HomeMy WebLinkAboutT-4214073z
O
z
w
ry
I
U)
_.
GENERAL NOTES
0)
z
O
z
w
ry
0
Of
X
a
z
O
z
W
I
J
x
a
O
LL
z
J
W
U
ry
Q
Y
N
N
O
0-
0
x
z
O
z
w
I
J
W
x
z
O
z
w
Of
J
Q
z
0
x
3
z
O
z
w
ry
0
x
a
O
U
W
W
x
z
O
z
W
ry
I
z
O
Q
C9
X
c
0
c
0
ry
CO
00
o'
N
N
C2
Z
O
z
w
ry
Z
Z
Q
_
U
Z
x
3
Z
O
71
z
w
ry
a
x
3
Z
0
J
Q
_�A
a
0
Y N
o O
CZ o
J (6 ry
ca w
m r'
O
oE00
00
J � �
000co
o Y
o o�
CD CV
:�� Z
0 o W
o : (LLD,
w
J
0 ~ W LU
(D
oa-x2Ei
WIRING SCHEDULE
RUN NO.
ZL
CONDUIT
SIZE
EXISTING
CONDUCTORS
STREET LIGHTING
PEDESTRIAN
LIGHTING
GROUND
SERVICE
REMARKS
2" PVC
246
146
1
2" PVC
STUBOUT 1' FROM EDGE OF CONCRETE FOUNDATION, CAP FOR FUTURE USE
4
2" PVC
246
146
2" PVC
446
146
10
2" PVC
SPARE
2" PVC
246
146
11
2" PVC
SPARE
2" PVC
246
446
146
16
2" PVC
SPARE
3" PVC
246
446
146
25
3" PVC
SPARE
2" PVC
446
446
146
26
2" PVC
SEE SIGNAL PLAN FOR ADDITIONAL CONDUCTORS
DESIGNED: APPROVED:
AD -READY SUBMITTAL 7 LNG Z A. KING G. FRANCO
(425) 453-5000 Y WAS DRAWN:
cob1 100 112TH AVE NE, SUITE 500 w °F •
BELLEVUE, WA 98004 tr tiv ��' . King County
y 0 S. XIA LQ 1p CHECKED: PROJECT NO:
Ei
� 40?;i4 9
O �GISTEg�'� K. NORBERG E00566E18 METRO
No. REVISION BY APP'D DATE concord ���`S,:N==�� CHECKED: CONTRACT NO:
E N G I N E E R I N G 6/12/2024 K. CHANG YUEN CXXXXXXXX
1. SEE SHEET 1L1.N1 FOR STREET LIGHTING GENERAL NOTES.
2. SEE STATION ELECTRICAL DRAWINGS FOR ADDITIONAL CONDUIT, AND WIRING
DETAILS AT BUS STATION.
3. SEE SHEET 1 L2.03 FOR WIRING SCHEMATICS.
4. SEE SHEET 1 L2.05 TO 1 L2.07 FOR POLE SCHEDULES.
CONSTRUCTION NOTES
OINSTALL NEW STREET LIGHT POLE AND FOUNDATION WITH NEW LED FIXTURE
PER CITY OF RENTON STANDARD PLAN 117.1. SPLICE STREET LIGHTING
CONDUCTORS TO POLE AND BRACKET CABLE PER CITY OF RENTON STANDARD
PLAN 119.
OINSTALL
TYPE 2 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.10-04.
OSERVICE
POINT. COORDINATE WITH PSE ELECTRICAL SERVICE
REPRESENTATIVE FOR SERVICE CONNECTION (SR# TO BE ISSUED AT A LATER
DATE).
N
OINSTALL
TYPE 8 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.30-04.
r
O
O
O
INSTALL PEDESTRIAN SCALE LUMINAIRE POLE AND FOUNDATION PER CITY
r
OF RENTON STANDARD PLAN 117.2. SPLICE PEDESTRIAN LIGHTING
N
CONDUCTORS TO POLE AND BRACKET CABLE IN HANDHOLE.
V
12
SERVICE CABINET. SEE 11-2.08 FOR SERVICE PANEL DETAILS.
13
BORE AND INSTALL CONDUIT. ADJUST BORE TO AVOID UTILITIES AS NEEDED.
RESTORE AREA DISTURBED BY CORING OPERATIONS BACK TO
N
PRECONSTRUCTION CONDITION.
M
15
REPLACE EXISTING LUMINAIRE ON EXISTING PSE WOOD POLE (BY OTHERS).
r
O
O
O
S
INTERCEPT EXISTING CONDUIT AND EXTEND TO NEW JUNCTION BOX.
1
r
N
18
SOLAR LIGHT ON SIGN POST (BY OTHERS). SEE 1 L2.09 FOR DETAILS.
a
19
INSTALL 4-2" PVC RISER ON NEW PSE WOOD POLE (BY OTHERS).
28
REMOVE EXISTING JUNCTION BOX.
O
32
INSTALL CONCRETE PAD PER CITY OF RENTON STANDARD PLAN 120.
N
O
O37
INSTALL CONCRETE PAD EXTENDING 1 FT FROM THE EDGE OF THE POLE BASE.
0
38
INSTALL CONCRETE PAD EXTENDING 1 FT FROM THE EDGE OF THE JUNCTION
1
N
N
BOX.
a
L
�7
0' 20' 40'
DEVELOPMENT ENGINEERING �' IL I
Michael Sippo 09/11 /2024 %J0 SCALE: 1" = 20'
T-421473
METRO TRANSIT CAPITAL DIVISION DATE:
RAPIDRIDE I LINE JUNE2024
RENTON SEGMENT DRAWING NO:
LIGHTING PLAN 1 L1.10
TAL-21 71 +00 TO TAL-21 76+00 SHEET NO: OF
357 473