Loading...
HomeMy WebLinkAboutzS-4214set0 J � z � O J O Q o X �o U r- J O 0- CNU 00 00 m O 70 co L� ono N -I oLLI �I N 0 C� O C N CD ON m a > 0 Y U 0 0 Y � L LU w Q U 0- X 2E TYPICAL SECTION AND DETAIL REFERENCING SYSTEM (1) THE SECTION IS CUT ON DRAWING A101: SECTION LETTER ELEVATION LETTER A Agdkkh� /A .01 A3.01 DRAWING ON WHICH SECTION/ELEVATION APPEARS. (2) ON DRAWING A105 THIS SECTION IS IDENTIFIED: SECTION LETTER SECTION B DRAWING ON WHICH SECTION WAS SCALE: A1.0� TAKEN. (3) DETAILS ARE CROSS-REFERENCED IN A SIMILAR MANNER, EXCEPT THAT DETAILS ARE IDENTIFIED BY NUMBERS RATHER THAN BY LETTERS. VICINITY MAP 99 NOT TO SCALE KENMORE BOTHE 5 k 405 � K�ND MEDINA • TTLE v E • 290a SNOHOMISH CO. KING CO. DUVALL 12 ) REDMOND SAMM. A 202 1 DRAWING NUMBERING SYSTEM KEY: DISCIPLINE U UIVIL DR DRAINAGE E ELECTRICAL EC EROSION CONTROL G GENERAL I INTERCONNECT L LIGHTING R RETAINING WALL S STATION TC TRAFFIC CONTROL TS TRAFFIC SIGNAL U LANDSCAPING UT UTILITY AREA LOCATION (FOR PROJECTS WITH 2 C 1 001 MULTIPLE LOCATIONS) DISCIPLINE SEQUENTIAL DESIGNATOR SEQUENTIAL DRAWING NUMBER WITHIN SEPARATOR DISCIPLINE AND DESIGNATED CATEGORY 1 2 19 King County METRO CIVIL CONSTRUCTION PERMIT #'C2 1 00 1 1 28: COR CONDITIONS OF APPROVAL ARE LISTED ON SHEET 2 - 1 GO.01 F I I I I I I I I I I I I y i i N RENTON SEGMENT 00 N r O O N U N M r O 0 0 KENT SEGMENT ' r N 19 IL q t_=( It --"% W FTLTN OWNER CONTACT: v V� IT W im METRO KING COUNTY METRO m 5 PRESTO JANINE ROBINSON, AICP janirobinson@kingcounty.gov -0 509 405 900 ISS•UAH 2O6.477.7563 a G "Pi R1 E 201 S JACKSON ST Q RENTON SEATTLE, WA 98104 518 99 TU IL 169 18 LINE ENGINEER CONTACT: w° AUBURN SEGMENT IVASN o JACOBS ENGINEERING ISLAND o JOHN MCKENZIE, PIE t� DES 1a1 1 KING COUNTY John. McKenzie@jacobs.com o MOINE 7 ® 425.453.3000 _ MAPLE KENT VALLEY 1100 112TH AVE NE o � AD -READY SUBMITTAL DEVELOPMENT ENGINEERING � BELLEVUE, WA 98004 � Michael Sippo 09/11/2024 � SURVEYOR CONTACT: 169 JUNE 149 2024 1 ALLIANCE ooe� 18 MARK GROOT A URP K EXPECTED RELEASE DATE SEPTEMBER 2024 mark.groot@1-alIiance.com 5 DIA D PROJECT 425.598.2200 ALGONA VICINITY 1261 120TH AVE NE LOCATION MAP WASTEWATER UTILITY REGIONAL FIRE AUTHORITY �Eoti TRANSPORTATION OPERATION WATER UTILITY NOT TO SCALE TACOMA PACIFIC SURFACE WATER UTILITY APPROVED `gip F PiE cEc o. JFarah 09/03/2024 jstowell 08/29/2024 cthomas 08/28/2024 y4�FlRE►0 CBarnes 09/09/2024 JValdez 09/05/2024 [T-421-4-011[S--421-4-0110-421-4011 R-421401 DESIGNED: APPROVED: METRO TRANSIT CAPITAL DIVISION DATE: AD -READY SUBMITTAL ' JUNE 2024 �. A. VILLAR G. FRANCO RAP I D RI D E I LINE (425) 453-5000 �� ®Y W DRAWN: 1100 1 12TH AVE NE, SUITE 500aco �``�a sBELLEVUE, WA 98004 0 C. WILCOX King County CHECKED: PROJECT NO: LQ VOLUME 1 DRAWING NO: 5I48�9 A.STOTT E00566E18 MET RENTON SEGMENT 1 G0.00 No. REVISION BY APP'D DATE ssj®NALSHEET N COVER 6/13/24 CHECKED: CONTRACT N0: 0: OF K. CHANG YUEN CXXXXXXXX 1 473 O N O O O N N Q ABBREVIATIONS: ABBREVIATIONS (CONTINUED): GENERAL NOTES: COR CONDITIONS OF APPROVAL: o a� Coo ti J Z � _ W cV w 00 U o CO X 70 co � Uo C) �_ CD cal c� NI rr N 0 ��ry o N O o92 0,5 m W a > 0 Y U 0 0 e LU (n �I LL L7 w a U 0- X 2E AFO AERIAL FIBER OPTIC AP ANGLE POINT BOC BACK OF CURB BOS BACK OF SIDEWALK BOT BOTTOM BOW BOTTOM OF WALL BTWN BETWEEN CB CATCH BASIN CIP CAST IN PLACE CJ CONSTRUCTION JOINT COA CITY OF AUBURN COK CITY OF KENT CONC CONCRETE CONT CONTINOUS COR CITY OF RENTON CL CENTERLINE CID CENTER POINT CSBC CRUSHED SURFACING BASE COURSE CSTC CRUSHED SURFACING TOP COURSE DIA DIAMETER DWG DRAWING E EASTING EJ EXPANSION JOINT ELEV, EL ELEVATION EX EXISTING FF FRONT OF FACE FG FINISH GRADE FL FLOW LINE HMA HOT MIX ASPHALT IB INBOUND IE INVERT ELEVATION KCM KING COUNTY METRO L LENGTH LT LEFT MAX MAXIMUM MH MANHOLE MIN MINIMUM N NORTHING NO. NUMBER NTS NOT TO SCALE NST NOT STEEPER THAN OB OUTBOUND OC ON CENTER OHP OVERHEAD POWER OHT OVERHEAD TELEPHONE/ TELECOM PC POINT OF CURVATURE No. I REVISION PCC POINT OF COMPOUND CURVATURE POB POINT OF BEGINNING POE POINT OF END PRC POINT OF REVERSE CURVE PROP PROPOSED PSE PUGET SOUND ENERGY PT POINT PI POINT OF INTERSECTION PVC POINT OF VERTICAL CURVE PVC POLYVINYL CHLORIDE PVI POINT OF VERTICAL INTERSECTION PVT POINT OF VERTICAL TANGENT RT RIGHT RTIS REAL TIME INFORMATION SYSTEM ROW RIGHT OF WAY SD STORM DRAIN SF SQUARE FOOT/FEET SHLDR SHOULDER SPA SPACING STA STATION SR STATE ROUTE STD STANDARD SYM SYMMETRICAL TC, TOC TOP OF CURB TCE TEMPORARY CONSTRUCTION EASEMENT TESC TEMPORARY EROSION AND SEDIMENT CONTROL TOW TOP OF WALL TSP TRANSIT SIGNAL PRIORITY TYP TYPICAL UD UNDERDRAIN UNO UNLESS NOTED OTHERWISE UTIL UTILITY W/ WITH WSDOT WASHINGTON STATE DEPARTMENT OF TRANSPORTATION BY I APP'D I DATE APPLICABILITY THE REQUIREMENTS IN THESE NOTES, AS WELL AS IN THE CONTRACT SPECIFICATIONS, SUPPLEMENT THE REQUIREMENTS OF THE AGENCY OR AGENCIES HAVING JURISDICTION OVER THE WORK IN THIS CONTRACT. IN THE CASE OF CONFLICT, THE MOST STRINGENT REQUIREMENTS SHALL APPLY. IN CASE THAT ONE OR MORE ELEMENTS OF THE WORK ARE NOT COVERED BY REQUIREMENTS OF AN AGENCY, OR AGENCIES, THE REQUIREMENTS IN THESE NOTES SHALL APPLY. GENERAL NOTES - (KING COUNTY METRO) 1. ALL WORK METHODS AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND THE LATEST EDITION OF THE SPECIFICATIONS AND THE APPLICABLE DEVELOPMENT GUIDELINES AND DESIGN AND CONSTRUCTION STANDARDS FROM THE AGENCY HAVING JURISDICTION OVER THE SITES OF WORK. 2. CONTACT EACH AGENCY'S PUBLIC WORKS DEPARTMENT AND SCHEDULE AND ATTEND A PRECONSTRUCTION MEETING AT LEAST ONE WEEK BEFORE BEGINNING CONSTRUCTION. ATTENDANTS TO INCLUDE EACH AGENCY'S APPOINTED REPRESENTATIVE(S) AND THE PROJECT REPRESENTATIVE. 3. ASSUME FULL RESPONSIBILITY FOR WORKER SAFETY, AND DAMAGE TO STRUCTURES AND IMPROVEMENTS RESULTING FROM CONSTRUCTION OPERATIONS. 4. MAINTAIN THE FOLLOWING THROUGHOUT THE EXECUTION OF THIS PROJECT, AND AT A LOCATION KNOWN AND ACCEPTABLE TO THE PROJECT REPRESENTATIVE AND THE JURISDICTIONAL REPRESENTATIVES ASSIGNED TO THE PROJECT: A. ALL APPLICABLE PERMITS, AND CONDITIONING THEREIN. B. THE APPROVED PLANS. C. A CURRENT COPY OF THE DEVELOPMENT GUIDELINES AND DESIGN AND CONSTRUCTION STANDARDS FROM EACH AGENCY HAVING JURISDICTION OVER THE SITES OF WORK. D. TRAFFIC CONTROL AND STREET MAINTENANCE PLANS APPROVED BY THE AGENCY OR AGENCIES HAVING JURISDICTION OVER THE SITES OF WORK. E. A CURRENT SET OF RECORD (AS CONSTRUCTED) DRAWINGS. F. COPIES OF THE HEALTH, SAFETY AND ACCIDENT PREVENTION PLANS. 5. WORK SHALL CONFORM TO THE APPROVED DRAWINGS AND THE CONTRACT SPECIFICATIONS. CHANGES TO THESE DOCUMENTS REQUIRE PRE -APPROVAL FROM THE PROJECT REPRESENTATIVE AND THE AGENCY HAVING JURISDICTION OVER THE SITES OF WORK. 6. PROVIDE THE PROJECT REPRESENTATIVE WITH A SET OF RECORD DRAWINGS THAT MEET THE CONTRACT REQUIREMENTS PRIOR TO THE PROJECT FINAL APPROVAL. 7. PRIOR TO CONSTRUCTION OF METRO FOOTINGS AND FACILITIES, PLEASE CONTACT METRO INSPECTORS AND CONSTRUCTION AT BUSSTOPINSPECTIONS@KINGCOUNTY.GOV OR BY PHONE AT 206-263-2381. PLEASE NOTE THAT METRO REQUIRES NOTICE OF AT LEAST THREE WEEKS IN ADVANCE TO SCHEDULE AN INSPECTION. ALL METRO FOOTINGS MUST BE INSPECTED AND APPROVED BY METRO INSPECTORS BEFORE ANY CONCRETE IS POURED. WORK SCHEDULE NOTES 1. DAYS AND HOURS OF WORK SHALL CONFORM TO THE CONDITIONS IN THE PERMITS ISSUED BY THE AGENCY HAVING JURISDICTIONS OVER SITES OF WORK. ON (425) 453-5000 1100 112TH AVE NE, SUITE 500 cobBELLEVUE, WA 98004 DESIGNED: APPROVED: A. VILLAR G. FRANCO DRAWN: C. WILCOX CHECKED: PROJECT NO: A.STOTT E00566E18 CHECKED: CONTRACT NO: l K. CHANG YUEN CXXXXXXXX 1. ISSUANCE OF CIVIL CONSTRUCTION PERMIT C2 1 00 1 1 28 IS FOR THE PURPOSES OF PROJECT BID AND CONTRACTOR PROCUREMENT. CONSTRUCTION SHALL NOT OCCUR UNTIL THE CITY PROJECT MANAGER ISSUES A NOTICE TO PROCEED. 2. A PRE -CONSTRUCTION MEETING SHALL BE HELD WITH THE APPLICANT, PROJECT CONTRACTOR, CITY REPRESENTATIVES AND INSPECTION STAFF PRIOR TO NOTICE TO PROCEED. 3. ALL PROJECT CONSTRUCTION AND INSPECTION FEES SHALL BE PAID PRIOR TO SCHEDULING OF PRE -CONSTRUCTION MEETING AND ISSUANCE OF THE NOTICE TO PROCEED. 4. ALL PROJECT ENTITLEMENTS SUCH AS CONSTRUCTION EASEMENTS AND ROW ACQUISITIONS SHALL BE IN PLACE AND COPIES PROVIDED TO THE CITY PRIOR TO ISSUANCE OF THE NOTICE TO PROCEED. 5. PROJECT PUBLIC AGENCY SERVICE AGREEMENT SHALL BE IN PLACE AND EXECUTED PRIOR TO NOTICE TO PROCEED. 6. ALL OUTSIDE AGENCY PERMITS OR APPROVALS SUCH AS PERMITS FROM SOOS CREEK WATER AND SEWER DISTRICT, DEPARTMENT OF ECOLOGY OR WASHINGTON STATE DEPARTMENT OF TRANSPORTATION SHALL BE IN PLACE AND PROVIDED TO THE CITY PRIOR TO NOTICE TO PROCEED. 7. SHEET 1 EC.OA (PAGE 107): ADD ADDITIONAL NOTES FOR PRE -CONSTRUCTION. NOTES TO BE ADDED TO SPECIFICATIONS. 8. SHEETS 1 L 1 .02, 1 L 1 .04A, 1 L 1 .13, ITS 1 .02B, ITS 1 .07B (PAGES 348, 351 , 360, 383, 400): ITERIS APEX VECTOR (4-WAY) VIDEO DETECTION SYSTEM IS REQUIRED FOR ALL VIDEO DETECTION ON THE PROJECT IN LIEU OF GRIDSMART VIDEO DETECTION CAMERAS. UPDATE PROJECT SPECIFICATIONS. 9. SHEET 1 L2.05 (PAGE 370): CONTRACTOR TO REQUEST STREETLIGHT POLE ID TAG NUMBERS FROM COR TRANSPORTATION MAINTENANCE AFTER ALL STREET LIGHTS ARE INSTALLED AND FURNISH/INSTALL STREETLIGHT ID TAGS PER CITY OF RENTON STANDARD PLANS 12 1. 10. SHEET 1 L2.05 (PAGE 370): A COLUMN ON THE POLE & FIXTURE SCHEDULE IS REQUIRED FOR ADDING LAT/LONG BY CONTRACTOR ON AS -BUILT PLANS. 1 1. SHEET 1 TS 1.00 (PAGE 376): ADD ADDITIONAL NOTES. NOTES TO BE ADDED TO SPECIFICATIONS. 12. SHEET 1 TS 1.0 1 B (PAGE 378): VECTOR VANTAGE FOR VIDEO DETECTION. 13. SHEET 1 TS 1.0713 (PAGE 400): PROVIDE ADDITIONAL SCOOT SYSTEM INFORMATION TO CITY TRANSPORTATION DEPARTMENT FOR REVIEW PRIOR TO NOTICE TO PROCEED. 14. SHEET I C8.02 (PAGE 422): INSTALL STOP BAR TO SOUTHERN EDGE OF WBTL. 15. SHEETS I C8.10, 1 C8.1 1, 1 C8.1 5 (PAGES 434, 436, 44): REMOVE STOP BARS AT RRFB CROSSINGS ON CITY STREETS. KEEP STOP BARS AT RRFB CROSSINGS ON WSDOT HIGHWAYS. Lal King County METRO DEVELOPMENT ENGINEERING Michael Sippo 09/11/2024 T-421402 FS-42140-21 0-4-21400 R-421402 METRO TRANSIT CAPITAL DIVISION DATE: RAPIDRIDE I LINE JUNE2024 GENERAL NOTES AND ABBREVIATIONS DRAWING NO: 1 G0.01 SHEET NO: OF 2 473 O N O O O 9 N N Q J N 0 0 c� 0 0 a co N 0 CD x� boo CC) J w 0000Uw o 00 m X 7 _ co C�� Leo o v o cal o �I � w 0 o N 0 0 0 � m � o p F _Ne U p Y �I F_ LL CD 0-0 w Q C) a_ X r SURVEY PROPOSED EXISTING BENCHMARK 41 0 BORE/POT HOLE W CONTROL POINT I 11 GROUND SHOT X O.00 r IRON PIPE • NSURVEY MONUMENT NSTONE/SPIKE WETLAND/OHW FLAG N RIGHT OF WAY PROPOSED EXISTING ~ RIGHT-OF-WAY N CL PROPERTY LINE ------- TEMPORARY CONSTRUCTION EASEMENT N ROADWAY SIGNING AND STRIPING I PROPOSED EXISTING r qq SIGN O CHANNELIZATION - DASHED LINE CHANNELIZATION - DOUBLE YELLOW LINE CHANNELIZATION - EDGE LINE CHANNELIZATION - WIDE SOLID LINE CHANNELIZATION - WIDE DOTTED LANE LINE - - - - - - - - - - - - - - - - - BICYCLE LANE 0� ONLY SYMBOL BUS SYMBOL o STOP SYMBOL ARROW LEFT ARROW RIGHT ARROW THRU 4 RED BUS LANE PAVEMENT MARKINGS :. RAISED BIKE LANE PAVEMENT MARKINGS C ROADWAY LINETYPES PEDESTRIAN GUARDRAIL RETAINING WALL FENCE PROPOSED 0 0 AD -READY SUBMITTAL No. I REVISION BY I APP'D I DATE EXISTING UTILITY PROPOSED EXISTING COMM CABINET 8 COMM MANHOLE ❑ ❑ COMM PULL BOX m ❑ COMM RISER TEL ❑ COMM VAULT COUPLING FIRE DEPT CONNECTION -� FIRE HYDRANT GAS METER ❑O ❑O GAS VALVE H ❑ GAS VAULT GROUNDING ROD GUY POLE GUY ANCHOR HANDHOLE ❑ HH O JUNCTION BOX ® J B ❑ MONITORING WELL SEWER CLEANOUT S S C 0 0 SEWER MANHOLE SS SS POLYPIG STATION ❑ POST INDICATOR VALVE o P IV POWER CABINET ❑ POWER MANHOLE ❑ ❑ POWER METER ❑ POWER POLE POWER PULL BOX m J B ❑ POWER RISER P ❑ POWER VAULT PSE TRANSFORMER ❑0 ❑ THRUST BLOCK UTILITY POLE UTILITY VAULT U VT U VT WATER HOSE BIB ❑ ❑ WATER MANHOLE ❑ ❑ WATER METER ❑ WATER VALVE ❑ so (425) 453-5000 1100 112TH AVE NE, SUITE 500 cob BELLEVUE, WA 98004 DRAINAGE PROPOSED EXISTING STORM CATCH BASIN, TYPE 1 STORM CATCH BASIN, TYPE 2 0 O STORM CLEANOUT 0coo STORM CULVERT STORM WATER FLOW ARROW - S I G NAL PROPOSED EXISTING SIGNAL PEDESTAL WITH PUSHBUTTON I MAST ARM POLE WITH LUMINAIRE MAST ARM POLE 0— TRAFFIC SIGNAL CONTROLLER CABINET ❑ ELECTRICAL SERVICE CABINET EE JUNCTION BOX - TYPES 1, 2 AND 8 e o O ® Isi B TRAFFIC SIGNAL DETECTION ZONE UNDERGROUND CONDUIT - - - LIGHTING PROPOSED EXISTING ROADWAY LUMINAIRE, BRACKET ARM, { POLE, AND FOUNDATION SIGNAL LUMINAIRE AND BRACKET ARM (LENGTH VARIES) EXISTING PSE LUMINAIRE REPLACEMENT PEDESTRIAN LUMINAIRE, POLE, AND FOUNDATION JUNCTION BOX - TYPES 1, 2/4 AND 3/8 B O 0 ® Isi B CONDUIT --- ITS PROPOSED EXISTING JUNCTION BOX - TYPES 1, 2/4 AND 3/8 ■ O 0 d PULL BOX PB 25-TA CABLE VAULT AERIAL FIBER OPTIC AFO Is 60 Fowl UTILITY LINETYPES PROPOSED UNDERGROUND COMM LINE OVERHEAD COMM LINE UNDERGROUND FIBER OPTIC LINE UNDERGROUND POWER LINE OVERHEAD POWER LINE ABANDONED SEWER LINE UNDERGROUND SEWER LINE ABANDONED STORM LINE UNDERGROUND STORM LINE UNDERGROUND UNDERDRAIN LINE UNDERGROUND WATER LINE UNDERGROUND GAS LINE ABANDON LINE REMOVE LINE DESIGNED: APPROVED: A. VILLAR DRAWN: C. WILCOX CHECKED: PROJECT NO: A. STOTT CHECKED: CONTRACT NO: l K. CHANG YUEN T- OHC FO - n EXISTING T OHC FO n vnr �nr ss ss LID - W W G G LIQ King County METRO LANDSCAPE DECIDUOUS TREE (DASHED LINE INDICATES TREE PROTECTION ZONE OF EXISTING TREE) EVERGREEN/CONIFER TREE (DASHED LINE INDICATES TREE PROTECTION ZONE OF EXISTING TREE) MULCH RIVER ROCK MULCH LAWN SEED SHRUB AND GROUNDCOVER MIX A SHRUB AND GROUNDCOVER MIX B SHRUB AND GROUNDCOVER MIX C SHRUB AND GROUNDCOVER MIX D IRRIGATION CONTROL BOX IRRIGATION CONTROL VALVE IRRIGATION METER ROCKERY WALL PROPOSED STATION (SHOWN AT 1"=10') SHELTER (LARGE RAPIDRIDE SHELTER) SHELTER (F50 SHELTER) TECH PYLON TRASH RECEPTACLE BENCH BIKE RACK ELECTRICAL UTILITY POLE UNDERGROUND TRANSFORMER VAULT CONTROLLER CABINET ELECTRICAL SERVICE CABINET JUNCTION BOX - TYPES 1, 2/4 AND 3/8 CONDUIT — POWER PEDESTAL (FRONT DOOR INDICATED BY THE T") PROPOSED FmI F EXISTING ICB❑ N ICV E] OCC�C PROPOSED EXISTING DEVELOPMENT ENGINEERING Michael Sippo 09/11/2024 T-421403 FS--4214073 W-4-21400 R-421403 METRO TRANSIT CAPITAL DIVISION DATE: RAPIDRIDE I LINE JUNE2024 RENTON SEGMENT GENERAL LEGEND DRAWING NO: 1G0.02 SHEET NO: OF 3 473 VOLUME 1 VOLUME 2 VOLUME 3 N O 0 W I r N qT r 14 O H 0 0 c� 0 0 Si, J 0 0 �o U 00 0 J rl- N U 00 a o CO 0 m co � N O CD N O UI O �I X w N n, oC� c::>00m � N � T � �C� Y � U 0 0 Y 3 w ci) LU CD Q J � U a_X 2i SHEET DRAWING NUMBER DESCRIPTION SHEET DRAWING NUMBER DESCRIPTION SHEET DRAWING NUMBER DESCRIPTION 1 1 GO.00 VOLUME 1 RENTON SEGMENT - COVER 1 2GO.00 VOLUME 2 KENT SEGMENT - COVER 1 3GO.00 VOLUME 3 AUBURN SEGMENT - COVER 2 1 GO.01 GENERAL NOTES AND ABBREVIATIONS 2 2GO.01 GENERAL NOTES AND ABBREVIATIONS 2 3GO.01 GENERAL NOTES AND ABBREVIATIONS 3 1GO.02 GENERAL LEGEND 3 2GO.02 GENERAL LEGEND 3 3GO.02 GENERAL LEGEND 4 1 GO.03 RENTON, KENT & AUBURN - INDEX 4-7 2GO.02A - 2GO.02D KENT-INDEX 4 3GO.03 RENTON, KENT, & AUBURN - INDEX 5-7 1 G1.01 -1 G1.03 RENTON SEGMENT - SHEET KEY 8 -10 2G2.01 - 2G2.03 KENT SEGMENT - SHEET KEY 5 3G3.01 AUBURN SEGMENT - SHEET KEY 8 1C0.01 RENTON SEGMENT - CONTROL NOTES & COORDINATES SHEET 11 2CO.01 KENT SEGMENT - CONTROL NOTES & COORDINATES SHEET 6 3CO.01 AUBURN SEGMENT - CONTROL NOTES & COORDINATES SHEET 9 -10 1 C1.0A -1 C1.0B RENTON SEGMENT - ROW & SURVEY CONTROL ALIGNMENT TABLES AND LEGEND 12 -13 2C1.00 - 2C1.00A KENT SEGMENT - ROW & SURVEY CONTROL ALIGNMENT TABLES 7 3C1.00 AUBURN SEGMENT - ROW & SURVEY CONTROL ALIGNMENT TABLES AND LEGEND 11 - 80 1C1.01 - 1C1.69 RENTON SEGMENT - ROW, SURVEY CONTROL & ALIGNMENT PLANS 14 - 108 2C1.01 - 2C1.94 KENT SEGMENT - ROW, SURVEY CONTROL & ALIGNMENT PLANS 8 - 53 3C1.01 - 3C1.46 AUBURN SEGMENT - ROW, SURVEY CONTROL & ALIGNMENT PLANS 81 - 83 1C4.OA-1C4.00 RENTON - TREE INVENTORY & TREE PROTECTION DETAILS 109-112 2C4.OA - 2C4.OD KENT SEGMENT - TREE INVENTORY TABLES & TREE PROTECTION DETAILS 54 3C4.OA AUBURN SEGMENT - TREE INVENTORY TABLES & TREE PROTECTION DETAILS 84 1C4.00 RENTON SEGMENT - SITE PREPARATION GENERAL NOTES AND LEGEND 113 2C4.00 KENT SEGMENT - SITE PREPARATION GENERAL NOTES AND LEGEND 55 3C4.00 AUBURN SEGMENT - SITE PREPARATION GENERAL NOTES AND LEGEND 85 -106 1 C4.01 -1 C4.17 RENTON SEGMENT - SITE PREPARATION PLANS 114 -153 2C4.01 - 2C4.29 KENT SEGMENT - SITE PREPARATION PLANS 56 - 72 3C4.01 - 3C4.11 AUBURN SEGMENT - SITE PREPARATION PLANS 107 1 EC.OA RENTON SEGMENT - TESC GENERAL NOTES AND LEGEND 154 2EC1.00 KENT SEGMENT - TESC GENERAL NOTES AND LEGEND 73 3EC.00 AUBURN SEGMENT - TESC GENERAL NOTES AND LEGEND 108 -124 1 EC1.01 -1 EC1.17 RENTON SEGMENT - TESC PLANS 155 -189 2EC1.01 - 2EC1.29 KENT SEGMENT - TESC PLANS 74 - 85 3EC1.01 - 3EC1.12 AUBURN SEGMENT - TESC PLANS 125 1 C2.00 RENTON SEGMENT - PAVING GENERAL NOTES AND LEGEND 190 2ED.01 KENT SEGMENT - TESC DETAILS 86 3ED.01 AUBURN SEGMENT - TESC DETAILS 126 - 143 1 C2.01A - 1 C2.17 RENTON SEGMENT - PAVING PLANS 191 2C2.00 KENT SEGMENT - PAVING GENERAL NOTES AND LEGEND 87 3C2.00 AUBURN SEGMENT - PAVING GENERAL NOTES AND LEGEND 144 - 149 1C3.01 - 1C3.06 RENTON SEGMENT - ROADWAY TYPICAL SECTIONS 192 - 224 2C2.01 - 2C2.29 KENT SEGMENT - PAVING PLANS 88 - 99 3C2.01 - 3C2.11 AUBURN SEGMENT - PAVING PLANS 150 - 165 1C10.01 - 1C10.15 RENTON SEGMENT - GRADING PLANS 225 - 238 2C3.01 - 2C3.14 KENT SEGMENT - ROADWAY TYPICAL SECTIONS 100 - 104 3C3.01 - 3C3.05 AUBURN SEGMENT - ROADWAY TYPICAL SECTIONS 166 - 183 106.01 - 106.18 RENTON SEGMENT - CURB RAMP PLANS 242 - 273 2C10.01 - 2C10.29 KENT SEGMENT - GRADING PLANS 105 - 113 3C10.01 - 3C10.08 AUBURN SEGMENT - GRADING PLANS 184 - 187 1 C9.01 - 1 C9.04 RENTON SEGMENT - DRIVEWAY PLANS & PROFILES 274 - 296 2C6.01 - 2C6.20 KENT SEGMENT - CURB RAMP PLANS 114 - 117 3C6.01 - 3C6.04 AUBURN SEGMENT - CURB RAMP PLANS 188 - 189 105.01 - 105.02 RENTON SEGMENT - CIVIL DETAILS 297 - 320 2C9.01 - 2C9.18 KENT SEGMENT - DRIVEWAY PLAN & PROFILES 118 - 119 3C9.01 - 3C9.02 AUBURN SEGMENT - DRIVEWAY PLAN & PROFILES 190 - 191 1 UT.OA - 1 UT.OB RENTON SEGMENT - UTILITY GENERAL NOTES AND LEGEND 321 - 324 2C5.01 - 2C5.04 KENT SEGMENT - CIVIL DETAILS 120 - 121 3C5.01 - 3C5.02 AUBURN SEGMENT - FOOTING DETAILS 192 - 208 1 UT.01 - 1 UT.17 RENTON SEGMENT - UTILITY PLANS 326 2UT.00 KENT SEGMENT - UTILITY GENERAL NOTES & LEGEND 122 3UT.00 AUBURN SEGMENT - UTILITY GENERAL NOTES & LEGEND 209 - 210 1 UP.01 - 1 UP.02 RENTON SEGMENT - UTILITY PROFILES 327 - 358 2UT.01 - 2UT.29 KENT SEGMENT - UTILITY PLANS 123 - 134 3UT.01 - 3UT.11 AUBURN SEGMENT - UTILITY PLANS 211 1 UD.01 RENTON SEGMENT - MANHOLE ADJUSTMENT DETAILS 359 - 360 2UP.01A - 2UP.01 B KENT SEGMENT - UTILITY PROFILES 135 3UP.01 AUBURN SEGMENT - UTILITY PROFILES 212 - 213 1 DR.OA - 1 DR.OB RENTON SEGMENT - DRAINAGE GENERAL NOTES & LEGEND 361 - 363 2UD.01 - 2UD.03 KENT SEGMENT - UTILITY DETAILS 136 3DR.00 AUBURN SEGMENT - DRAINAGE GENERAL NOTES & LEGEND 214 - 230 1 DR.01 -1 DR.17 RENTON SEGMENT - DRAINAGE PLANS 364 2DR.00 KENT SEGMENT - DRAINAGE GENERAL NOTES & LEGEND 137 -147 3DR.01 - 3DR.11 AUBURN SEGMENT - DRAINAGE PLANS 231 - 234 1 DRP.01 - 1 DRP.04 RENTON SEGMENT - DRAINAGE PROFILES 365 - 395 2DR.01 - 2DR.29 KENT SEGMENT - DRAINAGE PLANS 148 - 150 3DRD.01 - 3DRD.03 AUBURN SEGMENT - SHELTER DRAINAGE DETAILS 235 - 242 1 DRD.01 -1 DRD.08 RENTON SEGMENT - DRAINAGE DETAILS 396 - 400 2DRP.01 - 2DRP.05 KENT SEGMENT - DRAINAGE PROFILES 151 -152 3RO.00 - 3RO.01 AUBURN SEGMENT - RETAINING WALL GENERAL NOTES & KEY MAP 243 - 246 1 RO.00 - 1 RO.03 RENTON SEGMENT - RETAINING WALL GENERAL NOTES & KEYMAP 401 - 407 2DRD.01 - 2DRD.07 KENT SEGMENT - DRAINAGE DETAILS 153 3R1.01 AUBURN SEGMENT - RETAINING PLAN AND ELEVATION 247 - 252 1 R1.01 -1 R1.06 RENTON SEGMENT - RETAINING WALL PLAN & ELEVATION 408 - 410 2RO.00 - 2RO.02 KENT SEGMENT - RETAINING WALL GENERAL NOTES & KEY MAP 154 3R2.01 AUBURN SEGMENT - RETAINING WALL DETAILS 253 - 256 1 R2.01 - 1 R2.04 RENTON SEGMENT - RETAINING WALL DETAILS 411 - 422 2R1.01 - 2R1.12 KENT SEGMENT - RETAINING WALL PLAN & ELEVATION 155 3S1.00 AUBURN SEGMENT - STATION GENERAL NOTES AND LEGEND 257 1S1.00 RENTON SEGMENT - STATION GENERAL NOTES AND LEGEND 423 - 429 2R2.01 - 2R2.07 KENT SEGMENT - RETAINING WALL DETAILS 156 -172 3S1.01 - 3S1.17 AUBURN SEGMENT - STATION PLANS 258 - 286 1 S1.01 - 1 S1.29 RENTON SEGMENT - STATION PLANS 430 2S1.00 KENT SEGMENT - STATION GENERAL NOTES AND LEGEND 173 3S3.01 AUBURN SEGMENT - TYPICAL STATION LAYOUTS 287 1S3.01 RENTON SEGMENT - TYPICAL STATION LAYOUTS 431 - 465 2S1.01 - 2S1.34 KENT SEGMENT - STATION PLANS 174 3S4.01 AUBURN SEGMENT - TYPICAL STATION ELEVATIONS 288 1 S4.01 RENTON SEGMENT - TYPICAL STATION ELEVATIONS 466 2S3.01 KENT SEGMENT - TYPICAL STATION LAYOUTS 175 3S5.01 AUBURN SEGMENT - TYPICAL STATION SECTIONS 289 1 S5.01 RENTON SEGMENT - TYPICAL STATION SECTIONS 467 2S4.01 KENT SEGMENT - TYPICAL STATION ELEVATIONS 176 -177 3S6.01 - 3S6.02 AUBURN SEGMENT - TYPICAL STATION DETAILS 290 - 291 1 S6.01 - 1 S6.02 RENTON SEGMENT - TYPICAL STATION DETAILS 468 2S5.01 KENT SEGMENT - TYPICAL STATION SECTIONS 178 3E1.00 AUBURN SEGMENT - ELECTRICAL SITE GENERAL NOTES AND LEGEND 292 1 E1.00 RENTON SEGMENT - ELECTRICAL SITE GENERAL NOTES AND LEGEND 469 - 470 2S6.01 - 2S6.02 KENT SEGMENT - TYPICAL STATION DETAILS 179 -196 3E1.01 - 3E1.12 AUBURN SEGMENT - ELECTRICAL SITE PLANS 293 - 307 1 E1.01 - 1 E1.12 RENTON SEGMENT - ELECTRICAL SITE PLANS 471 2E1.00 KENT SEGMENT - ELECTRICAL SITE GENERAL NOTES AND LEGEND 197 - 207 3E2.01 - 3E2.11 AUBURN SEGMENT - ELECTRICAL DETAILS 308 - 318 1 E2.01 -1 E2.11 RENTON SEGMENT - ELECTRICAL DETAILS 472 - 512 2E1.01 - 2E1.33 KENT SEGMENT - ELECTRICAL SITE PLANS 208 311.00 AUBURN SEGMENT - INTERCONNECT GENERAL NOTES AND LEGEND 319 111.00 RENTON SEGMENT - INTERCONNECT GENERAL NOTES AND LEGEND 513 - 523 2E2.01 - 2E2.11 KENT SEGMENT - ELECTRICAL DETAILS 209 - 211 311.04 - 311.13B AUBURN SEGMENT - INTERCONNECT PLANS 320 - 332 111.01 - 111.16 RENTON SEGMENT - INTERCONNECT PLANS 524 211.00 KENT SEGMENT - INTERCONNECT GENERAL NOTES AND LEGEND 212 - 215 312.01 - 312.04 AUBURN SEGMENT - FIBER SCHEMATIC AND DETAILS 333 - 345 112.01 - 112.13 RENTON SEGMENT - FIBER OPTIC SCHEMATICS, SPLICE DIAGRAMS, AND DETAILS 525 - 569 211.01 - 211.37 KENT SEGMENT - INTERCONNECT PLANS 216 3L1.N1 AUBURN SEGMENT - LIGHTING GENERAL NOTES AND LEGEND 346 1 L1.N1 RENTON SEGMENT - LIGHTING GENERAL NOTES, CONSTRUCTION NOTES, AND LEGEND 570 - 590 212.01 - 212.19 KENT SEGMENT - INTERCONNECT DETAILS 217 - 227 3L1.01 - 3L1.11 AUBURN SEGMENT - LIGHTING PLANS 347 - 365 1 L1.01 - 1 L1.17 RENTON SEGMENT - LIGHTING PLANS 591 2L1.N1 KENT SEGMENT - LIGHTING GENERAL NOTES, CONSTRUCTION NOTES AND LEGEND 228 - 231 3L2.01 - 3L2.04 AUBURN SEGMENT - LIGHTING WIRING SCHEMATIC & POLE SCHEDULE 366 - 375 1 L2.01 - 1 L2.10 RENTON SEGMENT - LIGHTING WIRING SCHEMATICS, SCHEDULES, AND DETAILS 592 - 618 2L1.01 - 2L1.29 KENT SEGMENT - LIGHTING PLANS 232 3TS1.00 AUBURN SEGMENT - SIGNAL GENERAL NOTES AND LEGEND 376 1TS1.00 RENTON SEGMENT - SIGNAL GENERAL NOTES AND LEGEND 619 - 631 2L2.01 - 2L2.13 KENT SEGMENT - LIGHTING SCHEDULE & DETAILS 233 - 250 3TS1.01A - 3TS1.06A AUBURN SEGMENT - SIGNAL SHEETS 377 - 410 1TS1.01A - 1TS1.10A RENTON SEGMENT - SIGNAL SHEETS 634 2TS1.00 KENT SEGMENT - SIGNAL GENERAL NOTES AND LEGEND 251 3TS2.01 AUBURN SEGMENT - SIGNAL DETAILS 411 1C8.00 RENTON SEGMENT - SIGNING & STRIPING GENERAL NOTES AND LEGEND 635 - 696 2TS1.01A - 2TS1.16B KENT SEGMENT - SIGNAL SHEETS 252 3C8.00 AUBURN SEGMENT - SIGNING & STRIPING GENERAL NOTES AND LEGEND 412 - 447 1 C8.01A - 1 C8.17 RENTON SEGMENT - SIGNING & STRIPING PLANS 697 2TS2.01 KENT SEGMENT - SIGNAL DETAILS 253 - 271 3C8.01 - 3C8.12 AUBURN SEGMENT - SIGNING & STRIPING PLANS 448 1 CD.01 RENTON SEGMENT - STRIPING DETAILS 698 2C8.00 KENT SEGMENT - SIGNING & STRIPING GENERAL NOTES AND LEGEND 272 3CD.01 AUBURN SEGMENT - STRIPING DETAILS 449 - 451 1SS.01 - 1SS.03 RENTON SEGMENT - SIGN SCHEDULES 699 - 735 2C8.01 - 2C8.29 KENT SEGMENT - SIGNING & STRIPING PLANS 273 3SS.01 AUBURN SEGMENT - SIGN SCHEDULE 452 1 U1.00 RENTON SEGMENT - LANDSCAPE SCHEDULES, GENERAL NOTES AND LEGEND 736 - 738 2SS.01 - 2SS.03 KENT SEGMENT - SIGN SCHEDULE 274 3U1.00 AUBURN SEGMENT - LANDSCAPE SCHEDULE, NOTES AND LEGEND 453 - 469 1 U1.01 - 1 U1.17 RENTON SEGMENT - LANDSCAPE PLANS 740 2U1.00 KENT SEGMENT - LANDSCAPE SCHEDULE & GENERAL NOTES AND LEGEND 275 - 286 3U1.01 - 3U1.11 AUBURN SEGMENT - LANDSCAPE PLANS 470 - 471 1 U2.01 -1 U2.02 RENTON SEGMENT - LANDSCAPE DETAILS 741 - 773 2U1.01 - 2U1.29 KENT SEGMENT - LANDSCAPE PLANS 287 - 288 3U2.01 - 3U2.02 AUBURN SEGMENT - LANDSCAPE DETAILS 472 - 473 1 U3.01 - 1 U3.02 RENTON SEGMENT - LANDSCAPE ENLARGEMENT PLANS 774 - 775 21.12.01 - 2U2.02 KENT SEGMENT - LANDSCAPE DETAILS AD -READY SUBMITTAL No. I REVISION BY I APP'D I DATE ON (425) 453-5000 1100 112TH AVE NE, SUITE 500 cob BELLEVUE, WA 98004 DESIGNED: 1 APPROVED: A. VILLAR DRAWN: C. WILCOX King County CHECKED: PROJECT NO: A. STOTT METRO l CHECKED: CONTRACT NO: K. CHANG YUEN DEVELOPMENT ENGINEERING AWArl` �' Michael Sippo 09/11/2024 T-4214041 IS-421-4-0-41 W-42140-41 FR--421404 METRO TRANSIT CAPITAL DIVISION DATE: RAPIDRIDE I LINE JUNE2024 RENTON, KENT & AUBURN INDEX DRAWING NO: 1G0.03 SHEET NO: OF 4 473 r N 1 O 0 W H qq Irm 11 1 ti N 1 ce H N 1 ti N 1 L N 11 1 To qq 1 O H z O z W JI a z X z 0 z w Of I 4 X 3 Z O H z w ry r 0 X 3 Z O z w ry 0 X 3 O a �I O X o O C7 O x O cu > O U)l 6o� 00 J ~ p- W W 0 U � c >MX M o � O O66 (V O 04 C) �I NW MO N0 Q' O� m CD if m 6 0 3 0 Y U) ��w w Q CD 00-X� V SHEET KEY - RENTON (SITE PREPARATION, PAVING, SIGNING/STRIPING, DRAINAGE, UTILITY, TESC, & LANDSCAPING) NOT TO SCALE DEVELOPMENT ENGINEERING Ar'A �' Michael Sippo 09/11 /2024 IL FT_- 4 2 14 0- 5 FS--42140-51 W-42140 R-421405 DESIGNED: APPROVED: METRO TRANSIT CAPITAL DIVISION DATE: AD -READY SUBMITTAL ' JUNE 2024 (425) 453-5000 ���� wns,��A. � DRAWNLAR G. FRANCO RAP 1 D RI D E 1 LINE 1100 112TH AVE NE, SUITE 500 cobBELLEVUE, WA 98004®� C. WILCOX King County CHECKED: PROJECT N0: La R E N TO N SEGMENT DRAWING N0: 0ImT"as A. STOTT E00566E18 METRO SHEET KEY 1 G 1.01 ��I®SAL 6/13/24 CHECKED: CONTRACT NO: SHEET NO: OF No. REVISION BY APP'D DATE 1 O F 3 5 473 K.CHANG YUEN CXXXXXXXX N O 0 0 a ca J O O N FIZ r— (\1 M M 0 0 LO ti O U I x N M O O C N 16 0 �I U z O H z W JI a z X Z O z W Of UI H X 3 Z O H z W ry ry I 0 X 3 Z O z W ry n u 0 U) x ~ O � U � J_ W LL U = 00 X E 3 ca -,:� N O 00 (V O " of V W N 0 O ry O OO m (\1 0 U LU 0 Y � CO W a X Q ;� M O CD 0 0 a m J O O N FIZ r- (\1 O O O 0 6 LO M ti LO O U I x N M O O C N 16 0 �I U z O H z W JI a z X Z O z W Of UI H X 3 Z O H z W ry ry I 0 X 3 Z O z W ry n u 0 U) x ~ O U � J_ W LL U = 00 X E 3 L N O 00 (V O " of V W N 0 O cQ' u O OO m (\1 0 U LU 0 Y � CO W a X Q ;� 0 r z N w � o � N X 0 0 L z w J Q Z 0 U) N X Z 0 z N w aJ X z 0 z w J w X z O Z w ryl LF X 0 Z w 0 w J X a z O z w 0 X 0 N N C2 ry W m N N 00 O Z w ry X a Z O z w r' 0 X z O Z w ry z O X a O O X z c� J Q X 0 N 0 N Qo ry I w ry O cu > Q J � U � Y o �Q �w� rn N O> � Co col 70�� m w No C�) 04 X CD iZ� CD CV O a � � Y 0 o � X �'� LU w0 U a_ X 2Ei GENERAL UTILITY NOTES 1. NOT ALL UNDERGROUND UTILITIES ARE NECESSARILY SHOWN ON THE DRAWINGS. CALL 811 "CALL BEFORE YOU DIG" FOR UNDERGROUND UTILITY FIELD LOCATION A MINIMUM OF 48 HOURS PRIOR TO BEGINNING WORK AT EACH SITE. 2. FIBER OPTIC CABLES ARE BURIED WITHIN MOST OF THE SITES OF WORK. EXERCISE EXTREME CARE TO AVOID DAMAGE TO THESE CABLES. REPAIR OR REPLACE THEM, AS DIRECTED BY THE PROJECT REPRESENTATIVE AND TO THE SATISFACTION OF THEIR OWNER(S), IF DAMAGED AS A RESULT OF THE WORK UNDER THIS CONTRACT. 3. ALL TRENCH EXCAVATION OPERATIONS SHALL MEET OR EXCEED ALL APPLICABLE SHORING LAWS FOR TRENCHES. ALL TRENCH SAFETY SYSTEMS SHALL MEET WISHA REQUIREMENTS. TRENCHING THAT MAY AFFECT TREE ROOTS SHALL BE DONE UNDER THE SUPERVISION OF AN ARBORIST APPROVED BY THE AGENCY HAVING JURISDICTION OVER THE SITE WORK. 4. ADJUST TO NEW GRADE ALL MANHOLES, CATCH BASINS, BOXES AND HAND HOLES. ALL UTILITY STRUCTURES (MAINTENANCE HOLES/MANHOLES, CLEANOUTS, JUNCTION BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 5. ALL IMPROVEMENTS SHALL MEET LOCAL, STATE DOT AND A.P.W.A. STANDARD SPECIFICATIONS. 6. THE DESIGN SHOWN IS BASED UPON THE ENGINEER'S UNDERSTANDING OF THE EXISTING CONDITIONS. THIS PLAN DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE EXISTING CONDITIONS SHOWN ON THIS PLAN SHEET ARE BASED UPON SURVEY PREPARED BY 1 ALLIANCE. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING FIELD CONDITIONS PRIOR TO BIDDING THE PROPOSED SITEWORK IMPROVEMENTS. IF CONFLICTS ARE DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE PROJECT REPRESENTATIVE PRIOR TO INSTALLATION OF ANY PORTION OF THE SITEWORK WHICH WOULD BE AFFECTED. IF CONTRACTOR DOES NOT ACCEPT EXISTING SURVEY, INCLUDING TOPOGRAPHY, AS SHOWN ON THE PLANS WITHOUT EXCEPTION THEY SHALL HA1/E MADE AT THEIR OWN EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR AND SUBMIT IT TO THE OWNER FOR REVIEW. 7. CAUTION - NOTICE TO CONTRACTOR THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES AND EXISTING IMPROVEMENTS WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS ON THE PLANS. 8. CONTRACTOR SHALL NOTIFY THE UTILITY AUTHORITIES' INSPECTORS 72 HOURS BEFORE CONNECTING TO ANY EXISTING LINE. 9. MINIMUM WATER AND SANITARY SEWER TRENCH WIDTH SHALL BE 2 FEET. 10. POTABLE PIPES (INCLUDING PIPES CONVEYING WATER FOR DOMESTIC PURPOSES) AND NON -POTABLE PIPES (INCLUDING BUT NOT LIMITED TO PIPES CONVEYING SEWAGE AND STORM DRAINAGE) SHALL HAVE A MINIMUM 10-FOOT (10') HORIZONTAL SEPARATION BETWEEN THE OUTSIDE WALLS/LIMITS OF PARALLEL FACILITIES WHERE THE CROWN OF THE NON -POTABLE PIPE IS LESS THAN 18 INCHES LOWER THAN THE INVERT OF THE POTABLE PIPE. AT CROSSINGS, THE INVERT OF THE POTABLE PIPE IS REQUIRED TO BE A MINIMUM OF 18 INCHES ABOVE THE PIPE CROWN OF THE NON -POTABLE PIPE. ALL OTHER UTILITIES SHALL HAVE A MINIMUM FIVE-FOOT (5) HORIZONTAL SEPARATION (PARALLEL), OR WHEN CROSSING 12" VERTICAL CLEARANCE (OUTSIDE EDGE OF PIPE TO OUTSIDE EDGE OF PIPE OR CONDUIT). 11. IN THE EVENT OF A VERTICAL CONFLICT BETWEEN WATER LINES, SANITARY LINES, STORM LINES AND GAS LINES (EXISTING AND PROPOSED), THE SANITARY LINE SHALL BE DUCTILE IRON PIPE WITH MECHANICAL JOINTS AT LEAST 10 FEET ON BOTH SIDES OF CROSSING, THE WATER LINE SHALL HAVE MECHANICAL JOINTS WITH APPROPRIATE THRUST BLOCKING AS REQUIRED TO PROVIDE A MINIMUM OF 18" CLEARANCE, AND SHALL MEET THE REQUIREMENTS OF ANSI A21.10, ANSI 21.11 AND ANSI 21.51 (AWWA C--151) (CLASS 52), WATER LINES SHALL BE INSTALLED ABOVE SANITARY LINES. 12. LINES UNDERGROUND SHALL BE INSTALLED, INSPECTED AND APPROVED BEFORE BACKFILLING. 13. CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH THE SPECIFICATIONS OF THE LOCAL AUTHORITIES WITH REGARD TO MATERIALS AND INSTALLATION OF THE WATER AND SEWER LINES. 14. CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES FOR INSTALLATION REQUIREMENTS AND SPECIFICATIONS. 15. GAS, ELECTRICAL AND COMMUNICATIONS UTILITIES SHOWN FOR COORDINATION ONLY. RELOCATION/INSTALLATION TO BE ACCOMPLISHED BY UTILITY PROVIDER. 16. SEE SIGNAL PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 17. SEE LIGHTING PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING LIGHTING EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND POLES. CITY OF RENTON - WATER NOTES 1. SEE NOTE 1. UNDER SANITARY SEWER GENERAL NOTES. 2. SEE NOTE 2. UNDER SANITARY SEWER GENERAL NOTES. 3. ALL WATER MAIN PIPE IS TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA Cl 10 AND Cl 11 OR LATEST REVISION, THICKNESS CLASS 52. CEMENT MORTAR LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINTS TO BE PUSH -ON OR MECHANICAL JOINT. BEDDING TO BE CLASS C. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE POLYETHYLENE WRAPPED PER ANSI/AWWA C105/A21.5-93 STANDARDS. 4. CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-87. CEMENT LINING SHALL BE IN ACCORDANCE WITH ANSI/AWWA C104/ 421/4-90. IF FITTINGS ARE 3 TO 12-INCHES IN DIAMETER AND HAVE MECHANICAL JOINTS, THE FITTINGS SHALL BE IN ACCORDANCE WITH EITHER ANSI/AWWA C110-A21.10-87 OR ANSI/AWWA C153/A21.53-94. 3 TO 12-INCH DIAMETER FITTINGS, WHICH HAVE MECHANICAL JOINTS AND/OR FLANGED JOINTS, SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10.87 OR A COMBINATION OF ANSI/AWWA C110/A21.10.87 AND ANSI/ AWWA C153/A21.53-94 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S) MAY BE WITH ANSI/AWWAC153/ A21.53-94 AND THAT PORTION OF THE FITTING WITH FLANGED JOINT(S) SHALL BE IN ACCORDANCE WITH AWWA C110/A21.10-87. ACCEPTANCE TESTING IN ACCORDANCE WITH SECTION 53.53 OF ANSI/AWWA SECTION 10-4.3 OF ANSI/AWWA C110/ A21.10-87 SHALL BE OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. 5. GATE VALVES SHALL BE IRON BODY, BRONZED -MOUNTED, DOUBLE DISC WITH BRONZE WEDGING DEVICE AND 0-RING STUFFING BOX (AWWA C500) OR OF RESILIENT SEATED TYPE (AWWA C509). VALVES SHALL BE DESIGNED FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES SHALL BE CLOW LIST 14, MUELLER COMPANY NO. A2380 OR M & H. 6. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) OR COMPRESSION TYPE OPENING AGAINST PRESSURE CONFORMING TO AWWA C-502-85 WITH A 6-INCH MECHANICAL JOINT INLET AND A MAIN VALVE OPENING (M.V.O.) OF 5-1/4-INCH, TWO 2-1/2-INCH HOSE NOZZLES WITH NATIONAL STANDARD THREADS 7-1/2 THREADS PER INCH AND ONE 4-INCH PUMPER NOZZLE WITH THE NEW SEATTLE PATTERN 6 THREADS PER INCH, 60 DEGREES V. THREADS: OUTSIDE DIAMETER OF MALE THREAD 4.875 AND ROOT DIAMETER 4.6263. HYDRANTS SHALL HAVE A 1-1/4-INCH PENTAGON OPERATING NUT OPENED BY TURNING N COUNTER CLOCKWISE (LEFT). To r 7. THE TWO 2-1/2 INCH HOSE NOZZLES SHALL BE FITTED WITH CAST IRON THREADED CAPS WITH OPERATING NUT OF THE SAME DESIGN AND PROPORTIONS AS THE HYDRANT STEM NUT. CAPS SHALL BE FITTED O WITH SUITABLE NEOPRENE GASKETS FOR POSITIVE WATER TIGHTNESS UNDER TEST PRESSURES. O r 8. THE 4-INCH PUMPER NOZZLE SHALL BE FITTED WITH A STORZ ADAPTER, 4-INCH SEATTLE THREAD X 5-INCH STORZ. STORZ ADAPTER SHALL BE FORGED AND/OR EXTRUDED 6061-T6 ALUMINUM ALLOY, HARDCOAT N ANODIZED. THREADED END PORTION SHALL HAVE NO LUGS AND TWO SET SCREWS 180 DEGREES APART. STORZ FACE TO BE METAL, NO GASKET TO WEATHER. STORZ CAP TO HAVE SYNTHETIC MOLDED RUBBER GASKET, AND SHALL BE ATTACHED TO HYDRANT ADAPTER WITH 1/8 INCH, COATED, STAINLESS STEEL, AIRCRAFT CABLE. 9. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE PAINT NUMBER 43- 655 SAFETY YELLOW OR APPROVED EQUAL. 10. PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. 11. FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAIL FOR FIRE HYDRANTS, LATEST REVISION. 12. ALL WATER MAINS 10-INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATER MAINS 12-INCHES AND LARGER SHALL BE AT A MINIMUM OF 48-INCHES BELOW FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATER MAINS ARE TO BE LOWERED TO CLEAR. 13. ALL WATER MAINS 6 INCHES AND LARGER IN DIAMETER SHALL BE CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE "POLY PIGS" SHALL BE GIRARD INDUSTRIES AQUA SWAB -AS OR APPROVED EQUAL, 2 LB/CU. FT. DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF "PIG" ONLY. "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION. 14. ALL WATER MAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY OF RENTON. THE QUANTITY OF WATER LOST FROM THE MAIN SHALL NOT EXCEED THE NUMBER OF GALLONS PER HOUR AS LISTED IN CITY OF RENTON STANDARD PLANS & SPECIFICATIONS 7-11.3(11). THE LOSS IN PRESSURE SHALL NOT EXCEED 5 PSI DURING THE 2 HOUR TEST PERIOD. 15. ALL WATER MAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE/WATER SOLUTION. DRY CALCIUM HYPOCHLORITE SHALL NOT BE PLACED IN THE PIPE AS LAID. CHLORINE SHALL BE METERED/ INJECTED IN ACCORDANCE WITH SECTION 7-11.3(12)E OR 7-11.3(12)F OF THE STANDARD SPECIFICATIONS REFERENCED ABOVE. 16. A PRE -CONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF FIVE (5) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. 18. SEE INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING INTERCONNECT CONDUITS AND STRUCTURES. CITY OF RENTON - SANITARY SEWER NOTES 17. TWENTY-FOUR (24) HOURS NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. 1. ALL WORK AND WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION 18. INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT HAVE BEEN MADE TO THE CITY OF RENTON. WHERE WATER METER ARE INSTALLED, CONNECT TO WATER MAIN AND CUSTOMER SERVICE LINE AS REQUIRED BY THE UTILITY PROVIDER. ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT OF WAY. 3. A PRE -CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON.) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 4. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS, AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHER ON THE CONSTRUCTION SITE. 5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO CONSTRUCTION. 6. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 7. THE CONTRACTOR SHALL PROVIDE TO THE UTILITY PROVIDER ANY GUARANTEE OR WARRANTY NORMALLY FURNISHED WITH THE PURCHASE OF ANY MATERIALS USED IN CONNECTION WITH THE PROJECT. 8. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCH ES,THROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 9. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABLIIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 10. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKET ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE WASTEWATER UTILITY. AD -READY SUBMITTAL 7 (425) 453-5000 .4acobS 1100 112TH AVE NE, SUITE 500 BELLEVUE, WA 98004 [jjstowiell ASTEWATER UTILITY o F ER UTILITY No. REVISION BY APP'D DATE 08/29/2024 '� ez 09/05/2024 19. ALL CONNECTION TO EXISTING MAINS IS TO BE ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS, WHICH MAYBE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE PUBLIC WORKS DEPARTMENT. ALL NECESSARY EXCAVATION AND MATERIALS ARE TO BE SUPPLIED BY THE CONTRACTOR AND BE ON -SITE PRIOR TO CITY NOTIFICATIONS. 20. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY FOUR (24) HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS -BUILT DRAWINGS. 21. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF ASSEMBLIES FOR TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL TIE-IN. 22. ALL JOINT RESTRAINT SYSTEMS ( SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS OHIO, OR EQUAL, APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT. 23. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES. OIL MAT STREETS MAYBE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 24. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, TO CITY OF RENTON POLICY, WITHIN 10 DAYS. CALL FOR SUBGRADE INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH. 25. CLASS 52 DUCTILE IRON MAYBE DIRECT TAPPED FOR 3/4 INCH AND 1-INCH SIZE SERVICES. SADDLES SHALL BE USED ON ALL TAPS 1-1/4" TO 2" DIAMETER IN ANY PUBLIC MAIN. LDEVELOPMENT ENGINEERING 26. ALL MECHANICAL JOINT FITTINGS AND VALVES SHALL HAVE RESTRAINED RETAINER GLANDS EQUAL TO MEGALUG SERIES 1100 AND WITH CONCRETE BLOCKINGS. hael Sippo 09/11 /2024 ul 27. VALVES SHALL BE ABANDONED BY REMOVING VALVE BOX LID AND BOX TO A MINIMUM DEPTH OF 2 FEET AND NO DEEPER THAN 12" ABOVE THE CROWN OF THE ABANDONED WATER PIPE.WHERE VALVE BOX HAS BEEN REMOVED, THE VOID SPACE SHALL BE BACKFILLED WITH NATIVE MATERIAL AND PATCHED OR PAVED TO MATCH ADJACENT CONDITIONS AS DIRECTED BY THE ENGINEER. 28. WHERE WATER METERS ARE REMOVED, ABANDON CONNECTING SERVICE LINES AS REQUIRED BY UTILITY PROVIDER. DESIGNED: APPROVED: I. VANBLANKENSTEIN G. FRANCO DRAWN: A. ZEA CHECKED: PROJECT NO: P.TISSELL E00566E18 CHECKED: CONTRACT NO: K. CHANG YUEN CXXXXXXXX King County METRO S-421408 W-421408 METRO TRANSIT CAPITAL DIVISION DATE: RAPIDRIDE I LINE JUNE2024 RENTON SEGMENT DRAWING NO: UTILITY 1 UT.OA GENERAL NOTES SHEET NO: OF 190 473 a z O z w ry Q ry X a Z O z w ry J Q z U? X a Z O z w n, J X a Z O z w J w X 3 a Z O z w ry CO a Q Z w CD w J X 3 a Z O F- z w rK 3I O ry P-4 a O ry m N N C2 ry CO C O C O 00 N N 00 O) a Z O z w ry �I X 3 a Z O z w ry Q X 3 a Z O z w ry I z O Q CO P. a� a a O ry a_ 3I O ry X 3 a Z U' J Q X 3 a 0 N O m NI o ry --- w � Q ry O ocu > Q J � U � Y o � Q LU rn IV ono m col co E 70 0-4 CD N Lu ca w �o C�) 04 X CO CD iZ� CD N O a a- Y � O o Q X 3: w vi �I F- L w Q U a_ X 2E 0 r z N w o � X N z 0 L z w J Q z 0 U) N X z 0 z N w aJ X z 0 z w Of I Ly X z O z w C/) ryl X 0 z w 0 w J X a z O z w 0 x 0 N N C2 ry m N N O z O z w ry a z O z w r' 0 X z O z w ry z i O X a a O �I O X 3 Z U' J Q X 3 O N O N o ry I --- w 2 0 r. O CU > Q J � U � Y o �Q w a> rn N O> � Co col co E 70 0-4 CD N � w NI O C�) 04 X CD iZ� CD CV O a � � Y 0 o � X 3: w U) �'� w w Q U a_ X 2Ei E)B 2118R1 M 124.98, MP RCP SU 2p.3 0 z 73 — OHP — OHP- IC(NE 21.3)- 1E )-21.2 RC P / P 1I 0F SED12"RCP 9.2 �OqD 7- _0 z") S D — 18+29 O z D AD -READY SUBMITTAL No. I REVISION co C, `V SD 0 rr CONC P = T� _ SDMH T2 1E(S),2j R1M;21 R(NW)-21 5,12'RCP4, SUMP,1 g 5' 121 RCP P � SD D° SpCB T 1 SD IF (NW);22 RIM , 24 68 SD - ON &V*^ k e WASTEWATER UTILITY BY APP'D DATE jstowell08/29/2024 12+00 / (425) 453-5000 1100 112TH AVE NE, SUITE 500 BELLEVUE, WA 98004 WATER UTILITY , �' JValdez 09/05/2024 NO PARK1IVG 0 F� P SDCB T1 OPW )\24.R1 M226.3j, OF SED; RCP 24.p1 DESIGNED: APPROVED: I. VANBLANKENSTEIN G. FRANCO DRAWN: A. ZEA CHECKED: PROJECT N0: P.TISSELL E00566E18 CHECKED: CONTRACT NO: K. CHANG YUEN icxxxxxxxx 4 i� w bi (n W 14 0 0 d- Q Lij Z_ J I— Q RT LqNE MUST TURN R T SpCB T1 (W)z24.2 1M I 6.21, Sum 1 RCP I LIM King County METRO GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV TRANSMISSION LINES. 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION ZONE. UTILITY NOTES 20 ADJUST EXISTING MANHOLE TO GRADE 23 RELOCATE UTILITY POLE (BY PSE) 24 RELOCATE VAULT (BY OTHERS) 25 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) 28 EXISTING UNDERGROUND TELECOM CONDUIT 29 EXISTING UNDERGROUND GAS MAIN (PSE) GADJUST GAS VALVE (BY PSE) 41 RELOCATE GAS MAIN (BY PSE) 42 RELOCATE GAS MARKER (BY PSE) 44 RELOCATE UTILITY RISER (BY OTHERS) 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) GADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) GADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) 50 PROTECT EXISTING FEATURE IN PLACE 56 RELOCATE TRANSFORMER (BY PSE) 57 RELOCATE MANHOLE (BY OTHERS) 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) GADJUST JUNCTION BOX OR PULL VAULT TO GRADE 60 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. 0' 20' 40' DEVELOPMENT ENGINEERING " = Michael Sip2po 09/11/2024 SCALE: 120' F-S-421410 METRO TRANSIT CAPITAL DIVISION RAPIDRIDE I LINE RENTON SEGMENT UTILITY PLAN G RA 10+00 TO G RA 14+00 W-421410 TDATE: JUNE 2024 DRAWING NO: 1 UT.01 SHEET NO: OF 192 473 o z r N w x N 12" VERTICAL CROSS, MJxFL (STA. 15+50.24, 6 z o 87.31' LT) LU Of ENFo 9 RCED z 1 IE�/v , 22.6' __25 4 )\22 ,2" 0 6 11 RCp 1-FH (STA. 14+64.05, 49.00' LT) 3 Sup,,, 2 R cp 1-12 X6 TEE, MJxFL (STA. &R o N 14+64.68, 20.71' LT),I 1-6" GATE VALVE, FLxMJ[if 60 LF1 J a 25 LF 6" DUCTILE IRON PIPE CONC. BLKG 0 OHP 0 SEE PROFILE G ON DWG 1UP.02 P-H lE(� l RlM,2S WOOD p 23 5 • 4 �' °ST 61 / Ly �- 12" VERTICAL CROSS, 6 x MJxFL (STA. 14+62.76) W 20.55' LT) z LL.I _ - - _ _ L � CONC X LiJ W 47 47 o z w w J X I 2 CONNECT TO EXIST 8" W WITH: 1-12'W" TEE, MJx FL (STA. 15+50.15, 82.31' LT) 1-8" GATE VALVE, FLxMJ (STA. 15+53.26, 82.28' LT) 1-8" 90' BEND, MJxMJ (STA. 15+56.37, 82.32' LT) 1-8" MJ SLEEVE 1-12" MJ PLUG 2-8" DI SPOOLS CONC. BLKGS SEE PROFILE B ON DWG 1 UP.01 pII/N Po rN °E T� SD o 0 • 4,2 pWR °� Not" 33"-3,» 20 / � p z 0 00 S G RADY WAY 15+22 00 LF 18 O 2-1 -}- (GRA-LINE) 1-12"x12" CROSS, FLxFL (STA. 15+49.06, 21.81' LT) 4-12" GATE VALVE, FLxMJ 1-12" MJ PLUG CONC. BLKG � Q ry U U 1 > co T N LLJ N AP P OX. = _Z -J P = T c0I "' U ENF�Oro to R� m � E- D C N N — �2 ASP[ z °S R 28 50 cE T, CD LU lE Rl E<N (N)\24 M 8 ps9 I /Eis) p)23.g �8 ?0•Di �Of rOp 3.9 RCP x sDCe of sED °RCP IO a /E�s)rl RIA4 23 S' SD o 24.' 6'p02' 2-1S 8 �C L- w Of I 0 z of I z O F- F- X a a_ O �I O X 3 z CD J Q X 3 0 N O N N o F- w 2 o Of O o m > Q J U � Y o F-Q w a> 6 IV ono m col AD -READY SUBMITTAL w w Co u? 04 X CDCV a) _ O a C a- Y=5O o � X 3:w ui I� U) LL Q ~p w Q X No. REVISION C) a_ � 12" DI WATER MAIN UT R E_ T= PROPOSED ROW LLJ I SD Q , 1 U ZD f— Q C) BY I APP'D I DATE I I � — I I I 11 C) . if. - . . 1-FH (STA. 16+42.02, 51.95' LT) 20 3 1-12"x6" TEE, FLx FL (STA. 16+42.05, 22.65' LT) 1-12" GATE VALVE, FLxMJ 50 35 1-6" GATE VALVE, FLxMJ 1- 12" FLxMJ ADAPTOR 30 LF 6" DUCTILE IRON PIPE R2 Po/ CONC. BLKG sDce pq p42SEE PROFILE C ON DWG 1UP.01 lEiSw) T� Rl Nq SUMPa2 12 s �o sDc 45 In 6' RCp lE �) I4 R/M1 2R cp wMN RIM, ASPH F SED\24 6' �,48,•PARKIN SIP OHP D17 U4712 3 17+00 16+ I0 - - GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR s� RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 41 /E<NE 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS /E(s% FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SDMN V GAS END CAP I Top SIGNAL, ELECTRICAL, LIGHTING,AND INTERCONNECT E IPMENT S GQU / P,p SUA/ N28.�/, Dc STgE�SPPEN2E INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. E(E),2 NOT t, sIZE PROPOSED ROW l e T2 /E E)�sTq 5. ALL UTILITY STRUCTURES MANHOLES, CLEANOUTS, JUNCTION so 6" cMp \ lE< ),23 0'' 6 2�Mp' IETw) 232 BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, p\23 0' SD sop 6" cMp 2 °p OF WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A 6� 45 o.s 0 NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. C. OHP OHP OHP lm �o px93 LF OF 1211 28 50 DI WATE MAIN T T c— P - - - P BRUSH P P P P - P T T T EX ROW ROUNDED 0 • 27 50 WATER AND SANITARY SEWER NOTES JB • sDCE Q INSTALL NEW 12" DUCTILE IRON WATER MAIN. DEFLECT WATER MAIN AROUND CURVE TO To(s),24�1RIA4 2S e MAXIMUM OF J MANUFACTURER'S RECOMMENDED MAXIMUM DEFLECTION. SEE PROFILE A ON Op sED 8 Rcp 3 DWG 1 UP.01. SDCE 23.9, 1EM), T, Rip, Q2 CITY OF RENTON TO INSTALL AND CONNECT TO EXISTING WATER MAIN AFTER SUCCESSFUL 24' 8"Rcp 2S'8j' PRESSURE TEST, POLYPIGGING, AND DISINFECTION PER SECTION 5-14.2 OF THE CITY OF Top Op - °F sED e RCP RENTON WATER UTILITY CONSTRUCTION STANDARDS. CONCRETE BLOCKINGS PER CITY OF 23'g' RENTON STD PLAN 330.1. CONTRACTOR TO PROVIDE ALL MATERIALS, EXCAVATION, SHORING, BACKFILL AND FINAL ROADWAY RESTORATION. 29 50 Q3 INSTALL NEW FIRE HYDRANT ASSEMBLY PER CITY OF RENTON STD PLAN 310.1. CONCRETE BLOCKING PER CITY OF RENTON STD PLAN 330.1. Q6 INSTALL POLYPIG STATION PER CITY OF RENTON STD PLAN 300.7. CONCRETE BLOCKING PER CITY OF RENTON STD PLAN 330.1. Qg ABANDON EXISTING WATER MAIN IN PLACE WITH INSTALLATION OF CDF FILL PER CITY OF RENTON STANDARDS. INSTALL MJ CAP ON EACH END. 11 REMOVE EXISTING VALVE BOX PER WATER NOTE 27 ON DWG 1 UT.OA 12 REMOVE EXISTING 12" DI WATER MAIN AS NEEDED. OTHERWISE ABANDON PER NOTE 9. 13 REMOVE AND SALVAGE EXISTING FIRE HYDRANT ASSEMBLY. 7 (425) 453-5000 1100 112TH AVE NE, SUITE 500 COBELLEVUE, WA 98004 WASTEWATER UTILITY �' WATER UTILITY jjstowell 08/29/2024 JValdez 09/05/2024 T&T 28 50T= • ' ' ' ' ' ' 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV • G G ~ TRANSMISSION LINES. 25 G PARK NG 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION P - - _ - - - - - - - 7 ZONE. ---,- - - w UTILITY NOTES c c T (n 20 ADJUST EXISTING MANHOLE TO GRADE T TGRASS OHP W 23 RELOCATE UTILITY POLE (BY PSE) OHP OHS HP � G RELOCATE VAULT (BY OTHERS) 60 P 45 1 25 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) OH20 1 _ 9 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) P - _ _ O OHP +00 HP 0 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) - - 47 OHP� + O 28 EXISTING UNDERGROUND TELECOM CONDUIT OHP � OHPEXISTING UNDERGROUND GAS MAIN (PSE) Cy, 40 ADJUST GAS VALVE (BY PSE) 12 41 RELOCATE GAS MAIN (BY PSE) "j 42 RELOCATE GAS MARKER (BY PSE) z P J 44 RELOCATE UTILITY RISER (BY OTHERS) CONIC - ------ BRUSH = 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING - - U AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN w I_ OF 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) �C. 9 MwE dAT MA /EDGE rl 48 ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) 7-op �EOP- S3_D 8 Rcf-) stop G ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) SED, RCp O 23.0• Q90 PROTECT EXISTING FEATURE IN PLACE GRELOCATE TRANSFORMER (BY PSE) 57 RELOCATE MANHOLE (BY OTHERS) 17 REMOVE WATER VALVE AND ABANDON MANHOLE PER SPECIFICATIONS. 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) 18 DEFLECT WATER MAIN UNDER EXISTING STORM DRAIN WITH 18" VERTICAL G ADJUST JUNCTION BOX OR PULL VAULT TO GRADE SEPARATION AND 22 LINEAR FEET OF 24" STEEL CASING PER CITY OF RENTON STD 60 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL PLAN 300.8. MAXIMUM DEFLECTION OF WATER MAIN TO4MANUFACTURERS WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN RECOMMENDED MAXIMUM DEFLECTION. 20 SEE LANDSCAPE DRAWINGS AND SPECIFICATIONS FOR IRRIGATION RESTORATION 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. REQUIREMENTS. 25 DRAIN AND ABANDON EXISTING SANITARY SEWER FORCE MAIN IN PLACE. 35 SHORE WATER MAIN TRENCH IN ACCORDANCE WITH PSE REQUIREMENTS FOR PROTECTION OF STEEL POWER POLE. DESIGNED: APPROVED: I. VANBLANKENSTEIN G. FRANCO DRAWN: A. ZEA CHECKED: PROJECT NO: P.TISSELL E00566E18 CHECKED: CONTRACT NO: K. CHANG YUEN Cxxxxxxxx 0' 20' 40' DEVELOPMENT ENGINEERING ff%I IL Michael Sippo 09/11 /2024 SCALE: 1" = 20' S-421411 W-421411 METRO TRANSIT CAPITAL DIVISION DATE: LIM RAPIDRIDE I LINE JUNE2024 King County RENTON SEGMENT DRAWING NO: MET UTILITY PLAN 1 UT.02 GRA 14+00 TO GRA 19+00 SHEET NO: OF 193 473 a o r z N W o � N X Z 0 L z w QI z 0 U) N X z 0 C" z N C w a z 0 ~ Ld z Of I w Li J W x o W z W wco r^ Ofl v/ LF x I O z � O w J X T VJ Z O z w Cif o C7 x W a z _j 1 N = w N U Q P 0 si � IF 00 d, qF z O z w x a z O z w 0 x z O z w z O Q x a O O x z c� J Q x 0 N 0 ch NI o � w O m C J ~ � U � Y o �Q w rn N O> � m cf)l co CD M H w w IoU) Cm X CV O a Y O o X 3: w cii iF__ U) w Q~pwQ C) a_ Df x No. 2Ei 1-FDC A nn n A I r11 rr\ /r STA. 20+01.69, 43.03' LT T STA. 19+99.16, 43.82' LT I\24 p" 8'?-30' SID 7 r2 SUMpB C Cp p 3 R/M\2A23 pp 45 IFS�Nw�\T2 Top F��2 ? 6' 8 R Rip sFo`? 2.c�p ?J' 1- 1 Z" GATE VALVE (STA. 21 +80.06, 53.25' LT) SEE PROFILE K ON DWG 1UP.02 \AIATFR Ar\in .qAr\IITARY CF1I11FR NIOTFC U INSTALL NEW 12" DUCTILE IRON WATER MAIN. DEFLECT WATER MAIN AROUND CURVE TO MAXIMUM OF MANUFACTURER'S RECOMMENDED MAXIMUM DEFLECTION. SEE PROFILE A ON DWG 1 UP.01. Q3 INSTALL NEW FIRE HYDRANT ASSEMBLY PER CITY OF RENTON STD PLAN 310.1. CONCRETE BLOCKING PER CITY OF RENTON STD PLAN 330.1. Q4 INSTALL 1" WATER SERVICE PER CITY OF RENTON STD PLAN 320.1. TAP LOCATION AT WATER MAIN AS INDICATED. METER BOX LOCATION AS SPECIFIED. CONNECT TO EXISTING PRIVATE WATER SERVICE LINE. Q5 INSTALL 1-1/2" WATER SERVICE BEHIND SIDEWALK PER CITY OF RENTON STD PLAN 320.3. TAP LOCATION AT WATER MAIN AS INDICATED. METER BOX LOCATION AS SPECIFIED. CONNECT TO EXISTING PRIVATE WATER SERVICE LINE. Qg ABANDON EXISTING WATER MAIN IN PLACE WITH INSTALLATION OF CDF FILL PER CITY OF RENTON STANDARDS. INSTALL MJ CAP ON EACH END. 11 REMOVE EXISTING VALVE BOX PER GENERAL NOTE 27 ON DWG 1UT.OA 12 REMOVE EXISTING 12" DI WATER MAIN AS NEEDED. OTHERWISE ABANDON PER NOTE 9. 13 REMOVE AND SALVAGE EXISTING FIRE HYDRANT ASSEMBLY. AD -READY SUBMITTAL ON (425) 453-5000 1100 112TH AVE NE, SUITE 500 .,JacobsBELLEVUE, WA 98004 WASTEWATER UTILITY WATER UTILITY REVISION BY APP'D DATE jstowell 08/29/2024 UIJValdez 09/05/2024 (D A l„ r,o -).1 UnpI= cANITARY SEWER FORCE MAIN 17 RIM oFF�swj\282 . 14 UPON COMPLETION OF NEW WATER SERVICE INSTALLATION, REMOVE EXISTING WATER METER BOX AND ABANDON EXISTING WATER SERVICE LINE. 15 RELOCATE EXISTING FIRE DEPARTMENT CONNECTION. A SEPARATE FIRE SPRINKLER PERMIT IS REQUIRED FROM RENTON REGIONAL FIRE AUTHORITY. 16 INSTALL 8-INCH WATER MAIN CONNECTION AND CONCRETE BLOCKING PER CITY OF RENTON STD PLAN 330.1. INSTALL UNDER PROPOSED DI STORM DRAIN WITH 181, VERTICAL SEPARATION. VERIFY EXISTING AND CONNECT TO EXISTING 8" DI WATER SERVICE WITH 8" MJ SLEEVE. SEE PROFILE I ON DWG 1 UP.02. 17 REMOVE WATER VALVE AND ABANDON MANHOLE PER SPECIFICATIONS. 18 DEFLECT WATER MAIN UNDER EXISTING STORM DRAIN WITH 18" VERTICAL SEPARATION AND 22 LINEAR FEET OF 24" STEEL CASING PER CITY OF RENTON STD PLAN 300.8. MAXIMUM DEFLECTION OF WATER MAIN TO z MANUFACTURER'S RECOMMENDED MAXIMUM DEFLECTION. 20 SEE LANDSCAPE DRAWINGS AND SPECIFICATIONS FOR IRRIGATION RESTORATION REQUIREMENTS. 21 INSTALL NEW 1-1/2" HDPE SDR 21 SANITARY SEWER FORCE MAIN. SEE PROFILE K ON DWG 1 UP.02. 22 INSTALL 1-1/2" GATE VALVE WITH HDPE FUSIBLE ENDS AND REDUCER. 23 VERIFY EXISTING AND CONNECT TO EXISTING 1-1/2" PE SDR-PRESSURE RATED TUBE WITH MECHANICAL COMPRESSION COUPLING. 25 DRAIN AND ABANDON EXISTING SANITARY SEWER FORCE MAIN IN PLACE. 26 ADJUST WATER MANHOLE TO FINISHED GRADE. DESIGNED: I. VANBLANKENSTEIN DRAWN: A. ZEA CHECKED: P. TISSELL CHECKED: K. CHANG YUEN APPROVED: G.FRANCO GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV TRANSMISSION LINES. 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION ZONE. UTILITY NOTES � 20 ADJUST EXISTING MANHOLE TO GRADE = 23 RELOCATE UTILITY POLE (BY PSE) 24 RELOCATE VAULT (BY OTHERS) O W W 25 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) O V ' 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) rm N 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) Lq- 0 0 28 EXISTING UNDERGROUND TELECOM CONDUIT + D29 EXISTING UNDERGROUND GAS MAIN (PSE) N 40 ADJUST GAS VALVE (BY PSE) Q D41 RELOCATE GAS MAIN (BY PSE) 42 RELOCATE GAS MARKER (BY PSE) Lj 44 RELOCATE UTILITY RISER (BY OTHERS) Z 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING J AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN =47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) U Q G ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) s n49 ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) �rNw 50 PROTECT EXISTING FEATURE IN PLACE • G RELOCATE TRANSFORMER (BY PSE) • • 57 RELOCATE MANHOLE (BY OTHERS) 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) 59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE 60 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. 0' 20' 40' DEVELOPMENT ENGINEERINGIL SCALE: 1" = 20' Michael Sippo 09/11/2024 %j King County PROJECT NO: E00566E18 METRO CONTRACT NO: CXXXXXXXX S-421412 METRO TRANSIT CAPITAL DIVISION RAPIDRIDE I LINE RENTON SEGMENT UTILITY PLAN G RA 19+00 TO G RA 24+00 W-421412 DATE: JUNE 2024 DRAWING NO: 1 UT.03 SHEET NO: OF 194 473 or roe o o\ e lb`0�v �J�o °h'A 42 o o �a��,�o QQ �e N �� 20 I o�� , �� 24 20 0 �� oe a /ip 0 e CO EX ROW 7 EL o °S 20 24 29 50 J' PROPOSED ROW S Q — — 0 Tm — — X N i 0 �, P- �; zI EX ROW I- DIRT/BRUSH — N 0 a �� ,. - - -Q -- --- 1 - T ns c X W-T z 6 TT T- I T f- T T T T T TXD:�� T— z c, QT � I 0 r 24"X12" TAPPING TEE, FL (STA. Of � �^ \� 0 28 50 60 47 1\0 w 25+00.05, 31.22 LT) (7 I � x 12" TAPPING GATE VALVE, FLxMJ I CONCRETE CONCRETE BLOCK \ 28 48 U) I I I I TALBOT RD S 12+00 o oe, 50 10 00�° 11+00 I I I— z w U 27 50 6 12" VERTICAL CROSS, o 29 50 I (TAL-B-LINE) 26 29 50 I MJxMJ (STA . 24+90.81, I G 30.70' LT) I II II 1-FH (STA. 11 +10, 61' RT) G G 0 7 G —6 LF 6 DUCTILE IRON PIPE w I SEE PROFILE H ON DWG 1 UP.02 w x 24" DI W ffi 17 m o w +T S SD SD _ 2 G SD SD SD SD G G G G 2-1 LU FA Of —� •� ,�� �--- CO `��'il�, ilk , • ��I cli \J1Of 1 I , • ���� F- POP LU I0 I Lei . O F- z w rK r' 0 X z O z w ry z O F- F- X a O ry a_ 3 O X z c� J Q X 0 N O N o ft�I W � 0 O o m >, Q (6 J 0) U � Y o �Q �w� C' N O> � m Cf) co 0 �_4 AD -READY SUBMITTAL U w w �o U) CD N O a � � Y O o � X w U) i U) w Q ~p w Q U a_ No. REVISION X � �• 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV TRANSMISSION LINES. T 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND T T P T Slop T VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION T T ZONE. Q ti� T T W UTILITY NOTES S T ° \ L/) 20 ADJUST EXISTING MANHOLE TO GRADE 0 D RELOCATE UTILITY POLE (BY PSE) 28 50 G RELOCATE VAULT (BY OTHERS) n RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) G oy 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) A G EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) G 0 SD SD G 28 EXISTING UNDERGROUND TELECOM CONDUIT G US � G 29 EXISTING UNDERGROUND GAS MAIN (PSE) G / G ADJUST GAS VALVE (BY PSE) D6O 10 Q 41 RELOCATE GAS MAIN (BY PSE) RELOCATE GAS MARKER (BY PSE) Q .. ? 44 RELOCATE UTILITY RISER (BY OTHERS) FIRE LA ' � J 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING 20 �`'� 50 z PA H� F I AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN O KIN 13 "e \���° �c°°�� Q p EX ROW ' ' i� 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) �o 4� � Q O 42 '� '��(v 48 ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) o� `�'Q �P °� 0 ° � /�' 49 ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) //'o PROPOSED R W Q Q Nv ae �o ' O o z � ,;° IV 50 PROTECT EXISTING FEATURE IN PLACE G 45 Q C �a e�� 56 RELOCATE TRANSFORMER (BY PSE) "�z RELOCATE MANHOLE (BY OTHERS) O WATER AND SANITARY SEWER NOTES 4� GRELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) ,� ����� �� �oo� Q INSTALL NEW 12" DUCTILE IRON WATER MAIN. DEFLECT WATER MAIN AROUND CURVE TO 17 REMOVE WATER VALVE AND ABANDON MANHOLE PER SPECIFICATIONS. MAXIMUM OF z MANUFACTURER'S RECOMMENDED MAXIMUM DEFLECTION. SEE PROFILE A ON 59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE DWG 1UP.01. 20 SEE LANDSCAPE DRAWINGS AND SPECIFICATIONS FOR IRRIGATION RESTORATION REQUIREMENTS. UO REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL QINSTALL NEW FIRE HYDRANT ASSEMBLY PER CITY OF RENTON STD PLAN 310.1. CONCRETE WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN BLOCKING PER CITY OF RENTON STD PLAN 330.1. 21 INSTALL NEW 1-1/2" HDPE SDR 21 SANITARY SEWER FORCE MAIN. SEE PROFILE K ON DWG 1 UP.02. 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND QINSTALL POLYPIG STATION PER CITY OF RENTON STD PLAN 300.5. CONCRETE BLOCKING PER 24 REMOVE EXISTING FORCE MAIN CONNECTION AND CONNECT NEW FORCE MAIN TO COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. CITY OF RENTON STD PLAN 330.1. EXISTING SANITARY SEWER MANHOLE WITH KOR-N-SEAL 1 106 SERIES BOOT CITY OF RENTON TO ABANDON WATER MAIN WITH MJ PLUG ON EXISTING 12"X12" TEE. CONNECTOR PER DETAIL 1 ON DWG 1 UP.02. CONCRETE BLOCKING PER CITY OF RENTON STD PLAN 330.1. CONTRACTOR TO PROVIDE ALL 25 DRAIN AND ABANDON EXISTING SANITARY SEWER FORCE MAIN IN PLACE. MATERIALS, EXCAVATION, SHORING, BACKFILL AND FINAL ROADWAY RESTORATION. Q9 ABANDON EXISTING WATER MAIN IN PLACE WITH INSTALLATION OF CDF FILL PER CITY OF 26 ADJUST WATER MANHOLE TO FINISHED GRADE AND REPLACE EXISTING VENTED RENTON STANDARDS. INSTALL MJ CAP ON EACH END. GRATE WITH SKID RESISTANT SOLID MANHOLE COVER. SEE DETAIL ON DWG 1 UD.01. 10 CONNECT TO CITY OF RENTON WATER MAIN WITH 24"X12" TAPPING TEE AND 12" TAPPING GATE 27 INSTALL NEW FIRE HYDRANT ASSEMBLY AND CONNECT TO EXISTING 6" GATE VALVE PER CITY OF RENTON STD PLAN 300.6. CONCRETE BLOCKING PER CITY OF RENTON STD PLAN 330.1. CITY OF RENTON TO INSTALL FINAL CONNECTION AFTER SUCCESSFUL PRESSURE VALVE PER CITY OF RENTON STD PLAN 310.1. TEST, POLYPIGGING, AND DISINFECTION PER CITY OF RENTON STD PLAN 300.6. CONTRACTOR TO PROVIDE ALL MATERIALS, EXCAVATION, SHORING, BACKFILL AND FINAL ROADWAY RESTORATION. 12 REMOVE EXISTING 12" DI WATER MAIN AS NEEDED. OTHERWISE ABANDON PER NOTE 9. 13 REMOVE AND SALVAGE EXISTING FIRE HYDRANT ASSEMBLY. (425) 453-5000 1100 112TH AVE NE, SUITE 500 BELLEVUE, WA 98004 WASTEWATER UTILITY 0 WATER UTILITY BY APP'D DATE jstowell 08/29/2024 4 JValdez 09/05/2024 '' GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. ZQ z \\ 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. /° rJ�O`" ° \, ° 2c'• 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. PROPOSED ROW ' o \ �o % 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS o Boa\\ FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING .. . • Q SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT 27 50' O \ P INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. p _ _ Q P — — 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION _ _ BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A T T ° °� � � NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. T P T T� Q 50 ° o� 13+C 0 /off G G o o� z 0 SD - G G O� o� DESIGNED: APPROVED: I. VANBLANKENSTEIN G. FRANCO DRAWN: A. ZEA CHECKED: PROJECT NO: P.TISSELL E00566E18 CHECKED: CONTRACT NO: K. CHANG YUEN Cxxxxxxxx 0' 20' 40' DEVELOPMENT ENGINEERING Michael Sippo 09/11 /2024 ALE: 1" = 20' S-421413 W-421413 METRO TRANSIT CAPITAL DIVISION DATE: LIM RAPIDRIDE I LINE JUNE2024 King County RENTON SEGMENT DRAWING NO: MET UTILITY PLAN 1 UT.04 G RA 24+00 TO TAL-B 14+00 SHEET NO: OF 195 473 GENERAL NOTES 0 X a z O z w ry J Q z 0 U) X z O z w J X a z O z w Of I w X a z O z w ry LF X 0 z w CD w J X 3 a z O F- z w rK 3' O ry a O N N C2 ry m N N 00 z O z w ry X a Z O z w r' 0 X a z O z w ry i z O Q cn P. a� a a O ry a_ 3: O G X 3 a Z U' J Q X 0 N O N LO CD --- w o Of O m C J ~ 0) Y o �Q w a> rn N O> � m Ul CD o QU c w co w � o � a> X Cq CO CD CD N o O a a- Y O o � X �'�L� w Q U � X O F— W W W W 0 0 M+ W T_ Ljj a- 0 kA/ATFR i\inTP.q 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV TRANSMISSION LINES. 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION ZONE. UTILITY NOTES ADJUST EXISTING MANHOLE TO GRADE RELOCATE UTILITY POLE (BY PSE) RELOCATE VAULT (BY OTHERS) RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) EXISTING UNDERGROUND TELECOM CONDUIT EXISTING UNDERGROUND GAS MAIN (PSE) 40 ADJUST GAS VALVE (BY PSE) 41 RELOCATE GAS MAIN (BY PSE) 42 RELOCATE GAS MARKER (BY PSE) 44 RELOCATE UTILITY RISER (BY OTHERS) 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) GADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) n49 ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) PROTECT EXISTING FEATURE IN PLACE RELOCATE TRANSFORMER (BY PSE) RELOCATE MANHOLE (BY OTHERS) RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) ADJUST JUNCTION BOX OR PULL VAULT TO GRADE 60 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. 07 CITY OF RENTON TO ABANDON WATER MAIN WITH INSTALLATION OF 8" MJ PLUG ON EXISTING 8" VALVE. CONCRETE BLOCKING PER CITY OF RENTON STD PLAN 330.1. CONTRACTOR TO PROVIDE ALL MATERIALS, EXCAVATION, SHORING, BACKFILL AND FINAL ROADWAY RESTORATION. Qg ADJUST EXISTING WATER VALVE BOX TO FINISHED GRADE. 0' 20' 40' 20 SEE LANDSCAPE DRAWINGS FOR IRRIGATION RESTORATION REQUIREMENTS. 34 ADJUST WATER MANHOLE TO FINISHED GRADE. DEVELOPMENT ENGINEERING Michael Sippo 09/11 /2024 ' S-421414 W-421414 AD -READY SUBMITTAL ' DESIGNED. APPROVED METRO TRANSIT CAPITAL DIVISION DATE: M. T W S�c� I. VANBLANKENSTEIN G. FRANCO JUNE 2024 RAP I D R I D E I LINE L�S (425) 453-5000 Q of Sy, � DRAWN: 1100 112TH AVE NE, SUITE 500 �`� 1.� ti�� � A *j BELLEVUE, WA 98004 ,� O King County � z A. ZEA 06/1 CHECKED: PROJECT NO: RENTON SEGMENT DRAWING NO: WASTEWATER UTILITY WATER UTILITY ° "' '1� P.TISSELL E00566E18 METRO UTILITY PLAN 1 UT.05 stowell 08/29/2024 JValdez 09/05/2024 SS/ONAL CHECKED: CONTRACT NO: TAL-B 14+00 TO TAL-B 18+50 SHEET NO: OF WASTEWATER REVISION BY APP'D DATE 1 K. CHANG YUEN icxxxxxxxx 196 473 N M O O O 1 r N 19 a 0 U a Y_ O Z O N U 0 N z O z w O ry N o LU N z dJI Q z 0 X z O z w n' 4 X z O z w J X z O z w J W X O U) N N Z O z w ry X z O z w I 0 X z O z w ry [if' 0 X O U H LU W 2 X Z O z w ry I z O Q u? X O 3 O X 3 Z co 0 O J F__ Q X 0 >. a J O N — O � NI ry o LU 0 ry XO m 00 J M o U a. om ai co LQ cy)o C � D � O C9 0 " LUp v X cq O N ?� O 0 �o0 O c d 0 O _�� 0LU X LL 0-0 w U a X I, J 0 w w V) w w (n I 0 In co M� W I J w Z U Q 10- HO U � O Ll- r u n v o c0 Ln w Q N U N 0 w O M �N O J c00 U7p 0 I� 0 U U N N m O F— ,"� Z LLJ O � — Do F Nw M II �I 0 aY1U TALBOT RD S WATER NOTES 10 ADJUST EXISTING WATER VALVE BOX TO FINISHED GRADE 34 ADJUST WATER MANHOLE TO FINISHED GRADE. AD -READY SUBMITTAL 7 (425) 453-5000 1100 112TH AVE NE, SUITE 500 ja.,ObsBELLEVUE, WA 98004 WASTEWATER UTILITY WATER UTILITY No. REVISION BY APP'D DATE jstowell 08/29/2024 0]FJValdez 09/05/2024 s 0 dHO dH0 w z w ss ss 22+00 DESIGNED: APPROVED: I. VANBLANKENSTEIN G. FRANCO DRAWN: A. ZEA CHECKED: PROJECT NO: P. TISSELL E00566E18 CHECKED: CONTRACT NO: K. CHANG YUEN CXXXXXXXX dHO \w Z V-) 00 II In _ U � N w w o°� w 0 0 \ (D O (n vo cl- r > U-) p > a U N r7NNnl N II Z 0 Z Lli ry m LIM King County METRO GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV TRANSMISSION LINES. 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION ZONE. UTILITY NOTES 20 ADJUST EXISTING MANHOLE TO GRADE 823 RELOCATE UTILITY POLE (BY PSE) 24 RELOCATE VAULT (BY OTHERS) 825 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) 8 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) 28 EXISTING UNDERGROUND TELECOM CONDUIT 8 29 EXISTING UNDERGROUND GAS MAIN (PSE) 40 ADJUST GAS VALVE (BY PSE) 8 41 RELOCATE GAS MAIN (BY PSE) 42 RELOCATE GAS MARKER (BY PSE) 44 RELOCATE UTILITY RISER (BY OTHERS) 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN 8 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) 48 ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) 8 49 ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) 50 PROTECT EXISTING FEATURE IN PLACE 8 56 RELOCATE TRANSFORMER (BY PSE) 57 RELOCATE MANHOLE (BY OTHERS) 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) 59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE 60 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. 0' 20' 40' DEVELOPMENT ENGINEERING Michael Sippo 09/11/2024 U SCALE: 1" = 20' S-421415 W-421415 METRO TRANSIT CAPITAL DIVISION DATE: RAPIDRIDE I LINE JUNE2024 RENTON SEGMENT DRAWING NO: UTILITY PLAN 1 UT.06 TAL-B 18+50 TO TAL-B 23+50 SHEET NO: OF 197 473 O to N O O 0 N N J 0 U is a Y_ O Z O N U N z O z w O N X O z N _j dJI Q z 0 X z O z w Of I X z O z w JI X Z O H z w I J w X O N N z O z w X z O z w �I 0 X z O z w Of I of 0 X O U H w w 2 X z O z w I z O Q X O a �I O X i� 3 ti 0 O J F__ Q X 0 >. a J O N — O � NI o w 0 XO m 00 J F- M o U a. om ai co L Q CY) o LO w v O w I p � v X O N ?� O a � o a) O c d �o 0 o X w v> LL w Q U a X 2i GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. _ 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION Q BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, 00 N WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A co W 441m ° NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. W N o `° `� �S `'> w o 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV m w i i o� = o J �� TRANSMISSION LINES. a z r„ Li o w w L j O 0 �° 0 Q 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND -� cn oU = voz co CO WHEN WORKING WITHIN CRITICAL TREE PROTECTION OS ZONE. o� UTILITY NOTES 00 00 c o S z"Q w — EX ROW a 20 ADJUST EXISTING MANHOLE TO GRADE Q / O N J U m ! 0 � 23 RELOCATE UTILITY POLE (BY PSE) GRAVEL O 0 3 a � 00 II _N N °j00 o o�Q N z a a a (� �� _ o, 24 RELOCATE VAULT (BY OTHERS) 1l, W O U W N j I� RASS Cl) w oa N m l I co ^ a N 25 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) LLJ CONC o v� �o ow o �� 0 `� CO m N z �' 0 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) GRASS z-N�mN°�'� �� �000 v~i �� �Q wL v N m - II — A W g I N N N N N N^ N U -- y0 W w W W g N N^ Q '"JT�`VJ 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) Cp — ONO" r7 W" NN —N �� N _ V m" `N --0 28 EXISTING UNDERGROUND TELECOM CONDUIT 00 Co dy �S` m 0� _ ICI ICI I00 NI g rn z W d m ! a c C/) �� a o�� _- U�� a z o Lu N 0 w w �� m _w W o w ¢ 29 EXISTING UNDERGROUND GAS MAIN (PSE) �Q �p� opco W� — o � , � 40 ADJUST GAS VALVE (BY PSE) rz � � ICI ^V N S CONC !7J CONC 41 RELOCATE GAS MAIN (BY PSE) oCOCO dy0 SD SD SD SD SD 42 RELOCATE GAS MARKER (BY PSE) 27 50 ode w W d1 S 44 RELOCATE UTILITY RISER (BY OTHERS) r y� 1 � � - 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING 33+00 34+00 "0 3 + 36+00 B E N SO N D R S S R 515) 37+00 38+00 AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN d 1 I (TAL-B-LINE) I 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) SS y0 48 ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) / L� LLj � a a a S z :U d I 49 ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) a c> _ SS y0 50 PROTECT EXISTING FEATURE IN PLACE z li °� CIS W �'' �°°`°�, 50 S aS � ���� as ��� a �S d CS ~ z II u n aS M CIS 56 RELOCATE TRANSFORMER (BY PSE) O W ^^ W �WWz G W W W '� y0 CONC 57 RELOCATE MANHOLE (BY OTHERS) CONC W W W - WOD Q) W aS 6' cLF N � 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) mm dH0 ONNN6 p v — — — — — — — — m o 59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE w W EX ROW d ��C 9 I�� _ °' REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL m 27 ,50 > � do 0 LU 0 P 0 Q "' 28 5O m m — m W W WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN >o� o �c�U o w- 2 �� N a a w _ m 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND z 00 o a• o cc m W o? cc RELOCATION OR ABANDONMENT WITH OWNER. _O � � � (i7 Vl W v (/� U ����� rnN�� NNa O -DA W ti co U z 8 II O W O ��N�� _N II [if_�� C� cn U - o m m II— z � Of 0 ��� o W Z W WATER NOTES O I �� O m -� co C) W— � m l o =wn af 1 c� 0 z v� - w 0 O��^ WW � � I I Q8 ADJUST EXISTING WATER VALVE BOX TO FINISHED GRADE. wW I � o L a V ) c� I Q � bi 2 0' 20' 40' DEVELOPMENT ENGINEERING �- SCALE: 1" = 20' Michael Sippo 09/11/2024 U S-421416 W-421416 AD -READY SUBMITTAL ' DESIGNED:APPROVED. METRO TRANSIT CAPITAL DIVISION DATE: Mv�/T ISSFI 1 I. VANBLANKENSTEIN G. FRANCO JUNE 2024 (425) 453-5000 Q OF S/y, DRAWN: RAP I D RI D E I LINE 1100 112TH AVE NE, SUITE 500 ti � King County BELLEVUE, WA 98004 o � z A. ZEA 06/1 � CHECKED: PROJECT N0: R E N TO N SEGMENT DRAWING N0: WASTEWATER UTILITY WATER UTILITY o O SFGISTP �G\��� P.TISSELL E00566E18 MET UTILITY PLAN 1 UT.07 stowell 08/29/2024 JValdez 09/05/2024 � S/ONAL � CHECKED: CONTRACT NO: T" L-B 33+00 TO TAL-B 3H+OO SHEET No: OF No. REVISION BY APP'D DATE 1 198 473 K. CHANG YUEN CXXXXXXXX 0 U a Y_ O Z O N U 0 N z O z w 0 X N z 0 z N _j dJI Q z 0 z O z w Of I X z O z w JI X z O z w I J w X 0 N N z O z w �I X z O z w 0 X z O z w Of of 0 X O U H w w X Z O z w I z O Q X O a 0 00 z o O � J 7 O 0 a a J O N — O � NI o w 0 XO m 00 J F- M o U a. om ai co L Q CY) o "' o w 0 '' w p a v X Cq O N O a � o a) O � c d =O w v> L� w Q U a X 2i GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION G BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A 50 NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. d v o �o v v S6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV ,A n �� Q-�C" o �, !� oo�d TRANSMISSION LINES. f �\ `A - '`A' 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND \\ d \ �\ \� \ VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION Cp ZONE. EX ROW ��� �o Q � UTILITY NOTES �d voJ P O a o l2Li SS p� Q \ 20 ADJUST EXISTING MANHOLE TO GRADE �.'� 23 RELOCATE UTILITY POLE (BY PSE) CONTRACTOR TO ` p c�'6. l d ��� °p �u �� d VERIFY IN THE FIELD °��� °v��s ° 24 RELOCATE VAULT (BY OTHERS) 00°d 25 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) 9 cl. 0 > do oJ, Ch \ °��� o 0 d 00 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) \\ "� `l. I � >� > o O "zc v v y 0-, d d y 0 �' d 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) 36 0 ° 29 50 =� " �'�. �o a o ° �- ° °' � 28 EXISTING UNDERGROUND TELECOM CONDUIT 0 0 0 - 0 \\ o \ , "�. PROP ROo p \\ "! �� �y °� ���� �00 \� °� �y ? (PSE) 29 EXISTING UNDERGROUND GAS MAIN PSE o� Col °y \o • • 50 \� �o�d o a `90 �- f �oJ� d do \r- y �, '�� `'� J 40 ADJUST GAS VALVE (BY PSE) 29 50 ��' EX ROW _ — 41 RELOCATE GAS MAIN (BY PSE) `�'� �� 42 RELOCATE GAS MARKER (BY PSE) S o ad � M O _ M __ as P as OS o M M — as +00 44 RELOCATE UTILITY RISER (BY OTHERS) as 0_ 2� 50 `(7S CIS 0s ---- - 0s as — 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING TALBOT RD S o 59 °y 8 29 50 28+00 29 50 AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN o 0 � ss ss 2 27+00 _ _ � � e - 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) (TAL-21-LINE) oy 36 50 28 50 27 50 e 48 ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) J — _ d ADJUST JUNCTION BOX OR PULL VAULT M M c�' � � - � J 49 (BY OTHERS) 1 1 d ��l o Ho 1 Ho dH0 1 dHo 1 Ho 1 0 �Ho 50 PROTECT EXISTING FEATURE IN PLACE dH0 d d — — — — — 56 W RELOCATE TRANSFORMER (BY PSE) 28 50 — — — — - - — — ` .o.d ��0 u 7 �°dam�� 57 RELOCATE MANHOLE (BY OTHERS) EX ROW ° � � `niPo�vZ� � � \v� 0 o,do add o �'>��`'�- oy� �`�� °' � � � '�. �- a d y O � v 28 50 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) 313213NO3 �� o o p '6 �> q° 42 o O O o >oy r �o d �° d�� \� d d uZ 5�- °o y d fo 50 ° ��`'� �� 59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE M� EX ROW �. - \\ "cA. Zl p d0 o d \\ O \\ > O \\ .o o. o o �, y , 0 3- d � > \ o �o o� I 60 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL > 6 v> z 1> °JC6 / `p �\ cif\ v doy� oyti cP 3Cb� \\ o �Ni6nlrSa _j� WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN o \1�7 0�� o� ti PROP ROW y d LL.I � �s I 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND o d0f tiro, 29 50 50 do I V z> COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. Ow I 50 o o I �.._. 0 \ \ � EX ROW `tom O I 8 ww w o O WATER NOTES `QQ 8Q ADJUST EXISTING WATER VALVE BOX TO FINISHED GRADE. \ �o APPROXIMATE LIMITS OF UTILITY SETTLEMENT AND VIBRATION MONITORING. SEE \ o> �'� \ \ SPECIFICATIONS FOR VIBRATION AND SETTLEMENT MONITORING. �o \ d \ O- / 0' 20' 40' i DEVELOPMENT ENGINEERING � SCALE: 1" = 20' Michael Sippo 09/11 /2024 S-421417 W-421417 DESIGNED: APPROVED AD -READY SUBMITTAL ' 1.VANBLANKENSTEIN G. FRANCO METRO TRANSIT CAPITAL DIVISION DATE: 9. / JUNE 2024 v�/T ISSFI � I. (425) 453-5000 Q of SDRAWN: RAP I D RI D E I LINE 1100 112TH AVE NE, SUITE 500 �`� `" ti L King County BELLEVUE, WA 98004 o U) z A. ZEA 06/1 2 CHECKED: PROJECT NO: R E N TO N SEGMENT DRAWING NO: WASTEWATER UTILITY �'Fjwvaldez ATER UTILITY ° �FGd/QTP\", ���� P. TISSELL E00566E18 MET UTILITY PLAN 1 UT.08 jstowell 08/29/2024 ' 09/05/2024 � SS�ONAL G CHECKED: CONTRACT NO: T/qL-21 24+00 TO TAL-21 29+00 SHEET NO: OF 199 473 No. REVISION BY APP'D DATE _ K. CHANG YUEN CXXXXXXXX U 0 0 12 z 0 z w 0 fy X z 0 z w JI Q z 0 x z 0 z w n' 4 X z 0 z w JI X z 0 Z w I J LU 0 N N z 0 z w ry �I X z 0 z w ry 0 X L� Z 0 z w ry ry I 0 X 0 U H LU w X Z 0 z w ry I Z 0 Q u? X 0 ry a 0 X 3 rn 0 O J � Q X Z 0 >. a J O N — O 0 NI _0 ry o w ry x0 m CC) J M §E 7> coo U � a. C) m ai Q0 LQ cy)o "' o w v M LUI O � a v X O N ?� O a � o a) 0 � c d 0 O 0 o X LLJ (n �IF---LLU LU0 0-0 U a X 54+00 r it (0) o '2v z �� r 55+00 o� O o) 0) � SON _3 \ A//�\_ r\/ P'1!\14/ 0 EX ROW AD -READY SUBMITTAL 7 (425) 453-5000 1100 112TH AVE NE, SUITE 500 BELLEVUE, WA 98004 WASTEWATER UTILITY 00%fj JValdez 09/05/2024 WATER UTILITY No. REVISION BY APP'D DATE jstowell 08/29/2024 191 GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. S� G'� / 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV o Q �o TRANSMISSION LINES. 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND j VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION ZONE. UTILITY NOTES \o �, 20 ADJUST EXISTING MANHOLE TO GRADE \r, CO (V JRD om����� �" � / 23 RELOCATE UTILITY POLE (BY PSE) � 24 RELOCATE VAULT (BY OTHERS) �� O \ �J ^`v/^`o� 25 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) O moo. r ,� /�°'� ,� Q �0 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) O o �Q�``��_�4�� CO 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) (�N 28 EXISTING UNDERGROUND TELECOM CONDUIT co 29 EXISTING UNDERGROUND GAS MAIN (PSE) CO CO 40 ADJUST GAS VALVE (BY PSE) N /cv �v 41 RELOCATE GAS MAIN (BY PSE) T 0 0 T � _ 42 RELOCATE GAS MARKER (BY PSE) Q - SD O 44 RELOCATE UTILITY RISER (BY OTHERS) Q cw _ 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING r W M AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN N 29 50 � 58+0&- 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) a SS 48 ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) G - G G SS 49 ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) � 5 G G 0 50 PROTECT EXISTING FEATURE IN PLACE h _ OHP 56 RELOCATE TRANSFORMER (BY PSE) Y OHP N O _ 57 RELOCATE MANHOLE (BY OTHERS) O 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) 0 O oe 59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE N REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. 0' 20' 40' Fic VELOPMENT ENGINEERING SCALE: 1" - 20' hael Sippo 09/11 /2024 tj S-421418 W-421418 DESIGNED: APPROVED: METRO TRANSIT CAPITAL DIVISION DATE: I. VANBLANKENSTEIN G. FRANCO JUNE 2024 DRAWN: RAPIDRIDE I LINE A. ZEA LQ King County CHECKED: PROJECT NO: R E N TO N SEGMENT DRAWING NO: P. TISSELL E00566E18 METRO UTILITY PLAN 1 UT.09 CHECKED: CONTRACT NO: TAL-21 54+00 TO TAL-21 59+00 SHEET NO: OF K. CHANG YUEN CXXXXXXXX 200 473 U 0 0 12 z O z w 0 X Z O z w JI Q z 0 Z O H z w Of I X z O z w JI X Z O z w I J w M t7� O N N z O z w ry X z O z w ry 0 X z O z w ry r' 0 X 0 O U H LU w 2 X Z O z w ry I z O Q X O ry a O x z o C� J =D Q X 0 >. a J O N — O 0 NI _0 ry o w ry x0 m CC) J M §E 7> c000U� a. C) m ai Q0 LQ cy)o LO w 0 M w O a v X O N ?� O a � o a) O � c d 0 O _�� 0 X �I�__ LLC7 0-0 w j of Q U a x N GENERAL NOTES ql 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. N 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. r � w N I 0 0 CL_1 1 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION N I O N-N N I I BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, a a a z o �c I WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A ly-" 1 0 7�1 ' I NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 6 _ N 11 11 m as dacn N 11 f m o Q I I I 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV I _� OW 6� I W 1 j 5'� z I d� �N N^N TRANSMISSION LINES. I M I w I I I r 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND ~� � I� I` 0 - I n a v 0 n? 11 m z � � N o VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION I Uw __3 I-�O`N co UU Zm [LG- NN 6 w n w w n M � a C, cn I 0 N co �_j c�> 6j 6I 1�`n ZONE. �/i U) d N O N- pU VJ c na° a cr��� a_zo �� NNE I owww� UTILITY NOTES i� I O UU fin- U ��� " �� E- o)cq II I 0c) NN cn--- r� NU>> f� �U U M d c9 U _�' 00� zn n II �� dDl-I r7� �-Q 7 r7��� 1 611�-�N IN c0 U F-�'6' (n �- c9d' II 1 o c =� 6 N N 10 17 N HdSb �_ N 11 1' °- ° I 20 ADJUST EXISTING MANHOLE TO GRADE M -Lo - n rn N m�� z d i c, N N E (5 W f� ap U NN r 1 �� �� a Nr�r aj 11= ` " UU ��p UUU f-o�6 11 F-N a0 U ��6> c9 �_wW �- ��'_ aN m lil-`11 zZi c~/1 O' O s- II �, r� U: N O 0 r w / I� n I cnj N N N N o o a 0 0 6= N 11 - 50 N w cn 0 CD 23 RELOCATE UTILITY POLE (BY PSE) II 1^ 1� - 11 II U 11 to F O O 6 �j °� S z j In " Nk. 1 �NO� 11 '� O _ w - Ir-zln zd W ~616i II d [' �' �i�0 (nIJiJWwww 11 I N ��!� O C� n w w w m Jo 0 m �w00 _ _ \ JI Y I w / 24 RELOCATE VAULT (BY OTHERS) O N w w- 6j 11 a �- �-F Q I m 11 I,1 z Q 0 p 201 ,� 9 o m z 1 1 < U w cn I �- a 25 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) d Q 1 �www�n / \ / Y oww_wv mo \ U < ZZ " `n I EX ROW / \ \ o ssb�s z / ~ 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) N o ssb�� 50 23 I E" �Q o Ln / \ V s, , , , , • o U I_ ___— — — — _ _ — _b_c�_`.� •• ••OM / A � o�QM 27 EXISTING UNDERGROUND ELECTRICAL CONDUI T PSE SS V) U) z SS 28 EXISTING UNDERGROUND TELECOM CONDUIT SS ONOO \BLOCK WALL dH0 OdH0 0 29 EXISTING UNDERGROUND GAS MAIN (PSE) AD -READY SUBMITTAL No. I REVISION so (425) 453-5000 1100 112TH AVE NE, SUITE 500 cobBELLEVUE, WA 98004 WASTEWATER UTILITY WATER UTILITY BY APP'D DATE jstowell 08/29/2024 '9 E Valdez 09/05/2024 I ADJUST GAS VALVE (BY PSE) N RELOCATE GAS MAIN (BY PSE) r RELOCATE GAS MARKER (BY PSE) p O RELOCATE UTILITY RISER (BY OTHERS) p REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING r N AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) a ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) N \ I z`zz 1 29 50 8 �u 50 PROTECT EXISTING FEATURE IN PLACE p 28 =50J 1 Q w 28 50 56 RELOCATE TRANSFORMER (BY PSE) N - N / 0 �M O �- 11 rnUU00) N p M 11 \ 57 RELOCATE MANHOLE (BY OTHERS) 28 48 o_O�cl- o�N� n- p _ w N nl E E. N � a o 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) 0 ~ N M N o w I U m I / 59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE N n cn z = o z w w w 60 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL M w WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN J w J CM z > 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND U I COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. I 1 WATER NOTES 8Q ADJUST EXISTING WATER VALVE BOX TO FINISHED GRADE. 19 ADJUST WATER METER TO FINISHED GRADE 0' 20' 40' DEVELOPMENT ENGINEERING SCALE: 1" - 20' Michael Sippo 09/11/2024 Wo S-421419 W-421419 DESIGNED: APPROVED: METRO TRANSIT CAPITAL DIVISION DATE: I. VANBLANKENSTEIN G. FRANCO JUNE 2024 DRAWN: RAPIDRIDE I LINE A. ZEA LQ King County CHECKED: PROJECT NO: R E N TO N SEGMENT DRAWING NO: P. TISSELL E00566E18 METRO UTILITY PLAN 1 UT.10 CHECKED: CONTRACT NO: TAL-21 71 +50 TO TAL-21 76+50 SHEET NO: OF K. CHANG YUEN CXXXXXXXX 201 473 I a Y_ O Z O N U N z O z w O fy N z 0 z N _j dJI Q z 0 x z O z w n' 4 X z O z w JI X z O z w I J w X 0 N N z O z w ry X z O z w ry 0 x z O z w ry r' 0 X O U H LU w X z O z w ry I z O Q x O ry a �I O x 3 Z 0 J =D Q x O >. a J O N — O � NI o w 0 x0 m CC) J Cl) o U a. C) m ai Q0 L Q CY) o LO w v co w I p � aa, x O N O a � o a) O � c d =O 0 0 X w v> �I - LL w Q U a X as � 0 O " O Cl C� O j �\\ \0 p \�O O�cJOv ! \� v2 2O�� O c�\\ \i✓ aG v dO.7� O0 0c70 �• �v `Pz �n`vc� � O s Vol' 7 c• 7p v (� 0 O O G ✓ v v O `Z O O v> p, 6. S� \\ �, v o O O 0O Z `Z 'cam• �. O �� v 1.�o� \\o dS'O `P�'o soo c� >' ��p.cA, o ov-� O ��oZ� �o oS �ZJO \\�2�� c� �c��v\07 '�o�� \\o \ �c� O\\ \\ \\gip✓ �� f9 -z o 0\0 `" _ r n� p �� 9 rn`�.� NSi�pc. 9 0 o z✓� o �CD o_��o 6- O 0\0 O�\o � CDz✓�V o 0 50 0S CIS vo Cl s-o"o p S 27 50 cps o 50 �27 45 PROP ROW, 5O o `'� m�N y��ED o\\� -NVM SO O J ON00 ,9 �. N 9 N IiVi O]A m 7i o <- EX ROW �� =o a v HdSV 31 EX ROW 0 V ONOO — -- --4iIII --— das -- �___ — U 1 1 1 I 2 50 29 150 Z �p 16° DI w TALBOT RD S _,,-_ sM - -- M 86+00 87+00 40 8 00 ,\ �o 90+00 M 91+00 — — —I — — (TAL-21-LINE) 50 28 50 50 C5O 29 50 50 27 ��I p 50 27 50 ss ss ss ss Ss SS ss ry s ss ss N b1d03A NOIIVIADAA --- - — — — — — — — —' dHO — = d ONO3 1 — — sd� PAN `00 ssdN oNoO :� d 0 1 P 50 50 27 EX ROW L�Ia ssd�oHidd i�lN ° 1 No di33AA coSSVJO � � c� -0- � v SSb� .o d WVb o 1 1 d A V?� — z � v>, O o O \\ z �0`9 ✓moo ��� Q z 40 g d 28 50 �•�O , \\ 7p 0 `O I `03 O -� In CA O l y� m �' D\! "10 rn Z cp o zco 60 O O r p o p \\ O p Zvi r �N 0 O � ) i9 O GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV TRANSMISSION LINES. 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION ZONE. UTILITY NOTES 20 ADJUST EXISTING MANHOLE TO GRADE 823 RELOCATE UTILITY POLE (BY PSE) 24 RELOCATE VAULT (BY OTHERS) 825 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) 8 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) 28 EXISTING UNDERGROUND TELECOM CONDUIT 8 29 EXISTING UNDERGROUND GAS MAIN (PSE) 40 ADJUST GAS VALVE (BY PSE) 8RELO41 CATE GAS MAIN (BY PSE) 42 RELOCATE GAS MARKER (BY PSE) 44 RELOCATE UTILITY RISER (BY OTHERS) 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN 8 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) 48 ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) 8 49 ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) 50 PROTECT EXISTING FEATURE IN PLACE 56 RELOCATE TRANSFORMER (BY PSE) 57 RELOCATE MANHOLE (BY OTHERS) 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) 59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE 60 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. 0' 20' 40' DEVELOPMENT ENGINEERING SCALE: 1" = 20' Michael Sippo 09/11/2024F—S-421420 W-421420 AD -READY SUBMITTAL ' DESIGNED:APPROVED. METRO TRANSIT CAPITAL DIVISION DATE: JUNE 2024 Mv/T ISSFI I. VANBLANKENSTEIN G. FRANCO (425) 453-5000 Q of Sti, DRAWN: RAP I D RI D E I LINE 1100 112TH AVE NE, SUITE 500 ti � King County BELLEVUE, WA 98004 o A. ZEA U) z 06/1 2 CHECKED: PROJECT NO: R E N TO N SEGMENT DRAWING NO: WASTEWATER UTILITY WATER UTILITY o O ��GIS15�'O) P.TISSELL E00566E18 MET UTILITY PLAN 1 UT.1 1 jstowell 08/29/2024 JValdez 09/05/2024 SS10NAL G o. CHECKED: CONTRACT NO: TAL-21 86+00 TO TAL-21 91 +00 SHEET NO: OF K. CHANG YUEN CXXXXXXXX 202 473 � GENERAL NOTES U 0 0 12 z O z w O fy X z O z w JI Q z 0 X z O z w n' 4 X z O z w JI X z O z w I J w _. O N N z O z w ry X z O z w ry 0 X z O z w ry r' 0 X O CO LU w X Z O H Z w ry I Z O Q X O ry a �I O X 3 Z N C.� X 0 >. a J O N — O � NI ry o w ry XO m CC) J Cl) §E 7> coo U � a. C)_ m ai `9 E LQ Coo L- 0 w 0 v M w I p � a v X O N O 0 �oa) O � c d 0 O 0 X �IF --- LLC7 w U a Q X SS ss \ ss 'F ° so rVo CIO o o-. s N'`G Lip 9�p,�S9 s — CRASS °�� p�9 EX ROWS J 41 0 J VL ' Qy0 G 10" RESERVOIR P'VC AIN LINE DIRECTLY ABOVE 20" DI W ON =20" DI W 50 / 5� 5� / / T c GO J cyl ti F� CSC CONC �Q GRASS AD -READY SUBMITTAL 7 (425) 453-5000 1100 112TH AVE NE, SUITE 500 BELLEVUE, WA 98004 WASTEWATER UTILITY WATER UTILITY (D No. REVISION BY APP'D DATE jstowell 08/29/2024 JValdez 09/05/2024 "6 �60 pig\ �69, p �s S0>`� Amp DESIGNED: I. VANBLANKENSTEIN DRAWN: A. ZEA CHECKED: P. TISSELL CHECKED: K. CHANG YUEN APPROVED: G. FRANCO PROJECT NO: E00566E18 CONTRACT NO: CXXXXXXXX o�4� o17- A LIM King County METRO 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV TRANSMISSION LINES. 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION ZONE. UTILITY NOTES ADJUST EXISTING MANHOLE TO GRADE RELOCATE UTILITY POLE (BY PSE) N r RELOCATE VAULT (BY OTHERS) 0 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) 0 r RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) N EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) L0 EXISTING UNDERGROUND TELECOM CONDUIT EXISTING UNDERGROUND GAS MAIN (PSE) ADJUST GAS VALVE (BY PSE) N RELOCATE GAS MAIN (BY PSE) r RELOCATE GAS MARKER (BY PSE) IQ O RELOCATE UTILITY RISER (BY OTHERS) REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING N AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN N RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) a ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) 50 PROTECT EXISTING FEATURE IN PLACE O 56 RELOCATE TRANSFORMER (BY PSE) N RELOCATE MANHOLE (BY OTHERS) 0 0 588 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) 0 59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE N N 60 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL a WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN J 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. 0' 20' 40' DEVELOPMENT ENGINEERING SCALE Michael Sippo 09/11/2024 •' S-421421 METRO TRANSIT CAPITAL DIVISION RAPIDRIDE I LINE RENTON SEGMENT UTILITY PLAN CAR 32+00 TO CAR 36+50 "=20' W-421421 DATE: JUNE 2024 DRAWING NO: 1 UT.12 SHEET NO: OF 203 473 0 U a Y_ O Z O N U 0 N z O z w O X N 0 LU N JI d Q z 0 X z O z w Of I X D O F(F T7 X 3`3g 7 72'Cp g S&Mp 72 ,Cp p ,338 4A z O z w ry J W 0 N N 00 z 0 \ z w X z O z w 0 X z O z w ry r' 0 X (6 O U H w w X z O z w ry I z O Q X O a O X 3 Z C7 � J X 0 >. a J O N - O � NI o LU 0 XO m CC) J Cl) o(_5 a. C) m ai Q0 L Q CY) o iz 0 v M W I p � a v X O N ?� O a a) o 0 O � c d �o 3: 0 X I F --- w LL Q ~p w Q No. U a X � „gyp\ ,C -'7�'�' 32� Sp 4 A SAC 0" CQ" 72 39 GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV TRANSMISSION LINES. 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION ZONE. UTILITY NOTES 20 ADJUST EXISTING MANHOLE TO GRADE p S "Ec °pp So g3 ° p 7 S U e 23 RELOCATE UTILITY POLE (BY PSE) FD'33g� c�,G' rE7F�Sje T7 R7 70 pl,cc 73'R2g 24 RELOCATE VAULT (BY OTHERS) 7 rF(S �)rIv 3 34 342 8 tij s q �q } 7S w0010 p yT TU ST 0 0 IN 442 ° , ' 72 .> C 84 , 0 q 50 °Sr " °k°p \ 8 25 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) �Mp73 cMA pq / 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) N 47•s' 28 50 EX ROW sT1 Rk7Nc %10 V 4' WOOD x ��RF / ASPH R28 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) 4 4 S P11�NTE m� BILLBOARD ASPH PLANTER 0 4 4 — — Q 1 4— — ��VV _ oyp EXISTING UNDERGROUND TELECOM CONDUIT— R7°yT SD ° — — ASS ASPH y 29 EXISTING UNDERGROUND GAS MAIN (PSE) 0 Cole C 40 ADJUST GAS VALVE (BY PSE) �y CRASS 41 RELOCATE GAS MAIN BY PSE )yr� CONC 33 --- == - -_ w9- 03, 347 3302, 7(),,p32' 0 CONC r p�c coNc I I 42 RELOCATE GAS MARKER (BY PSE) 0 8 50 28 48 50 e�8 2ti0�F 44 RELOCATE UTILITY RISER (BY OTHERS) Q � HA � Is 20 -- 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING r 7F SSM 7FiSw)� 3 9. S rM 34> S Aqr�/h'� 0 45 0 S E CARR�Rp/7 a 29 5O � AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN 50 I _ _TNo �0 46+00 a 44+00 L_ w 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) (CAR-LI N E)7 / o - _ 47+00 pti Tyo� 29 50 50 29 50 ',S \ 40 47 28 5O �— coM2 F 48 ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) 2., M 49 ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) — SD �I p T T T S� �, 47,s � � T I T CO °�F 8 � SS COMMA T T T D 50 PROTECT EXISTING FEATURE IN PLACE ROLLE RB 20 '43' T SD CT� SS W — F — — _ I W W _ 1, 1 T — S� 56 RELOCATE TRANSFORMER (BY PSE) N — _ _ _ _ _ _ orYc — — 1 57 RELOCATE MANHOLE (BY OTHERS) 0 NC 0 _ T T T T P cT IRAs EX ROW W 58 RELOCATE JUNCTION BOX OR PULL VAULT BY OTHERS T P T ' C� 8 wF� 2 ( ) O 73, ICV 28 47 w NO REF 'FUR 72» R 50 2763 7 E 59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE N 50 _ Q R 5 — — — \6� Spy TEXACO � �� — SID — Fc �7 R772� / wE< f G REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL 20 19 g / 5 S— PROPANE TANK — _ WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN r1 r1 .1 / � _ el�) c� / / / - / CCU 9. CII I CTATirlNi 's0°c�r�4 CONC BLOCK EA RUVV U, 0„ , v qR o ,c � c"SS' _ espy SD S � k o p PROPOSED ROW / 6•. 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND 3g 5' CHAMUNK SD 0 COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. p�c s T oMy r 27 50 2 " 28 50 7� / �� 58 O Q I STATION o s" cMp S S SD R7M7� CqG SsC qp r�/y 7 I / E O w ION I s�(Nw� 3' 6J 48 0 4S R28se As �� F� I I �e ROckERr 7 q jA7 Mp\ 3 j4 2 S / SAC SID l F�SF)\ T2 R7 33`3 0 9 72 „ 6 7 / e 7F(s) e T7 r F�"EJ� 33S �� 34 p 1F �S)\ T7 Rr 6' SUti1p 336R1t7, F(SW) 33Ss'6..�64. MATCH LINE 105TH 1 1 +00 — SEE SHEET 1 UT.14 r��r" 3 aS s SUM \336 3 72 , 077) 33S g a 4 p�C 07 SQ k /F ce T 14A�, WATER NOTES Tops3R,3 E 8g' 7F� My T2 T� c So Q8 ADJUST EXISTING WATER VALVE BOX TO FINISHED GRADE. 19M,s c F�>872 ADJUST WATER METER TO FINISHED GRADE. 20 SEE LANDSCAPE DRAWINGS FOR IRRIGATION RESTORATION REQUIREMENTS. 0' 20' 40' DEVELOPMENT ENGINEERING SCALE: 1" = 20' Michael Sippo 09/11/2024 UFS-421422 W-421422 DESIGNED: APPROVED. METRO TRANSIT CAPITAL DIVISION DATE - AD -READY SUBMITTAL onJUNE 2024 W PEA- MISSFI I. VANBLANKENSTEIN G. FRANCO (425) 453-5000 Q of Sy, DRAWN: RAP I D RI D E I LINE *Jaco 1100 112TH AVE NE, SUITE 500 L14 King County sBELLEVUE, WA 98004 o U) z A. ZEA 06/1 2 CHECKED: PROJECT NO: R E N TO N SEGMENT DRAWING NO: WASTEWATER UTILITY 0 G/sTG P. TISSELL E00566E18 MET UTILITY PLAN 1 UT.13 REVISION BY APP'D DATE jstowell 08/29/2024 SS7ONAL �� CHECKED: CONTRACT NO: CAR 42+50 TO CAR 47+50 SHEET N0: OF K. CHANG YUEN CXXXXXXXX 204 473 Z O z W ry 3I O X Z O z W J Q Z U� X ai Z O z W n, X Z O z W ry J X Z O z W I J W M O ry U? m N N O1 Z O z W ry �I X Z O z W ry p X Z O z W ry ry I p X m O CO U H LU LU 2 X Z O z W ry I z O Q X O ry a �I O ry X 3 Z � C7 J � Q X o >. a J O N — O � NI ry o W p ry XO m CC) J Cl) o U > . C:)_ m ai `9 E LO 0 CY) p �j00 M Z W 3: co 0 " LUp J aa, x O N O � O a) O � O d 0 O o p X 2� W (n �I LL C� 0-0 W Q U a X 2i I a Y_ O Z O N U N z O z w O fy N o LU N JI d Q z 0 X z O z w n' 4 X z O z w I J X a� z O z w I J w X O N N z O z w ry �I X z O z w ry 0 X z O z w ry ry I 0 X O U w w X z O z w ry I z O Q X O ry a O X 3 Z C.7 J =D Q X o >. a J O N — O � NI ry o W 0 XO m CC) J Cl) o U a. C) m ai Q0 L Q CY) o LO N W v M W I p � aa, x O N ?� O a � o a) O � c d �o 0 0 X 3: w v> 3I�__wC7 0-0 w Q U a X IWN 0.65' IN MON CASE 8.5' CHAINLINK EX ROW � � o 0 0 FND 1 3/4" BRASS DISC W/PUNCH DOWN 0.JINMON CASE— — - — — VE AHEAD CONC W� W�� W SD W S 23+00 SE 180TH ST 24+00 SD 25+00 (105TH-LINE) � D D CONC Ib P P CULVERT IE 8" ADS (S)=385.0' SDCB T1 RIM=383.30' IE(N)=380.9' 12"CMP SUMP=379.6' GATE IN PEDESTRIAN GUARDRAIL PROVIDED TO PROVIDE 3' CLEAR ACCESS AROUND HYDRANT. SEE DWG 151.25 & DETAIL D ON 156.02 0 SDCB T1 RIM=383.40' IE(S)=379.7' 12"CMP IE(E)=379.6' 12"CONC IE(W)=379.6' 12"CONC SUMP=377.9' /�-- CURB DESTROYED ASPH FULVERT IE 48" CMP (W =381.2' GRASS 3' METAL HANDR IL ST P ik, VANTAGE POINT APTS 26+00 34 CULVERT IE 48" CMP O- SD f- c We ASPH 3' METAL HANDRAIL w FT 7 7`�Vr 0 — P 7_7 L ----------- 6' 129 � CHAINLINK 128 NI7 CROSSWALKEX RO507 DS 50 A NDS NAIL/WASHER II I APS GAS 2 R31 I50"-52" I J WATER NOTES GRASS W w +00 SDCB T1 RIM=388.14' IE(W)-383.3 12"CONC IE(S)=383.2 12"CONC 5UMP=382.5' — SD 50 ) 8' CHAINLINK ASPH CULVERT IE 48" CMP (E)=38 — SD � D SSMH T2 RIM=389.60' — IE7)=375.272"PVC TEL IE(S)=375.1' 12"PVC P SDCB T1 RIM=388.16' j SUMIE(N=38 ,3.5 12"CMP SUMP=383.5' NO PARKING — NAIL/Hue 28 50 APS COM 4 R30 55"-59" Q8 ADJUST EXISTING WATER VALVE BOX TO FINISHED GRADE PER COR STD. PLAN 330.1. / 13 REMOVE AND SALVAGE EXISTING FIRE HYDRANT. / / 34 REPLACE EXISTING FIRE HYDRANT WITH NEW FIRE HYDRANT AND CONNECT TO / EXISTING LATERAL. CONCRETE PAD & BEARING BLOCK PER SOOS CREEK WATER & / SEWER DISTRICT STD PLAN W-5. CONCRETE BLOCKING PER SOOS CRE K WATER & / SEWER DISTRICT STD PLAN W-1A & W-1 B. 0' 20' 40' GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV TRANSMISSION LINES. 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION ZONE. UTILITY NOTES 20 ADJUST EXISTING MANHOLE TO GRADE 823 RELOCATE UTILITY POLE (BY PSE) 24 RELOCATE VAULT (BY OTHERS) 825 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) 8 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) 28 EXISTING UNDERGROUND TELECOM CONDUIT 8 29 EXISTING UNDERGROUND GAS MAIN (PSE) 40 ADJUST GAS VALVE (BY PSE) 8 41 RELOCATE GAS MAIN (BY PSE) 42 RELOCATE GAS MARKER (BY PSE) 44 RELOCATE UTILITY RISER (BY OTHERS) 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN 8 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) 48 ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) 8 49 ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) 50 PROTECT EXISTING FEATURE IN PLACE 8 56 RELOCATE TRANSFORMER (BY PSE) 57 RELOCATE MANHOLE (BY OTHERS) 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) 59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE 60 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. DEVELOPMENT ENGINEERING SCALE: 1" = 20' Michael Sippo 09/11 /2024 5-421424 W-421424 AD -READY SUBMITTAL ' DESIGNED:APPROVED. METRO TRANSIT CAPITAL DIVISION DATE: JUNE 2024 Mv�/T ISSFI � I. VANBLANKENSTEIN G. FRANCO (425) 453-5000 Q of S/y, DRAWN: RAP I D RI D E I LINE 1100 112TH AVE NE, SUITE 500cob `" ti L14 King County BELLEVUE, WA 98004 , o CO z A. ZEA 06/1 2 CHECKED: PROJECT NO: R E N TO N SEGMENT DRAWING NO: 31 WASTEWATER UTILITY �F�isTE�`�� � P. TISSELL E00566E18 METRO UTILITY PLAN 1 UT.15 SS/ONAU CHEHANG YUEN CXXXXXXXX CKED: CONTRACT NO: 1 05TH 23+00 TO 105TH 28+00 SHEET NO: OF No. REVISION BY APP'D DATE jstowe1108/29/2024 206 473 0K. C X o r z N w Q 2 X 1 z O z w JI X z O Z w Of UI H X -a. c 0 m N N Y N N 00 _. 0 N N 3 a 0 z w 0 w J X z O z w Of O O X z J Q CO x 0 N O =D N Of I w 0 O J m o U N Y O U a CC) J M O m C/) I LOQ� I` O - Lq w w cal O C�) aa) O N ?� O a � o a) O c d �o 0 o X w v> wCD w Q U a X 2i ' I GENERAL NOTES I 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS / FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING --- --------------------------------------------- SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 1-10" GATE VALVE, MJxMJ N I 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION cc I BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, co (STA. 29+80.47, 53.39' LT) co r � I WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A CO U) U) I NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 0 0 o z z I �0 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV N a o 0 0� I TRANSMISSION LINES. z 10" DI 45° HORZ. BEND, MJ Q W w U I 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND R w 0 o m �W/ CONC. BLKG J J w � � I I VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION o Xw oc� � Q "' o o � =STA. 29+86.89, 46.76' LT o o I / ZONE. LO CD z - wQ�� zQ� ,$) n wDw=w I m00 � � � � O J � � � � � � UTILITY NOTES z 0 Ln 30 m II a 50 CD�=U 150 II II SUN co o U N W w w N I �� N 20 ADJUST EXISTING MANHOLE TO GRADE N C29 35 N� I ww Naa >-� N � N� O � I Z Z N co N�/J \Ln w �� N� N J o w � Ln 23 RELOCATE UTILITY POLE (BY PSE) V VVV LD Q N N 00 � w ~i �_ ICI m z w 24 RELOCATE VAULT (BY OTHERS) N N V p i N w DO EX ROW w 1 N j �, o w w 25 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) Cn . 1n C7 U fn Z ssddo - �° 0 _ w w ssd�o 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) 4 L Q N N — — C • 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) oNoo 33 LF 28 35 1 28 EXISTING UNDERGROUND TELECOM CONDUIT J aS aS j 29 EXISTING UNDERGROUND GAS MAIN (PSE) 10" DI 900 HORZ. BEND, MJ 28 35 15 LF 50 28 108TH 32+13.38= I 40 ADJUST GAS VALVE BY PSE 0 W/ CONC. BLKG p o I 186TH 12+00.00 ( ) 108TH AVE SE (`b 515) STA. 29+87.47, 23.58' LT p (K28I 28 50 N: 162196.520 41 RELOCATE GAS MAIN (BY PSE) 29 35 I I E:1302938.144 28+00 w 29+00 w 0+00 I 31 +00 32+00 33+00 42 RELOCATE GAS MARKER (BY PSE) J J I — — _ — — — I — — _ — I I (108TH-LINE) 10" DI 900 HORZ. BEND MJ I I J i I I - 44 RELOCATE UTILITY RISER (BY OTHERS) W/ CONC. BLKG 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING 0 50 I 29 50 50 28 50 L 1 STA. 29+96.04, 23.71' LT 1 1 1 I1 1 1 - - 1 1 AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN G C; G G G I G 1 32 n3l - G -- - G G 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) 50 i M — - -- - -- S. C as -inn nn M 48 ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) o - 1 _ 49 ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) 0 dH0 d CD� w dM ��o � U 00 � J a I 50 PROTECT EXISTING FEATURE IN PLACE � N J� p� - a Q o o b�� EX ROW N = N N 00 N Q a M 56 RELOCATE TRANSFORMER (BY PSE) �U�U w� DLO c I 50 7 ��bM ON00 9 m m o z I ' d L N 57 RELOCATE MANHOLE (BY OTHERS) �dM oNoo ,g J a �' U I PROP ROW o w w N 31do ) ='N 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) _ a 0 (D a 29 50 SO 28 � o a a 59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE a a U U U U U U M 00 0 00 a_ 0 50 r a0 00 N N N 60 11 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL r . � I Q z 5O LLJ c� � - WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN _t 00 N N I L� p �O O CO Ln'6 d' d LUJ 2'tUU� U I p HMO O VJ 4cO L2 LI, o > 50 co o O � M � n u � 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND n co I ��in Lj Ln II II II o � z COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. � �,� m II jN o_0�Ln a-2oc�:3�'i00 o O q �aa6 Uwwzww J o� w w w n I Q Q w w ~p a w O ,� �� a CD w �a n »zzmw o o w Q w w Q N N II z w w U 0a!� a_w g 2z ��� U pwwU�U o �� ow W = H Lp Z O w a' V7 < 10 CD Cn � aQ I z w�w�Oz COQ0 � a a� >' o J w wn �a-a� cn °'� Q pp��Q~ EX ROW, C) U r 0 = - - L(7 - ���N� Z a�Ul CC I _ w w T � o N II I U = ~ i w w � �T)IbOj� co D LO 'nw I ----------------------- o - O a dLO � F O--------------- 0 O WATER NOTES ^° m�� z 0 I M o mzU UwwwU I m N ---------------------- o`w I Z 11 REMOVE EXISTING VALVE BOX PER GENERAL NOTE 27 ON DWG 1 UT.OA ONLY AFTER o 31 INSTALL WATER SERVICE PER SOOS CREEK WATER & SEWER DISTRICT STD PLAN W-15 WATER MAIN HAS BEEN REMOVED. & W-20. TAP LOCATION AT WATER MAIN AS INDICATED. METER BOX PER SOOS CREEK WATER & SEWER DISTRICT STD PLAN W-19 AT LOCATION AS SPECIFIED. CROSS BELOW 28 INSTALL NEW 10" DUCTILE IRON WATER MAIN. PROP. RETAINING WALL WITH 2' MIN. CLEARANCE. ENCASE IN SCHEDULE 30 PVC, SIZED 29 INSTALL AND CONNECT TO EXISTING SOOS CREEK WATER & SEWER DISTRICT WATER MIN. 2" NOMINAL DIAMETER LARGER THAN SERVICE LINE SIZE. CASING TO EXTEND 2' MAIN AFTER SUCCESSFUL PRESSURE TEST, CUBING, AND DISINFECTION PER SOOS PAST EACH EDGE OF FOOTING. Z CREEK DESIGN AND CONSTRUCTION STANDARDS - WATER WITH 8" MJ SLEEVE AND 10" DI SPOOL AS REQUIRED. 32 UPON COMPLETION OF NEW WATER SERVICE INSTALLATION, REMOVE EXISTING WATER METER BOX AND ABANDON EXISTING WATER SERVICE LINE. 0' 20' 40' 30 REMOVE EXISTING 10" DI WATER MAIN. 35 NOTIFY SOOS CREEK REPRESENTATIVES AT LEAST 72 HOURS IN ADVANCE OF ANY CONSTRUCTION WORK. WORK SHALL NOT START UNTIL ALL MATERIAL, EQUIPMENT, DEVELOPMENT ENGINEERING AND LABOR NECESSARY TO COMPLETE WORK IS ASSEMBLED ON THE SITE. WATER ;'+ SCALE: 1" = 20' MAIN WORK MUST BE COMPLETED IN ONE (1) WORKING DAY OR OVERNIGHT. Michael Sippo 09/11/2024 F—S-421425 W-421425 AD -READY SUBMITTAL ' 1.VA DESIGNED: APPROVED METRO TRANSIT CAPITAL DIVISION DATE: / JUNE 2024 P�� Mv�/T ISSFI � I. VANBLANKENSTEIN G. FRANCO (425) 453-5000 Q of S/y, DRAWN: RAP I D RI D E I LINE 1100 112TH AVE NE, SUITE 500co LQ King County BELLEVUE, WA 98004 o � z A. ZEA 06/1 2 CHECKED: PROJECT NO: R E N TO N SEGMENT DRAWING NO: WASTEWATER UTILITY O G�STP\"' ��P. TISSELL E00566E18 MET UTILITY PLAN 1 UT.16 No. REVISION BY APP'D DATE jstowell 08/29/2024 SS/ONAL 'r G CHECKED: CONTRACT NO: 108TH 28+00 TO 108TH 33+00 SHEETNO: OF K. CHANG YUEN CXXXXXXXX 207 473 z O z z W N �I x � N z � O z W J W X 0 > C9 N N a 0 z W c� w J X z O z w ry O O ry d �I O x Z U Q X CV � O =D N ry I W 0 a ry m O J m o U N Y H O U a CO J M a o m co I CQ� ti U L0 F- w O w cal o C�) aa) x O O a = o O a �o 8 0 X � w v> wCD w Q U a x 2i EX RC 50 • ■ • • ■ • • . ■ .I -.77 AIR Ks I�i NAM" k" • 51+00 108TH AVE SE (SR 515) _ _52+00 I I I I I (108TH-LINE) 0 �O a �IVN ONVH Q W -IIVH ONVH M (0 Q 0- U r pW00 Ln : �t0�� II II 0- 0 J mC-1 m In Ln cn 1" Z _D �^ m z vl o _ U N II W W as o 00 't CD II II U W l�wW� / \ O 53+00 o� ,o Y ' '�Itl H J II II II O j Uzw� O Q __' =) z co W w W I n O CL O W � - co � E), raj N N � In II \BCD ���L� �nn00 m\ I CD O W N U W U) W Ln �=w� n � z p (n 0 (n W W f/) HdSV Cl 1 c-> co F3 � o w za_ m 54+00 0 I � I 0� V J V J as MO IIV2l ONVH d N U LC) 10 zr__ W \ N p - c V = \ M N EX ROW N N Ln \ � W 50 " Lj O 0 o d O U U p d: O I 0 r (n p N N O It w nz CI_ � II Q Q �' ) � � N v~ O r J LLJ N W O W J > II II C_ CD U ^ r ^ W m Q N r '� z 0 U U z O W F m z n W z Cn O � — Y W � II W d O 0 as ° a nr r U U > >�- - Go CO C0 t_ 0� (! Ln 0- O m n LO II rn Q �U� 6:'- Lc)iN LO >- �ma > W Ul In d- W W W — ��\ J II o m ^a C)wV 3: m w UZd (W�� wwv, owo c' o \ C `i I M PI: 108TH 54+84.92- LL SIJ213d 3ivm N: 159925.702 E: 1302881.111 II 55 'I ode I CO r7 N a- D 6 Cq W U 0No d� V C7 EX ROW M SEE VOLUME 2 FOR CITY OF KENT / IMPROVEMENTS 1 v d d a MO CI_ ssV�]� EX ROW m X MS x \ o\ co O ���� CD CD � CC m N Cc N 't Ln N N 4- t- II II 0 1 (n (n \per (n Q z N N LJ t- 't \ a-�� m��o < U m UU z o II II LLJ Y Q Q Cf) W W < 0_ —1 0U L, Q O � 0_ m W Q m_ 0 GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHALL BE COORDINATED WITH EACH UTILITY. 4. SEE SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT PLANS FOR ADJUSTMENTS, REMOVALS, AND RELOCATIONS OF EXISTING SIGNAL, ELECTRICAL, LIGHTING, AND INTERCONNECT EQUIPMENT INCLUDING CABINETS, JUNCTION BOXES, AND SIGNAL POLES. 5. ALL UTILITY STRUCTURES (MANHOLES, CLEANOUTS, JUNCTION BOXES, HAND HOLES, VAULTS, ETC.) LOCATED IN A SIDEWALK, WALKING PATH, OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID COVER PER PROJECT SPECIFICATIONS. 6. NO WORK SHALL BE DONE WITHIN 20 FEET OF PSE 230KV TRANSMISSION LINES. 7. REFER TO TREE PROTECTION PLANS. PROTECT TREES AND VEGETATION WHEN WORKING WITHIN CRITICAL TREE PROTECTION ZONE. UTILITY NOTES 238 ADJUST EXISTING MANHOLE TO GRADE RELOCATE UTILITY POLE (BY PSE) 24 RELOCATE VAULT (BY OTHERS) 25 RELOCATE JUNCTION BOX OR SERVICE CABINET (BY OTHERS) 26 RELOCATE HANDHOLE OR JUNCTION BOX (BY PSE) 27 EXISTING UNDERGROUND ELECTRICAL CONDUIT (PSE) 28 EXISTING UNDERGROUND TELECOM CONDUIT 29 EXISTING UNDERGROUND GAS MAIN (PSE) 40 ADJUST GAS VALVE (BY PSE) 41 RELOCATE GAS MAIN (BY PSE) DRELOCATE GAS MARKER (BY PSE) 44 RELOCATE UTILITY RISER (BY OTHERS) 45 REMOVE EXISTING PRIVATE UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT (BY OTHERS), SEE LIGHTING PLAN 47 RELOCATE UNDERGROUND TELECOM SERVICE (BY OTHERS) 48 ADJUST EXISTING MANHOLE TO GRADE (BY OTHERS) 49 ADJUST JUNCTION BOX OR PULL VAULT (BY OTHERS) 50 PROTECT EXISTING FEATURE IN PLACE 56 RELOCATE TRANSFORMER (BY PSE) 57 RELOCATE MANHOLE (BY OTHERS) 58 RELOCATE JUNCTION BOX OR PULL VAULT (BY OTHERS) 59 ADJUST JUNCTION BOX OR PULL VAULT TO GRADE 60 REMOVE EXISTING STREET LIGHT UNDERGROUND ELECTRICAL WIRING AND ABANDON CONDUIT, SEE LIGHTING PLAN 61 CONTRACTOR TO VERIFY OWNERSHIP IN THE FIELD AND COORDINATE RELOCATION OR ABANDONMENT WITH OWNER. g C 0Z CD z Q 0' 20' 40' DEVELOPMENT ENGINEERING Michael Sippo 09/11 /2024 SCALE: 1" = 20' S-421426 W-421426 AD -READY SUBMITTAL ' DESIGNED:APPROVED METRO TRANSIT CAPITAL DIVISION DATE: MTISti, JUNE 2024 I. VANBLANKENSTEIN G.FRANCO (425) 453-5000 Q wSI RAPIDRIDE I LINE DRAWN: 1100 112TH AVE NE, SUITE 500 BELLEVUE, WA 98004 o U) z A. ZEA King County 06/1 24 CHECKED: PROJECT N0: R E N TO N SEGMENT DRAWING N0: WASTEWATER UTILITY �' SF�isTEk GP. TISSELL E00566E18MET UTILITY PLAN 1 UT.17 No. REVISION BY Al DATE jstowell 08/29/2024 ' S/oNAL CHECKED: CONTRACT NO: SHEET NO: OF 108TH 51 +00 TO 108TH 56+00 K. CHANG YUEN CXXXXXXXX 208 473 Ln O G_ I� cD cfl � II II II mw\\U z 0 i I; Q CV LO co co cz U) 0 N 00 0 Cz U c v N U7 C 0 O U U o)rY z Q Oo z00 w , of 1 3: LL N O cl IL CU x� Z N o w 0) J N in co 30 J � � N a NI CD_ O w N =, x w O o'(0m�i JCl C=>022 C:) m Y E'm cu LO O U o 3 > N xxil v u) N C, N co 0 0 o w a w Y � 3wxcn �U_w w q a U 0- x 30 EX 10" SD- 20 J LL X J X J LL LL LL] m �> �I wl ---------------- ----------------- oma *�E mmmmmm_ w1m - m E-M I ----------- - ------ ----------------- - -------------- Ek 15, v I I I 1 I I I I- I I I I I I I I I I I I I I I I 1 14+50 14+60 Q 14+80 15+00 15+20 15+40 15+60 15+80 16+00 16+20 16+40 16+60 16+80 17+00 17+20 17+40 17+60 17+80 18+00 18+20 18+40 18+60 18+80 19+00 19+20 19+40 Q 19+60 19+80 20+00 co U) co H- 3 3 S GRADY WAY 18 _ 0 xX x J WATER MAIN PROFILE 1 UT.02 - 1 UT.04 w 0 w U_ = Ili ...................... ........................ .......1L ........ ........ ...................... .......... ........................ .�. ......... ...................... ...................... ...................... ........................ ........................ ...................... ...................... ...................... ...................... ...................... ........................ ........................ ........................ ...................... ...................... ...................... ... ....... LU .............. ......J::................................... .. ...................... ...... .......... �.. .... .... .............. .0a................. >.. .................. FINISHED GRO ND... x................�.................... "'EISTING' ROUND--- ...... . w ............ ................................... ................................................ ........................ . .. .. . . cv ............. ........................ ............................... ........................ .......... . — ........ ..............Q.. .................. . O....................... m ........ .... ..................... ............................................... 5.�IN .OVER............. ................................................ ........................ ............................................................... ..................... � ................................................................................ ..........d..................................... .................................. ........................ .................................. Va ...........................................................................................c)..................... .......................5M.......... c . ....... ... N ............ ............... ...................... ........................ ........................ . ...... ........................ ............................ ........ .......... ..... Imo- ......... ...................... :: ...................... ..................... �................. ....................... ...................... ............. �...... ....................... ........................ ........................ .. N . .... ...... ...................... ......... .... ............... ...................... ..................... ...................... ............ ............ ............. ................ ..... ....................... ...... ............ ............. eq...... 0................ ............. ... ...................... ..... ............ ............ .............. o W Z ..................... Q.................... ........... �......... m......... ............( ..................... Cu.............................................. ........ ........................ ............. .. .......................................... .. .... ........................ ........................ ........................ o................. ... . .................. a,...... ........................ ........................ .............. ....... ........................ ........................... �,...... .... .1. .............. ...................... ..... ...................... �. .. .. ...1.... .. .. +....... ............. ............. ...................... ..... ............ .............A.. .... . . . 20 J 0 `V 0 N ¢ 15 20+25 N 20+50 N 20+75 21+00 21+25 21+50 21+75 22+0 22+25 22+50 22+75 c~n 23+00 23+25 23+50 23+75 24+00 24+25 24+50 24+75 2 25+20 _ 3 4 6U' 3 10 Q S GRADY WAY WATER MAIN PROFILE WATER NOTES 1 UT.02 - 1 UT.04 Q INSTALL NEW 12" DUCTILE IRON WATER MAIN. ° Q CITY OF RENTON TO INSTALL AND CONNECT TO EXISTING WATER MAIN AFTER w w Z 0 0 SUCCESSFUL PRESSURE TEST, POLYPIGGING, AND DISINFECTION PER SECTION 5-14.2 J OF THE CITY OF RENTON WATER UTILITY CONSTRUCTION STANDARDS. CONCRETE 0 ° Q of BLOCKINGS PER CITY OF RENTON STD PLAN 330.1. CONTRACTOR TO PROVIDE ALL a PROP FH CO o o MATERIALS, EXCAVATION, SHORING, BACKFILL AND FINAL ROADWAY RESTORATION. O wF1 0 O w Z Q3 INSTALL NEW FIRE HYDRANT ASSEMBLY PER CITY OF RENTON STD PLAN 310.1. ................ ................................................... ........0 . . .... ................... w ................... ......... o................. ............... w �................. PROP 12 DI SD a ... .. �u... �... ............... .. ............... ...... sCl-.............. w......CONCRETE BLOCKING PER CITY OF RENTON STD PLAN 330.1. 3 a.� .... ................... .W.0.. "" """""""""' ................... ......... """.Rt_.M ' """"' w................. ............. O J................. EX WM TO BE REMOVE a w ... ... PROP 12" D D ::: ::::::.... x . 3 x .w.. w w...... x ... ../-FC- .... .. Q4 INSTALL 1" WATER SERVICE PER CITY OF RENTON STD PLAN 320.1. TAP LOCATION AT . . . . . . . . . . . . . . . . . x.... ........... .........x . W . VERIF IN THEFIEL w_....._ .... `� Ex wM TO BE RE WATER MAIN AS INDICATED. METER BOX LOCATION AS SPECIFIED. :...............: " .............::.. ..: ................. :::.:.......... � � ::::: P P GAS... :: PR P: FH : . 5 „ E 12..CgNC:SQ : ::. .............: :....: :..........: :.................: :.......: .................. :: :: ..........: ::.....: EX SD TO BE RE VED� � . . . . . . . . . . . . . . . . . INSTALL 1 1/2 WATER SERVICE BEHIND SIDEWALK PER CITY OF RENTON STD PLAN ......................... . . . . . . . . . . . ....................................................... EX S F/I OBE ABANDONED 320.3. TAP LOCATION AT WATER MAIN AS INDICATED. METER BOX LOCATION AS 2 ................ ........ 2 2 SPECIFIED. ............. ............... .. :::::::.. .: ................. �...18..... . . . . . . . . . . �.. ... ................... ................. :::::: . . . . . . . . . . . ...................2. ....... :::::::::.::TEE: ::N. PROP.1:2��: .::::: I . ............ PER ..aR STD-PLA 300...1.. TEE PROP 12" WM :: ...... ................. G � A PER COR STD PLAN 300.1 ...........6,�. ...... ......: ......... 6 INSTALL 12" POLYPIG STATION PER CITY OF RENTON STD PLAN 300.7. CONCRETE 1 �. X J 1 GA E VALVE 1 BLOCKING PER CITY OF RENTON STD PLAN 330.1. +2� w 0+40 0+60 0+80 0+90 0+20 0+40 0+50 0+20 0+40 0+50 un J 10 CONNECT TO CITY OF RENTON WATER MAIN WITH 24"X12" TAPPING TEE AND TAPPING _ o Q o Y 12" GATE VALVE PER CITY OF RENTON STD PLAN 300.6. CONCRETE BLOCKING PER CITY Uo�>�U z m � c) w J O � a- J S GRADY WAY S GRADY WAY OF RENTON STD PLAN 330.1. CITY OF RENTON TO INSTALL FINAL CONNECTION AFTER Q � + m� - N Q � 00 X 0 SUCCESSFUL PRESSURE TEST, POLYPIGGING, AND DISINFECTION PER CITY OF zo FH 1-STA 16+42 PROFILE �C� FH 2-STA 20+63 PROFILE �D� RENTON STD PLAN 300.6. CONTRACTOR TO PROVIDE ALL MATERIALS, EXCAVATION, `) 4 1 UT.03 SHORING, BACKFILL AND FINAL ROADWAY RESTORATION. 1 UT.02 16 INSTALL 8-INCH WATER MAIN CONNECTION AND CONCRETE BLOCKING PER CITY OF SHATTUCK AVE S RENTON STD PLAN 330.1. INSTALL UNDER PROPOSED DI STORM DRAIN WITH 18" VERTICAL SEPARATION. CONNECT TO EXISTING 8" DI WATER SERVICE WITH 8" MJ WATER MAIN BRANCH SLEEVE. 1 UT.02 18 DEFLECT WATER MAIN UNDER EXISTING STORM DRAIN WITH 18" VERTICAL SEPARATION AND 22 LINEAR FEET OF 24" STEEL CASING PER CITY OF RENTON STD PLAN 300.8. MAXIMUM DEFLECTION OF WATER MAIN T04MANUFACTURER'S RECOMMENDED MAXIMUM DEFLECTION. Ld J 0 Lj I w Z 0' 20' 40' HORIZONTAL SCALE 0' 10, 20' DEVELOPMENT ENGINEERING �- ]�j Michael Sippo 09/11/2024 VERTICAL SCALE S-421427 W-421427 AD -READY SUBMITTAL ' 9. T IDESIGNEDAPPROVED. METRO TRANSIT CAPITAL DIVISION DATE: QP�� wSSFI I. VANBLANKENSTEIN G. FRANCO JUNE 2024 (425) 453 5000 o ti, DRAWN: RAP I D RI D E I LINE 1100 112TH AVE NE, SUITE 500a co t)sBELLEVUE, WA 98004 � 0 King County z A. ZEA & S. NIMS 06/1 2 CHECKED: PROJECT NO: RENTON SEGMENT DRAWING NO: � d WASTEWATER UTILITY o WATER UTILITY ° SFQ/ST0z"_ �� P.TISSELL E00566E18 MET UTILITY PROFILES 1 UP.01 stowell 08/29/2024 JValdez 09/05/2024 S/ONA1- CHECKED. CONTRACT NO: No. REVISION BY APP'D DATE � �'� SHEET 2�9 OF 473 K. CHANG YUEN CXXX)OCXXX N r O O r N 0 O N O O 0 N N Q J r N q1 ti N 1q r N N a Q CV LO co co U) 0 N 00 0 N C cz U (E L U C V N U1 C 0 0 U rK � U1 z Q 00 z co w o of LL N 0 �I 175 � X 2� U � N z o w 0 >+ � O J O � U) N _ of a� ry o w CL 0 =D X R o O U � m m � 0 NI M �CU a 7E o COY a Q'pCYD LO LO U CIJ o �I am rn N oCD� C, CD U 0 ��w-2 w c o =o �= a O-' � 0 X U_ w Q 0 o w w Z z O O o o z z 10PROP 12" DI SD7 Q w wLIJ w. . X . EG..... F- .. w .. ......... EX WM TO BE RE """ W EX 12" SD TO BE RE VED ::::::::.: : :: :: ::.::::P:R P. FH..: ............ ......... P P'GAS-- ... SEX SS F1V1 TO E ABANDONED .. . .............. ......... .... .. ..6..G TE'VALVE...... ......... 2 ... 1 ...... PER'CO D'STD'PLAN 3 0:1 .... 0+20 0+40 0+50 S GRADY WAY FH-3 STA 22+04 PROFILE 1 UT.03 40. 30- EX 20. ............................................. ::::::: :::::::: :::::::: :::PROP -FH.... ........ ....... ...... :.....: ......... ......... EG :::: ... .:� ................... FG......... ::............. ........... 4"'wM ...:. T'EE.... ....��.. "...AT1*:VALVE . ....TO 'EMi41.N.......... O RE�.. AIN- ... ......... ................... 10+00 10+20 10+40 TALBOT RD S FH-6 STA 11+10 PROFILE 1 UT.05 30- PROF 20- 15- 0 w z O 0 a PROP FH ofin °I °I ............... ............... ................... Q.....w..... �....W.....F x.....� w ... .X ... . .. .. ......... EG..... ......... GAS ----�' :: : :::::: :::::::... ........ . ......�r6"'(_',ATE'VALVE EX M' TO ....... .... ................... ......... ......... ........ ...TE-E ON- PROP •12" M..... ................................. ...... • • • • • •PE I CO•R• STD •P•L•A .300•.1• �E REMOVED 0+20 0+40 0+50 S GRADY WAY FH-4 STA 24+16 PROFILE ("_F� 1 UT.04 F PROP 12" DI SD PROP GAS. EX SD TO BE REMOVED 0 w z O 0 z Q m w O . �....... �..... w a ..... w.....tx.....}.x............... :... ......... u, .. ...... ......... ...... • • • • • .. .EX SS FORCE MAIN TO BE REMO VED AT CROSSING 8,". GATE ALVE ........... ......... :: TEE :ON ... ................... ......... .... PROP' 12"' M ............... ......... 0+20 0+40 0+50 S GRADY WAY 8-INCH WS RELOCATION 1 UT.03 S GRADY WAY SS FORCE MAIN PROFILE 1 UT.03 - 1 UT.04 30- 20- 15- "'�' '"'^ ""'^ USE EXISTING CHF "' CONNECT TO EXISTING MANHOLE PENETRATION WITH KOR-N-SEAL 1 106 SERIES BOOT CONNECT( :......:....: . ................ .. o ..... :::::... E�7 :::::::::: PROF ......... ................. .....� .......... ......... ......... FG..... :::::W :::.:...... ....... ................: .................. ................. ................... 7 EX:1 . ....... ..........E'-rLlz-:,'. GATE -VALV ......... ...........ON:P:RQP::l2:" VUIVI:::: ............PE 'COR'STD'PL 1V'300: FH 0+20 0+40 0+50 S GRADY WAY CONC SD FH-5 STA 14+64 PROFILE G 1 UT.04 WATER MAIN PROFILE 1 UT.16 AD -READY SUBMITTAL 7 (425) 453-5000 Jacobs 1100 112TH AVE NE, SUITE 500 BELLEVUE, WA 98004 19 WASTEWATER UTILITY �' WATER UTILITY (D No. REVISION BY APP'D DATE jstowell 08/29/2024 JValdez 09/05/2024 25 DESIGNED: I. VANBLANKENSTEIN DRAWN: A. ZEA & S. NIMS CHECKED: P. TISSELL CHECKED: K. CHANG YUEN PROP HDPE SS FORCE MAIN EX MH K GRAVITY SS NEW PIPE CONNECTION TO EX MH DETAIL rl� NTS WATER & SANITARY SEWER NOTES 21 INSTALL NEW 1-1/2" HDPE SDR 21 SANITARY SEWER FORCE MAIN. 22 INSTALL 1-1/2" GATE VALVE WITH HDPE FUSIBLE ENDS AND REDUCER. 24 VERIFY EXISTING AND CONNECT TO EXISTING 1-1/2" PE SDR-PRESSURE RATED TUBE WITH MECHANICAL COMPRESSION COUPLING. 25 REMOVE EXISTING FORCE MAIN CONNECTION AND CONNECT NEW FORCE MAIN TO EXISTING SANITARY SEWER MANHOLE WITH KOR-N-SEAL 1 106 SERIES BOOT CONNECTOR PER DETAIL 1. 28 INSTALL NEW 10" DUCTILE IRON WATER MAIN. 29 INSTALL AND CONNECT TO EXISTING SOOS CREEK WATER & SEWER DISTRICT WATER MAIN AFTER SUCCESSFUL PRESSURE TEST, CUBING, AND DISINFECTION PER SOOS CREEK DESIGN AND CONSTRUCTION STANDARDS - WATER. APPROVED: G. FRANCO PROJECT NO: E00566E18 CONTRACT NO: CXXXXXXXX King County METRO DEVELOPMENT ENGINEERING Michael Sippo 09/11 /2024Nj 0' 20' 40' HORIZONTAL SCALE 0' 10, 20' VERTICAL SCALE METRO TRANSIT CAPITAL DIVISION RAPIDRIDE I LINE RENTON SEGMENT UTILITY PROFILES W-421428 DATE: JUNE 2024 DRAWING NO: 1 UP.02 SHEET NO: OF 210 473 NEW SLIP RESISTANT SOLID LID Q CV cz co cz U) O N 00 O cz U C V N U7 C CB O U U) (Y z Q Oo wo of 1 3: LL N O cl .5 I 75 cu X � � U � N Z o LL.I 0-) w 0 x o 72 T � O (v U J U — o IY U) N _ ow CL 0 =D x R o O O m _j00 0 NI M a cu o m Y co Lr) CO U > V ON O I a) rn N oC� o U 0 ��w-2 w c o o = a 0LLJ X LL 0-0 w CD Q U a x .310 Gz o4 /__7A .Sf 7/7// �r A� "/7 /r�l��O //V TOP .SL2,tz? A, R-7 �;A"E-_ 4L MANHOLE DEMOLITION DETAIL A NTS 1 UT.04 MANHOLE NOTES AREMOVE AND STORE EXISTING TOP SLAB AND MEASURE EXISTING TOP SLAB SUPPORTS. AREMOVE TOP PORTION OF EXISTING PRECAST MANHOLE RISER SECTION. KEEP EXISTING REBAR/WELDED WIRE ABOVE CUT LINE. CHIP CONCRETE AROUND EXISTING REINFORCEMENT. ACUT EXISTING VERTICAL REINFORCEMENT TO 1" BELOW TOP OF NEW CONCRETE TONGUE AND GROOVE ON PROPOSED CONCRETE TOP SLAB SUPPORT. APOUR NEW CONCRETE SUPPORT ON TOP OF REMAINING PRECAST MANHOLE RISER SECTION AROUND EXISTING REINFORCEMENT. MATCH DIMENSIONS OF EXISTING TOP SLAB CONCRETE SUPPORT. AINSTALL EXISTING MANHOLE TOP SLAB ON LOWERED MANHOLE WITH RUBBER GASKETED JOINTS AND REPLACE VENTED COVER WITH SLIP RESISTANT SOLID LID. rOP.51 .AB RUBBER GASKETED JOINT SEE NOTE 4 5 •' ",,4NHOL E PROPOSED FINAL ELEVATION: 31.885' d 1, 1I\1STA L L PQL YE THYLEME 1, J ., , a 4 FCAM EOLIAL TO ETH.4 - �,�ArUh'DL FGA,M� 2z0 , IC�HTL Y 8% C0M ACT'EA0 B.Er�,��E �IrUCE " �.4 Eit/L� PIPE AND C0-1 WALL - (T YPJ 1 "DfA k/T/X/.s/Ort/ 4 C��/T�.�/�E V OP1,U//i/G INTETIONALLY ROUGHEN CONCRETE SURFACE TO 1/4" AMPLITUDE 7 SLJPPD/i�T /81151c;,OOL 'LI.NGS ARE TIGHT-ENED ) �Ql1.�IL �4TEr�/AL. AD -READY SUBMITTAL 7 (425) 453-5000 1100 112TH AVE NE, SUITE 500 ,JacobsBELLEVUE, WA 98004 WASTEWATER UTILITY No. REVISION BY APP'D DATE jstowell08/29/2024 _ Ix I ���CA.ST BASE _52ffCT/Ortl WIZ-,? Z"Z2/L� 7/-/ROUG.h' �/OL ES, MANHOLE RECONSTRUCTION DETAIL B NTS 1 UT.04 GENERAL NOTES 1. VERIFY AND MATCH EXISTING TOP SLAB SUPPORT DIMENSIONS BEFORE POURING CONCRETE. 2. FIELD VERIFY FINAL GRADE BEFORE DEMOLISHING EXISTING PRECAST MANHOLE RISER. 3. CAST -IN -PLACE CONCRETE SHALL BE CLASS 4000. 4. RUBBER GASKETED JIONTS SHALL BE IN CONFORMANCE WITH ASTM C-443. DESIGNED: I APPROVED: I. VANBLANKENSTEIN DRAWN: A. ZEA & S. NIMS CHECKED: P. TISSELL CHECKED: K. CHANG YUEN G. FRANCO PROJECT NO: E00566E18 CONTRACT NO: CXXXXXXXX EXISTING TOP SLAB NEW CONCRETE TOP SLAB SUPPORT Pf�EC 72" k1,41VHOL c 3 I4 g r0/VG 24" D. /, ,S�ODL JCL 5"2� C�rV 725-,F /rV /l✓ IWOL ,�5. E/r v EXISTING REINFORCEMENT TO REMAIN 24" O. /. e_j 111 r f /PAL//UE E)(7 fX1,5XOiV - TEMO//ARY 51VACIAIG TO SLPPO/;�T �8''SPOOL &REMOY,E .QFTEf� COUPLINGS ARE TIGHTEIVED ) LIQ King County METRO 5'TYL.� 3� �•� �Q11,9L 15 Ol�//VG i ,474 �/5 -4Z_ Fi VELOPMENT ENGINEERING 'chael Sippo 09/11 /2024 ' S-421429 I W-421429 METRO TRANSIT CAPITAL DIVISION DATE: RAPIDRIDE I LINE JUNE2024 RENTON SEGMENT DRAWING NO: MANHOLE ADJUSTMENT DETAILS 1 UD.01 SHEET NO: OF 211 473