Loading...
HomeMy WebLinkAboutS-4214024I a Y_ O Z O N U N z O z w O fy N o LU N JI d Q z 0 X z O z w n' 4 X z O z w I J X a� z O z w I J w X O N N z O z w ry �I X z O z w ry 0 X z O z w ry ry I 0 X O U w w X z O z w ry I z O Q X O ry a O X 3 Z C.7 J =D Q X o >. a J O N — O � NI ry o W 0 XO m CC) J Cl) o U a. C) m ai Q0 L Q CY) o LO N W v M W I p � aa, x O N ?� O a � o a) O � c d �o 0 0 X 3: w v> 3I�__wC7 0-0 w Q U a X IWN 0.65' IN MON CASE 8.5' CHAINLINK EX ROW � � o 0 0 FND 1 3/4" BRASS DISC W/PUNCH DOWN 0.JINMON CASE— — - — — VE AHEAD CONC W� W�� W SD W S 23+00 SE 180TH ST 24+00 SD 25+00 (105TH-LINE) � D D CONC Ib P P CULVERT IE 8" ADS (S)=385.0' SDCB T1 RIM=383.30' IE(N)=380.9' 12"CMP SUMP=379.6' GATE IN PEDESTRIAN GUARDRAIL PROVIDED TO PROVIDE 3' CLEAR ACCESS AROUND HYDRANT. SEE DWG 151.25 & DETAIL D ON 156.02 0 SDCB T1 RIM=383.40' IE(S)=379.7' 12"CMP IE(E)=379.6' 12"CONC IE(W)=379.6' 12"CONC SUMP=377.9' /�-- CURB DESTROYED ASPH FULVERT IE 48" CMP (W =381.2' GRASS 3' METAL HANDR IL ST P ik, VANTAGE POINT APTS 26+00 34 CULVERT IE 48" CMP O- SD f- c We ASPH 3' METAL HANDRAIL w FT 7 7`�Vr 0 — P 7_7 L ----------- 6' 129 � CHAINLINK 128 NI7 CROSSWALKEX RO507 DS 50 A NDS NAIL/WASHER II I APS GAS 2 R31 I50"-52" I J WATER NOTES GRASS W w +00 SDCB T1 RIM=388.14' IE(W)-383.3 12"CONC IE(S)=383.2 12"CONC 5UMP=382.5' — SD 50 ) 8' CHAINLINK ASPH CULVERT IE 48" CMP (E)=38 — SD � D SSMH T2 RIM=389.60' — IE7)=375.272"PVC TEL IE(S)=375.1' 12"PVC P SDCB T1 RIM=388.16' j SUMIE(N=38 ,3.5 12"CMP SUMP=383.5' NO PARKING — NAIL/Hue 28 50 APS COM 4 R30 55"-59" Q8 ADJUST EXISTING WATER VALVE BOX TO FINISHED GRADE PER COR STD. PLAN 330.1. / 13 REMOVE AND SALVAGE EXISTING FIRE HYDRANT. / / 34 REPLACE EXISTING FIRE HYDRANT WITH NEW FIRE HYDRANT AND CONNECT TO / EXISTING LATERAL. CONCRETE PAD & BEARING BLOCK PER SOOS CREEK WATER & / SEWER DISTRICT STD PLAN W-5. CONCRETE BLOCKING PER SOOS CRE K WATER & / SEWER DISTRICT STD PLAN W-1A & W-1 B. 0' 20' 40' GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV TRANSMISSION LINES. 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION ZONE. UTILITY NOTES 20 ADJUST EXISTING MANHOLE TO GRADE 823 RELOCATE UTILITY POLE (BY PSE) 24 RELOCATE VAULT (BY OTHERS) 825 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) 8 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) 28 EXISTING UNDERGROUND TELECOM CONDUIT 8 29 EXISTING UNDERGROUND GAS MAIN (PSE) 40 ADJUST GAS VALVE (BY PSE) 8 41 RELOCATE GAS MAIN (BY PSE) 42 RELOCATE GAS MARKER (BY PSE) 44 RELOCATE UTILITY RISER (BY OTHERS) 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN 8 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) 48 ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) 8 49 ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) 50 PROTECT EXISTING FEATURE IN PLACE 8 56 RELOCATE TRANSFORMER (BY PSE) 57 RELOCATE MANHOLE (BY OTHERS) 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) 59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE 60 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. DEVELOPMENT ENGINEERING SCALE: 1" = 20' Michael Sippo 09/11 /2024 5-421424 W-421424 AD -READY SUBMITTAL ' DESIGNED:APPROVED. METRO TRANSIT CAPITAL DIVISION DATE: JUNE 2024 Mv�/T ISSFI � I. VANBLANKENSTEIN G. FRANCO (425) 453-5000 Q of S/y, DRAWN: RAP I D RI D E I LINE 1100 112TH AVE NE, SUITE 500cob `" ti L14 King County BELLEVUE, WA 98004 , o CO z A. ZEA 06/1 2 CHECKED: PROJECT NO: R E N TO N SEGMENT DRAWING NO: 31 WASTEWATER UTILITY �F�isTE�`�� � P. TISSELL E00566E18 METRO UTILITY PLAN 1 UT.15 SS/ONAU CHEHANG YUEN CXXXXXXXX CKED: CONTRACT NO: 1 05TH 23+00 TO 105TH 28+00 SHEET NO: OF No. REVISION BY APP'D DATE jstowe1108/29/2024 206 473 0K. C X