HomeMy WebLinkAboutT-4214076z
O
z
w
ry
I
U)
x
z N
0
z
z
w 1
o I`
IL—r
z
W
I
J
X
a
0
z
J
W
U
Q
x
Y
N
N
02
O
0-
0
FT
X
z
0
z
W
Df I
J
W
X
z
0
z
w
Q
z
X
z
0
z
w
ry
0
x
a
0
U
W
W
X
z
O
z
W
ry
I
z
0
C9
X
c
0
ry
I
CO
m
N
N
C2
z
O
z
w
ry
z
z
Q
U
z
X
i�
z
0
71
z
w
ry
a
X
i�
3
Z
0
J
Q
Cl) x
J
a
O
Y N
a=o
co 0
J (6 ry
ca w
m r'
O
oE00
�o
J � �
� 66
U
000co
o Y
CO o�
CD CV
: 0 o W
o Uw
J
0 ~ W LU
U'
oa-x2Ei
0
EX. ROW
Jll
WIRING SCHEDULE
RUN NO.
ZL
CONDUIT SIZE
EXISTING
CONDUCTORS
STREET LIGHTING
PEDESTRIAN
LIGHTING
GROUND
REMARKS
2" PVC
246
146
1
2" PVC
STUBOUT 1' FROM EDGE OF CONCRETE FOUNDATION, CAP FOR FUTURE USE
2" PVC
446
146
3
2" PVC
SPARE
4
2" PVC
246
146
2" PVC
446
446
146
7
2" PVC
SPARE
2" PVC
446
146
10
2" PVC
SPARE
2" PVC
246
146
11
2" PVC
SPARE
3" HDPE
246
146
21
3" HDPE
SPARE
35
EX 2"
2-#6**
146
**REINSTALL
36
2" PVC
2-#6**
146
**REINSTALL
322305-9040
STATION 60321 (IB)
TIER 1 33 85
M6O8
ITS
am
S _
AA�nn
----- ---- --F� --
43+00 -------
- STATION 59391 (OB) 10
_ —'- --- TIER 1
38 5
s i
1
u
C
s,8
8 62
25 91
EX. ROW 4 SS
s s CO
322305-9299
in
45-00
i
T
61 1 32
GENERAL NOTES
1. SEE SHEET 1L1.N1 FOR STREET LIGHTING GENERAL NOTES.
2. SEE SHEET 11-2.03 FOR WIRING SCHEMATICS.
4. SEE SHEET 1 L2.05 TO 1 L2.07 FOR POLE SCHEDULES.
CONSTRUCTION NOTES
OINSTALL NEW STREET LIGHT POLE AND FOUNDATION WITH NEW LED FIXTURE PER
CITY OF RENTON STANDARD PLAN 117.1.SPLICE STREET LIGHTING CONDUCTORS
TO POLE AND BRACKET CABLE PER CITY OF RENTON STANDARD PLAN 119.
O2 INSTALL TYPE 2 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.10-04.
O4 REMOVE EXISTING STREET LIGHT POLE, FOUNDATION, BRACKET ARM, LUMINAIRE AND
ASSOCIATED WIRING AND RETURN EXISTING LIGHT TO CITY OF RENTON SIGNAL SHOP.
OINSTALL TYPE 8 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.30-04.
OSERVICE CABINET. SEE SIGNAL DRAWINGS FOR DETAILS.
O8 INSTALL PEDESTRIAN SCALE LUMINAIRE POLE AND FOUNDATION WITH NEW LED
FIXTURE PER CITY OF RENTON STANDARD PLAN 117.2. SPLICE PEDESTRIAN
LIGHTING CONDUCTORS TO POLE AND BRACKET CABLE IN HANDHOLE.
13 BORE AND INSTALL CONDUIT. ADJUST BORE TO AVOID UTILITIES AS NEEDED. RESTORE
AREA DISTURBED BY CORING OPERATIONS BACK TO PRECONSTRUCTION CONDITION.
16
INTERCEPT EXISTING CONDUIT AND EXTEND TO NEW JUNCTION BOX.
25
PROTECT IN PLACE EXISTING STREET LIGHT POLE.
28
REMOVE EXISTING JUNCTION BOX.
86 33 i
31
DISCONNECT EXISTING LIGHTING CONDUCTORS IN BASE OF POLE AND PULL BACK
is
CONDUCTORS FROM THE WEST AND SOUTH TO NEAREST JUNCTION BOX.
/
O
bhp
32
INSTALL CONCRETE PAD PER CITY OF RENTON STANDARD PLAN 120.
yp
33
INSTALL LUMINAIRE ON NEW SIGNAL MAST ARM POLE PER CITY OF RENTON
' O
STANDARD PLAN 140. SEE SIGNAL DRAWINGS FOR DETAILS.
0
38
O
INSTALL CONCRETE PAD EXTENDING 1 FT FROM THE EDGE OF THE JUNCTION BOX.
44
INSTALL GRIDkMART VIDEO DETECTIONC CAMERA ON LUMINAIRE BRACKET ARM.
SEE SIGNAL DR GS FOR DETAILS.
46+00
'
® S E �—
CARR RD
O
47+00
(CAR -LINE)
O
CONDITION OF APPROVAL #8:
--
ITERIS APEX VECTOR
— —
(4-WAY) VIDEO DETECTION
DESIGNED: APPROVED:
AD -READY SUBMITTAL 7 LNG Z A. KING G. FRANCO
(425) 453-5000 Y Wqg � DRAWN:
1 100 112TH AVE NE, SUITE 500 �w °F h'r,�� Gl ;
BELLEVUE, WA 98004 fT ►.
rn S. XIA
CHECKED: PROJECT NO:
Ei
� 40?;i4 9
O �GISTEg�'� K. NORBERG E00566E18
No. REVISION BY APP'D DATE concord ���`S,:N==�� CHECKED: CONTRACT NO:
E N G I N E E R I N G 6/12/2024 K. CHANG YUEN icxxxxxxxx
King County
METRO
SYSTEM IS REQUIRED FOR ALL
VIDEO DETECTION ON THE
PROJECT IN LIEU OF
GRIDSMART VIDEO DETECTION
CAMERAS. UPDATE PROJECT
SPECIFICATIONS.
0' 20' 40'
DEVELOPMENT ENGINEERING
Michael Sippo 09/11 /2024
SCALE: 1" = 20'
T-421476
METRO TRANSIT CAPITAL DIVISION DATE:
RAPIDRIDE I LINE JUNE2024
RENTON SEGMENT DRAWING NO:
LIGHTING PLAN 1 L1.13
CAR 42+50 TO CAR 47+50 SHEET NO: OF
360 473