANTICIPATED SKIN-TO-SKIN
DISTANCE OF 2 TIMES THE EXCAVATION LIMITS OF THE PROPOSED TRENCH, OR MIN. 5'
WHICHEVER IS GREATER.
6.TV INSPECTION FOR DAMAGE REQUIRED AT ALL STORM CROSSINGS WHERE PROPOSED WATERMAIN
IS INSTALLED WITH 12" OR LESS VERTICAL SEPARATION.
TRENCH WIDTH PER
SPECIAL PROVISIONS
SECTION 7-08.3
CONTRACTOR DESIGNED SHORING AS REQUIRED FOR
PROTECT THE EXISTING AND ADJACENT UTILITIES AND
CONSTRUCT THE PROPOSED IMPROVEMENTS, TYP.
CONFIRM BEDDING AND BACKFILL MATERIAL
DURING POTHOLE OF ADJACENT UTILITIES AND
PLAN PROTECTION OF UTILITY ACCORDINGLY, TYP.
PROTECT ALL UTILITIES IN PLACE. UTILITIES SCHEDULED
FOR REPLACEMENT MAY BE SECTIONED OUT WITH
TEMPORARY REPAIR UNTIL FINAL REPAIR. CONFLICTING
SEWER UTILITIES SHALL BE REPORTED TO THE OWNER
AND WILL BE RELOCATED PER DETAIL
SS1
D03
SEE NOTE 5
EXISTING
CATCH BASIN
EXISTING SEWER, POTHOLE
AT ALL CROSSINGS
EXISTING STORM, POTHOLE
AT ALL CROSSINGS
1' MIN.1' MIN.
PERMANENT HMA, CL 1/2"
PG 58H-22 TO MATCH
THICKNESS OF EXISTING
ASPHALT OR 8" MINIMUM.
SAND BEDDING MATERIAL
PER SECTION 9-03.13 OF THE
STANDARD SPECIFICATIONS
RED ELECTRICAL WARNING TAPE
CENTERED OVER CONDUIT IN TRENCH
3" SCH. 80 PVC CONDUIT
(WHERE APPLICABLE)
UPPER LIMIT PIPE ZONE
TRENCH BACKFILL, GRAVEL BORROW PER SECTION
9-03.14(1) AND COMPACTED IN 6" MAX. LIFTS TO
95% MAXIMUM DRY DENSITY (MDD) AS DETERMINED
BY MODIFIED PROCTOR TEST (ASTM D1557).
PIPE ZONE BEDDING, CSBC PER SECTION
9-03.9(3) AND COMPACTED IN 6" MAX. LIFTS TO
95% MAXIMUM DRY DENSITY (MDD) AS DETERMINED
BY MODIFIED PROCTOR TEST (ASTM D1557).
LOWER LIMIT PIPE ZONE
CSBC COMPACTED TO A
NON-YIELDING CONDITION REQ'D FOR
UNSTABLE SOILS, SEE TRENCH NOTE 4
NATIVE IN-SITU MATERIAL
WHERE DIRECTED BY THE ENGINEER, PROVIDE A LAYER
OF NON-WOVEN GEOTEXTILE PER SECTION 9-33.2(1)
TABLE 3, MIRAFI 160N OR EQUAL AS SEPARATION
BETWEEN FOUNDATION MATERIAL AND IN-SITU.
POLYWRAP REQUIRED FOR WATER MAIN
COMPACT BEDDING AND BACKFILL WITH HAND
OPERATED MECHANICAL COMPACTOR TO 1-FT ABOVE
PIPE CROWN, HOE PACK MAY BE USED ABOVE 1-FT.
CONTRACTOR SHALL NOT DAMAGE PIPE.
LOCATING MARKING TAPE,
LOCATE 12" ABOVE TOP
OF PROPOSED WATER PIPE.
ALTERNATE BACK SLOPE AT CONTRACTORS
OPTION AND AT NO ADDITIONAL COST TO THE
CITY OF RENTON, SEE RESTORATION NOTES ON
DWG D02 FOR ADDITIONAL INFORMATION.
CSTC PER SECTION 9-03.9(3) COMPACTED
TO 95% OF MAX DENSITY, MIN. 6" THICKNESS.
EXISTING PAVEMENT
2" GRIND AND REMOVAL OR PLANE. SEAL
WITH AR-400W (EACH SIDE). OVERLAY
WITH 2" HMA CL 1/2" PG 58H-22
CONFIRM BEDDING AND BACKFILL
MATERIAL DURING POTHOLE OF ADJACENT
UTILITIES AND PLAN PROTECTION OF
UTILITY ACCORDINGLY, TYP.
EXISTING STORM, POTHOLE
AT ALL CROSSINGS
PROPOSED WATER MAIN
EXISTING WATER MAIN
SAWCUT AFTER BACKFILL (EACH SIDE)
2" HMA CL 1/2"
PG 58H-22
AH
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
6
.
D
W
G
SHOWN
D01 67 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
CI
V
I
L
A
N
D
U
T
I
L
I
T
I
E
S
D
E
T
A
I
L
S
0
1
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
TYPICAL ROADWAY RESTORATION - GRIND AND OVERLAYR4
2%2%
FULL WIDTH GRIND AND OVERLAY (2" MIN. DEPTH)
HMA CL. 12" PG 58H-22, COMPACTED DEPTH PER STANDARD SPECIFICATIONS
PERMANENT HMA PROPERTY RESTORATION DETAIL
NOTES:
1.SEE TRENCH AND RESTORATION NOTES FOR
COMPACTION TESTING REQUIREMENTS.
2.ALL TRENCHES IN ROADWAY AREAS SHALL BE
BACKFILLED AND TEMPORARILY PATCHED WITH 2"
MIN. HMA AT END OF EACH WORK DAY.
3.THE FINAL PATCH SHALL BE INSTALLED WITHIN
TWO (2) WEEKS OF FINAL INSPECTION AND
TRANSFER OF SERVICE TO THE NEW WATERMAIN.
SEE TRENCH DETAIL FOR ADDITIONAL
INFORMATION, COMPACTED NATIVE
SHOWN.
EDGE OF PAVEMENT, EDGE OF CURB &
GUTTER, OR CENTER OF LANE LINE. GRIND
AND REMOVE OR PLANE. SEAL WITH AR4000W.
EXISTING PAVEMENT, SEE DWG
NOS P01-P10 FOR POTHOLES
WITH HMA THICKNESS.
NATIVE MATERIAL
6" COMPACTED DEPTH OF CSTC PER STD.
SPECIFICATION 9-03.9(3), COMPACTED TO 95%
MAXIMUM DRY DENSITY (MDD) AS DETERMINED
BY MODIFIED PROCTOR TEST (ASTM D1557).
LANDSCAPED AREA RESTORATION DETAIL
NATIVE MATERIAL
EXISTING LANDSCAPED
AREA
SEE TRENCH DETAIL FOR
ADDITIONAL INFORMATION, TYP.
IN LANDSCAPED OR CULTIVATED AREAS, THE
CONTRACTOR SHALL RESTORE THE TRENCH TO
MATCH EXISTING GRADE AND SURFACE TREATMENT.
RESTORE LAWN W/ SOD, SEED, OR BARK MULCH.
GRAVEL RESTORATION DETAIL
NATIVE MATERIAL
EXISTING GRAVELCSTC PER STD. SPECIFICATION 9-03.9(2),
COMPACTED TO 90% MDD. MATCH EXISTING GRAVEL
THICKNESS OR MIN. 6", WHICHEVER IS GREATER.
SEE TRENCH DETAIL FOR
ADDITIONAL INFORMATION, TYP.
1.ALL TRENCH AND SURFACE RESTORATION SHALL BE ACCORDING TO THESE PLANS AND CITY OF RENTON ROAD DESIGN AND CONSTRUCTION STANDARDS. WHERE CONFLICTS OCCUR, THE MORE STRINGENT OF THE TWO REQUIREMENTS SHALL APPLY.
2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSAL OF ALL EXCAVATED PAVEMENT AND OTHER UNSUITABLE MATERIALS.
3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND DISPOSAL OF PAVEMENT DAMAGED OUTSIDE OF PAY LIMITS. THE CONTRACTOR SHALL ALSO FURNISH ALL WORK AND MATERIALS NECESSARY TO RESTORE THE ROADWAY DAMAGED
OUTSIDE OF THE PAY LIMITS AT NO ADDITIONAL EXPENSE TO THE OWNER.
4.THE CONTRACTOR SHALL REPLACE AND REPAINT STREET MARKINGS DAMAGED DURING CONSTRUCTION.
5.MATCH EXISTING SLOPES FOR PAVEMENT AND GRAVEL DRIVEWAY RESTORATION. PAVEMENT SLOPES SHALL BE A MINIMUM OF 2% FROM CENTERLINE TO EDGE.
6.ALL TRENCHING AND SHORING TO BE DONE IN ACCORDANCE WITH OSHA AND WISHA STANDARDS.
7.TACK ALL EDGES PRIOR TO PAVING.
8.IF EXISTING GRAVEL SHOULDER IS DISTURBED, CONTRACTOR SHALL RESTORE WITH 6" DEPTH OF CSTC PER STD. SPECIFICATION 9-03.9(3).
9.IN LANDSCAPED OR CULTIVATED, NON-PAVED, NON-GRAVELED AREAS RESTORE SURFACE WITHIN DISTURBED AREA TO EQUAL OR BETTER THAN EXISTING CONDITION, INCLUDING SAND, TOP SOIL, GRASS, SHRUBS, ETC. HYDROSEED ALL DISTURBED
AREAS PER SPECIAL PROVISION 9-14.9.
10.WITHIN ROADWAY, ENTIRE TRENCH SHALL BE COMPACTED MECHANICALLY TO 95% MAX. DENSITY AS DETERMINED BY WSDOT/APWA STD. SPECIFICATION 2-03.3(14)D. MAX. 6" LIFTS ALLOWED UNLESS IT IS DEMONSTRATED THAT COMPACTION
REQUIREMENTS CAN BE MET WITH 12" LIFTS.
11.CONTRACTOR TO PROVIDE STEEL PLATES IN AREAS REQUIRED TO BE OPEN TO TRAFFIC AND PRIOR TO FINAL TRENCH RESTORATION AS DIRECTED BY THE ENGINEER. PLATES SHALL BE TREATED FOR VEHICLE SKID RESISTANCE.
12.THE CONTRACTOR SHALL MAINTAIN TRENCH PATCHES TO THE TIME OF PAVING TO PREVENT DAMAGE TO EXISTING PAVEMENT RESULTING FROM VEHICLE TRAFFIC.
13.THE CONTRACTOR SHALL CLEAN EXISTING PAVEMENT, PERFORM EXTRA SAW CUTS NECESSARY TO CREATE CLEAN PAVEMENT CUTS, REMOVE DAMAGED PAVEMENT, REGRADE, AND COMPACT ALL CSTC IN PREPARATION FOR PAVING. PAVING SHALL BE
PERFORMED IN ACCORDANCE WITH THE STD. SPECIFICATIONS AND AS DEFINED IN THE NOTES BELOW.
14.TRENCH WIDTH FOR RESTORATION AND BACKFILL PURPOSES SHALL BE DEFINED BASED ON NEATLINE TRENCH LIMITS AS DEFINED IN THE TRENCH DETAIL. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SURFACE RESTORATION INCLUDING WIDER
REPAIR SECTIONS RESULTING FROM ALTERNATE BACK SLOPES AT TRENCH SIDES.
CONSTRUCTION AND RESTORATION NOTES
R1
R2 R3
2" HMA (CL. 12" PG 58H-22)
MATCH EXISTING PAVEMENT THICKNESS
OR 6" MIN. HMA (CL. 12" PG 58H-22),
WHICHEVER IS GREATER.
WIDTH VARIES PER PLANS
12" MIN.
BOTH SIDES
WIDTH VARIES PER PLANS
12" MIN.
BOTH SIDES
WIDTH VARIES PER PLANS
12" MIN.
BOTH SIDES
MAINTAIN CONTINUOUS SLOPE
THROUGH EDGE GRIND (NO BREAK)
EDGE GRIND AND TACK ALL SURFACES
CONTRACTOR TO RESTORE CURB,
SIDEWALK, AND SHOULDER/LANDSCAPED
WHERE DISTURBED BY CONSTRUCTION
TO CITY STANDARDS, EACH SIDE.
EXISTING CONCRETE SIDEWALK
EXISTING ASPHALT ROADWAY
EXISTING SUBBASE
PROVIDE TRENCH RESTORATION
PER DETAIL T1 ON DWG NO. D01.
EXISTING GRASS/
LANDSCAPING
EXISTING CURB, TYP.
NATIVE MATERIAL NEW SUBGRADE
CL OF ROADWAY
LOW LIMIT PIPE ZONE
LOCATING MARKING TAPE, LOCATE 12"
ABOVE TOP OF PROPOSED WATER PIPE.
NOT REQUIRED FOR STORM PIPE.
TRENCH WIDTH PER SPECIAL
PROVISION SECTION 7-08.3
CSBC PER SECTION 9-03.9(3) AS DIRECTED
BY THE ENGINEER COMPACTED TO A
NON-YIELDING CONDITION
PIPE ZONE BEDDING, CSBC PER
SECTION 9-03.9(3) COMPACTED
TO 95% OF MAX DENSITY
TRENCH BACKFILL, GRAVEL BORROW
PER SECTION 9-03.14(1) COMPACTED
TO 95% OF MAX DENSITY
UPPER LIMIT PIPE ZONE
PIPE, SIZE, AND MATERIAL AS SPECIFIED.
POLYWRAP REQUIRED FOR WATER MAIN.
PIPE COVER
DEPTH OF COVER MEASURED FROM FINISH GRADE TO TOP OF PIPE:
1.MIN. 36" FOR WATER MAIN 10" IN DIAMETER OR SMALLER.
2.MIN. 48" FOR WATER MAIN 12" IN DIAMETER OR LARGER.
3.MIN. 24" FOR STORM DRAIN PIPE.
NOTE:
1.WHEN POOR QUALITY FOUNDATION IS ENCOUNTERED BELOW THE
BEDDING ZONE OR WHEN DIRECTED BY THE ENGINEER,
OVER-EXCAVATE AND PROVIDE AND INSTALL CSBC, MEETING THE
REQUIREMENTS OF STD. SPEC. 9-03.9(2). THE USE OF GEOTEXTILE
SEPARATION FABRIC MAY ALSO BE REQUIRED BY THE ENGINEER
TO STABILIZE THE BASE.
2.RECYCLED MATERIAL AS DEFINED BY WSDOT STD. SPECIFICATIONS
9-03.21 SHALL NOT BE ALLOWED IN ANY PIPE ZONE BEDDING OR
TRENCH BACKFILL.
6" MIN.
O.D.
12"
EXISTING PAVEMENT
2" GRIND AND REMOVAL OR PLANE.
SEAL WITH AR-400W (EACH SIDE)
PERMANENT HMA, CL 1/2" PG 58H-22
TO MATCH THICKNESS OF EXISTING
ASPHALT OR 8" MINIMUM
CSTC PER SECTION 9-03.9(3) COMPACTED TO 95%
OF MAX DENSITY, MIN. 6" THICKNESS.
1' MIN.1' MIN.1' MIN.1' MIN.
NEAT LINE TRENCH
T6
TYP.
TYPICAL TRANSVERSE WATER MAIN AND STORM PIPE TRENCH
AND PATCH WITH HMA PAVEMENT AND OVERLAY SECTION
NOT TO SCALE
TRENCH WIDTH PER
SPECIAL PROVISION
SECTION 7-08.3 1' MIN.1' MIN.1' MIN.1' MIN.
2" GRIND AND
HMA OVERLAY
HMA PERMANENT PATCH
T-CUT. MATCH EXISTING HMA
THICKNESS, MIN. 8" THICKNESS.
NEAT LINE TRENCH
TRENCH BACKFILL
PIPE, SIZE, AND MATERIAL AS SPECIFIED.
POLYWRAP REQUIRED FOR WATER MAIN.
TYPICAL TRANSVERSE WATER MAIN AND STORM PIPE TRENCH
AND PATCH WITH HMA PAVEMENT AND OVERLAY PLAN VIEW
NOT TO SCALE
DEPTH OF EXISTING
PAVEMENT
8' MIN.
2" HMA CL. 1/2" PG
58H-22 OVERLAY
8" MIN. COMPACTED DEPTH OF IMPORTED
TOPSOIL MIX PER SPECIAL PROVISIONS
SECTIONS 8-02.3(4)A AND 9-14.2(1)
PROVIDE GEOTEXTILE FABRIC PER WSDOT STD.
SPECIFICATIONS 9-33.2(1) TABLE 3, NON-WOVEN MIRAFI 160N,
OR EQUAL, AS DIRECTED
EXCAVATE UNSUITABLE SOIL
WHEN EXISTING SUBGRADE
CONDITIONS REQUIRE
SAWCUT AFTER
BACKFILL (EACH SIDE)
TYPICAL CONCRETE DRIVEWAY REPAIR
EXISTING HMA SURFACE
NATIVE MATERIAL
6" MIN. COMPACTED DEPTH OF CSTC PER STD.
SPECIFICATION 9-03.9(3), COMPACTED TO 95%
MAXIMUM DRY DENSITY (MDD) AS DETERMINED
BY MODIFIED PROCTOR TEST (ASTM D1557).
R5
MATCH EXISTING CEMENT CONCRETE
THICKNESS AND NEAREST FULL DEPTH
EXPANSION JOINT
APPROX. 7'-6"EXISTING CONCRETE SURFACE
PROPOSED CONCRETE SURFACE#4 @ 12" O.C. BOTH WAYS
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
PG
L
KM
P
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
6
.
D
W
G
SHOWN
D02 68 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
CI
V
I
L
A
N
D
U
T
I
L
I
T
I
E
S
D
E
T
A
I
L
S
0
2
PIPE INSTALL AND TRENCH
RESTORATION PER TRENCH
DETAIL T1
PIPE ZONE BEDDING PER
TRENCH DETAIL T1
TRENCH BACKFILL, GRAVEL BORROW
PER SECTION 9-03.14(1) COMPACTED
TO 95% OF MAX DENSITY
EXISTING PAVEMENT
2" GRIND AND REMOVAL OR PLANE. SEAL
WITH AR-400W (EACH SIDE), OVERLAY
WITH 2" HMA CL 1/2" PG 58H-22PERMANENT HMA, CL 1/2" PG
58H-22 TO MATCH THICKNESS OF
EXISTING ASPHALT OR 8" MINIMUM
CSTC PER SECTION 9-03.9(3) COMPACTED TO 95%
OF MAX DENSITY, MIN. 6" THICKNESS.
1' MIN.1' MIN.1' MIN.1' MIN.
NEAT LINE TRENCH
T7
TYP.
TYPICAL LONGITUDINAL STORM PIPE REMOVAL ADJACENT TO
WATER MAIN SECTION WITH OVERLAY
NOT TO SCALE
DEPTH OF EXISTING
PAVEMENT
2" HMA CL. 1/2" PG
58H-22 OVERLAY
EXCAVATE UNSUITABLE SOIL
WHEN EXISTING SUBGRADE
CONDITIONS REQUIRE
WHERE CLEARANCE BETWEEN TRENCH LIMITS IS
LESS THAN 18", REMOVE MATERIAL BETWEEN
TRENCHES TO LOWER LIMIT OF PIPE BEDDING ZONE
AND BACKFILL WITH GRAVEL BORROW PER SECTION
9-03.14(1) COMPACTED TO 95% OF MAX DENSITY.
PIPE INSTALL AND TRENCH
RESTORATION PER TRENCH
DETAIL T1
PIPE ZONE BEDDING PER
TRENCH DETAIL T1
TRENCH BACKFILL, GRAVEL BORROW
PER SECTION 9-03.14(1) COMPACTED
TO 95% OF MAX DENSITY
EXISTING PAVEMENT
2" GRIND AND REMOVAL OR PLANE. SEAL
WITH AR-400W (EACH SIDE), OVERLAY
WITH 2" HMA CL 1/2" PG 58H-22
PERMANENT HMA, CL 1/2" PG
58H-22 TO MATCH THICKNESS OF
EXISTING ASPHALT OR 8" MINIMUM
CSTC PER SECTION 9-03.9(3)
COMPACTED TO 95% OF MAX
DENSITY, MIN. 6" THICKNESS.
1' MIN.1' MIN.1' MIN.1' MIN.
NEAT LINE TRENCH
DEPTH OF EXISTING
PAVEMENT
EXCAVATE UNSUITABLE SOIL
WHEN EXISTING SUBGRADE
CONDITIONS REQUIRE
WHERE CLEARANCE BETWEEN TRENCH
LIMITS IS 18" OR MORE, LEAVE NATIVE
MATERIAL BETWEEN TRENCHES
1' MIN.1' MIN.
IF NEW STORM PIPE IS TO REPLACE THE
EXISTING STORM PIPE BEING REMOVED,
INSTALL PIPE AND RESTORE TRENCH PER
TRENCH DETAIL T1
IF NEW STORM PIPE IS TO REPLACE THE
EXISTING STORM PIPE BEING REMOVED,
INSTALL PIPE AND RESTORE TRENCH PER
TRENCH DETAIL T1
STORM PIPE REMOVAL
STORM PIPE REMOVAL
SAWCUT AFTER
BACKFILL (EACH SIDE)
SAWCUT AFTER
BACKFILL (EACH SIDE)
WHERE SEPARATION BETWEEN
TRENCH LIMITS IS 4'-0" OR MORE,
SEPARATE T-CUTS ARE REQUIRED
CASE A: CLEARANCE BETWEEN TRENCH LIMITS IS LESS THAN 18"
CASE B: CLEARANCE BETWEEN TRENCH LIMITS IS GREATER THAN 18"
2" HMA CL. 1/2" PG
58H-22 OVERLAY
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
6
.
D
W
G
SHOWN
D03 69 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
CI
V
I
L
A
N
D
U
T
I
L
I
T
I
E
S
D
E
T
A
I
L
S
0
3
WET UTILITY REPAIR/REPLACEMENT
CUT PIPE SQUARE
1' MIN FROM BREAK OR TRENCH WALL, TYP.
DAMAGED OR REMOVED GRAVITY SEWER/STORM PIPE
WET UTILITY REPAIR/REPLACEMENT NOTES:
1.REPAIRS SHALL BE MADE WITH SHEAR RESISTANT COUPLINGS, MISSION ARC, FERNCO 5000 RC SERIES OR EQUAL.
COUPLER SHALL HAVE WATER TIGHT SEAL. THE CITY MAY ALLOW TEMPORARY OPEN TRENCH REPAIRS TO BE
MADE WITH FLEXIBLE COUPLINGS IF SHEAR RESISTANT COUPLINGS ARE NOT ON HAND.
2.COUPLING BETWEEN DIFFERENT PIPE MATERIALS OR OUTSIDE DIAMETERS SHALL BE MADE USING ADAPTERS
SPECIFIED BY THE COUPLER MANUFACTURER.
3.ALL REPAIRS SHALL MAINTAIN EXISTING GRADE.
4.ALL HARDWARE (INCLUDING BANDING) SHALL BE STAINLESS STEEL.
5.IN THE CASE OF A DAMAGED PIPE THE CITY SHALL BE IMMEDIATELY NOTIFIED. THE CITY SHALL INSPECT AND
APPROVE REPAIR BEFORE BACKFILLED.
SHEAR RESISTANT COUPLER
STAINLESS STEEL
HARDWARE
REPAIRED GRAVITY SEWER/STORM PIPE
NEW DUCTILE IRON PIPE WITH SAME
ID AS EXISTING PIPE
ALIGN PIPE INVERTS, CREATE
SMOOTH TRANSISITION
COUPLER ADAPTER SPECIFICED BY
MANUFACTER FOR PIPE OD DIFFERENCE
U01
RESTRAINED JOINT PIPE DETAIL
NTS
SIDE SEWER RELOCATION BELOW PROPOSED PIPE
EXISTING TEE,
SEE NOTE 1
0.05 FT/FT MIN. SLO
P
E
0.02 FT/FT MIN. SLOPE
CLEANOUT,
SEE NOTE 5
EXISTING SIDE
SEWER
REMOVE CONFLICTING
EXISTING SIDE SEWER
PROPOSED WATER
MAIN OR STORM PIPE
6" MIN.
3" MIN.EXISTING TEE,
SEE NOTE 1
CLEANOUT, SEE NOTE 5
EXISTING SIDE
SEWERREMOVE CONFLICTING
EXISTING SIDE SEWER
PROPOSED WATER
MAIN OR STORM PIPE
CONNECT SIDE SEWER
WITH "STRONG-BACK"
FLEXIBLE COUPLING
INSTALL 6"x4" REDUCER
IF NEEDED
1/8, 1/16, OR 1/32
BENDS AS NEEDED
BEND IF NEEDED
NEW 4" OR 6"
SIDE SEWER
EXISTING
SEWER MAIN
ETHAFOAM PAD,
SEE NOTE 4
NOTES:
1.IF EXISTING TEE IS NOT USEABLE FOR RECONNECTION, SEE COR STD. PLAN 406.1 FOR ACCEPTABLE PROCEDURES FOR SIDE SEWER
CONNECTIONS TO EXISTING SEWER MAIN.
2.CONCRETE BLOCK REQUIRED AT NEW SADDLE WHEN ANGLE AT MAIN EXCEEDS 25°. SEE COR STD. PLAN 406.1.
3.ALLOWABLE SIDE SEWER PIPE AND FITTINGS:
POLYVINYL CHLORIDE (PVC) SDR 35
OTHER MATERIALS, AS APPROVED BY ENGINEER.
4.FOR 3" SEPARATION, INSTALL 1'x2'x2" THICK ETHAFOAM PAD BETWEEN NEW PIPE AND 4" OR 6" SIDE SEWER RELOCATION.
5.IF NEW SD CONFLICTS WITH A CLEAN OUT RISER, RELOCATE AND INSTALL NEW CLEANOUT PER COR STD. PLAN 406.1 AT LOCATION
APPROVED BY ENGINEER.
6.ALL SIDE SEWER RECONSTRUCTIONS SHALL BE APPROVED BY ENGINEER.
45° MAX.
SIDE SEWER RELOCATION
SIDE SEWER RELOCATION ABOVE PROPOSED PIPE
SS1
TYP.
NEW 4" OR 6"
SIDE SEWER
CSBC (CRUSHED SURFACING BASE COURSE) PER SECTION 9-03.9(3),
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
6
.
D
W
G
SHOWN
D04 70 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
CI
V
I
L
A
N
D
U
T
I
L
I
T
I
E
S
D
E
T
A
I
L
S
0
4
CITY
EX
.
W
A
T
E
R
STRADDLE BLOCK, FIELD LOCATE WITH CITY
APPROVAL CLEAR OF EXISTING UTILITIES ON
SAME EXISTING PIPE AS PROPOSED CONNECTION.
SEE DETAIL FOR FURTHER INFORMATION.
CUT AND ABANDON EXISTING
PIPE AND VALVES AS DESCRIBED
PER WATER MAIN PLANS
(2) DI BENDS (RJxRJ) AS INDICATED ON PLANS.
LOCATE AND ROLL BENDS TO ACHIEVE
VERTICAL AND HORIZONTAL ALIGNMENT.TEMPORARY CAP W/ BLOW-OFF
AND TESTING ASSEMBLY AND
THRUST BLOCK
PROPOSED PIPE AND
FITTINGS PER PLAN
BEGIN CONNECTION
TO EXISTING
REMOVE TEMPORARY BLOW-OFF
ASSEMBLY AND THRUST BLOCK
DI SPOOL, LTF
THRUST BLOCKING AS
INDICATED ON WATER
MAIN PLANS, TYP.
EX
.
W
A
T
E
R
TESTING CONFIGURATION FINAL CONFIGURATION
U04A
TYP.
U05
--
STRADDLE THRUST BLOCKING AND TIE RODS DETAIL U05
--
EXISTING WATERLINE, SIZE
AND MATERIAL VARIES
EX
.
W
A
T
E
R
STRADDLE BLOCK, FIELD LOCATE WITH CITY
APPROVAL CLEAR OF EXISTING UTILITIES ON
SAME EXISTING PIPE AS PROPOSED CONNECTION.
SEE DETAIL FOR FURTHER INFORMATION.
CUT AND ABANDON EXISTING
PIPE AND VALVES AS DESCRIBED
PER WATER MAIN PLANS
DI 90° BEND (RJxRJ). LOCATE AND ROLL
BEND TO ACHIEVE VERTICAL AND
HORIZONTAL ALIGNMENT.
TEMPORARY BLIND FLANGE W/
THREADED TAP AND BLOW-OFF
AND TESTING ASSEMBLY
PROPOSED PIPE AND
FITTINGS PER PLAN
BEGIN CONNECTION
TO EXISTING
REMOVE TEMPORARY
BLIND FLANGE AND
BLOW-OFF ASSEMBLY
DI SPOOL, LTF
EX
.
W
A
T
E
R
GENERALIZED CONNECTION TO EXISTING WATER MAIN
TESTING CONFIGURATION FINAL CONFIGURATION
U04B
TYP.
U05
--
DI GATE VALVE (FLxRJ). IF ADJACENT TEE IS
ROLLED, GATE VALVE SHALL BE INSTALLED
BETWEEN 90° BEND AND COUPLING/SLEEVE
WITH RJxRJ ENDS.
THRUST BLOCKING AS
INDICATED ON WATER
MAIN PLANS, TYP.
DI PLUG WITH
CONCRETE BLOCKING
AT EACH CONNECTION LOCATION, CONFIRM NECESSITY OF
STRADDLE BLOCKS WITH COR PRIOR TO CONNECTION.
GENERAL RULES FOLLOW, BUT DO NOT TAKE PRECEDENCE:
A.FOR DI WATER MAINS, INSTALL LONG BODY SLEEVE
(RJxRJ) AND TIE SHACKLE RODS INTO SLEEVE.
B.FOR ALL OTHER MATERIAL WATER MAINS, INSTALL
TRANSITION COUPLING AND TIE SHACKLE RODS INTO
DI BEND
GENERALIZED CONNECTION TO EXISTING WATER MAIN
NOTES:
1.THIS DETAIL IS INTENDED TO INDICATE THE BEGINNING OF THE CONNECTION TO EXISTING BID ITEM AND TO SHOW REQUIRED TESTING CONFIGURATION.
2.PIPE AND FITTING CONFIGURATIONS SHOWN ARE STRICTLY CONCEPTUAL IN NATURE AND ARE NOT AN EXACT REPRESENTATION OF EXISTING AND PROPOSED PIPE
AND FITTINGS AT ANY CONNECTION TO EXISTING LOCATION. SEE DWG NOS. WC01-WC14 FOR POTENTIAL TESTING AND FINAL CONFIGURATIONS FOR INDIVIDUAL
CONNECTIONS TO EXISTING, SPECIFIC TO EACH CONNECTION.
3.EXISTING UTILITIES NOT SHOWN ON GENERAL CONNECTION DETAILS. SEE PLAN AND CONNECTION PROFILES FOR EXISTING UTILITIES AT CONNECTIONS.
BEGIN CONNECTION
TO EXISTING
DI TEE (RJxRJ). LOCATE AND
ROLL TEE TO ACHIEVE VERTICAL
AND HORIZONTAL ALIGNMENT
EXISTING WATERLINE, SIZE
AND MATERIAL VARIES
EXISTING WATERLINE, SIZE
AND MATERIAL VARIES
EXISTING WATERLINE, SIZE
AND MATERIAL VARIES
EXISTING WATER MAIN
PIPE AND FITTINGS
EXISTING WATER MAIN
PIPE AND FITTINGS
AT EACH CONNECTION LOCATION, CONFIRM NECESSITY OF
STRADDLE BLOCKS WITH COR PRIOR TO CONNECTION.
GENERAL RULES FOLLOW, BUT DO NOT TAKE PRECEDENCE:
A.FOR DI WATER MAINS, INSTALL LONG BODY SLEEVE
(RJxRJ) AND TIE SHACKLE RODS INTO SLEEVE.
B.FOR ALL OTHER MATERIAL WATER MAINS, INSTALL
TRANSITION COUPLING AND TIE SHACKLE RODS INTO
DI BEND
NOTES:
1.THIS DETAIL IS INTENDED TO INDICATE THE BEGINNING OF THE CONNECTION TO EXISTING BID ITEM AND TO SHOW REQUIRED TESTING CONFIGURATION.
2.PIPE AND FITTING CONFIGURATIONS SHOWN ARE STRICTLY CONCEPTUAL IN NATURE AND ARE NOT AN EXACT REPRESENTATION OF EXISTING AND PROPOSED PIPE
AND FITTINGS AT ANY CONNECTION TO EXISTING LOCATION. SEE DWG NOS. WC01-WC14 FOR POTENTIAL TESTING AND FINAL CONFIGURATIONS FOR INDIVIDUAL
CONNECTIONS TO EXISTING, SPECIFIC TO EACH CONNECTION.
3.EXISTING UTILITIES NOT SHOWN ON GENERAL CONNECTION DETAILS. SEE PLAN AND CONNECTION PROFILES FOR EXISTING UTILITIES AT CONNECTIONS.
L
PIPE DIA
4" AND 6"
8"
10"
A (MIN)
12"
SIZING TABLE
52"
42"
36"
H (MIN)
24"
18"
18"
T (MIN)
10"
8"
4" AND 6"
PIPE DIA SOFT CLAY
54"
80"
98"54"
48"
48"
SANDY SILTSILT
48"
66"
78"
PLAN VIEW
ELEVATION
H
T
MIN. BLOCK LENGTH (L)
SOIL CONDITION
A (TYP)
6" MIN
(TYP.)
18" MIN
END VIEW
2' TO 10'
#4 @ 12" OC EW
#4 @ 12" OC EW
#4 @ 10" OC EW
REINFORCING
H
CONNECTION TO PIPE
OR FITTING WHICH IS
NOT THRUST BLOCKED
12"
12"
ATTACHMENT DETAIL
2' MIN. TYP.
TYPICAL
TRENCH
WIDTH
4
3
2
NUMBER OF RODS PER JOINT
6
4
2
5/8" DIA. ROD 3/4" DIA. ROD
EXISTING
UNRESTRAINED
PIPE
TIE RODS
BLOCK "KEYED" INTO
UNDISTURBED SOIL.
SEE NOTE 7.
TIE RODS
REINFORCING
BOTH FACES
DOUBLE NUTS
OR LOCKING
NUT
WASHER
#4 BAR
REINFORCING
(TYP)
TIE
BOLT
TIE
ROD EX. PIPE
FITTING
HDG STEEL
RISER CLAMP
12"54"24"#4 @ 8" OC EW18"68 12"120"66"92"
NOTE: THIS DETAIL FOR SURGE PRESSURES UP TO 200 PSI
3" CLR (TYP)3" CLR
(TYP)
1. CONCRETE BLOCK SHALL BE CLASS 3500 PSI CONCRETE (MIN.) WITH 3/4" AGGREGATE AND SLUMP OF 2"-4".
2. MAINTAIN 18" MINIMUM COVER OVER THE TOP OF BLOCK.
3. BOTTOM OF BLOCK IS TO BE ON UNDISTURBED SOIL. DO NOT INSTALL BLOCK ON PIPE JOINT.
4. TRENCH TO BE BACKFILLED WITH CRUSHED ROCK COMPACTED TO 95% DENSITY ON ALL SIDES OF BLOCK AND A DISTANCE OF 4' MIN. IN FRONT OF BLOCK TO
TOP OF BLOCK.
5. CONCRETE SHALL ACHIEVE AT LEAST 3000 PSI COMPRESSIVE STRENGTH AND (FOR ELASTICITY) HAVE CURED FOR AT LEAST 7 DAYS BEFORE PRESSURE
TESTING OF CONNECTION.
6. FOR SOIL CONDITIONS NOT SHOWN, BLOCK IS TO BE DESIGNED BY OWNER'S REPRESENTATIVE.
7. IF BLOCK CANNOT BE KEYED INTO UNDISTURBED SOIL TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE, a) THE BLOCK LENGTH SHALL BE
EXTENDED TO PROVIDE AN ADEQUATE KEY OR
b) THE TRENCH SHALL BE BACKFILLED AND COMPACTED TO 95% DENSITY A MINIMUM DISTANCE EQUAL TO NOMINAL PIPE SIZE NUMBER, BUT AS FEET
(EXAMPLE: A 10" PIPE WOULD REQUIRE 10' OF BACKFILL) IN FRONT OF THE BLOCK TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE BEFORE
PRESSURIZING.
8. FOR PIPE DIAMETERS LARGER OR FOR SOILS DIFFERENT THAN NOTED, BLOCK SIZING SHALL BE REVIEWED AND STAMPED BY A PROFESSIONAL ENGINEER
FOR THE SITE SPECIFIC CONDITIONS.
1) ALL TIE RODS, TIE ROD COUPLINGS, TIE BOLTS, NUTS, WASHERS, FLANGE LUGS AND ANY OTHER METALLIC TIE ROD SYSTEM COMPONENT SHALL BE ASTM
A242 (COR-TEN) STEEL. MILD STEEL IS NOT ALLOWED.
2) PROTECT TIE RODS, ROD COUPLINGS, AND TIE BOLTS/FLANGE LUGS WITH WAX TAPE COATING SYSTEM. WAX TAPE THE TIE RODS PRIOR TO POURING THE
CONCRETE. EXTEND POLYETHYLENE WRAP FROM CONNECTION, OVER THE TIE RODS, TO THE FACE OF BLOCK.
3) TIE RODS SHALL BE "ALL THREAD" ROD.
4) TIE RODS SHALL HAVE "NATIONAL-COARSE" THREAD WITH EITHER TWO NUTS OR ONE SELF-LOCKING NUT.
5) TIE RODS SHALL BE ASSEMBLED SYMMETRICALLY ABOUT EACH JOINT (IF AN EVEN NUMBER OF RODS ARE USED THEN EACH ROD SHALL HAVE A ROD
LOCATED ON THE DIRECT OPPOSITE SIDE OF JOINT. IF 3 OR 6 RODS ARE USED THEN AN EQUAL NUMBER OF UNSHACKLED BOLT HOLES SHALL BE LEFT BETWEEN
ANY TWO TIE RODS.)
6) TIE ROD NUTS SHALL BE TIGHTENED UNIFORMLY AT EACH JOINT. DO NOT OVER TIGHTEN; HAND SNUG PLUS 1/2 TURN.
7) TIE ROD LENGTHS SHALL NOT EXCEED 10', UNLESS SPECIFICALLY SHOWN ON APPROVED PLANS.
8) TIE RODS SHALL BE ATTACHED TO MECHANICAL JOINTS WITH TIE BOLTS, EXCEPT FOR FIRE HYDRANT INSTALLATIONS WHICH SHALL USE TIE LUGS. TIE BOLTS
SHALL BE ROMAC "90-DEGREE EYE BOLTS" OR APPROVED EQUAL. "DUC-LUGS" ARE NOT ALLOWED. FOR CONNECTION TO FLANGED FITTINGS, 3- HOLE FLANGE
LUGS SHALL BE USED. TIE BOLTS AND FLANGE LUGS SHALL BE RATED FOR AT LEAST 7,500 LB EACH.
NOTES
TIE RODS GENERAL NOTES
16"58"30"#4 @ 5" OC EW24"58 16"192"84"144"
CI
T
Y
O
F
R
E
N
T
O
N
HI
G
H
L
A
N
D
S
R
E
S
E
R
V
O
I
R
W
A
T
E
R
M
A
I
N
IM
P
R
O
V
E
M
E
N
T
S
P
R
O
J
E
C
T
WT
R
-
2
7
-
3
8
8
8
0
2/
4
/
2
0
2
6
IS
S
U
E
D
F
O
R
B
I
D
D
I
N
G
DM
F
RJ
F
DM
F
RJ
F
Fe
b
4
,
2
0
2
6
Fe
b
4
,
2
0
2
6
RE
N
11
3
-
1
0
4
HI
G
H
-
D
-
2
C
0
6
.
D
W
G
SHOWN
D05 71 71
0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
DWG NO.:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
S
BY
RE
V
I
E
W
EN
G
I
N
E
E
R
:
SA
V
E
D
A
T
E
:
RE
V
I
E
W
E
D
:
PL
O
T
D
A
T
E
:
CL
I
E
N
T
:
FI
L
E
N
A
M
E
:
SHEET NO.:
JO
B
N
O
.
:
NO
.
CI
V
I
L
A
N
D
U
T
I
L
I
T
I
E
S
D
E
T
A
I
L
S
0
5