HomeMy WebLinkAboutT-4214062a
0
z
J
W
U
rK
Q
CL
X
a
ui
U
Q
m
z
O
z
W
J
X
z
O
z
W
ry
Ird
0
z
O
z
W
O
X
z
O
z
W
ry
r'
0
z
O
z
W
ry
0
J
X
a
O
0-
0
FT
X
a
0
ry
m
N
N
C2
z
O
z
W
J
W
X
a
z
O
z
W
J
Q
z
X
z
O
z
W
z
O
X
a
z
O
z
W
z
z
Q
U
z
z
O
z
W
o_
X
z
0
J
Q
X
a
0
N
O
N
ry
W
0
ry
O
m
d
U
z Y
a
0
C C
J o O
C
-CUU,
U
w
LU
J N 2
000ox
COco
o�
a N
c� CD z
0 o W
(D
J
X
Cz0w�
a-Q
ox2Ei
11
r
N
O
Imm
LIGHTING GENERAL NOTES
1. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL
FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS).
2. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRADE ONCE CONSTRUCTION IS
COMPLETE.
3. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET
CURRENT ADA STANDARDS (I. E. JUNCTION BOXES SHALL HAVE NON- SKID LIDS).
4. ALL TRANSPORTATION ASSETS THAT ARE TO BE REMOVED AND THEN REINSTALLED AT A LATER DATE DURING
CONSTRUCTION SHALL BE RE - INSTALLED TO CURRENT STANDARDS.
5. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE.
6. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION SYSTEMS ARE SUBJECT
TO INSPECTION BY CITY OF RENTON TRANSPORTATION OPERATIONS MAINTENANCE DEPARTMENT PRIOR TO FINAL
ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION OPERATIONS MAINTENANCE
MANAGER OR OTHER TRANSPORTATION OPERATIONS MAINTENANCE REPRESENTATIVE.
7. MINIMUM GROUND WIRE SIZE SHALL BE # 8. IF CURRENT CARRYING CONDUCTORS ARE LARGER THAN # 8, THE MINIMUM
GROUND WIRE SIZE SHALL MATCH THE LARGEST WIRE SIZE OF THE CURRENT CARRYING CONDUCTORS.
8. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE
HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE.
9. IF THE FIXTURE MANUFACTURER HAS MADE PROVISIONS FOR THE ATTACHMENT OF AGROUND WIRE, A GREEN INSULATED
WIRE OF THE SAME SIZE SHALL RUN FROM THE FIXTURE TO THE GROUND LUG INSIDE THE POLE HANDHOLE. IF THE FIXTURE
MANUFACTURER HAS A GROUND LUG A # 8 GREEN INSULATED WIRE SHALL BE RUN FROM THE FIXTURE GROUND LUG TO
THE POLE GROUND LUG.
10. THE BASIC LUMINAIRE ELECTRICAL WIRING SYSTEM SHALL MEET THE REQUIREMENTS OF CITY OF RENTON STANDARD PLAN
119.
11. THE CONSTRUCTION PLANS DO NOT SHOW ALL UNDERGROUND UTILITIES. THE CONTRACTOR SHALL INVESTIGATE UTILITIES
PRIOR TO ANY FOUNDATION EXCAVATION AND CONDUIT TRENCHING TO AVOID DAMAGE TO ANY UNDERGROUND UTILITIES.
HAND DIGGING MAY BE REQUIRED IN AREAS WHERE EXISTING UNDERGROUND UTILITIES CONFLICT WITH POLE FOUNDATION
INSTALLATION. ALL EXISTING UTILITIES SHALL BE LOCATED AND MARKED IN THE FIELD BEFORE PERFORMING ANY
UNDERGROUND WORK. CARE SHALL BE EXERCISED WHEN EXCAVATING, TRENCHING, OR BORING NEAR ANY EXISTING
UTILITIES. UTILITY COMPANIES SHALL BE CONTACTED THROUGH THE ENGINEER IF PROPOSED CONSTRUCTION CONFLICTS
WITH ANY EXISTING UTILITIES. ALL EXISTING UTILITY INFRASTRUCTURE TO BE PROTECTED AT ALL TIMES THROUGHOUT
CONSTRUCTION.
12. ALL CONDUIT ROUTES SHOWN IN PLANS ARE TO BE FIELD VERIFIED. CONDUIT ROUTES ARE SHOWN SCHEMATICALLY.
13. NEW POLE LOCATIONS SHALL BE APPROVED BY THE ENGINEER BEFORE EXCAVATION WORK BEGINS.
14. EXISTING ROADWAY ILLUMINATION SYSTEMS WITHIN THE PACKAGE LIMITS WILL BE MAINTAINED AND PROTECTED UNLESS
OTHERWISE NOTED ON THESE PLANS.
15. LIGHT POLES IN CITY OF RENTON RIGHT-OF-WAY WILL BE LOCATED ACCORDING TO CITY OF RENTON STANDARD PLANS
117.1, 117.2, 120, AND 124. INSTALLATION OF LIGHT POLES AND JUNCTION BOXES OUTSIDE OF SIDEWALK AREAS SHALL
INCLUDE THE CONCRETE PAD PER CITY OF RENTON STANDARD PLAN 120.
16. EXISTING ILLUMINATION LEVELS SHALL BE MAINTAINED DURING CONSTRUCTION
17. VERIFY WITH CITY OF RENTON SIGNAL TECHNICIANS WHEN CONNECTING TO EXISTING ELECTRICAL SYSTEM TO CONFIRM
INTEGRITY OF SYSTEM AND VIABILITY OF EXISTING CONDUITS AND JUNCTION BOXES.
CONSTRUCTION NOTES
OINSTALL NEW STREET LIGHT POLE AND FOUNDATION WITH NEW LED FIXTURE PER
CITY OF RENTON STANDARD PLAN 117.1.
O2 INSTALL TYPE 2 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.10-04.
OSERVICE POINT. COORDINATE WITH PSE ELECTRICAL SERVICE REPRESENTATIVE
FOR SERVICE CONNECTION (SR# TO BE ISSUED AT A LATER DATE).
O4 REMOVE EXISTING STREET LIGHT POLE, FOUNDATION, BRACKET ARM, LUMINAIRE
AND ASSOCIATED WIRING AND RETURN EXISTING LIGHT TO CITY OF RENTON
SIGNAL SHOP.
TINSTALL TYPE 8 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.30-04.
OSERVICE CABINET. SEE SIGNAL DRAWINGS FOR DETAILS.
O7 INSTALL NEW STREET LIGHT POLE AND FOUNDATION WITH STREET AND
PEDESTRIAN COMBO LIGHT PER CITY OF RENTON STANDARD PLAN 117.1.
O8 INSTALL PEDESTRIAN SCALE LUMINAIRE POLE AND FOUNDATION WITH NEW LED
FIXTURE PER CITY OF RENTON STANDARD PLAN 117.2.
OINSTALL NEW CONDUITS INTO EXISTING JUNCTION BOX.
10 SPLICE NEW LIGHTING CONDUCTORS WITH EXISTING LIGHTING CONDUCTORS IN
JUNCTION BOX TO REFEED THE EXISTING TWO STREET LIGHTS TO THE WEST ON S
GRADY WAY.
1 1 INSTALL CONDUIT INTO PSE PROVIDED SECONDARY JUNCTION BOX.
12 SERVICE CABINET. SEE 11-2.08 FOR SERVICE PANEL DETAILS.
13 BORE AND INSTALL CONDUIT. ADJUST BORE TO AVOID UTILITIES AS NEEDED
RESTORE AREA DISTURBED BY CORING OPERATIONS BACK TO
PRECONSTRUCTION CONDITION.
14 INSTALL CONDUIT INTO SIGNAL JUNCTION BOX. SEE SIGNAL DRAWINGS FOR
DETAILS.
15 REPLACE EXISTING LUMINAIRE ON EXISTING PSE WOOD POLE (BY OTHERS).
16 INTERCEPT EXISTING CONDUIT AND EXTEND TO NEW JUNCTION BOX.
17 SERVICE POINT. SEE ELECTRICAL DRAWINGS FOR DETAILS.
CONSTRUCTION NOTES (CONT.)
18 SOLAR LIGHT ON SIGN POST (BY OTHERS). SEE 1 L2.09 FOR DETAILS.
19 INSTALL 4-2" PVC RISER ON NEW PSE WOOD POLE (BY OTHERS).
20 PROTECT IN PLACE EXISTING PRIVATE (ARCO) LIGHT POLE.
21 REMOVE EXISTING PRIVATE (TESLA) LIGHT POLE, FOUNDATION, BRACKET ARM,
LUMINAIRE AND ASSOCIATED WIRING (BY OTHERS).
22 REMOVE EXISTING PRIVATE (ARCO) LIGHT POLE, FOUNDATION, BRACKET ARM,
LUMINAIRE AND ASSOCIATED WIRING (BY OTHERS).
23 PROTECT IN PLACE EXISTING PRIVATE (TESLA) LIGHT POLE.
24 PROTECT IN PLACE EXISTING PRIVATE (RENTON VILLAGE) LIGHT POLE.
25 PROTECT IN PLACE EXISTING STREET LIGHT POLE.
26 REMOVE EXISTING JUNCTION BOX AND ABANDON EXISTING CONDUIT IN PLACE.
27 REMOVE EXISTING SERVICE CABINET.
28 REMOVE EXISTING JUNCTION BOX.
29 DISCONNECT EXISTING LIGHTING CONDUCTORS IN BASE OF POLE AND PULL BACK
CONDUCTORS WEST TO NEAREST JUNCTION BOX.
30 DISCONNECT EXISTING LIGHTING CONDUCTORS IN BASE OF POLE AND PULL BACK
CONDUCTORS EAST TO NEAREST JUNCTION BOX.
31 DISCONNECT EXISTING LIGHTING CONDUCTORS IN BASE OF POLE AND PULL BACK
CONDUCTORS FROM THE WEST AND SOUTH TO NEAREST JUNCTION BOX.
32 INSTALL CONCRETE PAD PER CITY OF RENTON STANDARD PLAN 120.
33 INSTALL LUMINAIRE ON NEW SIGNAL MAST ARM POLE PER CITY OF RENTON
STANDARD PLAN 140. SEE SIGNAL DRAWINGS FOR DETAILS.
34 RELOCATE EXISTING LUMINAIRE MOUNTED TO EXISTING SIGNAL MAST ARM POLE.
SEE SIGNAL DRAWINGS FOR DETAILS.
35 INSTALL NEW LUMINAIRE ON NEW PSE WOOD POLE (BY OTHERS).
36 EXISTING SERVICE CABINET.
37 INSTALL CONCRETE PAD EXTENDING 1 FT FROM THE EDGE OF THE POLE BASE.
38 INSTALL CONCRETE PAD EXTENDING 1 FT FROM THE EDGE OF THE JUNCTION BOX.
39 INSTALL LUMINAIRE ON NEW HAWK SIGNAL MAST ARM POLE PER CITY OF RENTON
STANDARD PLAN 138.3. SEE SIGNAL DRAWINGS FOR DETAILS.
40 SEE ITS PLAN FOR JUNCTION BOX REMOVAL.
41 SPLICE NEW LIGHTING CONDUCTORS WITH EXISTING LIGHTING CONDUCTORS
IN JUNCTION BOX TO REFEED THE EXISTING TWO STREET LIGHTS TO THE EAST
ON S GRADY WAY.
42 SPLICE NEW LIGHTING CONDUCTORS WITH EXISTING LIGHTING CONDUCTORS
IN JUNCTION BOX TO REFEED THE EXISTING TWO STREET LIGHTS TO THE
NORTH ON TALBOT RD S.
43 PULL BACK EXISTING LIGHTING CONDUCTORS TO EXISTING JUNCTION BOX AND
INSTALL THROUGH EXISTING AND NEW CONDUIT.
44 INSTALL GRIDSMART VIDEO DETECTION CAMERA ON LUMINAIRE BRACKET ARM.
SEE SIGNAL DRAWINGS FOR DETAILS.
LEGEND:
EXISTING PROPOSED
0_ coo
0
0
JB ❑ aoO
I
DESCRIPTION
ROADWAY LUMINAIRE, BRACKET ARM
POLE, AND FOUNDATION
SIGNAL LUMINAIRE AND BRACKET ARM
(LENGTH VARIES)
PSE LUMINAIRE AND BRACKET ARM
EXISTING PSE LUMINAIRE REPLACEMENT
PEDESTRIAN LUMINAIRE, POLE,
AND FOUNDATION
JUNCTION BOX -TYPE 1, 2/4, 3/8
CONDUIT
SERVICE CABINET
LUMINAIRE POLE NUMBER
CONSTRUCTION NOTE
WIRE NOTE
DEVELOPMENT ENGINEERING
Michael Sippo 09/11 /2024
F-T-421462
DESIGNED: APPROVED: METRO TRANSIT CAPITAL DIVISION DATE. JUNE 2024
AD -READY SUBMITTAL ----.
yING ZRAP I D R I D E I LINE
� A. KING G. FRANCO
(425) 453-5000 Wqg DRAWN:
1 100 112TH AVE NE, SUITE 500 w °F h'r� Gl ; •
,JacobsBELLEVUE, WA 98004 ti� ��' King County
y S. XIA 14
CHECKED: PROJECT N0: RENTON SEGMENT DRAWING N0:
ISTMETRO 1L1.N1
f• � .� 40234 9 � K.NORBERG E00566E18 LIGHTING GENERAL NOTES, � � '�GI STEg� �'' �
concord ��S`SIONAL�1� CHECKED: CONTRACT NO: SHEET NO OF
No. REVISION BY APP'D DATE►...�� CONSTRUCTION NOTES AND LEGEND
ENGINEERING 6/12/2024 K. CHANG YUEN CXXXXXXXX 346 473