Loading...
HomeMy WebLinkAboutS-42140100 r z N w o � X N z 0 L z w J Q z 0 U) N X z 0 z N w aJ X z 0 z w Of I Ly X z O z w C/) ryl X 0 z w 0 w J X a z O z w 0 x 0 N N C2 ry m N N O z O z w ry a z O z w r' 0 X z O z w ry z i O X a a O �I O X 3 Z U' J Q X 3 O N O N o ry I --- w 2 0 r. O CU > Q J � U � Y o �Q w a> rn N O> � Co col co E 70 0-4 CD N � w NI O C�) 04 X CD iZ� CD CV O a � � Y 0 o � X 3: w U) �'� w w Q U a_ X 2Ei E)B 2118R1 M 124.98, MP RCP SU 2p.3 0 z 73 — OHP — OHP- IC(NE 21.3)- 1E )-21.2 RC P / P 1I 0F SED12"RCP 9.2 �OqD 7- _0 z") S D — 18+29 O z D AD -READY SUBMITTAL No. I REVISION co C, `V SD 0 rr CONC P = T� _ SDMH T2 1E(S),2j R1M;21 R(NW)-21 5,12'RCP4, SUMP,1 g 5' 121 RCP P � SD D° SpCB T 1 SD IF (NW);22 RIM , 24 68 SD - ON &V*^ k e WASTEWATER UTILITY BY APP'D DATE jstowell08/29/2024 12+00 / (425) 453-5000 1100 112TH AVE NE, SUITE 500 BELLEVUE, WA 98004 WATER UTILITY , �' JValdez 09/05/2024 NO PARK1IVG 0 F� P SDCB T1 OPW )\24.R1 M226.3j, OF SED; RCP 24.p1 DESIGNED: APPROVED: I. VANBLANKENSTEIN G. FRANCO DRAWN: A. ZEA CHECKED: PROJECT N0: P.TISSELL E00566E18 CHECKED: CONTRACT NO: K. CHANG YUEN icxxxxxxxx 4 i� w bi (n W 14 0 0 d- Q Lij Z_ J I— Q RT LqNE MUST TURN R T SpCB T1 (W)z24.2 1M I 6.21, Sum 1 RCP I LIM King County METRO GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV TRANSMISSION LINES. 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION ZONE. UTILITY NOTES 20 ADJUST EXISTING MANHOLE TO GRADE 23 RELOCATE UTILITY POLE (BY PSE) 24 RELOCATE VAULT (BY OTHERS) 25 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) 28 EXISTING UNDERGROUND TELECOM CONDUIT 29 EXISTING UNDERGROUND GAS MAIN (PSE) GADJUST GAS VALVE (BY PSE) 41 RELOCATE GAS MAIN (BY PSE) 42 RELOCATE GAS MARKER (BY PSE) 44 RELOCATE UTILITY RISER (BY OTHERS) 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) GADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) GADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) 50 PROTECT EXISTING FEATURE IN PLACE 56 RELOCATE TRANSFORMER (BY PSE) 57 RELOCATE MANHOLE (BY OTHERS) 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) GADJUST JUNCTION BOX OR PULL VAULT TO GRADE 60 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. 0' 20' 40' DEVELOPMENT ENGINEERING " = Michael Sip2po 09/11/2024 SCALE: 120' F-S-421410 METRO TRANSIT CAPITAL DIVISION RAPIDRIDE I LINE RENTON SEGMENT UTILITY PLAN G RA 10+00 TO G RA 14+00 W-421410 TDATE: JUNE 2024 DRAWING NO: 1 UT.01 SHEET NO: OF 192 473