HomeMy WebLinkAboutT-4214018CV
N
C2
a
Z
O
z
w
a
Z
O
z
w
ry
3
O
X
z
O
z
w
rr
X
z
O
z
w
o'
J
X
z
O
z
w
CO
a
z
O
z
w
J
X
a
z
O
z
w
Of I
W
X
0
3
a
O
ry
a_
3
O
X
a
0
Z
W
(D
W
J
X
a
0
W
ry
m
N
CV
a
z
O
z
w
z
O
Q
X
a
z
c�
J
Q
X
0
N
O
N
Q_'
W
0
ry
O
00
0
o U
w Y
0 a
(a o
J (6 �
A Oi
a m co
of
N Q �
rn U
L1J M W
7: ED
a) _
00
,oC�)
C-
D N X
�� j�:
0 o O
o CL
(�:O
m0w�
Q
o a- xx 2Ei
LLI
u)
LLl
LLLLJ
=
II__
00
0
SE 180TH ST
-- — — — — — —
F
#12-3TC, 248, #8G #12-3TC 248, #8G
LOCATION MAP
MATCH LINE - SEE SHEET 1 E1.07
1 1 SE 180TH ST
I 6
I
�GF - \
6 1
3 1
— — — 5
ilR
4 /� ITS METRO RAPIDRIDE
SHELTER
4 1
ELEC 2 1 3
STATION 60323 (OB)
TIER 2
n:
1
SEE ELECTRICAL WIRING
SCHEMATIC ON 1 E1.07
2-#4
ELECTRICAL WIRING SCHEMATIC
S
PSE PROVIDED
SECONDARYJB
4 --X----04
1 ❑
METRO TECH PYLON ITS TEL
=:!*-mq= 1.06-flam 0 =_
WIRING SCHEDULE
RUN NO.
�X
CONDUIT SIZE
SHELTER LIGHTS
I
TECH
I PYLON
GROUND
SERVICE
PULL TAPE
REMARKS
1
2" RGS METRO SERVICE
244
2
2" RGS METRO ELEC.
#12-3TC
248
#8G
3
3/4" RGS METRO ELEC.
#12-3TC
LABEL CONDUCTORS WITH
"SHELTER LIGHTS"
4
1" RGS METRO ELEC.
248
#8G
LABEL CONDUCTORS WITH "TECH
PYLON"
5
1.5" PVC METRO ITS.
1
SPARE
6
2" PVC METRO ITS.
1
SPARE
7
PER PSE
PER PSE
PROVIDED BY PSE
0
PSE PROVIDED SECONDARY
SECONDARY JB
DESIGNED: APPROVED:
AD -READY SUBMITTAL 7 INAL
GZ A KING G FRANCO
(425) 453-5000Y of was �`�r•� DRAWN:
1 100 112TH AVE NE, SUITE 500 •�. 41 kj��
,oacobsBELLEVUE, WA 98004 91
$ 3 S. XIA
CHECKED: PROJECT NO:
o CISTEg X.ZHANG E00566E18
concord ���`SIONAL �1� CHECKED: CONTRACT NO:
No. REVISION BY APP D DATE ENGINEERING , w 6/12/2024
K. CHANG YUEN CXXXXXXXX
0
PER PSE
EX. PSE SERVICE POLE
POLE #316392-166291
TR
X
0
m
OB STATION
PANEL: #
VOLTAGE RATING: 120 VOLTS, 1 PHASE, 2 WIRE
BUS RATING: 100 AMPS
MAIN BREAKER: 60 AMPS
FEED: BOTTOM
FAULT CURRENT: 9,300 AMPS
INTERRUPTING CAPACITY: 22,000 AMPS
CIRCUIT DESCRIPTION
VA
CKT
BRKR
TECH PYLON
203
1
1/20
SHELTER LIGHTS
154
2
1/20
SPACE
3
SPACE
4
SPACE
5
SPACE
6
GFCI
180
7
1/20
CONNECTED LOAD = (203+154+180) = 537 VA = 4.475 AMPS AVERAGE
CONTINUOUS LOAD = ((203+154)*1.25+180) = 626 VA =
5.219 AMPS AVERAGE
LIM King County
METRO
GENERAL NOTES
1. PSE WILL PROVIDE CONDUIT(S) FROM THE PRIMARY SERVICE POINT
TO A SECONDARY SERVICE JUNCTION BOX FOR STATION SERVICE
CONNECTIONS PRIOR TO I LINE RAPIDRIDE CONSTRUCTION.
2. HAND DIGGING OR EXCAVATION BY VACTOR MAY BE REQUIRED FOR
CONDUIT INSTALLATION IN AREAS WHERE EXISTING UNDERGROUND
UTILITIES AND/OR TREE ROOTS ARE PRESENT.
3. INSTALL SPARE CONNECTIONS FOR FUTURE METRO FIBER OPTIC
COMMUNICATION TO THE STATION.
4. SEE 1S1.26 FOR STATION PLANS AND AMENITIES DETAILS.
CONSTRUCTION NOTES
1O TRENCH AND INSTALL CONDUIT. ADJUST ROUTING OF TRENCH
AND CONDUIT TO AVOID UTILITIES.
O3 PROVIDE AND INSTALL 60A, 120V METRO NON -METERED ELECTRICAL
SERVICE PEDESTAL. SEE 1 E2.01 FOR MOUNTING AND FOUNDATION
DETAIL. THE FRONT DOOR OF THE CABINET SHALL BE ORIENTED AS
SHOWN BY "F" ON THE PLANS.
4O PROVIDE AND INSTALL WSDOT TYPE 2 JUNCTION BOX PER WSDOT
STANDARD PLAN J-40.10-04. LABEL JUNCTION BOX "METRO".
OSERVICE POINT. COORDINATE WITH PSE ELECTRICAL SERVICE
REPRESENTATIVE FOR CONNECTION TO THE SECONDARY SERVICE
JUNCTION BOX (SR# TO BE ISSUED AT A LATER DATE).
N
0' 10, 20'
DEVELOPMENT ENGINEERING SCALE: 1" - 10'
Michael Sippo 09/11 /2024 T-421418
METRO TRANSIT CAPITAL DIVISION DATE:
RAPIDRIDE I LINE JUNE2024
RENTON SEGMENT DRAWING NO:
ELECTRICAL SITE PLAN 1 E1.08
D# 60323 SHEET NO: OF
302 473