HomeMy WebLinkAboutT-4214064a
0
z
J
W
U
rK
70
X
W
U)
Q
m
z
O
z
W
J
X
a
z
O
z
W
ry
79
0
a
z
O
z
w
O
x
a
z
O
z
w
ry
r'
0
x
3
z
O
z
w
ry
0
J
x
a
O
0-
0
FT
x
a
0
ry
m
N
N
C2
z
O
z
W
J
W
X
a
z
O
z
W
J
Q
z
X
z
O
z
w
z
O
x
a
Z
O
z
w
Of
z
z
Q
U
z
x
a
z
O
z
w
x
a
z
0
J
Q
x
0
N
O
N
r'
W
0
r'
O
00
H
U
o Y
J
a
0
C C
J o O
C
-CUU,
U
Qw
J � _
000ox
co o�
a N
c� CD Z
0 o W
o O
w
J
X
Cz ~ W U
oa-x2Ei
C
d-
LL1
z
J
Cn
WIRING SCHEDULE
RUN NO.
X
CONDUIT SIZE
EXISTING CONDUCTORS
STREET LIGHTING
PEDESTRIAN LIGHTING
GROUND
REMARKS
4
2" PVC
246
146
8
2" PVC
246
246
146
2" PVC
SPARE
10
2" PVC
446
146
2" PVC
SPARE
16
2" PVC
246
446
146
2" PVC
SPARE
24
3" HDPE
446
146
3" HDPE
SPARE
33
EX 2"
4-#6**
146
**REINSTALL
GENERAL NOTES
1. SEE SHEET 1L1.N1 FOR STREET LIGHTING GENERAL NOTES.
2. SEE SIGNAL DRAWINGS FOR ADDITIONAL CONDUIT, AND WIRING AT THE
INTERSECTIONS.
3. SEE SHEET 1L2.01 FOR WIRING SCHEMATICS.
4. SEE SHEET 1 L2.05, 1 L2.06, AND 1 L2.07 FOR POLE SCHEDULES.
5. SEE SIGNAL DRAWINGS FOR LUMINAIRES ON SIGNAL MAST ARM POLES.
6. MAINTAIN CLEARANCE FROM PSE OVERHEAD TRANSMISSION LINES.
CONSTRUCTION NOTES
O2 INSTALL TYPE 2 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.10-04.
O4 REMOVE EXISTING STREET LIGHT POLE, FOUNDATION, BRACKET ARM,
LUMINAIRE AND ASSOCIATED WIRING AND RETURN EXISTING LIGHT TO
CITY OF RENTON SIGNAL SHOP.
O5 INSTALL TYPE 8 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.30-04.
OSERVICE CABINET. SEE SIGNAL DRAWINGS FOR DETAILS.
O8 INSTALL PEDESTRIAN SCALE LUMINAIRE POLE AND FOUNDATION WITH
NEW LED FIXTURE PER CITY OF RENTON STANDARD PLAN 117.2.
13 BORE AND INSTALL CONDUIT. ADJUST BORE TO AVOID UTILITIES AS
NEEDED. RESTORE AREA DISTURBED BY CORING OPERATIONS
BACK TO PRECONSTRUCTION CONDITION.
21 REMOVE EXISTING PRIVATE (TESLA) LIGHT POLE, FOUNDATION, BRACKE
ARM, LUMINAIRE AND ASSOCIATED WIRING (BY OTHERS).
23 PROTECT IN PLACE EXISTING PRIVATE (TESLA) LIGHT POLE.
25 PROTECT IN PLACE EXISTING STREET LIGHT POLE.
SPROTECT IN PLACE EXISTING PRIVATE (RENTON VILLAGE) LIGHT POLE.
26 REMOVE EXISTING JUNCTION BOX AND ABANDON EXISTING CONDUIT IN
PLACE.
27 REMOVE EXISTING SERVICE CABINET.
32 INSTALL CONCRETE PAD PER CITY OF RENTON STANDARD PLAN 120.
33 INSTALL LUMINAIRE ON NEW SIGNAL MAST ARM POLE PER CITY OF REN
STANDARD PLAN 140. SEE SIGNAL DRAWINGS FOR DETAILS.
37
INSTALL CONCRETE PAD EXTENDING 1 FT FROM THE EDGE OF THE POLE
BASE.
38
INSTALL CONCRETE PAD EXTENDING 1 FT FROM THE EDGE OF THE
JUNCTION BOX.
7
40
SEE ITS PLAN FOR JUNCTION BOX REMOVAL.
J
=
43
PULL BACK EXISTING LIGHTING CONDUCTORS TO EXISTING JUNCTION
U
BOX AND INSTALL THROUGH EXISTING AND NEW CONDUIT.
Q
44
O
INSTALL GRIDSMART VIDEO DETECTION CAMERA ON LUMINAIRE
BRACKET ARK/I. SEE SIGNAL DRAWINGS FOR DETAILS.
CONDITION OF APPROVAL #8:
ITERIS APEX VECTOR
(4-WAY) VIDEO DETECTION
SYSTEM IS REQUIRED FOR ALL
/ VIDEO DETECTION ON THE
PROJECT IN LIEU OF
GRIDSMART VIDEO DETECTION
CAMERAS. UPDATE PROJECT
SPECIFICATIONS.
DEVELOPMENT ENGINEERING
Michael Sippo 09/11/2024
SCALE: 1" = 20'
T-421464
AD -READY SUBMITTAL -
DESIGNED: APPROVED: METRO TRANSIT CAPITAL DIVISION DATE. JUNE 2024
---.
yING Z� A. KING G. FRANCO RAP I D R I D E I LINE
(425) 453-5000 WAS DRAWN:
1 100 112TH AVE NE, SUITE 500 w °F h'r� Gl ; cob BELLE - UE, WA 98004 �� S. XIA King County
�` CHECKED: PROJECT NO: RENTON SEGMENT DRAWING NO:
E� .p 40234 9 K. NORBERG E00566E18 METRO LIGHTING PLAN 1 L 1.02
� O '�GI STEg�'' �
concord
No. REVISION BY APP'D DATE � S`SI:N==� i� CHECKED: CONTRACT NO:
'�► •� G RA 14+00 TO G RA 19+00 SHEET N0 OF
tA ENGINEERING 6/12/2024 K. CHANG YUEN icxxxxxxxx 1 1 348 473
00
N
Irm
O
N
V
0
N
O
O
O
N
N
a
J