Loading...
HomeMy WebLinkAboutS-4214011o z r N w x N 12" VERTICAL CROSS, MJxFL (STA. 15+50.24, 6 z o 87.31' LT) LU Of ENFo 9 RCED z 1 IE�/v , 22.6' __25 4 )\22 ,2" 0 6 11 RCp 1-FH (STA. 14+64.05, 49.00' LT) 3 Sup,,, 2 R cp 1-12 X6 TEE, MJxFL (STA. &R o N 14+64.68, 20.71' LT),I 1-6" GATE VALVE, FLxMJ[if 60 LF1 J a 25 LF 6" DUCTILE IRON PIPE CONC. BLKG 0 OHP 0 SEE PROFILE G ON DWG 1UP.02 P-H lE(� l RlM,2S WOOD p 23 5 • 4 �' °ST 61 / Ly �- 12" VERTICAL CROSS, 6 x MJxFL (STA. 14+62.76) W 20.55' LT) z LL.I _ - - _ _ L � CONC X LiJ W 47 47 o z w w J X I 2 CONNECT TO EXIST 8" W WITH: 1-12'W" TEE, MJx FL (STA. 15+50.15, 82.31' LT) 1-8" GATE VALVE, FLxMJ (STA. 15+53.26, 82.28' LT) 1-8" 90' BEND, MJxMJ (STA. 15+56.37, 82.32' LT) 1-8" MJ SLEEVE 1-12" MJ PLUG 2-8" DI SPOOLS CONC. BLKGS SEE PROFILE B ON DWG 1 UP.01 pII/N Po rN °E T� SD o 0 • 4,2 pWR °� Not" 33"-3,» 20 / � p z 0 00 S G RADY WAY 15+22 00 LF 18 O 2-1 -}- (GRA-LINE) 1-12"x12" CROSS, FLxFL (STA. 15+49.06, 21.81' LT) 4-12" GATE VALVE, FLxMJ 1-12" MJ PLUG CONC. BLKG � Q ry U U 1 > co T N LLJ N AP P OX. = _Z -J P = T c0I "' U ENF�Oro to R� m � E- D C N N — �2 ASP[ z °S R 28 50 cE T, CD LU lE Rl E<N (N)\24 M 8 ps9 I /Eis) p)23.g �8 ?0•Di �Of rOp 3.9 RCP x sDCe of sED °RCP IO a /E�s)rl RIA4 23 S' SD o 24.' 6'p02' 2-1S 8 �C L- w Of I 0 z of I z O F- F- X a a_ O �I O X 3 z CD J Q X 3 0 N O N N o F- w 2 o Of O o m > Q J U � Y o F-Q w a> 6 IV ono m col AD -READY SUBMITTAL w w Co u? 04 X CDCV a) _ O a C a- Y=5O o � X 3:w ui I� U) LL Q ~p w Q X No. REVISION C) a_ � 12" DI WATER MAIN UT R E_ T= PROPOSED ROW LLJ I SD Q , 1 U ZD f— Q C) BY I APP'D I DATE I I � — I I I 11 C) . if. - . . 1-FH (STA. 16+42.02, 51.95' LT) 20 3 1-12"x6" TEE, FLx FL (STA. 16+42.05, 22.65' LT) 1-12" GATE VALVE, FLxMJ 50 35 1-6" GATE VALVE, FLxMJ 1- 12" FLxMJ ADAPTOR 30 LF 6" DUCTILE IRON PIPE R2 Po/ CONC. BLKG sDce pq p42SEE PROFILE C ON DWG 1UP.01 lEiSw) T� Rl Nq SUMPa2 12 s �o sDc 45 In 6' RCp lE �) I4 R/M1 2R cp wMN RIM, ASPH F SED\24 6' �,48,•PARKIN SIP OHP D17 U4712 3 17+00 16+ I0 - - GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR s� RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 41 /E<NE 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS /E(s% FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SDMN V GAS END CAP I Top SIGNAL, ELECTRICAL, LIGHTING,AND INTERCONNECT E IPMENT S GQU / P,p SUA/ N28.�/, Dc STgE�SPPEN2E INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. E(E),2 NOT t, sIZE PROPOSED ROW l e T2 /E E)�sTq 5. ALL UTILITY STRUCTURES MANHOLES, CLEANOUTS, JUNCTION so 6" cMp \ lE< ),23 0'' 6 2�Mp' IETw) 232 BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, p\23 0' SD sop 6" cMp 2 °p OF WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A 6� 45 o.s 0 NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. C. OHP OHP OHP lm �o px93 LF OF 1211 28 50 DI WATE MAIN T T c— P - - - P BRUSH P P P P - P T T T EX ROW ROUNDED 0 • 27 50 WATER AND SANITARY SEWER NOTES JB • sDCE Q INSTALL NEW 12" DUCTILE IRON WATER MAIN. DEFLECT WATER MAIN AROUND CURVE TO To(s),24�1RIA4 2S e MAXIMUM OF J MANUFACTURER'S RECOMMENDED MAXIMUM DEFLECTION. SEE PROFILE A ON Op sED 8 Rcp 3 DWG 1 UP.01. SDCE 23.9, 1EM), T, Rip, Q2 CITY OF RENTON TO INSTALL AND CONNECT TO EXISTING WATER MAIN AFTER SUCCESSFUL 24' 8"Rcp 2S'8j' PRESSURE TEST, POLYPIGGING, AND DISINFECTION PER SECTION 5-14.2 OF THE CITY OF Top Op - °F sED e RCP RENTON WATER UTILITY CONSTRUCTION STANDARDS. CONCRETE BLOCKINGS PER CITY OF 23'g' RENTON STD PLAN 330.1. CONTRACTOR TO PROVIDE ALL MATERIALS, EXCAVATION, SHORING, BACKFILL AND FINAL ROADWAY RESTORATION. 29 50 Q3 INSTALL NEW FIRE HYDRANT ASSEMBLY PER CITY OF RENTON STD PLAN 310.1. CONCRETE BLOCKING PER CITY OF RENTON STD PLAN 330.1. Q6 INSTALL POLYPIG STATION PER CITY OF RENTON STD PLAN 300.7. CONCRETE BLOCKING PER CITY OF RENTON STD PLAN 330.1. Qg ABANDON EXISTING WATER MAIN IN PLACE WITH INSTALLATION OF CDF FILL PER CITY OF RENTON STANDARDS. INSTALL MJ CAP ON EACH END. 11 REMOVE EXISTING VALVE BOX PER WATER NOTE 27 ON DWG 1 UT.OA 12 REMOVE EXISTING 12" DI WATER MAIN AS NEEDED. OTHERWISE ABANDON PER NOTE 9. 13 REMOVE AND SALVAGE EXISTING FIRE HYDRANT ASSEMBLY. 7 (425) 453-5000 1100 112TH AVE NE, SUITE 500 COBELLEVUE, WA 98004 WASTEWATER UTILITY �' WATER UTILITY jjstowell 08/29/2024 JValdez 09/05/2024 T&T 28 50T= • ' ' ' ' ' ' 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV • G G ~ TRANSMISSION LINES. 25 G PARK NG 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION P - - _ - - - - - - - 7 ZONE. ---,- - - w UTILITY NOTES c c T (n 20 ADJUST EXISTING MANHOLE TO GRADE T TGRASS OHP W 23 RELOCATE UTILITY POLE (BY PSE) OHP OHS HP � G RELOCATE VAULT (BY OTHERS) 60 P 45 1 25 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) OH20 1 _ 9 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) P - _ _ O OHP +00 HP 0 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) - - 47 OHP� + O 28 EXISTING UNDERGROUND TELECOM CONDUIT OHP � OHPEXISTING UNDERGROUND GAS MAIN (PSE) Cy, 40 ADJUST GAS VALVE (BY PSE) 12 41 RELOCATE GAS MAIN (BY PSE) "j 42 RELOCATE GAS MARKER (BY PSE) z P J 44 RELOCATE UTILITY RISER (BY OTHERS) CONIC - ------ BRUSH = 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING - - U AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN w I_ OF 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) �C. 9 MwE dAT MA /EDGE rl 48 ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) 7-op �EOP- S3_D 8 Rcf-) stop G ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) SED, RCp O 23.0• Q90 PROTECT EXISTING FEATURE IN PLACE GRELOCATE TRANSFORMER (BY PSE) 57 RELOCATE MANHOLE (BY OTHERS) 17 REMOVE WATER VALVE AND ABANDON MANHOLE PER SPECIFICATIONS. 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) 18 DEFLECT WATER MAIN UNDER EXISTING STORM DRAIN WITH 18" VERTICAL G ADJUST JUNCTION BOX OR PULL VAULT TO GRADE SEPARATION AND 22 LINEAR FEET OF 24" STEEL CASING PER CITY OF RENTON STD 60 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL PLAN 300.8. MAXIMUM DEFLECTION OF WATER MAIN TO4MANUFACTURERS WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN RECOMMENDED MAXIMUM DEFLECTION. 20 SEE LANDSCAPE DRAWINGS AND SPECIFICATIONS FOR IRRIGATION RESTORATION 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. REQUIREMENTS. 25 DRAIN AND ABANDON EXISTING SANITARY SEWER FORCE MAIN IN PLACE. 35 SHORE WATER MAIN TRENCH IN ACCORDANCE WITH PSE REQUIREMENTS FOR PROTECTION OF STEEL POWER POLE. DESIGNED: APPROVED: I. VANBLANKENSTEIN G. FRANCO DRAWN: A. ZEA CHECKED: PROJECT NO: P.TISSELL E00566E18 CHECKED: CONTRACT NO: K. CHANG YUEN Cxxxxxxxx 0' 20' 40' DEVELOPMENT ENGINEERING ff%I IL Michael Sippo 09/11 /2024 SCALE: 1" = 20' S-421411 W-421411 METRO TRANSIT CAPITAL DIVISION DATE: LIM RAPIDRIDE I LINE JUNE2024 King County RENTON SEGMENT DRAWING NO: MET UTILITY PLAN 1 UT.02 GRA 14+00 TO GRA 19+00 SHEET NO: OF 193 473