HomeMy WebLinkAboutS-4214018U
0
0
12
z
0
z
w
0
fy
X
z
0
z
w
JI
Q
z
0
x
z
0
z
w
n'
4
X
z
0
z
w
JI
X
z
0
Z
w
I
J
LU
0
N
N
z
0
z
w
ry
�I
X
z
0
z
w
ry
0
X
L�
Z
0
z
w
ry
ry
I
0
X
0
U
H
LU
w
X
Z
0
z
w
ry
I
Z
0
Q
u?
X
0
ry
a
0
X
3
rn 0
O J
� Q
X
Z
0
>. a
J O
N
— O
0 NI
_0 ry
o w
ry
x0 m
CC) J
M §E 7>
coo U �
a.
C) m ai
Q0
LQ
cy)o
"' o w
v M LUI O �
a v X
O N ?�
O a
� o
a) 0
� c d
0 O
0 o X
LLJ (n
�IF---LLU
LU0
0-0
U a X
54+00
r
it
(0)
o
'2v
z �� r
55+00
o� O
o) 0) �
SON
_3
\
A//�\_
r\/ P'1!\14/
0 EX ROW
AD -READY SUBMITTAL 7
(425) 453-5000
1100 112TH AVE NE, SUITE 500
BELLEVUE, WA 98004
WASTEWATER UTILITY 00%fj
JValdez 09/05/2024 WATER UTILITY
No. REVISION BY APP'D DATE jstowell 08/29/2024 191
GENERAL NOTES
1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET.
2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS.
3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR
RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY.
4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS
FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING
SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT
INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES.
5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION
BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK,
WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A
NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS.
S� G'� / 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV
o Q �o TRANSMISSION LINES.
7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND
j VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION
ZONE.
UTILITY NOTES
\o �, 20 ADJUST EXISTING MANHOLE TO GRADE
\r, CO (V
JRD om����� �" � / 23 RELOCATE UTILITY POLE (BY PSE) �
24 RELOCATE VAULT (BY OTHERS)
�� O
\ �J ^`v/^`o� 25 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) O
moo. r
,� /�°'� ,� Q �0 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE)
O
o �Q�``��_�4�� CO 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE)
(�N 28 EXISTING UNDERGROUND TELECOM CONDUIT
co 29 EXISTING UNDERGROUND GAS MAIN (PSE)
CO
CO 40 ADJUST GAS VALVE (BY PSE)
N
/cv
�v 41 RELOCATE GAS MAIN (BY PSE)
T 0 0
T � _ 42 RELOCATE GAS MARKER (BY PSE) Q
- SD O
44 RELOCATE UTILITY RISER (BY OTHERS) Q
cw
_ 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING r
W M AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN N
29 50 �
58+0&- 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) a
SS 48 ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS)
G - G G
SS 49 ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS)
� 5
G G 0
50 PROTECT EXISTING FEATURE IN PLACE
h
_ OHP 56 RELOCATE TRANSFORMER (BY PSE)
Y OHP N
O
_ 57 RELOCATE MANHOLE (BY OTHERS) O
58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) 0
O oe
59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE N
REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL
WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN
61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND
COORDINATE RELOCATION OR ABANDONMENT WITH OWNER.
0' 20' 40'
Fic
VELOPMENT ENGINEERING SCALE: 1" - 20'
hael Sippo 09/11 /2024 tj
S-421418 W-421418
DESIGNED: APPROVED: METRO TRANSIT CAPITAL DIVISION DATE:
I. VANBLANKENSTEIN G. FRANCO JUNE 2024
DRAWN: RAPIDRIDE I LINE
A. ZEA LQ King County
CHECKED: PROJECT NO: R E N TO N SEGMENT DRAWING NO:
P. TISSELL E00566E18 METRO UTILITY PLAN 1 UT.09
CHECKED: CONTRACT NO: TAL-21 54+00 TO TAL-21 59+00 SHEET NO: OF
K. CHANG YUEN CXXXXXXXX
200 473