Loading...
HomeMy WebLinkAboutT-42140110 z J w U Q Or x 70 z N 0 z w Of z 1 z Q U Z x z 0 z w ry 0 X z 0 z w ry 0 J x z 0 z w x z 0 z w n, x z 0 z w J Q z x 0 CV N zi) z 0 z w Of I w P. 0 ry a_ 3 0 x 0 ry cf)' m N N z 0 F- z w ry z 0 F- F- x 0 z w 0 w J x 0 a_ 0 F- 0 CV O ry w w o ry 0 m o Q _jo� J (6 CU � 00 E a' LU moo COo� CD N U 0 o w o S w x LLI cis 0 ~ W LU CD a-Q ox2Ei d S GRADY WAY w, 44 248, #8G PER PSE I 0 PSE PROVIDED #12-3TC, 248, #8G SECONDARY JB #12-3TC PSE PROVIDED UNDGR XFMR VAULT VAULT #317537-165998 ELECTRICAL WIRING SCHEMATIC LOCATION MAP U I S G RADY WAY 4___11111 STATION 55936 (OB) (GRA-LINE) TIER 1P P P P - P P P P � 1 4 1 F ----- i P ' P _j P _ \ -J J� 4 QY 1 3(13l 5 p ELEC \ PSE PROVIDED METRO RAPIDRIDE — — - — SECONDARY JB SHELTER METRO TECH PYLON \ PSE PROVIDED UNDGR XFMR VAULT­O VAULT #317537-165998 OB STATION PANEL: # VOLTAGE RATING: 120 VOLTS, 1 PHASE, 2 WIRE BUS RATING: 100 AMPS MAIN BREAKER: 60 AMPS FEED: BOTTOM FAULT CURRENT: 9,300 AMPS INTERRUPTING CAPACITY: 22,000 AMPS CIRCUIT DESCRIPTION VA CKT BRKR TECH PYLON 203 1 1/20 SHELTER LIGHTS 154 2 1/20 SPACE 3 SPACE 4 SPACE 5 SPACE 6 GFCI 180 7 1/20 CONNECTED LOAD = (203+154+180) = 537 VA = 4.475 AMPS AVERAGE CONTINUOUS LOAD = ((203+154)*1.25+180) = 626 VA = 5.219 AMPS AVERAGE AD -READY SUBMITTAL I � I I I ° A I J A � 1 C k j� ITS w • INIR KAM 1 _ I - lz\i/- WIRING SCHEDULE RUN NO. ZLCONDUIT SIZE SHELTER LIGHTS TECH PYLON GROUND SERVICE PULL TAPE REMARKS 1 2" RGS METRO SERVICE 244 2 2" RGS METRO ELEC. #12-3TC 248 #8G 3 3/4" RGS METRO ELEC. #12-3TC LABEL CONDUCTORS WITH "SHELTER LIGHTS" 4 1" RGS METRO ELEC. 248 #8G LABEL CONDUCTORS WITH "TECH PYLON" 5 1.5" PVC METRO ITS. 1 SPARE 6 2" PVC METRO ITS. 1 SPARE 7 PER PSE PER PSE PROVIDED BY PSE DESIGNED: yZNG , �� A. KING (425) 453-5000 WAS DRAWN: cob1 100 112TH AVE NE, SUITE 500 �w °F 6, Gl BELLEVUE, WA 98004 - ti1 - S XIA No. REVISION BY APP'D DATE concord ENGINEERING f y j CHECKED: j !I Q 4C434 9 , �01STS �j X. ZHANG ty " Gti 1 `SIGNAL :1� CHECKED: 6/12/2024 K. CHANG YUEN APPROVED: G.FRANCO PROJECT NO: E00566E18 CONTRACT NO: CXXXXXXXX LIM King County METRO GENERAL NOTES 1. PSE WILL PROVIDE CONDUIT(S) FROM THE PRIMARY SERVICE POINT TO A SECONDARY SERVICE JUNCTION BOX FOR STATION SERVICE CONNECTIONS PRIOR TO I LINE RAPIDRIDE CONSTRUCTION. 2. HAND DIGGING OR EXCAVATION BY VACTOR MAY BE REQUIRED FOR CONDUIT INSTALLATION IN AREAS WHERE EXISTING UNDERGROUND UTILITIES AND/OR TREE ROOTS ARE PRESENT. 3. INSTALL SPARE CONNECTIONS FOR FUTURE METRO FIBER OPTIC COMMUNICATION TO THE STATION. 4. SEE 1 S1.10 FOR STATION PLANS AND AMENITIES DETAILS. CONSTRUCTION NOTES OTRENCH AND INSTALL CONDUIT. ADJUST ROUTING OF TRENCH AND CONDUIT TO AVOID UTILITIES. OPROVIDE AND INSTALL 60A, 120V METRO NON -METERED ELECTRICAL SERVICE PEDESTAL. SEE 1 E2.01 FOR MOUNTING AND FOUNDATION DETAIL. THE FRONT DOOR OF THE CABINET SHALL BE ORIENTED AS SHOWN BY 7" ON THE PLANS. OPROVIDE AND INSTALL WSDOT TYPE 2 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.10-04. LABEL JUNCTION BOX "METRO". OSERVICE POINT. COORDINATE WITH PSE ELECTRICAL SERVICE REPRESENTATIVE FOR CONNECTION TO THE SECONDARY SERVICE JUNCTION BOX (SR# TO BE ISSUED AT A LATER DATE). 0' 10, 20' DEVELOPMENT ENGINEERING SCALE: 1" = 10' Michael Sippo 09/11 /2024 T-421411 METRO TRANSIT CAPITAL DIVISION DATE: RAPIDRIDE I LINE JUNE2024 RENTON SEGMENT DRAWING NO: ELECTRICAL SITE PLAN 1 E1.02 D# 55936 SHEET NO: OF 295 473