HomeMy WebLinkAboutW-42140080 r z N w � o � N X 0 0 L z w J Q Z 0 U) N X Z 0 z N w aJ X z 0 z w J w X z O Z w ryl LF X 0 Z w 0 w J X a z O z w 0 X 0 N N C2 ry W m N N 00 O Z w ry X a Z O z w r' 0 X z O Z w ry z O X a O O X z c� J Q X 0 N 0 N Qo ry I w ry O cu > Q J � U � Y o �Q �w� rn N O> � Co col 70�� m w No C�) 04 X CD iZ� CD CV O a � � Y 0 o � X �'� LU w0 U a_ X 2Ei GENERAL UTILITY NOTES 1. NOT ALL UNDERGROUND UTILITIES ARE NECESSARILY SHOWN ON THE DRAWINGS. CALL 811 "CALL BEFORE YOU DIG" FOR UNDERGROUND UTILITY FIELD LOCATION A MINIMUM OF 48 HOURS PRIOR TO BEGINNING WORK AT EACH SITE. 2. FIBER OPTIC CABLES ARE BURIED WITHIN MOST OF THE SITES OF WORK. EXERCISE EXTREME CARE TO AVOID DAMAGE TO THESE CABLES. REPAIR OR REPLACE THEM, AS DIRECTED BY THE PROJECT REPRESENTATIVE AND TO THE SATISFACTION OF THEIR OWNER(S), IF DAMAGED AS A RESULT OF THE WORK UNDER THIS CONTRACT. 3. ALL TRENCH EXCAVATION OPERATIONS SHALL MEET OR EXCEED ALL APPLICABLE SHORING LAWS FOR TRENCHES. ALL TRENCH SAFETY SYSTEMS SHALL MEET WISHA REQUIREMENTS. TRENCHING THAT MAY AFFECT TREE ROOTS SHALL BE DONE UNDER THE SUPERVISION OF AN ARBORIST APPROVED BY THE AGENCY HAVING JURISDICTION OVER THE SITE WORK. 4. ADJUST TO NEW GRADE ALL MANHOLES, CATCH BASINS, BOXES AND HAND HOLES. ALL UTILITY STRUCTURES (MAINTENANCE HOLES/MANHOLES, CLEANOUTS, JUNCTION BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 5. ALL IMPROVEMENTS SHALL MEET LOCAL, STATE DOT AND A.P.W.A. STANDARD SPECIFICATIONS. 6. THE DESIGN SHOWN IS BASED UPON THE ENGINEER'S UNDERSTANDING OF THE EXISTING CONDITIONS. THIS PLAN DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE EXISTING CONDITIONS SHOWN ON THIS PLAN SHEET ARE BASED UPON SURVEY PREPARED BY 1 ALLIANCE. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING FIELD CONDITIONS PRIOR TO BIDDING THE PROPOSED SITEWORK IMPROVEMENTS. IF CONFLICTS ARE DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE PROJECT REPRESENTATIVE PRIOR TO INSTALLATION OF ANY PORTION OF THE SITEWORK WHICH WOULD BE AFFECTED. IF CONTRACTOR DOES NOT ACCEPT EXISTING SURVEY, INCLUDING TOPOGRAPHY, AS SHOWN ON THE PLANS WITHOUT EXCEPTION THEY SHALL HA1/E MADE AT THEIR OWN EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR AND SUBMIT IT TO THE OWNER FOR REVIEW. 7. CAUTION - NOTICE TO CONTRACTOR THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES AND EXISTING IMPROVEMENTS WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS ON THE PLANS. 8. CONTRACTOR SHALL NOTIFY THE UTILITY AUTHORITIES' INSPECTORS 72 HOURS BEFORE CONNECTING TO ANY EXISTING LINE. 9. MINIMUM WATER AND SANITARY SEWER TRENCH WIDTH SHALL BE 2 FEET. 10. POTABLE PIPES (INCLUDING PIPES CONVEYING WATER FOR DOMESTIC PURPOSES) AND NON -POTABLE PIPES (INCLUDING BUT NOT LIMITED TO PIPES CONVEYING SEWAGE AND STORM DRAINAGE) SHALL HAVE A MINIMUM 10-FOOT (10') HORIZONTAL SEPARATION BETWEEN THE OUTSIDE WALLS/LIMITS OF PARALLEL FACILITIES WHERE THE CROWN OF THE NON -POTABLE PIPE IS LESS THAN 18 INCHES LOWER THAN THE INVERT OF THE POTABLE PIPE. AT CROSSINGS, THE INVERT OF THE POTABLE PIPE IS REQUIRED TO BE A MINIMUM OF 18 INCHES ABOVE THE PIPE CROWN OF THE NON -POTABLE PIPE. ALL OTHER UTILITIES SHALL HAVE A MINIMUM FIVE-FOOT (5) HORIZONTAL SEPARATION (PARALLEL), OR WHEN CROSSING 12" VERTICAL CLEARANCE (OUTSIDE EDGE OF PIPE TO OUTSIDE EDGE OF PIPE OR CONDUIT). 11. IN THE EVENT OF A VERTICAL CONFLICT BETWEEN WATER LINES, SANITARY LINES, STORM LINES AND GAS LINES (EXISTING AND PROPOSED), THE SANITARY LINE SHALL BE DUCTILE IRON PIPE WITH MECHANICAL JOINTS AT LEAST 10 FEET ON BOTH SIDES OF CROSSING, THE WATER LINE SHALL HAVE MECHANICAL JOINTS WITH APPROPRIATE THRUST BLOCKING AS REQUIRED TO PROVIDE A MINIMUM OF 18" CLEARANCE, AND SHALL MEET THE REQUIREMENTS OF ANSI A21.10, ANSI 21.11 AND ANSI 21.51 (AWWA C--151) (CLASS 52), WATER LINES SHALL BE INSTALLED ABOVE SANITARY LINES. 12. LINES UNDERGROUND SHALL BE INSTALLED, INSPECTED AND APPROVED BEFORE BACKFILLING. 13. CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH THE SPECIFICATIONS OF THE LOCAL AUTHORITIES WITH REGARD TO MATERIALS AND INSTALLATION OF THE WATER AND SEWER LINES. 14. CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES FOR INSTALLATION REQUIREMENTS AND SPECIFICATIONS. 15. GAS, ELECTRICAL AND COMMUNICATIONS UTILITIES SHOWN FOR COORDINATION ONLY. RELOCATION/INSTALLATION TO BE ACCOMPLISHED BY UTILITY PROVIDER. 16. SEE SIGNAL PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 17. SEE LIGHTING PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING LIGHTING EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND POLES. CITY OF RENTON - WATER NOTES 1. SEE NOTE 1. UNDER SANITARY SEWER GENERAL NOTES. 2. SEE NOTE 2. UNDER SANITARY SEWER GENERAL NOTES. 3. ALL WATER MAIN PIPE IS TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA Cl 10 AND Cl 11 OR LATEST REVISION, THICKNESS CLASS 52. CEMENT MORTAR LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINTS TO BE PUSH -ON OR MECHANICAL JOINT. BEDDING TO BE CLASS C. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE POLYETHYLENE WRAPPED PER ANSI/AWWA C105/A21.5-93 STANDARDS. 4. CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-87. CEMENT LINING SHALL BE IN ACCORDANCE WITH ANSI/AWWA C104/ 421/4-90. IF FITTINGS ARE 3 TO 12-INCHES IN DIAMETER AND HAVE MECHANICAL JOINTS, THE FITTINGS SHALL BE IN ACCORDANCE WITH EITHER ANSI/AWWA C110-A21.10-87 OR ANSI/AWWA C153/A21.53-94. 3 TO 12-INCH DIAMETER FITTINGS, WHICH HAVE MECHANICAL JOINTS AND/OR FLANGED JOINTS, SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10.87 OR A COMBINATION OF ANSI/AWWA C110/A21.10.87 AND ANSI/ AWWA C153/A21.53-94 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S) MAY BE WITH ANSI/AWWAC153/ A21.53-94 AND THAT PORTION OF THE FITTING WITH FLANGED JOINT(S) SHALL BE IN ACCORDANCE WITH AWWA C110/A21.10-87. ACCEPTANCE TESTING IN ACCORDANCE WITH SECTION 53.53 OF ANSI/AWWA SECTION 10-4.3 OF ANSI/AWWA C110/ A21.10-87 SHALL BE OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. 5. GATE VALVES SHALL BE IRON BODY, BRONZED -MOUNTED, DOUBLE DISC WITH BRONZE WEDGING DEVICE AND 0-RING STUFFING BOX (AWWA C500) OR OF RESILIENT SEATED TYPE (AWWA C509). VALVES SHALL BE DESIGNED FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES SHALL BE CLOW LIST 14, MUELLER COMPANY NO. A2380 OR M & H. 6. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) OR COMPRESSION TYPE OPENING AGAINST PRESSURE CONFORMING TO AWWA C-502-85 WITH A 6-INCH MECHANICAL JOINT INLET AND A MAIN VALVE OPENING (M.V.O.) OF 5-1/4-INCH, TWO 2-1/2-INCH HOSE NOZZLES WITH NATIONAL STANDARD THREADS 7-1/2 THREADS PER INCH AND ONE 4-INCH PUMPER NOZZLE WITH THE NEW SEATTLE PATTERN 6 THREADS PER INCH, 60 DEGREES V. THREADS: OUTSIDE DIAMETER OF MALE THREAD 4.875 AND ROOT DIAMETER 4.6263. HYDRANTS SHALL HAVE A 1-1/4-INCH PENTAGON OPERATING NUT OPENED BY TURNING N COUNTER CLOCKWISE (LEFT). To r 7. THE TWO 2-1/2 INCH HOSE NOZZLES SHALL BE FITTED WITH CAST IRON THREADED CAPS WITH OPERATING NUT OF THE SAME DESIGN AND PROPORTIONS AS THE HYDRANT STEM NUT. CAPS SHALL BE FITTED O WITH SUITABLE NEOPRENE GASKETS FOR POSITIVE WATER TIGHTNESS UNDER TEST PRESSURES. O r 8. THE 4-INCH PUMPER NOZZLE SHALL BE FITTED WITH A STORZ ADAPTER, 4-INCH SEATTLE THREAD X 5-INCH STORZ. STORZ ADAPTER SHALL BE FORGED AND/OR EXTRUDED 6061-T6 ALUMINUM ALLOY, HARDCOAT N ANODIZED. THREADED END PORTION SHALL HAVE NO LUGS AND TWO SET SCREWS 180 DEGREES APART. STORZ FACE TO BE METAL, NO GASKET TO WEATHER. STORZ CAP TO HAVE SYNTHETIC MOLDED RUBBER GASKET, AND SHALL BE ATTACHED TO HYDRANT ADAPTER WITH 1/8 INCH, COATED, STAINLESS STEEL, AIRCRAFT CABLE. 9. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE PAINT NUMBER 43- 655 SAFETY YELLOW OR APPROVED EQUAL. 10. PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. 11. FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAIL FOR FIRE HYDRANTS, LATEST REVISION. 12. ALL WATER MAINS 10-INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATER MAINS 12-INCHES AND LARGER SHALL BE AT A MINIMUM OF 48-INCHES BELOW FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATER MAINS ARE TO BE LOWERED TO CLEAR. 13. ALL WATER MAINS 6 INCHES AND LARGER IN DIAMETER SHALL BE CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE "POLY PIGS" SHALL BE GIRARD INDUSTRIES AQUA SWAB -AS OR APPROVED EQUAL, 2 LB/CU. FT. DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF "PIG" ONLY. "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION. 14. ALL WATER MAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY OF RENTON. THE QUANTITY OF WATER LOST FROM THE MAIN SHALL NOT EXCEED THE NUMBER OF GALLONS PER HOUR AS LISTED IN CITY OF RENTON STANDARD PLANS & SPECIFICATIONS 7-11.3(11). THE LOSS IN PRESSURE SHALL NOT EXCEED 5 PSI DURING THE 2 HOUR TEST PERIOD. 15. ALL WATER MAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE/WATER SOLUTION. DRY CALCIUM HYPOCHLORITE SHALL NOT BE PLACED IN THE PIPE AS LAID. CHLORINE SHALL BE METERED/ INJECTED IN ACCORDANCE WITH SECTION 7-11.3(12)E OR 7-11.3(12)F OF THE STANDARD SPECIFICATIONS REFERENCED ABOVE. 16. A PRE -CONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF FIVE (5) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. 18. SEE INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING INTERCONNECT CONDUITS AND STRUCTURES. CITY OF RENTON - SANITARY SEWER NOTES 17. TWENTY-FOUR (24) HOURS NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. 1. ALL WORK AND WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION 18. INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT HAVE BEEN MADE TO THE CITY OF RENTON. WHERE WATER METER ARE INSTALLED, CONNECT TO WATER MAIN AND CUSTOMER SERVICE LINE AS REQUIRED BY THE UTILITY PROVIDER. ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT OF WAY. 3. A PRE -CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON.) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 4. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS, AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHER ON THE CONSTRUCTION SITE. 5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO CONSTRUCTION. 6. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 7. THE CONTRACTOR SHALL PROVIDE TO THE UTILITY PROVIDER ANY GUARANTEE OR WARRANTY NORMALLY FURNISHED WITH THE PURCHASE OF ANY MATERIALS USED IN CONNECTION WITH THE PROJECT. 8. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCH ES,THROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 9. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABLIIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 10. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKET ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE WASTEWATER UTILITY. AD -READY SUBMITTAL 7 (425) 453-5000 .4acobS 1100 112TH AVE NE, SUITE 500 BELLEVUE, WA 98004 [jjstowiell ASTEWATER UTILITY o F ER UTILITY No. REVISION BY APP'D DATE 08/29/2024 '� ez 09/05/2024 19. ALL CONNECTION TO EXISTING MAINS IS TO BE ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS, WHICH MAYBE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE PUBLIC WORKS DEPARTMENT. ALL NECESSARY EXCAVATION AND MATERIALS ARE TO BE SUPPLIED BY THE CONTRACTOR AND BE ON -SITE PRIOR TO CITY NOTIFICATIONS. 20. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY FOUR (24) HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS -BUILT DRAWINGS. 21. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF ASSEMBLIES FOR TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL TIE-IN. 22. ALL JOINT RESTRAINT SYSTEMS ( SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS OHIO, OR EQUAL, APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT. 23. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES. OIL MAT STREETS MAYBE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 24. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, TO CITY OF RENTON POLICY, WITHIN 10 DAYS. CALL FOR SUBGRADE INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH. 25. CLASS 52 DUCTILE IRON MAYBE DIRECT TAPPED FOR 3/4 INCH AND 1-INCH SIZE SERVICES. SADDLES SHALL BE USED ON ALL TAPS 1-1/4" TO 2" DIAMETER IN ANY PUBLIC MAIN. LDEVELOPMENT ENGINEERING 26. ALL MECHANICAL JOINT FITTINGS AND VALVES SHALL HAVE RESTRAINED RETAINER GLANDS EQUAL TO MEGALUG SERIES 1100 AND WITH CONCRETE BLOCKINGS. hael Sippo 09/11 /2024 ul 27. VALVES SHALL BE ABANDONED BY REMOVING VALVE BOX LID AND BOX TO A MINIMUM DEPTH OF 2 FEET AND NO DEEPER THAN 12" ABOVE THE CROWN OF THE ABANDONED WATER PIPE.WHERE VALVE BOX HAS BEEN REMOVED, THE VOID SPACE SHALL BE BACKFILLED WITH NATIVE MATERIAL AND PATCHED OR PAVED TO MATCH ADJACENT CONDITIONS AS DIRECTED BY THE ENGINEER. 28. WHERE WATER METERS ARE REMOVED, ABANDON CONNECTING SERVICE LINES AS REQUIRED BY UTILITY PROVIDER. DESIGNED: APPROVED: I. VANBLANKENSTEIN G. FRANCO DRAWN: A. ZEA CHECKED: PROJECT NO: P.TISSELL E00566E18 CHECKED: CONTRACT NO: K. CHANG YUEN CXXXXXXXX King County METRO S-421408 W-421408 METRO TRANSIT CAPITAL DIVISION DATE: RAPIDRIDE I LINE JUNE2024 RENTON SEGMENT DRAWING NO: UTILITY 1 UT.OA GENERAL NOTES SHEET NO: OF 190 473