CONSTRUCTION NOTES:
0FURNISH AND INSTALL TYPE I SIGNAL POLE PER WSDOT STANDARD PLAN J-20.11
AND DETAIL 1TS1.07D. FURNISH AND INSTALL ONE 3-SECTION SIGNAL HEAD, ONE
PEDESTRIAN SIGNAL HEAD AND ONE APS PEDESTRIAN PUSH BUTTON WITH SIGN ON
SIGNAL POLE.
®2 CONSTRUCT FOUNDATION PER SIGNAL POLE CHART 1TS1.07D AND COR STD. PLANS
139 AND 140. TOP OF FOUNDATION SHALL BE FLUSH WITH GRADE. FURNISH AND
INSTALL TYPE III SIGNAL POLE WITH 35MAST ARM. FURNISH AND INSTALL THREE
3-SECTION SIGNAL HEADS, ONE EMERGENCY PRE-EMPTION DETECTOR AND ONE
D3-103 SIGN ON MAST ARM. FURNISH AND INSTALL TERMINAL CABINET ON SIGNAL
POLE. REFER TO LIGHTING PLANS FOR LUMINAIRE AND LUMINAIRE BRACKET ARM.
®3 CONSTRUCT FOUNDATION PER SIGNAL POLE CHART 1TS1.07D AND COR STD. PLANS
139 AND 140. TOP OF FOUNDATION SHALL BE FLUSH WITH GRADE. FURNISH AND
INSTALL TYPE 11 SIGNAL POLE WITH 35MAST ARM. FURNISH AND INSTALL TWO
3-SECTION SIGNAL HEADS, ONE 3-SECTION SIGNAL HEAD WITH SPECIAL "BUS ONLY"
SIGN, ONE SPECIAL "(ARROW) BUS ONLY" SIGN, ONE R3-5R SIGN, ONE R3-1
BLANK -OUT SIGN, ONE EMERGENCY PRE-EMPTION DETECTOR AND ONE D3-103 SIGN
ON MAST ARM. FURNISH AND INSTALL ONE PEDESTRIAN SIGNAL HEAD, ONE PTZ
CAMERA AND MOUNTING BRACKET, AND TERMINAL CABINET ON SIGNAL POLE.
FURNISH AND INSTALL TYPE PPB SIGNAL POST PER WSDOT STANDARD PLAN J-20.11
3A AND DETAIL 1TS1.07D. FURNISH AND INSTALL ONE APS PEDESTRIAN PUSH BUTTON
WITH SIGN ON SIGNAL POLE.
0 CONSTRUCT FOUNDATION PER SIGNAL POLE CHART 1TS1.07D AND COR STD. PLANS 139 AND 140. TOP
OF FOUNDATION SHALL BE FLUSH WITH GRADE. FURNISH AND INSTALL TYPE III SIGNAL POLE WITH 3'
ROUND FOUNDATION AND WITH 40' MAST ARM. FURNISH AND INSTALL TWO 3-SECTION SIGNAL HEADS,
ONE EMERGENCY PRE-EMPTION DETECTOR, ONE ADVANCE VEHICLE DETECTOR AND MOUNTING
BRACKET, AND ONE D3-103 SIGN ON THE MAST ARM. FURNISH AND INSTALL ONE PEDESTRIAN SIGNAL
HEAD AND TERMINAL CABINET ON SIGNAL POLE. FURNISH AND INSTALL ONE BELL CAMERA AND
MOUNTING BRACKET ON LUMINAIRE ARM. REFER TO LIGHTING PLANS FOR LUMINAIRE AND LUMINAIRE
BRACKET ARM.
4A FURNISH AND INSTALL TYPE PS SIGNAL POLE PER WSDOT STANDARD PLAN J-20.16 AND DETAIL
1TS1.07D. FURNISH AND INSTALL ONE PEDESTRIAN SIGNAL HEAD AND ONE APS PEDESTRIAN PUSH
BUTTON WITH SIGN ON SIGNAL POLE.
4B FURNISH AND INSTALL TYPE PPB SIGNAL POST PER WSDOT STANDARD PLAN J-20.11 AND DETAIL 1TS1.07D.
FURNISH AND INSTALL ONE APS PEDESTRIAN PUSH BUTTON WITH SIGN ON SIGNAL POLE.
OFURNISH AND INSTALL A NEW TYPE 8 JUNCTION BOX PER WSDOT STD. PLAN J-40.30.
OCONSTRUCT JOINT CONTROLLER/SERVICE CABINET FOUNDATION PER CITY OF RENTON STANDARD
PLANS 126.1 AND 126.2. INSTALL CONTROLLER EQUIPMENT AND CONNECT FIELD WIRING. VERIFY FINAL
LOCATION WITH THE ENGINEER IN THE FIELD PRIOR TO POURING THE FOUNDATION.
OPROGRAM DETECTION SOFTWARE SO THAT DETECTION ZONES V31 AND V32 MUST BOTH RECEIVE A
CALL SIMULTANEOUSLY TO ACTIVATE BUS PHASE 3.
OINSTALL CONDUIT UNDER ROADWAY USING APPROVED DIRECTIONAL BORING METHOD.
II
SD - -
0
0~
2
� I
�p,RR I
ss _ _L1NE� v61
�s ICAR -
- r
SD
SD
43+00 W
I —
Ss
C
SS
�S
SD
D
so
So
S
�Q
T
SS
SSCO
1, I0�
o/1
r
3A =
Dnr�
1
OFURNISH AND INSTALL A NEW TYPE 2 JUNCTION BOX PER WSDOT STD. PLAN J-40.10.
10 FURNISH AND INSTALL A NEW PULL BOX PER WSDOT STD. PLAN J-90.10-03.
11 INSTALLATION OF SCOOT MODULE AND AN ADDITIONAL LICENSE IS NECESSARY.
PROVIDE SCOOT SYSTEM DETECTORS LAYOUT PER MANUFACTURER'S
RECOMMENDATIONS FOR CITY OF RENTON VERIFICATION. NEW INSTALLATION
INCLUDES INTERSECTION SET UP/ CONFIGURATION/ PROGRAMMING IN TACTICS
(SIGNAL MANAGEMENT SYSTEM) AND SCOOT (ADAPTIVE SYSTEM) BY VENDOR IS
REQUIRED. CITY OF RENTON DOES NOT SET UP OR CONFIGURE NEW SCOOT SIGNAL.
VENDOR TO COORDINATE WITH TRANSPORTATION MAINTENANCE MANAGER FOR
INSTALLATION. SCOOT INTERSECTION DISPLAY MAP SHALL BE CREATED IN CITY OF
RENTON SCOOT SYSTEM. SCOOT AREA MAP SHALL BE UPDATED TO SHOW THIS NEW
SIGNAL ON THE CORRIDOR. THE SCOOT INTERSECTION NODE ARCHITECTURE
DIAGRAM AND DATABASE DESIGN DIAGRAM SHALL BE PROVIDED TO CITY OF
RENTON PUBLIC WORKS TRANSPORTATION OPERATIONS.
12 PROCURE AND INSTALL THE GRIDSMART DETECTION SYSTEM INCLUDING THE
PERFORMANCE PLUS DATA LICENSE PER MANUFACTURER'S (GRIDSMART)
RECOMMENDATIONS.
V23
V22 _
V21 46+00
4
/V71 O �4A c� Q '/ 'I
� wEc
7
� oyp
CONDITION OF APPROVAL #8:
ITERIS APEX VECTOR
(4-WAY) VIDEO DETECTION
SYSTEM IS REQUIRED FOR ALL
VIDEO DETECTION ON THE
PROJECT IN LIEU OF
GRIDSMART VIDEO DETECTION
CAMERAS. UPDATE PROJECT
SPECIFICATIONS.
CONDITION OF APPROVAL # 13
PROVIDE SCOOT SYSTEM DETECTORS LAYOUT PER MANUFACTURER'S
HEUUMMENUA 11UNS I-UH L.1 I Y'S VE.HIF IUA 11UN.
NEW INSTALLATION INCLUDES INTERSECTION SET UP/ CONFIGURATION/
PROGRAMMING IN TACTICS (SIGNAL MANAGEMENT SYSTEM) AND SCOOT (ADAPTIVE
_ SYSTEM) BY VENDOR IS REQUIRED. CITY DOES NOT SET UP OR CONFIGURE NEW
SCOOT SIGNAL. VENDOR TO COORDINATE WITH TRANSPORTATION MAINTENANCE
MANAGER FOR INSTALLATION. SCOOT INTERSECTION DISPLAY MAP SHALL BE
CREATED IN CITY'S SCOOT SYSTEM. SCOOT AREA MAP SHALL BE UPDATED TO
SHOW THIS NEW SIGNAL ON THE CORRIDOR.
T
THE SCOOT INTERSECTION NODE ARCHITECTURE DIAGRAM SHALL BE PROVIDED TO
THE CITY'S PW TRANSPORTATION OPERATIONS.
THE SCOOT INTERSECTION DATABASE DESIGN DIAGRAM SHALL BE PROVIDED TO
wt THE CITY'S PW TRANSPORTATION OPERATIONS.
PLEASE VERIFY ALL ADVANCED DETECTION DISTANCES FOR SIGNALS PROPOSING
WITH THE NEW VIDEO DETECTION SYSTEM IF ADVANCED DETECTION CAMERA IS
S — REQUIRED. THE NEW STOPBAR AND ADVANCED VIDEO DETECTION ZONE(S) SHALL
PROVIDE ADEQUATE TRAFFIC DATA TO PERFORM AS THE SCOOT ADAPTIVE SYSTEM
DETECTORS PER MANUFACTURER'S (WESTERN SYSTEMS OR JOE COUPLES)
RECOMMENDATIONS.
0' 20' 40'
DEVELOPMENT ENGINEERING
W IL
Michael Sippo 09/11 /2024 w SCALE: 1" - 40'
T-4214116
AD -READY SUBMITTAL
DESIGNED: APPROVED: METRO TRANSIT CAPITAL DIVISION DATE:
7
J. DOWDS BENNETT G. FRANCO RAP I D RI D E I LINE JUNE 2024
(425) 453-5000 DRAWN:
1100 112TH AVE NE, SUITE 500 Q,�ti �c� co BELLE - UE, WA 98004 1 �� � P. OSUNA King County
/ CHECKED: PROJECT NO: RENTON SEGMENT DRAWING NO:
41141 ti � � R. JAHNS E00566E18MET DETECTION PLAN 1 TS 1.07B
No. REVISION BY APP'D DATE ZONAL CHECKED: CONTRACT NO:
No. REVISION 7SE CARR RD & 105TH PL SE SHEET NO: OF
06/13/2ti K. CHANG YUEN CXXXXXXXX 400 473